Records from 2011 to 2026. Most recent: inspection, 20 April 2026.
Documentation record
Registered dimensions (L × B × D)287.5 ft × 78.0 ft × 24.0 ft
Registered tonnagegross 4,276 / net 2,521
ITC dimensions (L × B × D)287.5 ft × 78.0 ft × 24.0 ft
ITC tonnagegross 4,276 / net 2,521
BuilderZIDELL MARINE CORPORATION · PORTLAND, OR, UNITED STATES · built 2010
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portPORTLAND, OR
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 3 June 2026 · expires 30 June 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it8540 - Dead Weight, Metric Ton
4276 - Convention (Subpart B), Gross Ton
2521 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 46
20 April 2026
Vessel Attendance · Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8329399
3 March 2026
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8308912
21 January 2026
Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 8299318
28 November 2025
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8274836
27 November 2025
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8276426
26 November 2025
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8276455
6 May 2025
Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8127450
10 December 2024
Annual Inspection · MARPOL Annex II Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8043977
1 December 2023
MARPOL Annex VI Survey · MARPOL Annex II Examination · MARPOL Annex I Examination · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8172666
13 October 2023
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7808328
12 December 2022
Administrative Inspection · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7606421
12 December 2022
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7613946
27 October 2022
Internal Structural Exam · Drydock Exam · Administrative Inspection · Cargo Tank Internal
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7584202
9 February 2021
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7139952
13 April 2020
Administrative Inspection · Deficiency Check · Internal Structural Exam · Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6938651
1 March 2020
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6953810
10 August 2019
Type not recorded
No type recorded · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6827862
12 July 2019
Bulk Liquid Transfer Monitor
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 6747627
2 June 2019
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6708649
29 March 2019
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6648998
13 February 2019
MTSA Verification · Administrative Inspection · MARPOL Annex I Examination · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6625500
10 January 2018
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6308886
16 September 2017
Type not recorded
No type recorded · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6274954
31 August 2017
Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6256511
14 August 2017
Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6247798
16 February 2017
MARPOL Annex I Examination · Administrative Inspection · MARPOL Annex VI Survey · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6089467
27 October 2016
Drydock Exam · Cargo Tank Internal · Damage Survey · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6031491
13 October 2016
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6024691
18 February 2016
MARPOL Annex I Examination · COI Inspection · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5816246
3 February 2016
Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5803995
17 September 2015
Type not recorded
No type recorded · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 5751928
4 August 2015
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5206178
25 November 2014
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 5072241
24 February 2014
Deficiency Check · MTSA Verification · Periodic Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4799681
24 January 2014
Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4788098
20 November 2013
Type not recorded
No type recorded · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 4757826
6 June 2013
Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4619130
24 February 2012
Deficiency Check · Annual Inspection · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4249892
24 January 2012
Examination of Repairs · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4232056
21 December 2011
Damage Survey · In-Service Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 4212916
18 December 2011
Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 4214602
27 September 2011
Administrative Inspection
Administrative · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4155470
9 August 2011
Administrative Inspection
Administrative · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4110479
20 July 2011
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4089365
30 June 2011
Administrative Inspection
Administrative · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4062955
9 June 2011
Administrative Inspection
Administrative · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4039974
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 3 March 2026
Resolved
All access openings in bulkheads at ends of enclosed superstructures shall be fitted with doors of steel or other equivalent material, permanently and strongly attached to the bulkhead, and framed, stiffened and fitted so that the whole structure is of equivalent strength to the unpierced bulkhead and weather-tight when closed. MI observed the gasket material in both port and starboard machinery houses to have gaps and degradation rendering them no longer weather-tight.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 March 2026
Resolved 20 April 2026
Resolution: Verified replacement of the port and starboard weather tight gasket.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil fuel tank protection
Issued 3 March 2026
Resolved
Activate a visible and audible alarm so that it can be seen and heard on the vessel where cargo transfer is controlled and in the cargo deck area; and activate an alarm early enough to allow the person in charge of transfer operations to stop the cargo transfer before the tank overflows. MI observed during testing of high and overfill alarms the audible alarm sounded approximately 15 seconds after the visual indication.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 April 2026
Resolved 19 May 2026
Resolution: MI attended the vessel and observed overfill alarm audible and visual activate at the same time.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 3 March 2026
Resolved
Any vessel of at least five net tons which engages in the fisheries on the navigable waters of the United States or in the Exclusive Economic Zone, or coastwise trade, unless exempt under § 67.9(c), must have a Certificate of Documentation bearing a valid endorsement appropriate for the activity in which engaged. MI observed the vessel SODO to be on an international route and REGISTRY is missing from the current COD.
Condition: Invalid
Action required: 702 - Prior to embarking on international voyage
Due 22 April 2026
Resolved 22 April 2026
Resolution: vessel representative provided documetnation proving the application of adding registry to COD. Due to lapse in appropriations unable to obtain updated COD.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 28 November 2025
Resolved
A survey shall be conducted such as to ensure that necessary repairs will be made prior to the carriage of cargo. Penetration in main deck shall be repaired to satisfaction of RO/USCG.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 December 2025
Resolved 2 December 2025
Resolution: Repairs were made with class oversight. all sat
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 13 April 2020
Resolved
Vessel missed required Internal Structural Exam (ISE) that was due no later than 02/28/2020. Company is required to conduct an ISE utilizing a competent company representative or Licensed Mariner prior to departure from Seward, Alaska and to the satisfaction of the Officer in Charge Marine Inspections.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 17 April 2020
Resolved 15 April 2020
Resolution: Received crews ISE results.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 13 April 2020
Resolved
Company is required to have an internal structural exam (ISE) completed by a competent 3rd party surveyor or an ABS surveyor no later than May 28, 2020 and to the satisfaction of the Cognizant OCMI.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 May 2020
Resolved 1 May 2020
Resolution: Received ABS survey report
Electrical › Electrical Distribution System (service) › Junction Box
Issued 16 February 2017
Resolved
Properly repair intrinsically safe/explosion proof emergency stop switch forward of cargo pumps. 46 CFR 111.105-3
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 March 2017
Resolution: Received email with tech report attached attesting to satisfactory repair of emergency remote shutdown as well as pictures depicting repair.
Pollution Prevention/Response › Prevention Equipment › Overfill Devices
Issued 16 February 2017
Resolved
Prove repair/proper operation of high level, overfill, and loss of power alarms for all cargo tanks and externals tanks. 33 CFR 155.480(b)(2) & 46 CFR 39.2007
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 March 2017
Resolution: Received email with tech report attached attesting to satisfactory repair of overfill alarm system.
Construction/Loadline › Hull › Bottom Plating
Issued 27 October 2016
Resolved
If during an examination, damage or deterioration to the hull plating, structural members, or cargo tanks is discovered, the Officer in Charge, Marine Inspection, may require the vessel to be taken out of service to effect permanent repairs. Complete all permanent repairs to the satisfaction of Coast Guard Marine Inspector.
Action required: 705 - Other - as specified
Due 27 November 2016
Resolved 3 February 2017
Resolution: All permanent repairs completed to the satisfaction of the Coast Guard.
Construction/Loadline › Hull › Double Hull
Issued 27 October 2016
Resolved
De-ballast ballast tank #4 and have tank inspected by Coast Guard (issue amended COI with new DDX and ISE dates etc. after deficiency is resolved - dated for 05FEB2017). 46 CFR 31.10-25
Action required: 705 - Other - as specified
Due 30 September 2017
Resolved 8 September 2017
Resolution: Conducted an ISE of ballast tank #4, observed no irregularities.
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 24 February 2014
Resolved
Issued 835 for non-conductive matting for distribution panels in both machinery houses.
Due 24 March 2014
Resolved 21 March 2014
Resolution: Received receipt of order for the nonconductive matting for the distribution panels.
Engineering › Compressed Air System (control) › Piping
Issued 24 February 2014
Resolved
Common rail air receiver gauge does not read above relief valve setting of 200psi. Issued deficiency for gauge of reading range of 240-400 psi above 200.
Due 24 March 2014
Resolved 21 March 2014
Resolution: Photo of new gauge reading appropriately above 240 psi received and certified to the Marine Inspector as installed.
Engineering › Compressed Air System (control) › Valve
Issued 24 February 2014
Resolved
200 psi Relief valves could not be tested by installed air compressors onboard due to cut out relay kicking off compressor at 120 psi. Issued deficiency for bench testing air compressor tank relief valves.
Due 24 March 2014
Resolved 21 March 2014
Resolution: New relief valves Certificates of Conformance for model SA38 @ 200psi were recieved and certified to Marine Inspector as installed.
Construction/Loadline › Hull › Transverse Frame
Issued 24 January 2014
Resolved
In No. 1 stbd wing void found the 2nd frame aft of collision bulkhead inset 2 to 3 inches from No. 4 sidelong to No. 5 sidelong. Make permanent repairs or submit repair proposal to the attending marine inspector IAW 46 CFR 31.10-21(c)
Action required: 705 - Other - as specified
Due 24 February 2014
Resolved 24 March 2014
Resolution: Inspected permanent repairs to chord from #4 sidelong to #5. All satisfactory.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 21 December 2011
Resolved
Properly repair port and stbd navigation mat black, back shields. Back shields pushed back aprox 15 degs due to heavy weather.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 January 2012
Resolved 24 January 2012
Resolution: Prorerly repaired.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 21 December 2011
Resolved
Properly repair hand rails fwd of bow wind and spray shield.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 January 2012
Resolved 24 January 2012
Resolution: Replaced
Deck/Cargo › Cargo Stowage › General
Issued 21 December 2011
Resolved
Properly repair port side independent deck cargo tank (gasoline). Tank shell and insulation damaged due to heavy weather.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 January 2012
Resolved 24 January 2012
Resolution: Insulation repaired
Deck/Cargo › Vapor Control Systems › Liquid Overfill Protection
Issued 27 September 2011
Resolved
Radar gauging system is to remain disabled until the MSC provides a step-by-step procedure to be performed by a qualified technician and witnessed by a CG Marine Inspector. Further questions are to be addressed to [name withheld] at the MSC.
Due 31 March 2012
Resolved 24 February 2012
Resolution: Completed test MSC letter dated 29DEC11