Records from 2000 to 2026. Most recent: inspection, 15 June 2026.
Documentation record
Registered dimensions (L × B × D)92.2 ft × 30.0 ft × 12.0 ft
Registered tonnagegross 118 / net 80
ITC dimensions (L × B × D)92.2 ft × 30.0 ft × 12.0 ft
ITC tonnagegross 229 / net 68
BuilderMAIN IRON WORKS INC · HOUMA, LA, UNITED STATES · built 1999
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portPORTLAND, OR
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 23 July 2026 · expires 31 August 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it118 - Regulatory (Subpart C or D), Gross Ton
229 - Convention (Subpart B), Gross Ton
80 - Regulatory (Subpart C or D), Net Ton
68 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 35
15 June 2026
Administrative Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8405478
4 April 2026
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8341744
27 May 2025
COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8140064
13 February 2025
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8079079
11 June 2024
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7932637
16 February 2023
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7637869
13 January 2023
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7621035
8 November 2022
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7592615
12 September 2022
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7557228
5 October 2020
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7071663
2 June 2020
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6966395
30 April 2020
Initial Certification · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6949976
24 January 2019
Examination of Repairs · In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6614715
15 May 2018
Industry Initiated Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6414719
6 April 2017
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6138222
23 November 2016
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6076358
28 May 2015
MTSA Verification · Industry Initiated Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5131365
4 March 2014
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4810230
19 June 2013
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4630322
26 February 2013
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4540170
11 July 2012
Deficiency Check · Industry Initiated Exam · MTSA Verification · DAPI Audit
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4375159
4 January 2012
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 4221733
20 May 2011
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4017258
11 February 2010
Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3678818
16 January 2010
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3665709
16 January 2010
Marine Casualty Follow Up
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3667360
11 August 2008
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3296076
1 August 2007
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3014704
15 December 2005
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2556832
15 November 2004
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2318897
2 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1965170
4 March 2002
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1631974
25 October 2000
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 769295
16 September 2000
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 208370
27 March 2000
Deadweight Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 816758
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 June 2026
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons on board under normal and emergency conditions. MI received report of steering failure due to loss of hydraulic pressure while transiting from Wilmington, NC to New York. Vessel is authorized a one-way transit to New York under the aid of an escort tug. Upon arrival to New York, vessel is to investigate and make necessary repairs IAW approved TSMS and to the satisfaction of an attending TPO surveyor prior to operating in a commercial capacity.
46 CFR 143.205 / 701 (A)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 June 2026
Resolution: Received TPO Report # 7680979
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 April 2026
Resolved
Machinery and electrical systems must be designed and
maintained to provide for safe operation of the towing
vessel and safety of persons on board under normal and
emergency conditions. Vessel self reported engine exhaust system failure and minor discharge of motor oil in the water. Provide casual analysis, repair plan, and class report attesting to proper operation prior to commercial operations.
46 CFR 143.205(a)
Action required: 705 - Other - as specified
Resolved 7 April 2026
Resolution: Company provided satisfactory technician report and TPO report attesting to repairs and satisfactory operation of the starboard engine.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 27 May 2025
Resolved
On vessels with more than one operating station, only one of them must be outfitted with a fire detection panel. Any other operating station must be outfitted with either a fire detection control panel or a remote indicator panel. Upper wheelhouse has no means to indicate if a fire is onboard.
46 CFR 142.330 (a)(3)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 June 2025
Resolved 25 July 2025
Resolution: vessel installed a visual and audible alarm and sent video to USCG
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 27 May 2025
Resolved
Remote fuel shutoff valve must be installed and operable from a safe place outside the space. Fuel shutoff valve was found with a hydraulic leak, tested not operational. Crew replaced cracked fitting.
46 CFR 143.260(d)
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 27 May 2025
Resolution: Vessel crew repaired cracked fitting. Tested satisfactory.