Records from 2014 to 2022. Most recent: inspection, 2 April 2022.
Documentation record
Tonnage as PSIX records it55909 - Regulatory (Subpart C or D), Gross Ton
29810 - Regulatory (Subpart C or D), Net Ton
55909 - Convention (Subpart B), Gross Ton
29810 - Convention (Subpart B), Net Ton
105335 - Dead Weight, Metric Ton
121449 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Inspection history · 15
2 April 2022
PSC B · COC-TVE Annual
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7422692
18 February 2022
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7398332
23 March 2021
PSC B · COC-TVE Renew
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7161663
26 September 2019
COC-TVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6814785
8 December 2018
COE-Administrative
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6594486
21 September 2018
COC-TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6542300
22 January 2018
COE-Dockside · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6341425
5 September 2017
COC-TVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6256116
22 August 2016
Ballast Water Examination · COC-TVE Renew · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5979743
4 August 2015
Ballast Water Examination · COC-TVE Annual · ISPS II Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5205176
2 August 2015
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5204025
13 August 2014
In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4953423
13 August 2014
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4954421
6 August 2014
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4945907
3 August 2014
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4942574
Documentation › Logs/Records › Ballast Water Logs/Records
Issued 4 August 2015
Resolved
2510; Vessel must maintain a Ballast Water Management Plan that has been developed specifically for the vessel that will allow those responsible for the plan to understand and follow it. Vessel has a Ballast and Bio-Fouling plans, however they are not following all parts of the plans, 33CFR2050(g), 10C.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 August 2015
Resolved 4 August 2015
Resolution: Discussed with the Captain, [name withheld], [name withheld] and Chief Engineer.
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 4 August 2015
Resolved
2510; The operator of a vessel with a capacity of 250 barrels of oil shall provide transfer procedures hat meet the requirements of the Code of Federal Regulations. Vessel does not have adequate transfer procedures, 33 CFR155.720, 10C.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 August 2015
Resolved 4 August 2015
Resolution: Discussed with the Captain, [name withheld], [name withheld] and Chief Engineer.
Stability › Watertight Integrity › General
Issued 13 August 2014
Resolved
0938 - Hull damage impairing seaworthiness - Vessel was struck on starboard quarter, by M/V FLAG GANGOS, creating a 10 foot long hole in the skin of the ship 4 meters above the waterline - SOLAS 74 (09 Cons) I/11
Action required: 705 - Other - as specified
Due 13 August 2014
Resolved 2 September 2014
Resolution: Reviewed and accepted class report from Lloyds Register of Shipping. The report stated the side shell plating was renewed and tested satisfactorily.
Pollution Prevention/Response › Response Equipment › Sorbents
Issued 13 August 2014
Resolved
1700 - Marine pollution - Annex I - Ensure clean-up of oil to affected area is conducted in accordance with ship's SOPEP and to ensure that the matierials used for the clean-up are replaced - MARPOL Annex I/37
Action required: 705 - Other - as specified
Due 13 August 2014
Resolved 2 September 2014
Resolution: Reviewed and accepted class report from Lloyds Register of Shipping. The report stated the stbd manifold has been cleaned and all SOPEP materials renewed.