Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 16 July 2025
…with no type recorded11
Operational controls None recorded without a removal date
Years with a record 14 calendar years (1991–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDC3410
113939
Flag
UNITED STATES
Maury page id
psix-113939

Documentation record

Registered dimensions (L × B × D)48.8 ft × 20.2 ft × 7.4 ft
Registered tonnagegross 67 / net 45
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderRAYCO SHIPBUILDERS & REP · HOUMA LA, UNITED STATES · built 1971
Hull materialSteel
PropulsionDiesel
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portROCKPORT, TX
Endorsements, as the file codes themcw_un
DocumentationValid · issued 5 March 2026 · expires 31 March 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it67 - Regulatory (Subpart C or D), Gross Ton
45 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 24 inspections, each with its date, unit and type; 21 deficiencies with the resolution recorded against each, 1 without one; operational controls, none recorded without a removal date; 7 other vessels inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 7

Inspection history · 24

16 July 2025 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8187198
21 July 2022 Administrative Inspection · TPO Audit
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7512617
21 June 2022 Deficiency Check · Administrative Inspection · COI Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7483040
11 April 2022 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7428787
25 November 2014 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5029476
3 November 2014 Type not recorded
No type recorded · Station Port Aransas · USCG Heartland District (CGD-H) · Activity 5016785
3 November 2014 Damage Survey
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5017737
3 November 2014 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5017895
12 October 2014 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5005541
31 January 2012 Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4235877
13 January 2012 Industry Initiated Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4224579
19 December 2011 Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 4214608
6 January 2009 Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3389498
5 January 2009 Administration
Administrative · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3389119
3 May 2008 Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3213606
27 December 2006 Uninspected Other · MTSA Verification
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2846756
25 March 2005 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2319355
22 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1970632
25 November 1998 Uninspected Towing Vessel
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 811353
12 August 1998 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1130724
28 May 1998 Uninspected Towing Vessel
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1126487
29 December 1996 Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 186022
15 June 1995 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 379533
29 July 1991 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 666363

Deficiency record · 21

01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 16 July 2025 No resolution recorded
Vessel's scheduled Drydock and Internal Structural Examination (ISE) was to be completed prior to 30JUN2025. Drydock and ISE needs to be completed prior to any commercial operations.
Action required: 701 - Prior to carriage of passengers/cargo
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 28 June 2022 Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention. The following alarms must be provided: High bilge levels. The bilge alarms in the two aft void spaces did not provide any audio/visual alarm when actuated. Repair or replace the installed bilge alarms to the satisfaction of TVIB (TPO) or the Coast Guard.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 29 June 2022
Resolution: See attached TVIB report under documents - isolated signal wire to panel only, allowing each individual alarm to have their own individual warning light and audible alarm
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 28 June 2022 Resolved
Alarms must: Be visible and audible at each operating station. The alarm located at the operating station may be a summary alarm; if the alarm at the operating station is a summary alarm, the specific alarm condition must be indicated at the machinery or bilge location. The engine room bilge alarm actuated all indicator lights at the operating station instead of the specific bilge location. Repair the bilge alarm indicators to show the specific location of alarms to the satisfaction of TVIB (TPO) or the Coast Guard.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Resolved 29 June 2022
Resolution: See attached TVIB report - found common ground to system loose. reattached and tightened.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 28 June 2022 Resolved
The Vessel Security Officer must keep records of the activities as set out in paragraph (b) of this section for at least 2 years and make them available to the Coast Guard upon request. Vessel crew could not provide records of past security training or drills, and were not implementing satisfactory security training or drill policies and procedures. Rectify deficiency according to the satisfaction of TVIB (TPO) or the Coast Guard.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 July 2022
Resolved 11 July 2022
Resolution: See attached TVIB report under documents - Security drill performed by crew on vessel
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 28 June 2022 Resolved
The frame or support of any semi-portable fire extinguisher fitted with wheels must be welded or otherwise permanently attached to a steel bulkhead or deck to prevent it from rolling under heavy sea conditions. The wheeled semi-portable fire extinguisher was loose about the deck with no permanent support in place. Install permanent means of securing the semi-portable to the deck or bulkhead to the satisfaction of of TVIB (TPO) or the Coast Guard.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 July 2022
Resolved 29 June 2022
Resolution: See attached TVIB report - welded brackets to hand rail and set wheeled extinguisher in brackets and pinned in place
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 June 2022 Resolved
Propulsion machinery, including main engines, reduction gears, shafting, bearings, and electrical equipment and systems, must: Be maintained to ensure proper operation. Oil cooler lines for both Port and Starboard Main Diesel Engines were found to have missing chaffing gear and were showing signs of chaffing wear due to engine vibrations. Rectify deficiency according to the satisfaction of TVIB (TPO) or the Coast Guard.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 July 2022
Resolved 29 June 2022
Resolution: See attached TVIB report - New hoses were made chafing gear attached
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 28 June 2022 Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons on-board under normal and emergency conditions. The crankshaft pulley, alternator pulley, and alternator drive belt for both the Port and Starboard Main Diesel Engines were exposed and found to have missing machinery guards, creating a safety hazard to the vessel crew. Rectify deficiency according to the satisfaction of TVIB (TPO) or the Coast Guard.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 July 2022
Resolved 11 July 2022
Resolution: See attached TVIB report - fabricated and welded new crankshaft guards and alternator pulley guards for both main engines.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 June 2022 Resolved
The owner or managing operator must implement procedures to identify and mitigate health and safety hazards. Two 110v electrical outlets located below the helm unit were found in the hot/neutral reverse condition. Rectify deficiency according to the satisfaction of TVIB (TPO) or the Coast Guard.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 July 2022
Resolved 8 July 2022
Resolution: See attached TVIB report - electrical sockets were rewired
Construction/Loadline › Hull › Hull Plating
Issued 3 November 2014 Resolved
At some point in the vessels service life, modifications were made to increase horsepower, shaft size, and the propeller size. To do so, the modifications put in place may have contributed to the development of a six inch crack in the hull plating along a weld seam.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 December 2014
Resolved 28 June 2022
Resolution: Unsure when repairs were completed, no issues oberved during issuance of the initial COI
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 27 December 2006 Resolved
The vessel needs to have the following placard posted: Employee Assistance Programs, Chemical Testing, Garbage, Oil. Vessel needs to post onboard prior to 27JAN07.
Action required: 705 - Other - as specified
Due 27 January 2007
Resolved 3 January 2007
Resolution: Vessel''''''''s Master sent letter attesting that EAP, Chemical Testing, Garbage, and Oil placards have been posted.
Operations/Management › Cargo Transfer/Lightering › Vessel Transfer Procedures on Hand
Issued 27 December 2006 Resolved
Fuel Transfer Procedure Book was not provided to boat. Procedures from company states one will be provided. Vessel does have some fuel procedures onboard, but needs the book. Prior to 27 JAN 2007. Vessel needs to have the book on board.
Action required: 705 - Other - as specified
Due 27 January 2007
Resolved 3 January 2007
Resolution: Recieved letter from Master attesting that Fuel Transfer Procedure Book is onboard the vessel.
Operations/Management › Cargo Transfer/Lightering › Vessel Transfer Procedures on Hand
Issued 27 December 2006 Resolved
Vessel does not have a fuel piping diagram onboard. Vessel needs to have fuel piping diagram onboard with fuel transfer procedures per 33CFR155.750.
Action required: 705 - Other - as specified
Due 27 January 2007
Resolved 23 January 2007
Resolution: Recieved letter from Master attesting that the Fuel Piping Diagram is onboard vessel.
Operations/Management › Casualty Reporting/Post-Casualty Actions › Report of Potential Vessel Casualty
Issued 27 December 2006 Resolved
Vessel needs to have copies of CG2692 Report of Incident Form, onboard no later than 01JAN07 available at USCG.GOV and/or USCG.MIL
Due 1 January 2007
Resolved 3 January 2007
Resolution: Received letter from Master attesting that copies of CG-2692 are onboard vessel.
Navigation › Piloting/Steering › US Coast Pilot
Issued 27 December 2006 Resolved
Vessel does not have a copy of the Coast Pilot 5 onboard. Prior to getting underway have onboard.
Action required: 17 - Rectify deficiencies prior to departure
Due 27 December 2006
Resolved 27 December 2006
Resolution: Received letter from Master attesting that a copy of the Coast Pilot 5 is onboard vessel.
Navigation › Piloting/Steering › Marine Charts
Issued 27 December 2006 Resolved
Vessel does not have current copies of marine charts onboard. Prior to getting underway vessel to have onboard.
Action required: 17 - Rectify deficiencies prior to departure
Due 27 December 2006
Resolved 27 December 2006
Resolution: Received letter from Master attesting that copies of current marine charts are onboard vessel.
Fire Fighting
Issued 28 May 1998 Resolved
UPDATE / SERVICE ALL PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 28 May 1998
Resolved 28 May 1998
Deck/Cargo
Issued 28 May 1998 Resolved
PROVIDE MACHINERY GUARDS FOR ALL ROTATING MACHINERY IN THE ENGINE ROOM.
Condition: Unknown
Due 28 May 1998
Resolved 28 May 1998
Navigation
Issued 28 May 1998 Resolved
PROVE COMPLIANCE WITH 33 CFR 154.71(a)(1) FOR THE GOLDSTAR RADAR ONBOARD.
Condition: Unknown
Due 28 May 1998
Resolved 28 May 1998
Navigation
Issued 28 May 1998 Resolved
PROVIDE CURRENT COPY OF COAST GUARD LIGHT LIST.
Condition: Unknown
Due 28 May 1998
Resolved 28 May 1998
Navigation
Issued 28 May 1998 Resolved
PROVIDE CURRENT MARINE CHARTS UPDATED WITH BROADCAST NOTICE TO MARINERS.
Condition: Unknown
Due 28 May 1998
Resolved 28 May 1998
Electrical
Issued 28 May 1998 Resolved
SECURE THE BATTERY IN THE ENGINE ROOM.
Condition: Unknown
Due 28 May 1998
Resolved 28 May 1998

Ownership record