MAURY USCG vessel records
← All vessels

HARVEY CONDOR

HARVEY CONDOR is a 2014 industrial vessel. The Coast Guard has recorded 30 inspections since 2016, most recently in March 2025, along with 41 deficiencies — 1 with no resolution recorded — and 6 casualty investigations between 2014 and 2024.

Records from 2014 to 2025. Most recent: inspection, 27 March 2025.

Built
2014
Last inspected
27 March 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 2016.

Inspection record

Last inspected 27 March 2025
…with no type recorded5
…past their stated due date1
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9582300
1276343
Flag
UNITED STATES
Maury page id
psix-1276343

Documentation record

Registered dimensions (L × B × D)262.1 ft × 62.0 ft × 23.0 ft
Registered tonnagegross 3,498 / net 1,549
ITC dimensions (L × B × D)262.1 ft × 62.0 ft × 23.0 ft
ITC tonnagegross 3,498 / net 1,549
BuilderTHOMA-SEA MARINE CONSTRUCTORS LLC · LOCKPORT, LA, UNITED STATES · built 2014
Hull materialSteel
PropulsionDiesel Electric
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 5 February 2026 · expires 28 February 2027
Service, as the file records itIndustrial Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it3498 - Convention (Subpart B), Gross Ton
5150 - Dead Weight, Gross Ton
1549 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

CROSBY GUARDIAN Towing Vessel · MISLE 999174 · 11 March 2016 · activity 5832618VALARIS DPS-5 Mobile Offshore Drilling Unit · MISLE 1177200 · 11 March 2016 · activity 5832618

Inspection history · 30

27 March 2025 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8100548
27 November 2024 Damage Survey · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8040554
26 November 2024 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8062672
18 September 2024 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8005170
10 September 2024 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8000466
22 August 2024 In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7987652
18 August 2024 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8023293
6 June 2024 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7948494
3 June 2024 COI Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7926229
9 May 2024 COI Inspection · Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7909140
10 July 2023 Damage Survey · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7739015
10 July 2023 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7765843
14 June 2023 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7714432
20 June 2022 Deficiency Check · Periodic Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7482398
21 March 2022 Internal Structural Exam · Drydock Exam · Cargo Tank Internal
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7415459
26 July 2021 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7268122
3 August 2020 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7023150
29 April 2020 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6945768
20 April 2020 Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6941554
17 April 2019 MARPOL Annex II Examination · DAPI Audit · COI Inspection · Administrative Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6663916
9 April 2019 Cargo Tank Internal · Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6659541
30 July 2018 Annual Inspection · MARPOL Annex I Examination · MTSA/ISPS Verification · Administrative Inspection · MARPOL Annex VI Survey · MARPOL Annex II Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6495200
9 May 2018 In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6416311
3 May 2018 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6404545
1 November 2017 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6299357
11 August 2017 MTSA Verification · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6237310
12 April 2017 Drydock Exam · Cargo Tank Internal · Administrative Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6123246
31 August 2016 MTSA/ISPS Verification · Administrative Inspection · MARPOL Annex II Examination · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5988476
13 March 2016 Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5835875
11 March 2016 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5832618

Deficiency record · 41

06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 27 March 2025 Resolved
Cargo tank relief valve setting shall be a minimum of 0.02MPA gauge (2.9 PSI). P/V relief valves for methanol tanks were set at 2.0PSI. Setting should meet IBC Code prior to carrying methanol. IBC Code 15.12.4 / 705c
Action required: 705 - Other - as specified
Due 27 March 2025
Resolved 28 March 2025
Resolution: PVs were installed on both Port and Starboard Methanol tanks with a 2.9PSI setting IAW with IBC code. Documentation within deficiencies documents tab.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 27 March 2025 Resolved
The condition of the ship shall be maintained to conform to the convention to ensure the ship will remain fit to proceed to sea without harm to the environment. OCM/OWS will not get below 15ppm. Prior to using OWS. MARPOL 73/78 2020 cons. Annex I / Reg.6.4.1
Action required: 705 - Other - as specified
Due 27 March 2025
Resolved 1 May 2025
Resolution: Recieved tech report & documentation proving operation of OWS.
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage
Issued 27 March 2025 Resolved
Every ship of 400GT shall have a garbage record book. Onboard garbage record book was outdated per present Convention. A new garbage record book was placed on the onboard to meet Convention while MI’s were still onboard. MARPOL 73/78 2020 cons. Annex V / Reg.10.3
Action required: 10 - Deficiency Rectified
Due 27 March 2025
Resolved 27 March 2025
Resolution: A new garbage record book was placed on the onboard to meet Convention while MI’s were still onboard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 November 2024 Resolved
A survey, either general or partial, according to the circumstances, shall be made every time an accidents occurs or a defect is discovered which affects the safety of the vessel or the efficacy or whenever any important repairs or renewals have been made. Vessel experienced Vessel experienced a loss of #2 generator while transiting outbound Port Fourchon. Vessel is to determine cause of the generator failure and conduct repairs to the satisfaction of the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 December 2024
Resolution: Recieved ABS report stating satisfactory repair.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 September 2024 Resolved
Electric installations on vessels must ensure maintenance of services necessary for safety under normal and emergency conditions. Vessel's #2 generator reported to be non-operational due to equipment failure. Vessel is currently offshore for storm avoidance and shall transit from its current position to its home port of Port Fourchon, LA, to complete repairs when safe to do so upon conclusion of inclement weather. Verify repairs and proper operation of generator to the satisfaction of Classification Society (ABS) and Coast Guard OCMI prior to operations. 46CFR 96.05-1(a), 46CFR 111.01-1(a)(1)
Action required: 705 - Other - as specified
Resolved 29 October 2024
Resolution: Vessel rep provided ABS report stating No.2 generator was tested to the satisfaction of surveyor and repair involving remote controls of solenoid actuators for port and starboard fuel oil daily service tanks repaired.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 August 2024 Resolved
Electrical installations within hazardous locations must conform with the standards acceptable by the Organization. Electrical installations within hazardous zones in OSVs that carry liquids with <60 degree C flashpoint must be explosion proof or intrinsically safe. Cable fitting for #6 Port Drill vent fan and butterfly valve for #12 Methanol Priming pump on cargo deck are not intrinsically safe.
Action required: 66 - Prior to drilling or production operations
Due 29 August 2024
Resolved 5 September 2024
Resolution: Electrical installations properly fixed and verified by ABS.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 6 June 2024 Resolved
Fire detection systems must meet the applicable requirements of 46CFR76. The vessel's fire detection panel contained multiple outstanding faults. Rectify deficiency prior to the vessel's departure. 46CFR95.05-1(a)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 June 2024
Resolution: Third party technicians conducted satisfactory tests of the vessel's fire control panel, deficiency cleared.
01 - Certificates & Documentation › 013 - Documents › Unattended Machinery Spaces (UMS) Evidence
Issued 6 June 2024 No resolution recorded
Design Verification and Periodic Safety test procedure documents approved by the Coast Guard must be retained aboard the vessel. Vessel O/O was unable to provide Coast Guard approved DVTPs/PSTPs. 46CFR91.25-35(a) 46CFR61.40-1(c)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2024 — due date passed with no resolution recorded
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 6 June 2024 Resolved
In respect of ships other than chemical tankers or liquefied gas carriers certified to carry noxious liquid substances in bulk identified in chapter 17 of the International Bulk Chemical Code, the Administration shall establish appropriate measures based on *resolution A.673(16). The vessel does not posses a valid Certificate of Fitness or International Pollution Prevention Certificate and is prohibited from NLS carriage. MARPOL 73/78 Annex II/11.2
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 27 March 2025
Resolution: The vessel had been issued its Certificate of Fitness on 22AUG24 by MSU Houma. MISLE activity #7987652.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 6 June 2024 Resolved
Paint lockers and similar components must be constructed of steel or be wholly lined with steel. The vessel was outfitted with an aluminum paint locker. 46CFR127.220(c)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2024
Resolved 27 March 2025
Resolution: Verified removal of aluminum paint locker. Vessel now has steel paint locker.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 6 June 2024 Resolved
The general construction of the vessel shall be such as to minimize fire hazards insofar as is reasonable and practicable. Missing structural fire protection was identified under the deck plate in the aft port quarter of the engine room. 46CFR92.05-1(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2024
Resolved 7 August 2024
Resolution: Received photograph evidence of missing insulation, deficiency cleared.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 June 2024 Resolved
The material, design, construction, workmanship, and arrangement of auxiliary machinery must be equivalent to ABS Steel Vessel Rules. Murphy switches on both #2 and #4 engine room generators were found unsupported. 46CFR90.20-1(a) 46CFR58.05-1
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2024
Resolved 7 June 2024
Resolution: Murphy switches were satisfactorily supported on both generators, deficiencies cleared.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 June 2024 Resolved
The material, design, construction, workmanship, and arrangement of auxiliary machinery must be equivalent to ABS Steel Vessel Rules. The check valve for generator cooling water was punctured and actively leaking, ivo the port aft quarter of the engine room. 46CFR90.20-1(a) 46CFR58.05-1
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2024
Resolved 11 July 2024
Resolution: O/O provided a picture via e-mail of a newly installed check valve, deficiency cleared.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 June 2024 Resolved
Valves certified in accordance with subpart 50.25 of this subchapter are acceptable for use in piping systems. Missing butterfly valve handles were identified on the #4 generator raw water piping and forward tank farm piping system.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2024
Resolved 11 July 2024
Resolution: O/O provided a picture via e-mail of a newly installed butterfly valves, deficiency cleared.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 June 2024 Resolved
The material, design, construction, workmanship, and arrangement of auxiliary machinery must be equivalent to ABS Steel Vessel Rules. The #4 generator exhaust heat pipe guard was not intact. 46CFR90.20-1(a) 46CFR58.05-1
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2024
Resolved 11 July 2024
Resolution: O/O provided an IAS job completion report of the exhaust line, deficiency cleared.
99 - Other › N/A - No Subsystem › Other (SOLAS operational)
Issued 29 May 2024 Resolved
Seafarers employed or engaged in any capacity on board a ship which is required to comply with the previsions of the ISPS Code on the business of that ship as part of the ship's complement without designated security duties shall, before being assigned to any shipboard duties shall .2 be required to provide evidence of having achieved the required standard of competence to undertake the task, duties and responsibilities listed in column 1 of table A-VI/6-1. Vessel has 03 members whom have not completed security awareness training these members do stand security duties (gangway watch). 705 - members can not stand security related duties until security awareness complete. STCW CODE A-VI/6
Action required: 705 - Other - as specified
Due 5 June 2024
Resolved 6 June 2024
Resolution: The (03) members missing security training were able to provide documentation during the inspection, deficiency cleared.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 29 May 2024 Resolved
Grade B or C liquids. Cargo tanks in which Grade B or C liquids are to be transported shall be fitted with a individual pressure-vacuum relief valves which shall extend to a reasonable height above the weather deck. Tank venting system for methanol tanks are currently installed at a height of 2 meters above the main deck increase venting height on venting for these tanks IAW IBC Code. 705- vessel is restricted from carrying methanol until complete.
Action required: 705 - Other - as specified
Due 5 July 2024
Resolved 6 June 2024
Resolution: Adjusted vent heights were verified, however the vessel must still provide proof that it meets A.673 prior to carrying IBC chapter 17 cargoes. A new 835 was issued.
99 - Other › N/A - No Subsystem › Other (SOLAS operational)
Issued 29 May 2024 Resolved
The convention shall apply to seafarers serving on board seagoing ships entitled to fly the flag of a party. Vessel is employing 01 member whom does not have MMC or medical card on a STCW applicable vessel. STCW article III
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 June 2024
Resolved 6 June 2024
Resolution: Member who was missing valid MMC was able to provide sufficient documention, deficiency cleared.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 29 May 2024 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 10 - Deficiency Rectified
Due 30 May 2024
Resolved 30 May 2024
Resolution: Vessel conducted EPIRB test with MIs, and will start logging monthly test
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 29 May 2024 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. 1. Fire structural door in thruster room,2. Water Mist automatic operation not working, 3. Water mist system raptured hose (at water mist pump), 4. Primary fire pump electric motor housing deteriorated, 5. rotation guards on primary fire pump and bilge ballast need fix, 6. Port Aft generator room is missing insulation was not put back after vessels DD, 7. bow-thruster switch missing and electronic controlling not watertight, 8. broken strobe located in tank farm STBD side. 9. replace gasket on watertight door going into AFE room, 10. emergency exit PORT side stern room does not.11. Bilge pump valve handles broken STBD bilge manifold, 12. Oily water separator pipe wasted needs replacement, 13. Bilge suction was not functioning, 14. Anchors' brakes were being replaced.
Action required: 705 - Other - as specified
Due 30 May 2024
Resolved 7 June 2024
Resolution: All systems were tested/recitified in the presence of the OCMI/ABS, deficiency cleared.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 9 May 2024 Resolved
Except as provided in paragraphs (b) through (g) of this section, each vessel must undergo drydock, internal structural, and cargo tank internal examinations. During DD/ISE/CTIE exam the following worklist items were developed; 1. make repairs to FWD peak valve so that valve 2. Fix cracked welds in #4 and #3 port ballast tanks
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 June 2024
Resolved 20 May 2024
Resolution: Vessel has completed all repairs from their worklist items identified during their Dry dock exam.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 10 July 2023 Resolved
No repairs or alterations to the hull, machinery, or equipment that affects the safety of the OSV, may be made without notice to the OCMI. On 10JUL23 a failure occurred on the vessel's raw water cooling system causing high temperature alarms on the vessel's propulsion machinery. Provide a repair plan, and technician's report attesting to satisfactory operation of the vessel's raw water cooling system. 46 CFR 126.150
Action required: 17 - Rectify deficiencies prior to departure
Due 10 July 2023
Resolved 10 July 2023
Resolution: Provided documentation through technicians report of satisfactory repairs.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 June 2022 Resolved
All electrical installations in the HAZ locations must be either intrisically safe or explosion proof. A cable on the Port 11 Area was able to move inside the junction box and the junction box was not sealed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 July 2022
Resolved 29 July 2022
Resolution: MI verified the wiring.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 21 June 2022 Resolved
Vessel shall have all fire equipment operational, ready, and maintained. SCBA refill station had not been tested as required.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 July 2022
Resolved 16 August 2022
Resolution: SCBA Refill station has been re-installed and tested by Third Party.
10 - Safety of Navigation › N/A - No Subsystem › Bridge Navigation Watch Alarm System (BNWAS)
Issued 3 August 2020 Resolved
BNWAS SYSTEMS ARE REQUIRED TO BE EQUIPED WITH AUDIBLE ALARMS. VLS BNWAS AUDIBLE ALARM IS INOPERABLE. VSL MUST PROVIDE AN OPERABLE AUDIBLE ALARM ON THE BRIDGE FOR THE BNWAS SYSTEM. SOLAS14 (V) REG 19
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 August 2020
Resolution: Vsl rep forwarded an email with a video file of an operation BNWAS speaker.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 April 2019 Resolved
LIFE JACKET LIGHTS EXPIRED, LIGHTS MUST NOT BE EXPIRED 46 CFR 133.70
Action required: 10 - Deficiency Rectified
Due 17 April 2019
Resolved 17 April 2019
Resolution: FIXED WHILE ON BOARD
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boat inventory
Issued 17 April 2019 Resolved
NON-OPERABLE SEARCHLIGHT ON RESCUE BOAT, PROVIDE WORKING SEARCHLIGHT 46 CFR 133.175
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 May 2019
Resolved 26 April 2019
Resolution: [name withheld] RASMUSSEN ATTENDED
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 17 April 2019 Resolved
EMERGENCY ESCAPE HATCH IN ENGINE CONTROL ROOM AND AFT STEERING Z DRIVE ROOM NEEDS TO BE TIGHTENED DOWN AND GASKETS REPALCED 46 CFR 174.210
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 May 2019
Resolved 26 April 2019
Resolution: [name withheld] RASMUSSEN ATTENDED
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 17 April 2019 Resolved
LIFE BOUY LINES ON BOTH BRIDGE BOUYS NEED TO BE REPLACED, NEW LINE ON BRIDGE BOUYS 46 CFR 133.70 AND 46 CFR 160.050-3
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 May 2019
Resolved 26 April 2019
Resolution: [name withheld] RASMUSSEN ATTENDED
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boat inventory
Issued 17 April 2019 Resolved
NON-OPERABLE COMPASS ON RESCUE BOAT, PROVIDE WORKING COMPASS ON RESCUE BOAT 46 CFR 133.175
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 May 2019
Resolved 26 April 2019
Resolution: [name withheld] RASMUSSEN ATTENDED
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 17 April 2019 Resolved
FUEL LINES ON RESCUE BOAT NEEDS TO BE REPLACED 46 CFR 199.45
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 May 2019
Resolved 26 April 2019
Resolution: [name withheld] RASMUSSEN ATTENDED
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 17 April 2019 Resolved
REPLACE FUEL LINES ON EMERGENCY GENERATOR 46 CFR 56.60-25
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 May 2019
Resolved 26 April 2019
Resolution: [name withheld] RASMUSSEN ATTENDED
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 30 July 2018 Resolved
Ground present on 24V Panel #1. Identify ground and correct.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 30 July 2018
Resolved 31 July 2018
Resolution: Verified deficiency correction with ABS surveyor
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 30 July 2018 Resolved
Rescue boat retro worn. Replace to the satisfaction of attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 30 July 2018
Resolved 31 July 2018
Resolution: Verified deficiency correction with ABS surveyor
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 July 2018 Resolved
Pressure relief devices on boat air receivers did not operate properly. Replace and test to the satisfaction of USCG MI.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 30 July 2018
Resolved 31 July 2018
Resolution: Verified deficiency correction with ABS surveyor
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 30 July 2018 Resolved
Fire doors did not self close. 1) ECR, 2) Bridge at bottom of ladder, 3) 02 level electronics room.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 August 2018
Resolved 31 July 2018
Resolution: Verified deficiency correction with ABS surveyor
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 30 July 2018 Resolved
Watertight doors missing or improper gasket material. 1) Aft steering hatch, 2) E/R escape hatch.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 30 July 2018
Resolved 31 July 2018
Resolution: Verified deficiency correction with ABS surveyor
08 - Alarms › N/A - No Subsystem › Closing water-tight doors alarm
Issued 30 July 2018 Resolved
Watertight hatch for aft steering alarm inop.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 30 July 2018
Resolved 31 July 2018
Resolution: Verified deficiency correction with ABS surveyor
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 30 July 2018 Resolved
Multiple lights on ring buoys found w/ expired batteries. One was inop.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 30 July 2018
Resolved 30 July 2018
Resolution: Vessel corrected prior to completion of exam.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 30 July 2018 Resolved
ECR has wooden desk and wood on transformer. Fire hazards to be minimized.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 30 July 2018
Resolved 31 July 2018
Resolution: Verified deficiency correction with ABS surveyor
Electrical › Electrical Distribution System (emergency) › Distribution Panel Bus
Issued 13 March 2016 Resolved
The deluge electrical system caught fire and melting many of the components and surrounding electrical components.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 September 2016
Resolution: The equipment that ws ruined by the fire was replaced and all equipment tested sat.

Casualty record · 6

6 June 2014Routine · role: Involved in a Marine Casualty · activity 4881463
11 March 2016Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 5832618
10 July 2023Routine · role: Involved in a Marine Casualty · activity 7765843
6 June 2024Routine · role: Involved in a Marine Casualty · activity 7948494
18 August 2024Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 8023293
26 November 2024Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 8062672
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.