Records from 2010 to 2024. Most recent: inspection, 6 December 2024.
Documentation record
Registered dimensions (L × B × D)297.5 ft × 54.0 ft × 13.0 ft
Registered tonnagegross 1,754 / net 1,754
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderJEFFBOAT LLC · JEFFERSONVILLE, IN, UNITED STATES · built 2010
Hull materialSteel
PropulsionNot recorded
Hull shapeBox
Hull configurationMonohull
Hailing portNEW YORK, NY
Trade endorsementsCoastwise, unrestricted, Registry, non-fishing vessel
DocumentationValid · issued 16 June 2026 · expires 31 July 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1754 - Simplified, Net Ton
1754 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 20
6 December 2024
Administrative Inspection · Examination of Repairs
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8044354
2 June 2022
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7466761
7 October 2021
COI Inspection · Drydock Exam · Cargo Tank Internal · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7328365
1 July 2020
COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6979296
11 July 2018
Examination of Repairs · MTSA Verification · Internal Structural Exam · Periodic Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6472857
20 September 2017
MTSA Verification · Annual Inspection · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6287883
1 September 2016
Examination of Repairs · Plan Review (Other than "T")
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5981676
4 May 2016
Load Line/Change of Employment
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 5865413
16 June 2015
MTSA Verification · Internal Structural Exam · COI Inspection · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5154747
25 June 2014
MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4899073
5 August 2013
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 4675457
9 July 2013
Deficiency Check · Periodic Inspection · MTSA Verification · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4646920
19 October 2012
Annual Inspection · MTSA/ISPS Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4467809
12 October 2011
Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4166795
21 June 2011
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 4052527
14 September 2010
Construction Oversight · Plan Review (Other than "T") · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3849420
3 September 2010
Load Line/Change of Employment
Administrative · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3841098
31 August 2010
Type not recorded
No type recorded · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3839799
27 July 2010
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 3807195
3 March 2010
MTSA Verification · Internal Structural Exam · Hull Examination · Cargo Tank Internal · Initial Construction-Excluding Oversight · Initial Certification
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3714732
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 25 June 2014
Resolved
Each [...] transfer pipe system [...] must not leak under static liquid pressure at least 1.5 times the MAWP. The equipment test of the vessel's cargo piping required under 33 CFR 156.170 was conducted at 125 psi when the cargo piping MAWP is 150 psi.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 September 2014
Resolution: Vessel operator submitted inspection test and report for the testing of the cargo pipeline. Pipeline hydro tested at 225 psi for 30 minutes.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 25 June 2014
Resolved
Each nonmetallic transfer hose must not burst, bulge, leak, or abnormally distort under static pressure of at least 1.5 times the MAWP. The equipment test of the vessel's nonmetallic transfer hose was conducted at 125 psi when the hose MAWP is 150 psi.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 July 2014
Resolution: Received email with a copy of the Certificate of Inspection & Test for a replacement transfer hose. Certificate reflects a working pressure of 225 PSI and a test pressure of 340 PSI.
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 25 June 2014
Resolved
The last 1.0 meter (3.3 feet) of vapor piping before the vessel vapor connection must be painted Red/Yellow/Red iaw provided cite. Red/Yellow/Red paint was offset behind the connection, manifold was painted green. (46 CFR 39.2001(h))
Due 26 July 2014
Resolved 8 July 2014
Resolution: Received email with pictures of the vapor connections. Vapor connections are now marked iaw 46 CFR 39.2001(h)
Electrical › Electric Generation Source (service) › Overcurrent Device
Issued 9 July 2013
Resolved
No.2 generator was inoperable and not able to conduct safety trips. (Over speed, Lube Oil Pressure). Vessel will Lock Out Tag Out proceedure until generator is capable of performing specific shutdown test.
Due 23 July 2013
Resolved 17 July 2013
Resolution: Operationally tested L/O shutdown and overspeed trip devices, all SAT.
Deck/Cargo › Vapor Control Systems › Liquid Overfill Protection
Issued 9 July 2013
Resolved
Vessel was unable to demonstrate proper function test of the High Level and Overfill alram system onboard.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 July 2013
Resolution: Verified proper operation of high level and overfill alarms using portable test unit. All SAT.