Records from 2010 to 2025. Most recent: inspection, 12 June 2025.
Documentation record
Registered dimensions (L × B × D)263.2 ft × 54.0 ft × 15.0 ft
Registered tonnagegross 1,741 / net 898
ITC dimensions (L × B × D)263.2 ft × 54.0 ft × 15.0 ft
ITC tonnagegross 1,741 / net 898
BuilderTRINITY MARINE PRODUCTS INC · MADISONVILLE, LA, UNITED STATES · built 2010
Hull materialSteel
PropulsionNot recorded
Hull shapeBox
Hull configurationMonohull
Hailing portPORTLAND, OR
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 18 February 2026 · expires 31 March 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1741 - Convention (Subpart B), Gross Ton
898 - Convention (Subpart B), Net Ton
4505 - Dead Weight, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 30
12 June 2025
COI Inspection · Internal Structural Exam · Cargo Tank Internal · Deficiency Check · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8149615
20 August 2024
Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7981757
21 June 2023
Periodic Inspection · Internal Structural Exam · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7719734
16 March 2023
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7652272
22 June 2022
Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7484184
27 July 2021
Annual Inspection · MARPOL Annex I Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7269748
24 May 2021
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7205780
1 June 2020
Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7202600
28 May 2020
MTSA Verification · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6962912
7 May 2019
Internal Structural Exam · MTSA Verification · Periodic Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6678496
19 June 2018
MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6451663
19 June 2017
Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6180725
3 March 2017
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6098651
18 November 2016
In-Service Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6051495
22 September 2016
In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6006782
8 March 2016
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5829617
8 March 2016
Internal Structural Exam · COI Inspection · Hull Examination · Administrative Inspection · Construction Oversight · Cargo Tank Internal
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5829639
17 November 2015
COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5764954
10 November 2015
Hull Examination · Internal Structural Exam · Cargo Tank Internal · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5761476
30 August 2014
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5014867
29 August 2014
Deficiency Check · Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4975193
19 July 2014
Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4930009
31 March 2014
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4826502
7 November 2013
Periodic Inspection · Examination of Repairs · Internal Structural Exam · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4747186
25 September 2012
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4518072
4 January 2012
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 4221733
15 November 2011
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4261998
19 August 2011
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4121029
13 July 2011
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 4085707
13 October 2010
Cargo Tank Internal · Hull Examination · COI Inspection · Construction Oversight · MTSA Verification · Internal Structural Exam · Deadweight Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3869297
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 20 August 2024
Resolved
Each cargo tank of a tank barge must have... an intrinsically safe overfill control system that activates an alarm and automatic shutdown system on the vessel. Overfill alarm did not activate for:
3P tank, 4S tank, 5P tank, 5S Tank, 6S tank
Rectify prior to cargo operations.
46 CFR 39.2009(a)(2)(iii)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 25 September 2024
Resolution: Witnessed satisfactory operation of high level & overfill alarms.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 20 August 2024
Resolved
Each outlet or junction box must have a cover unless a fixture canopy, switch cover, receptacle cover, or other cover is used. Stern junction box contained exposed wires without proper receptacle covers. Rectify within 30 days.
46 CFR 111.81-1(c)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 25 September 2024
Resolution: Witnessed satisfactory removal of junction box with no exposed wires to hazardous area.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 20 August 2024
Resolved
Each pressure-vacuum relief valve must be tested for venting capacity [and] have a mechanism to check that it operates freely and does not remain in the open position. Provide bench testing records of both pressure and vacuum valve functions.
46 CFR 39.2011(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 25 September 2024
Resolution: Vessel rep provided current certificates of PV valve bench test records.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 22 June 2022
Resolved
Each cargo tank of a tank barge must have one of the following liquid overfill protection arrangements. Observed inoperable loss of power alarm. Provide proof of loss of power alarm prior to cargo operations.
Action required: 705 - Other - as specified
Resolved 28 June 2022
Resolution: Vessel proved loss of power alarm
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 22 June 2022
Resolved
Flame arresters must be of a type and size suitable for the purpose intended and meet ASTM F 1273. P/V valve on the cargo vapor line has multiple holes in the flame screen. Replace prior to cargo operations.
Action required: 705 - Other - as specified
Resolved 23 June 2022
Resolution: Vessel provided proof of new installed flame screens.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 28 May 2020
Resolved
The Cargo Crane #2 Auxilliary cable is frayed/broken. Replace #2 Auxilliary cable IAW manufacturers recommendation prior to using cable during cargo operations.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 June 2020
Resolution: Replaced cable.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 7 May 2019
Resolved
If during an ISE, CTIE or underwater survey, damage or deterioration to the hull plating, structural members or cargo tanks is discovered, the OCMI may require the vessel to be dry-docked or otherwise taken out of service to further access damage or to effect permanent repairs.
During ISE inspection, found Cargo migration in #4P Void and #5P Void. Crack in weld found along outboard side of cargo tank at tank top approximately 3 ft in length.
Clean and Gas Free Cargo Tanks 4P and 5P, provide original construction drawing to identify type of seam, notify ABS, provide repair proposal to USCG.
Cargo Ops Denied
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 14 May 2019
Resolved 13 May 2019
Resolution: Verified satisafctory air test of #4 and #5 Port Cargo tanks.
Electrical › Electric Generation Source (service) › Ground Detection
Issued 19 June 2017
Resolved
Barges current 120V system is not affixed with the required ground detection as per regulation.
Action required: 705 - Other - as specified
Due 31 July 2017
Resolved 28 June 2017
Resolution: Received photograph of ground fault detection installation on 120V panel & verification that electrical one-line diagram is accurate.
Engineering › Steam System (auxiliary) › Lagging/Insulation
Issued 7 November 2016
Resolved
Vessel's steam piping does not have suitable insulation. Piping temperatures that exceed 150 degrees fahrenheit shall be suitably insulated to preclude injury to personnel. Vessel is restricted from using the steam piping until installed to the satisfaction of the marine inspector. 46 CFR 56.50-1 (k)
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 1 December 2016
Resolution: Received photos of all insulation properly installed.
Operations/Management › Vessel Activity › Construction/Repair
Issued 7 November 2016
Resolved
Vessel has not provided approved electrical drawings. Once approval has been obtained, provide copy to attending marine inspector. 46 CFR 110.01-3
Condition: Invalid
Action required: 705 - Other - as specified
Due 17 February 2017
Resolved 21 February 2017
Resolution: Received approved electrical drawings.
Operations/Management › Vessel Activity › Construction/Repair
Issued 7 November 2016
Resolved
Vessel made modifications to the approved plans for the steam piping. Once modifications have been approved, provide copy to attending marine inspector.46 CFR 31.10-1 (c)
Condition: Invalid
Action required: 705 - Other - as specified
Due 17 February 2017
Resolved 1 March 2017
Resolution: Received approved steam system drawings.
Construction/Loadline › Structures › Superstructure
Issued 8 March 2016
Resolved
Crane to be installed at final destination. Must be inspected by USCG or ABS prior to crane operationsp; observe load test.
Condition: Invalid
Action required: 705 - Other - as specified
Due 24 June 2017
Resolved 21 November 2016
Resolution: Inspected crane on 17NOV16. Received photograph on 21NOV16 resolving issue with explosion proof fitting. All sat.
Construction/Loadline › Hull › Side Shell
Issued 19 July 2014
Resolved
Barge sustained 20' x 6" inset along the port sideshell spanning the number 1 and 2 voids. Barge authorized one time loading/discharging operation before making permanent repairs to the satisfaction of attending MI.
Action required: 705 - Other - as specified
Due 8 August 2014
Resolved 2 September 2014
Resolution: Examined proper repairs of damaged area and witnessed air test of the #1 and #2 wing voids including the side shell and the WTB between the 2 compartments.
Documentation › Certificates/Documents › Coastwise Load Line Certificate
Issued 25 September 2012
Resolved
New ABS Loadline Certificate needs to be placed on board
Action required: 705 - Other - as specified
Resolved 25 September 2012
Resolution: New ABS Loadline received from office and placed on board
Documentation › Markings/Placards › Oil Discharge Placard
Issued 25 September 2012
Resolved
Oil discharge placard needs to be placed on fuel tank
Action required: 705 - Other - as specified
Resolved 25 September 2012
Resolution: New oil discharge placard placed on fuel tank