Records from 2007 to 2026. Most recent: inspection, 11 June 2026.
Everything above is free. The detail below — the inspection history, the deficiency record, the recorded names, the casualty record and the documentation record — is Professional, $39 a month. Sign in.
Documentation record
Registered dimensions (L × B × D)89.6 ft × 32.0 ft × 10.2 ft
Registered tonnagegross 96 / net 65
ITC dimensions (L × B × D)89.6 ft × 32.0 ft × 10.2 ft
ITC tonnagegross 245 / net 99
BuilderYANK MARINE INC. · TUCKAHOE, NJ, UNITED STATES · built 2000
Hull materialAluminum
PropulsionJet Drive
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portBLOCK ISLAND, RI
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 30 August 2025 · expires 30 September 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it96 - Regulatory (Subpart C or D), Gross Ton
245 - Convention (Subpart B), Gross Ton
65 - Regulatory (Subpart C or D), Net Ton
99 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page
22 inspections, each with its date, unit and type; 20 deficiencies with the resolution recorded against each; 1 other recorded name, with years; 3 casualty investigations, with date and classification; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same
counts, and they are free.
$39 a month or $299 a year, every vessel page, cancel any time.
Founding rate $19.99 a month for life, for the first 200 subscribers.
Plans
Sign in
Maury does not score, rate or grade vessels, at any price.
Inspection history · 22
11 June 2026
Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8401441
18 June 2025
Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8160219
23 May 2025
Drydock Exam · Internal Structural Exam · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8145262
30 August 2024
In-Service Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7992751
21 June 2024
Annual Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7927492
18 August 2023
In-Service Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7675324
18 May 2023
COI Inspection · Administrative Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7671058
14 April 2023
Examination of Repairs · Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7663976
19 August 2022
In-Service Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7500630
17 June 2022
Annual Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7465735
21 October 2021
Deficiency Check · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7336803
27 August 2021
In-Service Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7289517
1 July 2021
Annual Inspection · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7220680
4 June 2021
Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7208498
20 June 2019
MTSA Verification · DAPI Audit · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6704692
4 June 2019
Drydock Exam · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6714151
27 August 2018
Deficiency Check · Administrative Inspection
Physical examination · Navigation Center · Activity 6524198
4 June 2018
Deficiency Check · DAPI Audit · COI Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6422093
11 September 2017
Excursion Permit
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6264136
20 June 2017
DAPI Audit · Deficiency Check · MTSA Verification · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6154400
1 June 2017
Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6154386
23 June 2016
MTSA Verification · DAPI Audit · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5885734
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 11 June 2026
No resolution recorded
A mechanical, manually operated device to assist in launching a survival craft must be provided if:(1) The survival craft weighs more than 200 pounds; and(2) The survival craft requires lifting more than one vertical foot to be launched. The current orientation of the cradle for the stbd fwd IBA creates an excess vertical lift to launch. Provide a mechanical means to assist in lifting the IBA or reposition the cradle to facilitate launching by next drydock.
Action required: 705 - Other - as specified
Due 31 May 2027
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 21 June 2024
Resolved
At each initial and subsequent inspection for certification, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspection of its fire protection equipment, including inspection and testing of smoke and fire detecting systems (including sensors and alarms). After conducting testing, a continuous trouble alarm stating 'remote sync fault' was displayed on the fire control panel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 July 2024
Resolved 28 June 2024
Resolution: Trouble alarm cleared and system tested satisfactorily.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 21 June 2024
Resolved
Each vessel must be equipped with a PA system that is audible during normal operating conditions throughout the accomodation spaces and all other spaces normally manned by crew members. The 2 PA speakers located on the port side of the main deck were not operable.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 July 2024
Resolved 12 July 2024
Resolution: 2 new speakers placed on port side main deck
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 21 June 2024
Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. Renew the grabline on the 2 identified lifebuoys due to UV degradation.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 July 2024
Resolved 12 July 2024
Resolution: grablines renewed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 18 May 2023
Resolved
All microprocessor or computer based systems must meet the requirements of part 62 in subchapter F of this chapter. Obtain approved design verification test procedures.
Action required: 705 - Other - as specified
Due 24 July 2023
Resolved 25 August 2023
Resolution: MSC approved DVTPs
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 19 August 2022
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel. Side shell frame intermittent fillet welds fractured at the frame to shell plate connection, in way of the port side jet room exhaust penetration. Repair by next dry-dock.
Action required: 705 - Other - as specified
Due 30 June 2023
Resolved 17 April 2023
Resolution: See Activity Number 7663976
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 17 June 2022
Resolved
Penetrations and openings in a watertight bulkhead must have means to make them watertight. Port and stbd engine room to jet room bulkheads not watertight.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 17 June 2022
Resolution: Fittings tightened to secure wires and fire stop applied to both.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 17 June 2022
Resolved
Each window and means of attachment to the dech house must be capable of withstanding the maximum load from wave and wind conditions on authorized route of the vessel. Stbd bridge window became loose. 46 CFR 116.1020
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Resolved 17 June 2022
Resolution: Adhesive and sealant was applied to secure the window.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 July 2021
Resolved
Discharge ends of fuel tank vent pipes must be fitted with corrosion resistant wire of at least 30x30 mesh. The stbd fuel tank vent flame screen is deteriorated and in need of replacement. Replace flame screen to the satisfaction of the attending Coast Guard Marine Inspector (CGMI).
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 July 2021
Resolved 15 July 2021
Resolution: See Activity Number 7220680
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 1 July 2021
Resolved
Piping for vital systems must meet 56.60 in sub chapter F. Rubber hose inserted in bilge suction piping does not meet the requirement. Provide repair proposal and affect repairs to bilge piping to the satisfaction of the attending CGMI.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 July 2021
Resolved 26 July 2021
Resolution: See Activity Number 7220680
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 4 June 2021
Resolved
Provide pit gauge report for centerline box bridge aft, engine room / jet room bulkheads and wet deck iwo sewage piping or Crop and renew to the satisfaction of the Coast Guard Marine Inspector (CGMI). To be completed prior to the 2022 operating season.
Action required: 705 - Other - as specified
Due 30 March 2022
Resolved 22 December 2021
Resolution: See Activity Number 7336803
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 27 August 2018
Resolved
Vsl is broadcasting: No IMO # and NAME with Vsl type precursor (NAME must not include Vsl type precursors, e.g. F/V, M/V).
Condition: Invalid
Action required: 705 - Other - as specified
Due 27 September 2018
Resolved 24 September 2018
Engineering › Bilge Water Management System › Manifold
Issued 4 June 2018
Resolved
Prove proper operation of starboard jet room bilge suction.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 June 2018
Resolved 5 June 2018
Resolution: Proved proper operation of starboard jet room bilge suction.
Fire Fighting › Fixed Fire Detection System › Heat Detectors
Issued 4 June 2018
Resolved
Replace heat detector in port jet room.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 June 2018
Resolved 5 June 2018
Resolution: Replaced heat detector in port jet room.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 4 June 2018
Resolved
Label ring buoys.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2018
Resolved 5 June 2018
Resolution: Labeled ring buoys.
Engineering › Bilge Water Management System › Strainer
Issued 4 June 2018
Resolved
Replace strainers on all bilge suctions that do not have a bottom to the strainer.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2018
Resolved 5 June 2018
Resolution: Replaced strainers on all bilge suctions that do not have a bottom to the strainer.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 4 June 2018
Resolved
Re-fasten trim molding on port storage closet on 02 deck.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2018
Resolved 5 June 2018
Resolution: Re-fastened trim molding on port storage closet on 02 deck.
Documentation › Markings/Placards › Capacity Marking
Issued 20 June 2017
Resolved
Relabel max passengers on upper most deck.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 July 2017
Resolved 28 July 2017
Electrical › Electric Supply System (service) › Battery Installation
Issued 20 June 2017
Resolved
Replace wing nuts with hex nuts.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 July 2017
Resolved 21 June 2017
Engineering › Fuel Oil Service System › Filter
Issued 20 June 2017
Resolved
Install proper plug in flame impingment shield on racor fuel filters.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 July 2017
Resolved 13 July 2017