Records from 1995 to 2026. Most recent: inspection, 2 July 2026.
Inspection history · 99
2 July 2026
Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8426237
21 June 2026
COC-CVE Annual · PSC A
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8407206
17 July 2023
COC-CVE Initial · COC-CVE Initial Prep
Administrative · Activities Europe · Activity 7756703
21 January 2022
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7383805
2 December 2021
Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7361321
2 November 2021
Type not recorded
No type recorded · USCG Southeast District (dp) · USCG Southeast District (CGD-SE) · Activity 7343964
19 August 2021
COC-CVE Annual · Ballast Water Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7291183
1 February 2020
COE-Dockside
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6896140
1 February 2020
Bulk Liquid Transfer Monitor
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6902130
31 January 2020
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6897528
25 January 2020
Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7059713
29 December 2019
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6880800
24 October 2019
COC-CVE Quarterly · Ballast Water Examination · ISPS III Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6837695
24 October 2019
Bulk Liquid Transfer Monitor
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6841818
12 July 2019
Bulk Liquid Transfer Monitor
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 6747627
19 June 2019
ISPS III Exam · NPV Safety Exam · In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6716910
25 April 2019
ISPS II Exam · PII Safety Exam · COC-CVE Annual · Ballast Water Examination
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6654057
10 December 2018
Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6594774
29 November 2018
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6586066
23 October 2018
COC-CVE Quarterly · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6565612
7 May 2018
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6408443
29 April 2018
ISPS II Exam · COC-CVE Annual
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6401526
22 April 2017
COC-CVE Quarterly · Ballast Water Examination · Administrative Inspection · ISPS II Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6129382
28 October 2016
Ballast Water Examination · Deficiency Check · COC-CVE Annual · ISPS II Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6029551
30 August 2016
In-Service Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5987235
22 August 2016
Administrative Inspection
Administrative · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 5979549
8 March 2016
In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5829484
2 October 2015
ISPS II Exam · COC-CVE Annual · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5734321
14 October 2014
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 5005059
13 October 2014
ISPS II Exam · PII Safety Exam · Ballast Water Examination · COC-CVE Annual
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4992535
8 May 2014
ISPS II Exam · Ballast Water Examination · COC-CVE Quarterly · PII Safety Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4851369
16 September 2011
COC-CVE Annual · ISPS III Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4143938
20 September 2010
COC-CVE Annual · Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3853241
30 November 2008
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3371633
16 September 2008
Administrative Inspection · COC-CVE Annual · ILO-147 Exam · Ballast Water Examination · ISPS III Exam · MARPOL Annex I Examination · MARPOL Annex V Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3325980
2 November 2007
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3091941
20 September 2007
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3062629
18 September 2007
ISPS III Exam · Ballast Water Examination · MARPOL Annex V Examination · Loadline Exam · ILO-147 Exam · MARPOL Annex I Examination · STCW 95 Exam · ISM Exam · COC-CVE Annual
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3060321
14 September 2007
Type not recorded
No type recorded · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 3057610
17 March 2007
ISPS II Exam · COC-CVE Quarterly
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2889380
15 March 2007
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2893973
12 March 2007
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2901932
29 September 2006
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 2788294
18 September 2006
Deficiency Check · ILO-147 Exam · ISPS III Exam · COC-CVE Annual · MARPOL Annex I Examination · MARPOL Annex V Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2780883
14 September 2006
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2777992
1 May 2006
COC-CVE Quarterly
Type not classified · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2637648
4 November 2005
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2528151
6 October 2005
Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2509099
19 September 2005
COC-CVE Annual · ISPS III Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2496339
10 March 2005
COC-CVE Quarterly
Type not classified · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2307980
20 September 2004
COC-CVE Annual
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2199945
19 September 2004
ISPS II Exam
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2197893
19 December 2003
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1967321
16 December 2003
Certificate of Compliance
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1965179
17 October 2003
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1930329
2 September 2003
Certificate of Compliance · Security Inspection
Physical examination · MSFO BUCKSPORT · USCG Northeast District (CGD-NE) · Activity 1890778
4 May 2003
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1785802
3 May 2003
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1785635
25 April 2003
Type not recorded
No type recorded · USCGC KISKA (WPB 1336) · USCG Oceania District (CGD-O) · Activity 1804949
20 December 2002
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1721395
28 April 2002
Quarterly Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1610149
27 April 2002
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1610002
27 April 2002
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1610102
19 April 2002
Security Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1608498
19 April 2002
Type not recorded
No type recorded · USCGC WASHINGTON (WPB 1331) · USCG Oceania District (CGD-O) · Activity 1624442
17 January 2002
Security Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1479417
17 January 2002
Security Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1480573
4 January 2002
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1475652
4 January 2002
Security Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1480564
3 January 2002
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1728740
22 December 2001
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1714393
22 December 2001
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1714422
6 December 2001
Control Verification · Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1473990
18 January 2001
MARPOL Annex I Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 825422
7 January 2000
Control Verification · MARPOL Annex I Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1420240
28 February 1999
Quarterly Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1365096
17 January 1999
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 4986
1 December 1998
Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1416800
20 January 1998
MARPOL Annex I Examination · Quarterly Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1364531
1 December 1997
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 155390
20 October 1997
Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 409079
20 October 1997
Quarterly Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1383691
10 October 1997
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 524956
26 August 1997
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 521761
24 July 1997
Quarterly Examination
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1375072
28 April 1997
Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 403100
28 April 1997
Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1371777
29 November 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 398118
29 November 1996
Control Verification
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1185987
4 January 1996
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 385839
4 January 1996
Control Verification
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 885979
20 October 1995
Administrative
Administrative · Marine Safety Center (MSC) · Activity 883721
9 September 1995
Deficiency Check
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 877322
24 August 1995
Quarterly Examination
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1428525
7 August 1995
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 456525
26 July 1995
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 480311
16 July 1995
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 4879
29 June 1995
Type not recorded
No type recorded · MSD KETCHIKAN · USCG Arctic District (CGD-A) · Activity 117420
2 May 1995
Control Verification · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1351666
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 21 June 2026
Resolved
74 SOLAS 01 II-2/41-2.4.7 16ac
In addition to the emergency lighting required by regulations 11-1/42 and 111/11.5, the means of escape including stairways and exits shall be marked, at all points of the escape route including angles and intersections, by lighting or photoluminescent strip indicators placed not more than .03m above the deck. The marking must enable passengers to identify all routes of escape and readily identify the escape exits. If electric illumination is used, it shall be supplied by the emergency source of power and it shall be so arranged the the failure of any single light, or cut in a lighting strip, will not result in the marking being ineffective. Additionally, all escape route signs and fire equipment location markings shall be of photoluminescent material. The administration shall ensure that such lighting or photoluminescent equipment has been evaluated, tested and applied in accordance with the guidelines developed by the Organization. PSCO observed emergency escape route sign was covered by stored equipment in AC room.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 July 2026
Resolved 21 June 2026
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 21 June 2026
Resolved
74 SOLAS 81 Amend II-2/11.2.3 16ac
In passenger ships, doors other than power-operated watertight doors, shall be so arranged that positive closure is assured in case of fire in the space, by power-operated closing arrangements or b ythe provision of self-closing doors capable of closing against an inclination of 3.5° opposing closure and having a fail-safe hook-back facility, provided with a remotely operated release device. PSCO observed fire doors 315, 326, 677B, 677A, 690 and 123B that did not fully close or latch when released.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 July 2026
Resolved 21 June 2026
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 21 June 2026
Resolved
74 SOLAS 81 amend II-2/30.4 16ac
The speed of door closure shall, if necessary, be controlled so as to prevent undue danger to persons. PSCO witnessed fire doors 579A and 811 closing too fast when activated.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 July 2026
Resolved 21 June 2026
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 21 June 2026
Resolved
46 CFR 147.60b(2) 50ac
Lockers or housings must be vented to the open air near the top and bottom for positive circulation of vapors. PSCO observed only top ventilation in the oxygen and acetylene storage locker.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 July 2026
Resolved 2 July 2026
Resolution: Received photos from the vessel showing installed natural ventillation for storage areas.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 21 June 2026
Resolved
74 SOLAS 81 Amend II-2/26.2.2 50ac
Where the contents and use of a space are such that there is a doubt as to its classification for the purpose of this regulation, it shall be treated as a space within the relevant category having the most stringent boundary requirements. PSCO found NFPA 30 lockers with permanently stored chemicals and flammable liquids in a category 13 space (shop store).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 July 2026
Resolved 21 June 2026
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 20 August 2021
Resolved
The doors shall be self-closing and have an approximately uniform rate of closure of no more than 40 seconds and no less than 10 seconds.
18 doors were found to close in less than 10 seconds.
Condition: Design Flaw
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 27 August 2021
Resolved 26 August 2021
Resolution: All doors were readjusted to close within the required rate. New door-pumps were ordered in case more doors should be found with the same issues.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 20 August 2021
Resolved
Terminations and joints in all connections shall be made so as to retain the original electrical, mechanical, flame-retarding and fire-resisting properties of the cable.
PSCO observed multiple cut wires/cables in the carpernter shop.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 27 August 2021
Resolved 26 August 2021
Resolution: Wires found were from a speed log removed in the past. All wires have been removed.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 20 August 2021
Resolved
A gauge indicating the pressure in the system shall be provided at each section stop valve and at a central station.
The gauges measuring the pressure at sprinkler section valce #28 were inoperable.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 27 August 2021
Resolved 20 August 2021
Resolution: Gauge was replaced before Examination team left the vessel.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 20 August 2021
Resolved
The following basic principles underlie the regulations in this chapter and are embodied in the regulations as appropriate, having regard to the type of ships and potential fire hazard involved:
containment and extinction of any fire in the space of origin.
PSCO found combustible materials stored above the highest sprinkler head in the Carpenter Workshop.
Condition: Design Flaw
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 27 August 2021
Resolved 26 August 2021
Resolution: All combustible materials were removed from the shelves above the sprinkler heads. The shelves were painted in red and labeled with signage "NO FLAMMABLE MATERIALS TO BE STORED".
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 19 August 2021
Resolved
Any required fire detection system shall be capable of immediate operation at all times and no action by the crew shall be nessacary to set it in operation.
Central #2 Fire detection panel on bridge was found showing "Fault" on the screen.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 27 August 2021
Resolved 26 August 2021
Resolution: The power supply and communication card of the unit in Pre Alarm condition were replaced.
01 - Certificates & Documentation › 011 - Ships Certificates › Continuous synopsis record
Issued 26 April 2019
Resolved
Current CSR ver. 10 ISM company information does not match ISM certificates.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 May 2019
Resolved 9 May 2019
Resolution: See DNV GL Narrative Summary dated 08May2019.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 26 April 2019
Resolved
Emergency Egress from machinery space missing signage. In addition two emergency egress doors (WTC 7 and WTC 11) require other actions (magnetic release push button/twist release knob) in addition to operating the handle. Either remove additional steps to prevent escape during an emergency or properly label/provide instructions at the egress point.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 May 2019
Resolved 9 May 2019
Resolution: See DNV GL Narrative Summary dated 08May2019.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 April 2019
Resolved
Properly install and configure ventilation for compressor control unit. Current setup has circuit isolation via taping off control to prevent overload when plugging in portable ventilation.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 May 2019
Resolved 9 May 2019
Resolution: See DNV GL Narrative Summary dated 08May2019.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 April 2019
Resolved
Fantail overhead has 02 lights and 01 junction box hanging from power supply due to corrosion of mounting hardware. 01 dead end wire coiled in wire run above/outside CO2 room access and wiring for light fixture inside paint locker is not properly supported.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 May 2019
Resolved 9 May 2019
Resolution: See DNV GL Narrative Summary dated 08May2019.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 26 April 2019
Resolved
Fire station on fantail port side leaks water from valve stem regardless of valve position.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 May 2019
Resolved 9 May 2019
Resolution: See DNV GL Narrative Summary dated 08May2019.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 26 April 2019
Resolved
Smoke detector not properly installed in fire locker adjacent from front office managers door, deck 5.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 May 2019
Resolved 9 May 2019
Resolution: See DNV GL Narrative Summary dated 08May2019.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 26 April 2019
Resolved
Survey all fire stations/lockers and ensure free from debris, cleaning gear, etc. (entire vessel).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 May 2019
Resolved 9 May 2019
Resolution: See DNV GL Narrative Summary dated 08May2019.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 October 2018
Resolved
1410- Propulsion main engine- 50ac
Machinery shall be of design and construction adequate for the service for which they are intended. The #3 main propulsion engine is leaking jacket water through the gasket. 74 SOLAS (1997) II-2/26.2(10)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 November 2018
Resolved 2 December 2018
Resolution: SEC NOLA RECIEVED A CLASS REPORT FROM DNV-GL SATISFYING THE REQUIREMENT.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 October 2018
Resolved
0750- Fire prevention- 10c
Auxiliary machinery spaces where storage of combustibles is prohibited, such as ventilation and air conditioning rooms. A/C station deck 2 port in way of FSD 1201 was being used for storage of 3 pallets of A/C filters which were combustible. 74 SOLAS (1997) II-2/26.2
Action required: 10 - Deficiency Rectified
Due 24 October 2018
Resolved 24 October 2018
Resolution: Removed combustibiles from space.
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Piping
Issued 28 October 2016
Resolved
0725 - The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations and shall remain fit to proceed to sea without danger to the ship or persons on board. During test of the aft morring deck deluge water system, PSCO observed a hole in the water supply piping. - SOLAS 74a I/11
Condition: Invalid
Action required: 705 - Other - as specified
Due 28 October 2016
Resolved 1 November 2016
Resolution: Vessel provided class attestation to the proper repair.
Fire Fighting › Combustible Materials › Furniture/Furnishings
Issued 8 March 2016
Resolved
0750- Vessel has added a significant amount of materials and furnishings for use throughout the vessel until 25MAR16. The securing methods for the additional containers and generators must be accepted by the Administration. In addition, the fire watch and refueling procedures must be accepted. 74SOLAS(14) CH.I/11(b)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 March 2016
Resolution: Vessel provided a Class report and statement from Flag.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 8 March 2016
Resolved
0750 - The vessel does not have up-to-date structural fire protection plans approved by the RO. In addition, plans must be submitted to the USCG MSC. 74SOLAS(14) CH.I/11(a)
Action required: 705 - Other - as specified
Due 25 April 2016
Resolved 28 October 2016
Resolution: Vessel provided evidence that plans had been submitted to both classification socisety and USCG MSC for review.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 5 October 2015
Resolved
EACH POWER OPERATED DOOR SHALL CLOSE FORM AN ACCESIBLE LOCATION ABOVE BULKHEAD DECK. FORWARD WTD HYDRAULIC STATION 7 AND 8 IN OPERABLE AN DNO ALLOWING WTD 7 AND 8 TO CLOSE FROM EMERGENCY STATION.
Action required: 705 - Other - as specified
Due 5 October 2015
Resolved 5 October 2015
Resolution: pROEPR REPAIRS MADE AND POWER DOORS WERE DEMONSTRATED TO FUNCTION PROPERLY.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 5 October 2015
Resolved
MEANS OF CONTROL OF ANY FIXED GAS FIRE-EXTIBNGUISHING SYSTEM SHALL BE SIMPLE TO OPERATE. AT EACH LOCATION THERE SHALL BE CLEAR INSTRUCTIONS RELATING TO THE OPERATION OF THE SSTEM. nORMALLY OPERATING INSTRUCTIONS WERE NOT POSTED INSIDE CO2 ROOM.
Action required: 705 - Other - as specified
Due 5 October 2015
Resolved 5 October 2015
Resolution: PROPER INSTRUCTIONS WERE POSTED IN THE CO2 ROOM.
Fire Fighting › Automatic Sprinkler System › Test Valves
Issued 1 May 2006
Resolved
Fire section valve #29 flow valve is not operating properly. Repair flow valve and prove proper operation.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 18 September 2006
Resolution: Deficient valve was observed to be in proper working order by inspection team.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 19 September 2005
Resolved
Provide instructions for use and label release mechanism buttons for all control access doors. Doors have release buttons that are not clearly visible and location of button varies from door to door.
Due 19 October 2005
Resolved 6 October 2005
Resolution: Boarding team went to vessel to verify the instruction for all control access doors were in place.
Lifesaving › Inflatable Liferafts
Issued 16 December 2003
Resolved
Conduct satisfactory liferaft deployment drill with full size (25 person) liferaft in presence of a US COAST GUARD MARINE INSPECTOR.
Due 5 January 2004
Resolved 5 January 2004
Navigation › Emergency Steering
Issued 16 December 2003
Resolved
Remove locks to emergency escape doors for port and stbd side steering gear compartments.
Due 5 January 2004
Resolved 5 January 2004
Accommodation/Occupational Safety
Issued 16 December 2003
Resolved
Provide signage for main and emergency exits from port and stbd steering gear rooms. LEGACY COMPONENT DESC: STEERING GEAR ROOMS
Due 5 January 2004
Resolved 5 January 2004
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 2 September 2003
Resolved
MAKE OPERABLE; LATCH ON FIRE-DOOR # 468.
Action required: 705 - Other - as specified
Due 2 September 2003
Resolved 2 September 2003
Resolution: CORRECTED DURING THE INSPECTION.
Operations/Management › Pollution
Issued 2 September 2003
Resolved
PROPERLY STOW CONTENTS OF STBD-AFT PAINT LOCKER.
Action required: 705 - Other - as specified
Due 2 September 2003
Resolved 2 September 2003
Resolution: CORRECTED DURING THE INSPECTION.
Construction/Loadline › Structures › Scuttle
Issued 2 September 2003
Resolved
MAKE OPERABLE; EMERGENCY ESCAPE DOOR #122 CLOSURE LATCH.
Action required: 705 - Other - as specified
Due 2 September 2003
Resolved 2 September 2003
Resolution: CORRECTED DURING THE INSPECTION.
Accommodation/Occupational Safety › Occupational Safety
Issued 20 December 2002
Resolved
Ensure proper means of escape; deck 3 fwd hotel store clear boxes.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 January 2003
Resolved 30 December 2002
Resolution: Issue was resolved via e-mail dated December 30, 2002. a photo was provided demonstrating that deck 3 fwd hotel store shelving and boxes removed. This action cleared the fire station and egress route. The e-mail was provided by Crystal Symphony Capt.
Electrical › Lighting (emergency)
Issued 20 December 2002
Resolved
Replace wire ties used to secure emergency speakers, properly secure emergency speakers. Speakers are located thoughout engine room. (this is hazard due to possible flame burning wires creating more debris for rescue teams) LEGACY COMPONENT DESC: Lighting Fixture
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 January 2003
Resolved 30 December 2002
Resolution: Issue resolved photo / via e-mail. Emergency speakers have been properly mounted.
Engineering
Issued 20 December 2002
Resolved
Make bulkhead penetration IWO hose locker 4/20 tight were new cable run was passed. (near FSD 436)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 January 2003
Resolved 30 December 2002
Resolution: Issued was resolved via photo / email dated 30 Dec 02. Bulkhead penetration IWO locker 4/20, item corrected. As per email provided by Crystal Symphony Captain.
Electrical
Issued 20 December 2002
Resolved
Replace electrical cover IWO main laundry lint trap on electrical junction box.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 January 2003
Resolved 30 December 2002
Resolution: Issue was resolved via e-mail dated Dec 30 2002. "The electrical cover in the main laundry lint trap was replaced immediately" E-mail was provided by Crystal Symphony Captain.
Accommodation/Occupational Safety › Occupational Safety
Issued 20 December 2002
Resolved
All trash recepticals and ash collection bins shall be non combustible.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 January 2003
Resolved 20 December 2002
Resolution: As per e-mail dated 30 DEC 02; the replacement of bins / non combustible bins is a corrective action in progress. E-mail was provided by Crystal Symphony Captain.
Fire Fighting
Issued 12 December 2000
Resolved
Provide non-combustible waste receptacles onboard or flag exemption for selected areas onboard.
Condition: Unknown
Due 12 March 2001
Resolved 6 December 2001
Resolution: Deficiency cleared 06DEC01.
Fire Fighting
Issued 28 February 1999
Resolved
Install smoke detector in Deck Store Room #III 4B, Deck II. SOLAS 74 (amd)II-2/41.2.2.
Condition: Unknown
Due 28 February 1999
Resolved 28 February 1999
Fire Fighting
Issued 28 February 1999
Resolved
Properly restow linen locker 032, deck 10. The linen and boxes are stackedto the ceiling blocking sprinkler heads. SOLAS 74 (amd) II-2/12.
Condition: Unknown
Due 28 February 1999
Resolved 28 February 1999
Electrical
Issued 28 February 1999
Resolved
Install Low Location lighting on the aftermost stairtower on deck 4. Stairtower is secondary egress route. SOLAS 74 (amd) II-2/28.
Condition: Unknown
Due 28 February 1999
Resolved 28 February 1999
Fire Fighting
Issued 28 February 1999
Resolved
Install smoke detectors in lieu of heat detectors in the following five pantries: Palm Court Bar Pantry, and forward/aft pantries on Decks 9 and 10; or provide waiver from classification society. SOLAS 74 (amd) II- 2/41.2.2.
Condition: Unknown
Due 28 February 1999
Resolved 28 February 1999
Lifesaving
Issued 28 February 1999
Resolved
Provide crew list for second-in-command for each lifeboat. SOLAS 74 (amd) III/10.
Condition: Unknown
Due 28 February 1999
Resolved 28 February 1999
Lifesaving
Issued 28 February 1999
Resolved
Provide proof from classification society that all survival craft includingthe required davit launched liferafts can be lowered with full compliment within 30 minutes. SOLAS 74 (amd) III/20.
Condition: Unknown
Due 28 February 1999
Resolved 28 February 1999
Fire Fighting
Issued 1 December 1998
Resolved
INSTALL LOW LEVEL LIGHTING IN THE PASSAGEWAY FROM BRIDGE TO MAIN EXIT
Condition: Unknown
Due 1 December 1998
Resolved 1 December 1998
Fire Fighting
Issued 1 December 1998
Resolved
REPAIR EMERGENCY EXIT DOOR #363 LOCK TO HIGH VOLTAGE ROOM. DOOR WILL NOT UNLOCK.
Condition: Unknown
Due 1 December 1998
Resolved 1 December 1998
Fire Fighting
Issued 1 December 1998
Resolved
ATTACH FIRE HOSES TO FIRE HYDRANT STATION LOCATED IN MAIN ENGINE ROOM #1 FWD, #3/27.
Condition: Unknown
Due 1 December 1998
Resolved 1 December 1998
Fire Fighting
Issued 1 December 1998
Resolved
INSTALL SMOKE DETECTORS IN FISH THAWING ROOM AND DRY STORES CO-LOCATED NEXTTO BAKERY ON DECK 4.
Condition: Unknown
Due 1 December 1998
Resolved 1 December 1998
Construction/Loadline
Issued 1 December 1998
Resolved
REPAIR WATERTIGHT DOOR #11-W AUDIBLE ALARM IN ENGINE ROOM.
Condition: Unknown
Due 1 December 1998
Resolved 1 December 1998
Construction/Loadline
Issued 1 December 1998
Resolved
REPAIR WATERTIGHT DOOR #3 IN ENGINEROOM, WEAK AUIBLE ALARM.
Condition: Unknown
Due 1 December 1998
Resolved 1 December 1998
Fire Fighting
Issued 1 December 1998
Resolved
ADJUST CLOSURE OF FIRE SCREEN DOOR TO 406A LOCKER
Condition: Unknown
Due 1 December 1998
Resolved 1 December 1998
Fire Fighting
Issued 1 December 1998
Resolved
PROVIDE REFLECTIVE TAPE ARROW INDICATING DIRECTION OF OPENING OF SLIDING FIRE SCREEN DOORS ON DECK 4.
Condition: Unknown
Due 1 December 1998
Resolved 1 December 1998
Electrical
Issued 1 December 1998
Resolved
REPAIR EMERGENCY LIGHTING INSIDE OF EMERGENCY EXIT DOOR DECK 4 #450.
Condition: Unknown
Due 1 December 1998
Resolved 1 December 1998
Fire Fighting
Issued 1 December 1998
Resolved
INSTALL LOW LEVEL LIGHTING IN PASSAGEWAY TO ENGINE CONTROL ROOM AND TECHNICAL OFFICE VIA DOOR 459 DECK 4.
Condition: Unknown
Due 1 December 1998
Resolved 1 December 1998
Fire Fighting
Issued 1 December 1998
Resolved
REPAIR FIRE SCREEN DOOR 489 AUDIBLE ALARM LOCATED ON DECK 4.
Condition: Unknown
Due 1 December 1998
Resolved 1 December 1998
Fire Fighting
Issued 1 December 1998
Resolved
INSTALL MISSING LOCK ASSEMBLY IN FIRE SCREEN DOOR #595
Condition: Unknown
Due 1 December 1998
Resolved 1 December 1998
Fire Fighting
Issued 1 December 1998
Resolved
INSTALL LOW LEVEL LIGHTING IN PASSAGEWAY FROM MEDICAL DEPT. ON DECK 5.
Condition: Unknown
Due 1 December 1998
Resolved 1 December 1998
Navigation
Issued 1 December 1998
Resolved
ADJUST PORT RUDDER ANGLE INDICATOR IN STEERING ROOM TO MATCH BRIDGE RUDDER ANGLE INDICATOR.
Condition: Unknown
Due 1 December 1998
Resolved 1 December 1998
Fire Fighting
Issued 1 December 1998
Resolved
ADJUST FIRE DOOR #662 FOR PROPER CLOSURE.
Condition: Unknown
Due 1 December 1998
Resolved 9 December 1998
Fire Fighting
Issued 1 December 1998
Resolved
INSTALL SMOKE DETECTORS VICE HEAT DETECTORS IN THE MEAT PREPERATION ROOM AND MEAT THAWING ROOM.
Condition: Unknown
Due 1 December 1998
Resolved 1 December 1998
Fire Fighting
Issued 20 January 1998
Resolved
Repair cracked weld where sprinkler head connects to branch line in rope store, Deck 4.
Condition: Unknown
Due 20 January 1998
Resolved 20 January 1998
Fire Fighting
Issued 20 January 1998
Resolved
In lieu of heat detectors, install smoke detectors in all refrigerated storerooms (where condensation is not a problem) to the satisfaction of theCoast Guard Marine Safety Center.
Condition: Unknown
Due 20 January 1998
Resolved 20 January 1998
Lifesaving
Issued 20 January 1998
Resolved
Obtain class approval for installation of new paint locker located on sternof deck 5.
Condition: Unknown
Due 20 January 1998
Resolved 20 January 1998
Fire Fighting
Issued 20 January 1998
Resolved
Install fire detection system in frozen store rooms to the satisfaciton of Coast Guard Marine Safety Center, Washington DC. (C G MSC).
Condition: Unknown
Due 20 January 1998
Resolved 20 January 1998
Fire Fighting
Issued 20 January 1998
Resolved
In lieu of the heat detectors, install smoke detectors in the vegetable - fruit preparation room (where condensation is not a problem) to the satisfaction of the Coast Guard Marine Safety Center.
Condition: Unknown
Due 20 January 1998
Resolved 20 January 1998
Lifesaving
Issued 20 January 1998
Resolved
Install remote indicators on all stairway enclousure boundary doors leadingto the weather decks.
Condition: Unknown
Due 20 January 1998
Resolved 20 January 1998
Engineering
Issued 20 January 1998
Resolved
Properly insulate turbocharger on emergency diesel generator.
Condition: Unknown
Due 20 January 1998
Resolved 20 January 1998
Lifesaving
Issued 20 January 1998
Resolved
In lieu of wood-glass doors on stairway enclosure exists leading to embarkation decks, install the proper rated doors.
Condition: Unknown
Due 22 January 1998
Resolved 22 January 1998
Fire Fighting
Issued 24 August 1995
Resolved
_x001C_ CLEAR OBSTRUCTIONS IN WAY OF FIRE SCREEN DOORS BEHIND GALAXY LOUNGE STAGE (FORWARD OF GALAXY LOUNGE).
Condition: Unknown
Due 24 August 1995
Resolved 24 August 1995
Accommodation/Occupational Safety
Issued 24 August 1995
Resolved
Remove grease from galley fan room (Deck 13) and provide proposal for preventing excessive grease from collecting in the exhaust uptakes.
Condition: Unknown
Due 24 August 1995
Resolved 24 August 1995
Fire Fighting
Issued 24 August 1995
Resolved
_x001C_ PROVE PROPER OPERATION OF FSD 645B.
Condition: Unknown
Due 24 August 1995
Resolved 24 August 1995
Fire Fighting
Issued 24 August 1995
Resolved
REPAIR SPRINKLER ALARM DEVICES FOR ZONES NO. 27 AND 28; PROVIDE PROPOSAL FOR ELIMINATING EXCESSIVE MOISTURE IN THE CONTROL BOXES.
Condition: Unknown
Due 24 August 1995
Resolved 24 August 1995
Fire Fighting
Issued 24 August 1995
Resolved
_x001C_ Adjust door for fire damper locker, Palm Court (Deck 11).
Condition: Unknown
Due 24 August 1995
Resolved 24 August 1995
Construction/Loadline
Issued 24 August 1995
Resolved
ADJUST/REPAIR WATERTIGHT DOORS AS NECESSARY TO PREVENT LOCAL CONTROL DEVICEFROM BECOMING STUCK IN THE OPEN POSITION AND PREVENTING REMOTE OPERATION.
Condition: Unknown
Due 24 August 1995
Resolved 24 August 1995
Fire Fighting
Issued 24 August 1995
Resolved
_x001C_ REMOVE COMBUSTIBLES STORED IN ELECTRICAL LOCKER (NO. 619), AFT AREA OF GALAXY LOUNGE.
Condition: Unknown
Due 24 August 1995
Resolved 24 August 1995
Construction/Loadline
Issued 24 August 1995
Resolved
_x001C_ PROVE PROPER OPERATION OF ALARM INDICATOR FOR WATERTIGHT DOOR 415.
Condition: Unknown
Due 24 August 1995
Resolved 24 August 1995