Records from 2012 to 2025. Most recent: inspection, 16 September 2025.
Documentation record
Registered dimensions (L × B × D)130.0 ft × 40.0 ft × 10.7 ft
Registered tonnagegross 467 / net 467
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderNATIONAL MAINTENANCE & REPAIR INC · HARTFORD, IL, UNITED STATES · built 2013
Hull materialSteel
PropulsionNot recorded
Hull shapeBox
Hull configurationMonohull
Hailing portST LOUIS, MO
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 31 July 2026 · expires 31 August 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it467 - Simplified, Gross Ton
467 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 17
16 September 2025
Periodic Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 8231549
11 September 2024
Annual Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 8000776
7 September 2023
Internal Structural Exam · Cargo Tank Internal · Drydock Exam · Administrative Inspection · COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7786973
21 July 2023
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 7748204
28 June 2022
MTSA Verification · Periodic Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 7492370
17 August 2021
Annual Inspection · MTSA Verification · Administrative Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 7289222
21 May 2020
MTSA Verification · Annual Inspection · Administrative Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6963419
5 October 2019
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6839439
5 September 2019
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6804533
24 June 2019
Internal Structural Exam · Administrative Inspection · COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6724278
16 September 2018
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6542136
20 June 2018
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6445060
20 July 2017
Administrative Inspection · Annual Inspection · MTSA Verification · Deficiency Check
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6215270
7 June 2016
Periodic Inspection · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5896299
28 May 2015
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 5138210
27 April 2015
Damage Survey · Annual Inspection · Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 5142915
18 May 2012
Initial Certification · Construction Oversight · Plan Review (Other than "T") · MTSA Verification · COI Inspection · Administrative Inspection · Initial Construction-Excluding Oversight
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4314858
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 11 September 2024
Resolved
Periodic tests and inspection must be made of the main and auxiliary machinery, boilers, and other equipment as prescribed in this part.
The inspections and tests must ensure that the equipment and associated structure are in satisfactory operating conditions and fit for the service for which they are intended.
MI observed an exhaust leak on the piping for the auxiliary generator. Repair exhaust leak by replacing existing piping with new flexible flanged piping.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 October 2024
Resolved 6 October 2024
Resolution: New flexible exhaust pipe installed.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 11 September 2024
Resolved
Electrical installations on vessels must ensure protection of passengers, crew, other persons, and the vessel from electrical hazards.
MI observed a light fixture not properly installed in the work area near the auxiliary generator. Mount light fixture properly to the overhead.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 October 2024
Resolved 6 October 2024
Resolution: Light fixture remounted to ceiling.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 21 July 2023
Resolved
Piping, including valves, pipe fittings and flanges, conveying vapors, gases or liquids whose temperature exceeds 150 deg F, shall be suitably insulated where necessary to preclude injury to personnel.
Exhaust piping at turbo on generator prime mover was missing lagging and had excessive exhaust leak. Operator shall make repairs to satisfaction of attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 August 2023
Resolved 31 July 2023
Resolution: Repaired exhaust leak at V-band and renewed lagging material around missing locations.