MAURY USCG vessel records Sign in
← All vessels

PAPA JOE I

PAPA JOE I is a 1977 passenger vessel (inspected). The Coast Guard has recorded 51 inspections since 1983, most recently in September 2025, along with 22 deficiencies and 2 casualty investigations between 2014 and 2019.

Records from 1983 to 2025. Most recent: inspection, 17 September 2025.

Built
1977
Last inspected
17 September 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDK6341
Flag
UNITED STATES
367381540 (licence lapsed)
Maury page id
psix-49118

Inspections, by type

…with no type recorded7
Years with a record 38 calendar years (1983–2025)
The 51 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)45.0 ft × 15.0 ft × 5.6 ft
Registered tonnagegross 28 / net 19
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderNEUVILLE BOAT WORKS INC · LOREAUVILLE LA, UNITED STATES · built 1977
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portBATON ROUGE, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 13 January 2026 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it28 - Regulatory (Subpart C or D), Gross Ton
19 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDK6341MMSI 367381540 · cancelled · voluntarily equipped · granted 5 February 2019, cancelled 11 September 2025 · licensed under a name not among this hull’s recorded names (not shown)
WDE6542MMSI 367381540 · expired · voluntarily equipped · granted 22 October 2008, cancelled 22 December 2018 · licensed under a name not among this hull’s recorded names (not shown)
WCY7908MMSI not assigned · expired · voluntarily equipped · granted 8 December 1998, cancelled 7 February 2009
WBD8207MMSI not assigned · expired · compulsorily equipped · granted 8 January 1997, cancelled 28 April 2007
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

PETER J Towing Vessel · MISLE 202059 · 5 October 2019 · activity 6839439CF22 Tank Barge · MISLE 1167358 · 5 October 2019 · activity 6839439

Inspection history · 51

17 September 2025 Examination of Repairs · Drydock Exam
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 8236119
3 July 2024 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7938923
9 March 2023 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7640046
28 June 2022 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7465295
6 September 2021 Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7305628
26 April 2021 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7171236
12 April 2021 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7173450
9 April 2020 MTSA Verification · Drydock Exam · COI Inspection · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6928667
5 October 2019 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6829633
5 October 2019 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6839439
14 February 2019 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6622842
15 March 2018 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6372305
23 March 2017 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6106622
29 April 2016 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5862237
7 March 2014 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4807729
10 February 2012 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4239169
7 February 2011 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3940925
25 January 2011 DAPI Audit · Examination of Repairs · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3928458
16 December 2009 Damage Survey · COI Inspection · Examination of Repairs · Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3648786
30 March 2009 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3438952
4 April 2008 Annual Inspection · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3174770
1 February 2007 Administrative Inspection · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2863254
1 February 2006 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2577532
21 December 2004 Hull Examination · Annual Inspection
Physical examination · MIDET WEST DETAIL · USCG Heartland District (CGD-H) · Activity 2262430
20 July 2004 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2141589
9 April 2004 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2044095
23 December 2003 Examination of Repairs · Periodic Inspection
Physical examination · MIDET WEST DETAIL · USCG Heartland District (CGD-H) · Activity 1968708
11 December 2002 Annual Inspection
Physical examination · MIDET WEST DETAIL · USCG Heartland District (CGD-H) · Activity 1715197
3 December 2001 COI Inspection
Physical examination · MIDET WEST DETAIL · USCG Heartland District (CGD-H) · Activity 1457035
9 February 2001 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1430974
10 December 1999 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1361264
7 January 1999 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 809729
6 January 1999 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 809722
3 December 1998 Hull Examination · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1438779
6 May 1998 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1451290
14 May 1997 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1427372
14 May 1996 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1398451
7 June 1995 Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1358801
14 June 1994 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1435499
21 May 1993 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1452949
13 July 1992 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 950626
29 May 1992 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1401625
24 June 1991 Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1228879
22 May 1990 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 912146
14 June 1989 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1206672
15 June 1988 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 893039
22 June 1987 Hull Examination · COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1324060
25 June 1986 Re-Inspection · Credit Drydock
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 984786
28 June 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 983351
10 July 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 978924
19 May 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1273928

Deficiency record · 22

02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 9 March 2023 Resolved
At each initial and subsequent inspection for certification the marine inspector shall view the vessel afloat and shall conduct the following tests and inspections of the hull structure and its appurtenances: (1) Examine all accessible parts of the exterior and interior of the hull, watertight bulkheads, and weather deck. Upper longitudinals in engine room compartment found with cracked welds. Grind and renew to satisfaction of Marine Inspector. 46 CFR 176.25-5(a)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 March 2023
Resolved 13 March 2023
Resolution: Received, reviewed, and accepted documentation from vessel rep showing repairs made to cracks found in upper longitudinals.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 9 March 2023 Resolved
Where the exhaust piping passes through watertight bulkheads the watertight integrity of the bulkhead shall be maintained. Multiple cracks found on weld seam where exhaust piping passes through watertight bulkhead between lazarette and engine compartment. Grind and renew to satisfaction of Marine Inspector. 46 CFR 182.15-20 (d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 March 2023
Resolved 13 March 2023
Resolution: Received, reviewed, and accepted documentation from vessel rep showing repairs made to cracks found in exhaust gas piping.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 9 March 2023 Resolved
At each initial and subsequent inspection for certification the marine inspector shall view the vessel afloat and shall conduct the following tests and inspections of the hull structure and its appurtenances: (1) Examine all accessible parts of the exterior and interior of the hull, watertight bulkheads, and weather deck. Through-hole for cables in forward engine room and lazarette bulkhead not sealed, effecting watertight integrity of bulkhead. 46 CFR 176.25-5(a)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 March 2023
Resolved 13 March 2023
Resolution: Received, reviewed, and accepted documentation from vessel rep showing all through-holes in the watertight bulkhead sealed.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 9 March 2023 Resolved
Electrical equipment on a vessel must be installed and maintained to: (b) Protect passengers, crew, other persons, and the vessel from the electrical hazards, including fire, caused by or originating in electrical equipment shock. Port engine outboard bus terminal found with missing plastic shield protector. 46 CFR 183.200(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 March 2023
Resolved 13 March 2023
Resolution: Received, reviewed, and accepted documentation from vessel rep showing plastic shield protector installed on outboard bus terminal.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 6 September 2021 Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull, protection against fire, means of escape in case of a sudden unexpected casualty, guards and rails in hazardous places, ventilation of enclosed spaces, and necessary facilities for passengers and crew. 46CFR177.100
Action required: 60 - Rectify deficiencies prior to movement
Resolved 10 September 2021
Resolution: Survey recieved and repairs to aft cabin door hinges were completed and to satisfaction of MI.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 April 2020 Resolved
As part of a drydock exam, propellers must be in a satisfactory condition for the service intended. The starboard propeller was found to have deep pitting at the root on two of the blades. Within 14 days, correct to satisfaction of USCG Marine Inspector. (46 CFR 176.15-5 Old T)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 April 2020
Resolved 20 April 2020
Resolution: Stbd prop satisfactorily replaced.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 25 January 2011 Resolved
Provide a proposal for meeting the "not under command" requirements in NAV Rules No. 27.
Action required: 705 - Other - as specified
Due 25 March 2011
Resolved 16 March 2011
Resolution: Company rep. provided a proposal for meeting the "not under command" requirements in NAV Rules No. 27.
Engineering
Issued 3 December 2001 Resolved
INSULATE ENGINE EXHAUST ALL WAY TO WHERE WATER ENTERS PIPING.
Condition: Unknown
Due 6 December 2001
Resolved 12 December 2001
Engineering
Issued 3 December 2001 Resolved
REPLACE FUEL TANK VENT FLEXIBLE HOSE AND INSTALL WITH DOUBLE CLAMPS.
Condition: Unknown
Due 6 December 2001
Resolved 12 December 2001
Electrical
Issued 3 December 2001 Resolved
REPAIR OIL LEAK ON GENERATOR.
Condition: Unknown
Due 6 December 2001
Resolved 12 December 2001
Construction/Loadline
Issued 3 December 2001 Resolved
REPLACE SECTIONS OF FLEX HOSE IN BILGE PIPING WITH REQUIRED FERROUS MATERIAL.
Condition: Unknown
Due 3 January 2002
Resolved 3 December 2001
Engineering
Issued 3 December 2001 Resolved
GOUGE AND REWELD CRACKED WELD AT PORT FWD FUEL TANK SUPPORT.
Condition: Unknown
Due 6 December 2001
Resolved 12 December 2001
Fire Fighting
Issued 3 December 2001 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 3 January 2002
Resolved 3 December 2001
Lifesaving
Issued 9 February 2001 Resolved
REPAIR LEAK ON OIL PRESSURE GAUGE TO GENERATOR.
Condition: Unknown
Due 12 February 2001
Resolved 12 February 2001
Lifesaving
Issued 9 February 2001 Resolved
REMOVE OIL-SOAKED AND WASTED MASONITE PEG BOARD FROM FORWARD BULKHEAD OF ENGINE ROOM.
Condition: Unknown
Due 12 February 2001
Resolved 12 February 2001
Lifesaving
Issued 9 February 2001 Resolved
CLEAN DEBRIS AND OIL FROM GENERATOR COOLING VENTS.
Condition: Unknown
Due 12 February 2001
Resolved 12 February 2001
Lifesaving
Issued 9 February 2001 Resolved
RE-ROUTE CRANKCASE VENTILATOR DRAIN HOSE SO THAT IT DOES NOT DISCHARGE ON TOP OF GENERATOR.
Condition: Unknown
Due 12 February 2001
Resolved 12 February 2001
Accommodation/Occupational Safety
Issued 6 January 1999 Resolved
REPIAR BROKEN WINDOW IN WHEEL HOUSE.
Condition: Unknown
Due 6 January 1999
Resolved 6 January 1999
Construction/Loadline
Issued 3 December 1998 Resolved
INSTALL CHAINS ON ALL MANHOLE COVERS,
Condition: Unknown
Due 11 February 1999
Resolved 11 February 1999
Electrical
Issued 3 December 1998 Resolved
REPLACE GENERATOR FUEL LINE AND FITTINGS WITH THE REQUIRED TYPE.
Condition: Unknown
Due 3 December 1998
Resolved 3 December 1998
Electrical
Issued 3 December 1998 Resolved
REXPAIR GENERATOR TO WORKING ORDER.
Condition: Unknown
Due 3 December 1998
Resolved 3 December 1998
Electrical
Issued 3 December 1998 Resolved
CAP DEAD-END WIRES UNDER BRIDGE CONSOLE.
Condition: Unknown
Due 3 December 1998
Resolved 3 December 1998

Casualty record · 2

12 July 2014Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4924418
5 October 2019Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 6839439
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.