MAURY USCG vessel records Sign in
← All vessels

VALARIS DPS-5

VALARIS DPS-5 is a 2012 mobile offshore drilling unit. The Coast Guard has recorded 19 inspections since 2012, most recently in March 2022, along with 17 deficiencies.

Records from 2012 to 2022. Most recent: inspection, 29 March 2022.

Built
2012
Last inspected
29 March 2022
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8770522 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
1177200
Flag
LIBERIA
—
Maury page id
psix-1177200

Inspections, by type

…with no type recorded3
Years with a record 9 calendar years (2012–2022)
The 19 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records itNot recorded
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

CROSBY GUARDIAN Towing Vessel · MISLE 999174 · 11 March 2016 · activity 5832618HARVEY CONDOR Industrial Vessel · MISLE 1276343 · 11 March 2016 · activity 5832618

Inspection history · 19

29 March 2022 COC-MODU Renew · ISPS Exam · Ballast Water Examination
Physical examination · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7421513
28 January 2022 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7388606
12 January 2022 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7379497
12 May 2020 COC-MODU Annual · In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6955188
26 April 2019 COC-MODU Annual
Type not classified · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 6662813
7 May 2018 COC-MODU Renew
Type not classified · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6442586
9 February 2018 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6378628
12 July 2017 COC-MODU Annual
Type not classified · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6208038
9 July 2017 In-Service Inspection
Physical examination · USCG Heartland District · USCG Heartland District (CGD-H) · Activity 6202783
15 October 2016 In-Service Inspection
Physical examination · USCG Heartland District · USCG Heartland District (CGD-H) · Activity 6022996
11 May 2016 COC-MODU Renew
Type not classified · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5913719
11 March 2016 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5832618
19 December 2015 In-Service Inspection
Physical examination · USCG Heartland District · USCG Heartland District (CGD-H) · Activity 5784866
3 October 2014 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4998200
8 May 2014 Administrative Inspection · Deficiency Check · COC-MODU Renew
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4852980
24 March 2014 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4822266
22 May 2012 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4318467
22 May 2012 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4318476
10 May 2012 COC-MODU Renew
Type not classified · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4307908

Deficiency record · 17

11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 26 April 2019 Resolved
Lifeboat #4 battery for secondary means of start failed to start lifeboat engine. Replace battery and ensure lifeboat has two means starting.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 May 2019
Resolved 24 May 2019
Resolution: Received workorder showing completed battery install
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 26 April 2019 Resolved
Accumulator for rescue boat davit potentially has significant corrosion. Ensure accumulator meets LSA requirements for bottle.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 May 2019
Resolved 24 May 2019
Resolution: Accumulator bottle was replaced with photos sent in.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 7 May 2018 Resolved
Emergency generator failed to automatically take the power load on first attempt.
Action required: 705 - Other - as specified
Due 21 May 2018
Resolved 12 June 2018
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 7 May 2018 Resolved
Air pressure regulators in lifeboats were incorrectly set.
Action required: 705 - Other - as specified
Due 21 May 2018
Resolved 12 June 2018
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 7 May 2018 Resolved
Multiple crewmembers were missing TWIC and Medical cards.
Action required: 705 - Other - as specified
Due 21 May 2018
Resolved 12 June 2018
Operations/Management › Drills/Instruction › Fire
Issued 9 May 2014 Resolved
Fire boundaries were not maintained and entry/approach methods needed improvement. Conduct drills and training to improve knowledge and firefighting techniques. Intend to witness drills during a subsequent Coast Guard visit. Cite 89 MODU 14.11.4. Action 50c.
Action required: 705 - Other - as specified
Due 9 June 2014
Resolved 7 June 2014
Resolution: Witnessed follow-up drill on 07Jun14. There was notable improvement but the crew still needs to increase proficiency. Discussed same with the Master. Cleared requirement as of 07Jun.
Operations/Management › Drills/Instruction › Abandon Ship
Issued 9 May 2014 Resolved
Muster took excessive time. Confusion w/name of one 3rd party hand resulted in him being counted when he was missing. Conduct drills/training to improve muster process & ensure all personnel are accounted for in timely manner. Improve muster lines to facilitate quick personnel counts. Intend to witness drills during a subsequent CG visit. Cite 89 MODU 14.11.2 & 4, 10.6.8 & 10.3.6. Action 50c.
Action required: 705 - Other - as specified
Due 9 June 2014
Resolved 7 June 2014
Resolution: Witnessed follow-up drill on 07Jun14 with notable improvement.
Lifesaving › Launching Appliances › Winch
Issued 9 May 2014 Resolved
The bow limit switch for Lifeboat 4 was found to be inoperable during testing. Prove proper operation of this limit switch. Cite 89 MODU 10.6.1, 83 SOLAS III/48.2.5. Action 40a,b,c.
Due 16 May 2014
Resolved 13 May 2014
Resolution: Received documentation showing satisfactory completion.
Lifesaving › Launching Appliances › Falls
Issued 9 May 2014 Resolved
Falls cable for Lifeboat 4 was found to be improperly spooled (bird-nested) on the outboard winch drum. This problem was documented in the 3rd party lifesaving report and shown as corrected. Re-spool the fall cable onto the drum and ensure that there are not additional underlying problems causing this fall to improperly 'lay' onto the drum. Cite 89 MODU 10.6.1, 83 SOLAS III/48.2.2. Action 40a,b,c.
Due 16 May 2014
Resolved 18 May 2014
Resolution: Received documentation showing satisfactory completion.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 9 May 2014 Resolved
Local release instructions for the CO2 systems in the CO2 Room and the E-Gen Cabinet were very difficult to follow. Post simplified instructions and labeling of the systems to facilitate local release by a member of the crew at any experience level. Cite 89 MODU 9.5.1.1.2, 91 SOLAS II-2/5.1.7. Action 50a,b,c.
Due 9 June 2014
Resolved 13 May 2014
Resolution: Received documentation showing satisfactory completion.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 9 May 2014 Resolved
A-60 Stairwell doors observed to be installed w/out latching mechanisms on the 8500-Series MODUs. Doors were installed w/out latches contrary to door type approval. ENSCO is aware of the problem/taking steps to correct on the 8500-Series fleet. Install required mods to bring the doors into compliance w/door type approval. Also verify Galley-to-Messdeck door. Cite 89 MODU 9.2.3. Due 90-days.
Due 9 August 2014
Resolved 22 December 2014
Resolution: New stairwell doors installed and latch installed on Galley-to-Messdeck doors. Materials lead time delayed the work scope but routine updates were provided by ENSCO/Master.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 9 May 2014 Resolved
Crew was unable to demonstrate operation of the Galley roll-down fire shutters and the 3rd party servicing report did not list the shutters as being tested. Prove proper operation/automatic closure of the shutters with removal of the thermal links (to simulate release during a fire). Cite 89 MODU 9.1.8. Action 16a,b,c.
Due 23 May 2014
Resolved 20 May 2014
Resolution: Received documentation showing satisfactory completion.
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 9 May 2014 Resolved
Numerous exterior vent closures around the Accommodations were found to be inaccessible for closure. Provide fixed ladders or alternate means of closure for elevated/ inaccessible closures for systems without fire dampers installed. Cite 89 MODU 9.2.7. Action 50a,b,c.
Due 9 June 2014
Resolved 28 June 2014
Resolution: Received documentation showing satisfactory completion. Routine correspondence for intended correction method and work scope. Dedicated portable ladders were fabricated & stowed on each deck.Ladder ''''hangers'''' were installed at each vent closure.
Fire Fighting › Means of Escape › Handrails/Handholds
Issued 9 May 2014 Resolved
The ROV Control Van was found to have interior steps to access the elevated escape hatch but no exterior steps or ladder. Install exterior means (steps/grab rail) to facilitate safe egress through the hatch. Cite 89 MODU 9.3.1.3. Action 50a,b,c.
Due 9 June 2014
Resolved 16 May 2014
Resolution: Received documentation showing satisfactory completion.
Documentation › Certificates/Documents › International Air Pollution Prevention Certificate
Issued 9 May 2014 Resolved
The Supplement to the International Air Pollution Prevention (IAPP) Certificate was not attached or onboard. Master was able to obtain a 'Copy' from ABS. Provide correct Supplement for 'attachment' to the IAPP onboard. Cite 08 MARPOL VI/6. Action 16a,b,c.
Due 23 May 2014
Resolved 19 May 2014
Resolution: Received documentation showing satisfactory completion. Corrected Supplement was provided.
Lifesaving › Embarkation Appliances/Stations › Accessability
Issued 10 May 2012 Resolved
Embarkation lighting at lifeboats 1, 2 and 3 is not operating properly. Vessel is required to repair lighting for proper operation and lighting of embarkation areas.
Action required: 705 - Other - as specified
Due 1 June 2012
Resolved 8 May 2014
Resolution: Lighting is working w/08May14 exam. Cleared this old deficiency.
Lifesaving › Lifeboat › View (at steering position)
Issued 10 May 2012 Resolved
The coxswain's viewing window in lifeboat #1 is broken, prohibiting adequate visibility from the steering station. Vessel is required to replace window for adequate visibility.
Action required: 705 - Other - as specified
Due 8 June 2012
Resolved 8 May 2014
Resolution: Window in satisfactory condition w/08May14 exam. Cleared this old deficiency.

Ownership record