MAURY USCG vessel records
← All vessels

VENDOME STREET

VENDOME STREET is a 2010 tank ship. The Coast Guard has recorded 16 inspections since 2016, most recently in June 2026, along with 3 deficiencies and 2 operational controls.

Records from 2016 to 2026. Most recent: inspection, 11 June 2026.

Built
2010
Last inspected
11 June 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 11 June 2026
…with no type recorded4
Operational controls None recorded without a removal date
Years with a record 8 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9573672
1113719
Flag
LIBERIA
Maury page id
psix-1113719

Documentation record

Tonnage as PSIX records it12680 - Convention (Subpart B), Net Ton
47879 - Dead Weight, Metric Ton
58000 - Displacement, Metric Ton
28778 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 3

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

CAP VICTOR Tank Ship · MISLE 902026 · 5 May 2022 · activity 7472578DOUBLE SKIN 803 Tank Barge · MISLE 1376243 · 5 May 2022 · activity 7472578WACHAPREAGUE Towing Vessel · MISLE 1377923 · 5 May 2022 · activity 7472578

Inspection history · 16

11 June 2026 COC-TVE Renew · Administrative Inspection · PSC B
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8392761
12 August 2025 PSC B · COC-TVE Annual · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8206366
29 June 2024 COC-TVE Renew · PSC B
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7939381
15 November 2023 Administrative Inspection
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7825202
29 May 2023 PSC B · COC-TVE Annual
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7696492
3 February 2023 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7631830
4 November 2022 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7589392
5 May 2022 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7472578
3 May 2022 COC-TVE Renew · PSC B
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7436818
2 August 2018 ISPS II Exam · Ballast Water Examination · COC-TVE Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6498191
30 December 2017 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6330606
26 December 2017 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6328818
25 December 2017 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6331545
20 October 2017 COE-Dockside
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6287452
20 May 2017 ISPS II Exam · Ballast Water Examination · COC-TVE Annual
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6150249
14 April 2016 ISPS II Exam · COC-TVE Renew · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5854076

Deficiency record · 3

06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 29 June 2024 Resolved
The arrangements and position of openings in the cargo tank deck from which emission of flammable vapors can occur shall be such as to minimize the possibility of flammable vapors collecting in the vicinity of deck machinery and equipment which may constitute an ignition hazard. P/V (pressure vacuum) valves 25, 35, 45,65,75, 1P, 5P, 6P, 7P, 8P are all freely passing gasoline vapors on deck, from the vacuum side of the P/V valve. Tank pressures are at an average of 6.7 kPa. The vessel is restricted from conducting cargo operations.
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Due 29 June 2024
Resolved 30 June 2024
Resolution: Resolved by ABS class report attesting to compliance with manufacturer's documentation.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 29 June 2024 Resolved
Where cables which are installed in hazardous areas introduce the risk of fire or explosion in the event of an electrical fault in such areas, special precautions against such risks shall be taken to the satisfaction of the administration. Found all temperature probes serving cargo oil pumps 1-4 to have either damage to the cables where armoring was damaged, the gland inside the probe to be unserviceable where light was passing through, and dead end wires (2) not properly secured inside the enclosure. Top 1-4 have 3 probes each, which are located in the cargo pumproom. Vessel is restricted from conducting cargo operations.
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Due 30 June 2024
Resolved 30 June 2024
Resolution: Resolved by ABS class report attesting to repairs made by the crew.
01 - Certificates & Documentation › 012 - Crew Certificates › Training and qualification MLC - Personnel safety training
Issued 29 June 2024 Resolved
The training manual shal contain instructions and information on the life saving appliances provided in the ship. Use of all survival equipment shall be explained in detail. Observed the absence of training for the hydrostatic releases in the training manual the installed hydrostatic releses did no mathc the other type of releases in the mnaunal.
Condition: Design Flaw
Action required: 10 - Deficiency Rectified
Due 30 June 2024
Resolved 30 June 2024
Resolution: Resolved by crew placing information for the correct hydrostatic release in crew training manual.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.