LOREN EADES is a 2013 tank barge. The Coast Guard has recorded 30 inspections since 2012, most recently in July 2025, along with 12 deficiencies and 1 casualty investigation in 2023.

Records from 2012 to 2025. Most recent: inspection, 22 July 2025.

Built
2013
Last inspected
22 July 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

1170385
Flag
UNITED STATES
Maury page id
psix-1170385

Inspections, by type

…with no type recorded4
Years with a record 13 calendar years (2012–2025)
The 30 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Documentation record

Registered dimensions (L × B × D)297.0 ft × 54.0 ft × 12.0 ft
Registered tonnagegross 1,616 / net 1,616
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderRAYMOND & ASSOCIATES LLC · CODEN, AL, UNITED STATES · built 2013
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeBox
Hull configurationMonohull
Hailing portPORTLAND, OR
Trade endorsementsCoastwise, charter
DocumentationValid · issued 18 November 2025 · expires 31 December 2026
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1616 - Simplified, Gross Ton
792 - Dead Weight, Gross Ton
1616 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.

Inspected as a tow unit · 7

Inspection history · 30

22 July 2025 Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8192039
30 June 2025 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8170682
25 June 2024 Annual Inspection · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7942137
26 April 2024 Type not recorded
No type recorded · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 7912076
16 October 2023 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7810520
20 June 2023 Load Line/Change of Employment · Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7719368
9 June 2023 Internal Structural Exam · Cargo Tank Internal · Drydock Exam · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7709613
3 May 2023 MTSA Verification · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7680090
16 March 2023 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7652272
11 August 2022 Load Line/Change of Employment
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7530675
27 July 2022 Annual Inspection · Deficiency Check · MTSA Verification
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7516967
30 May 2022 Load Line/Change of Employment · Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7471833
10 May 2021 MTSA Verification · Periodic Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7193585
26 February 2021 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7147062
7 October 2020 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7073146
23 June 2020 MTSA Verification · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6984360
22 April 2019 Administrative Inspection · Annual Inspection · MTSA Verification
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6667729
8 February 2019 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6622375
6 April 2018 Administrative Inspection · Examination of Repairs · Hull Examination · Internal Structural Exam · COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6386666
13 June 2017 Annual Inspection · MTSA Verification · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6174307
2 February 2017 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6081824
12 July 2016 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5938166
11 July 2016 Damage Survey · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5936826
8 April 2016 Administrative Inspection · Annual Inspection · MTSA/ISPS Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5867249
29 April 2015 Periodic Inspection · MTSA Verification · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5113524
29 January 2015 Examination of Repairs
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5059433
12 January 2015 Damage Survey
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5052205
17 December 2014 Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 5041449
8 May 2014 Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4852428
15 March 2012 Initial Construction-Excluding Oversight · Welding Related Inspections Qualification Testing · Cargo Tank Internal · Drydock Exam · MTSA Verification · Internal Structural Exam · Construction Oversight · Administrative Inspection · Deadweight Survey · Plan Review (Other than "T") · Initial Certification
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4264417

Deficiency record · 12

02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 22 July 2025 Resolved
Propulsion machinery, including main engines, reduction gears, shafting, bearings, and electrical equipment and systems, must:Be maintained to ensure proper operation; Marine Inspector observed excessive pitting on the cargo deck, hull, bow, and stern quarters. Vessel shall obtain Ultrasound shots to asses the full scope of wastage.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 July 2025
Resolution: See documents
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 22 July 2025 Resolved
The sidelights of vessels 20 meters or more in length shall be fitted with matte black inboard screens and meet the requirements of 84.15... Marine Inspector observed navigation lighting on the port side of the bow lacked matte black inboard screens. Vessel shall paint steel matte black
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 August 2025
Resolved 23 July 2025
Resolution: CG attended
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 22 July 2025 Resolved
The requirements in this subpart for piping systems apply instead of those in Section 122 of ASME 531.1. The following installation requirements are applicable to all systems: Piping systems used where the fluid temperature exceeds 150 °F must be suitably insulated as necessary to preclude injury to personnel. Marine Inspector discovered exposed exhaust piping. Vessel shall dress piping with adequate lagging according to the regulation.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 August 2025
Resolved 23 July 2025
Resolution: CG attended
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 July 2025 Resolved
The applicable standards established by the ABS Marine Vessel Rules(incorporated by reference, see 58.03-1), may be used as the standard for the design, construction, and testing of main and auxiliary machinery except as modified in this sub chapter Marine Inspector observed generator hose frayed, wasted, and spraying coolant.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 August 2025
Resolved 23 July 2025
Resolution: CG attended
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 3 May 2023 Resolved
Unless otherwise provided by this subpart, each vessel required to have a Certificate of Inspection is subject to the annual vessel inspection fee listed in table 2.10–101 for its vessel category. Barge is not current on user fees and has an outstanding balance of $545.12. User fees shall be paid prior to COI Renewal inspection. 46 CFR 2.10-101(a)(1)
Action required: 705 - Other - as specified
Due 31 May 2023
Resolved 3 May 2023
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 27 July 2022 Resolved
MI observed that the vessel could not run the cargo prime mover to test the remote shut downs. Vessel is restricted from cargo operations using both on board prime mover until tested for the attaining MI. 46 CFR 38.15-20 C701
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 August 2022
Resolution: ran and tested shut down.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 27 July 2022 Resolved
MI observed exposed wire runs on both prime movers due to block heater removal/install. Vessel is restricted from carrying flammable/ combustible cargoes (sub D cargoes) until system installed properly, removed, or the breaker is tagged out/locked out. 46 CFR 32.45-1 C701
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 August 2022
Resolution: wiring was removed and capped in a j box.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 27 July 2022 Resolved
I observed 02 gauges on the VCS line was inop or unreadable. Aft stbd manifold was unreadable and midships port manifold line was reading a vacuum under/negative number. Vessel is restricted from using those 02 manifolds for VCS. 46 CFR 38.10-1 C701
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 August 2022
Resolution: replaced both gauges.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 10 May 2021 Resolved
Water was identified in void tanks #1-#3. Replace gasket and prove watertight integrity of the hatches.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 25 May 2021
Resolution: Gaskets replaced. Witnessed hose test; all sat.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 10 May 2021 Resolved
The top side shell longitudinal in the #4S located two bays forward of the aft ladderwell has washed out welds. Make repair prior to next credit drydock.
Action required: 705 - Other - as specified
Resolved 13 June 2023
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 10 May 2021 Resolved
Fire extinguisher bracket near cargo pump is broken. Replace or repair bracket and prove proper operation.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 25 May 2021
Resolution: Bracket repaired.
Construction/Loadline › Hull › Side Shell
Issued 11 July 2016 Resolved
Coast Guard Sector Houston Galveston personnel received notification of vessel taking on water during cargo onload. Suffered a fracture of 8"x3" in bow rake. Made temporary repair. Issued CG-835 for permanent repairs to the satisfaction of the attending marine inspector by 08 August 2016.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 8 August 2016
Resolved 12 July 2016
Resolution: Cropped and renewed bow rake plating and transition plate. Test satisfactory.

Casualty record · 1

16 March 2023Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 7652272
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.