MAURY USCG vessel records Sign in
← All vessels

VIRGINIA'S PRIDE

VIRGINIA'S PRIDE is a 2006 passenger vessel (inspected). The Coast Guard has recorded 58 inspections since 2005, most recently in January 2026, along with 153 deficiencies, 1 operational control, 1 with no removal date recorded and 5 casualty investigations between 2007 and 2025.

Records from 2005 to 2026. Most recent: inspection, 16 January 2026.

Built
2006
Last inspected
16 January 2026
Documentation
Expired · documentation file of 10 September 2026
Controls
1 with no removal date recorded

Identity

WDP3212
806470
Flag
UNITED STATES
367773250, 368343360
Maury page id
psix-806470

Inspections, by type

…with no type recorded9
Years with a record 18 calendar years (2005–2026)
The 58 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)129.9 ft × 43.0 ft × 10.0 ft
Registered tonnagegross 84 / net 57
ITC dimensions (L × B × D)129.9 ft × 43.0 ft × 10.0 ft
ITC tonnagegross 376 / net 113
BuilderCHIASSON WELDING SERVICE INC · LAROSE, LA, UNITED STATES · built 2006
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portST THOMAS, VI
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationExpired · issued 24 May 2006
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it84 - Regulatory (Subpart C or D), Gross Ton
376 - Convention (Subpart B), Gross Ton
57 - Regulatory (Subpart C or D), Net Ton
113 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDP3213MMSI 368343360 · active · compulsorily equipped · granted 28 November 2023, expires 28 November 2033
WDJ3981MMSI 367773250 · active · compulsorily equipped · granted 15 February 2017, expires 15 February 2027
WDD2153MMSI 367111590 · expired · compulsorily equipped · granted 4 May 2006, cancelled 9 July 2016
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

ISLANDER Passenger (Inspected) · MISLE 11964 · 7 September 2011 · activity 4138595ISLANDER Passenger (Inspected) · MISLE 11964 · 4 July 2011 · activity 4069044CAPT VIC Passenger (Inspected) · MISLE 43387 · 27 September 2007 · activity 3070998

Inspection history · 58

16 January 2026 Deficiency Check · Administrative Inspection · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 8297297
8 December 2025 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 8282300
6 December 2025 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 8281572
31 July 2025 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 8199661
1 May 2024 COI Inspection · Administrative Inspection · Deficiency Check · Examination of Repairs
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7906773
9 January 2024 Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7847302
17 November 2023 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7826567
22 October 2019 Administrative Inspection · Damage Survey · Drydock Exam · Examination of Repairs · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6839931
9 May 2018 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6409863
4 November 2017 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6300793
18 May 2017 Excursion Permit
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6149046
22 February 2017 DAPI Audit · COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6091599
17 June 2016 Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 5910204
16 December 2015 Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 5783869
29 October 2015 Annual Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 5753282
24 September 2015 Hull Examination · Internal Structural Exam · Examination of Repairs
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 5727858
6 October 2014 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 5001330
7 August 2014 Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 4947122
22 May 2014 In-Service Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 4864999
12 March 2014 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 4823485
27 July 2012 COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 4395085
24 July 2012 Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 4389379
4 July 2012 In-Service Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 4367991
24 February 2012 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 4398908
10 February 2012 In-Service Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 4242326
7 September 2011 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 4138595
14 July 2011 Underwater Inspection in lieu of Drydock
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 4082382
7 July 2011 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 4072345
4 July 2011 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 4069044
18 January 2011 Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3928076
20 December 2010 Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3926603
29 November 2010 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3900236
23 November 2010 COI Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3897065
21 November 2010 Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3895707
26 January 2010 Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3670230
27 July 2009 Annual Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3547479
9 July 2009 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3534402
26 January 2009 Internal Structural Exam · Administrative Inspection · Drydock Extension
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3400185
12 December 2008 Drydock Extension · Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3378630
16 October 2008 Administrative Inspection · Drydock Extension
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3367184
12 September 2008 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3322735
9 September 2008 Drydock Extension · Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3367178
14 July 2008 Administrative Inspection · Drydock Extension
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3367158
3 July 2008 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3255345
17 May 2008 Drydock Extension
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3222099
27 September 2007 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3070998
14 September 2007 Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3065139
11 September 2007 Annual Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3054844
6 March 2007 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3059867
5 March 2007 In-Service Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2882103
15 February 2007 Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2872401
5 February 2007 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2871327
17 January 2007 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2857763
25 August 2006 Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2761773
21 August 2006 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2755857
19 July 2006 Plan Review "T" Boat · Construction Oversight
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2718415
19 June 2006 Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2687182
8 November 2005 Welding Related Inspections Qualification Testing · Construction Oversight · Initial Certification · Internal Structural Exam · Hull Examination · Examination of Repairs · Inclining Experiment
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2656998

Deficiency record · 153

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 December 2025 Resolved
At each initial and subsequent inspection for certification the owner or managing operator shall be prepared to test the steering systems of the vessel and make them available for inspection to the extent necessary to determine that they are in suitable condition and fit for the service intended. Owner self reported loss of steering and took vessel out of service. Make necessary repairs and conduct steering test in the presence of a CG marine inspector prior to resuming commercial operations. Submit a CG-2692 within 5 days of the reportable marine casualty.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 January 2026
Resolved 7 January 2026
Resolution: Rectified to the satisfaction of the attending Marine Inspector.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 1 May 2024 Resolved
Sewage tank is leaking sewage through several cracks in the tank wall directly into the bilge. The tank wall appears to be corroded under the paint. An uncapped sewage pipe is also leaking sewage directly into the bilge. Submit repair proposal to USCG for review and plan approval prior to making permanent repairs. The repair proposal must include procedures for tank and bilge cleaning, welding materials used, tank plate thickness, piping/ valve materials and schedule, and drawings/sketches. 46 CFR 176.700
Action required: 705 - Other - as specified
Resolved 30 May 2024
Resolution: Cleared by CAMI [name withheld].
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 1 May 2024 Resolved
Starboard main engine transmission has significant fluid leak. Determine the cause of the transmission fluid leak, complete all necessary repairs, provide a report addressing the scope of work completed and provide any associated invoices/ receipts. Marine inspectors will reinspect after the documents are received. 46 CFR 176.804
Action required: 705 - Other - as specified
Resolved 13 June 2024
Resolution: TM was overfilled. Verified no indications of leaks.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 May 2024 Resolved
Signifigant hydraulic fluid leak noted in way of the hydraulic fluid tank near the filter/gauge in the port side aft engine room. Determine the cause of the hydraulic fluid leak, complete all necessary repairs, provide a report addressing the scope of work completed and provide any associated invoices/ receipts. Marine inspectors will reinspect after the documents are received.Determine the cause of the hydraulic fluid leak, complete all necessary repairs, provide a report addressing the scope of work completed and provide any associated invoices/ receipts. Marine inspectors will reinspect after the documents are received. 46 CFR 176.804
Action required: 705 - Other - as specified
Resolved 13 June 2024
Resolution: Steering pump pressure gauge was the source of the leak and replaced.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 1 May 2024 Resolved
Engine room watertight door has a seized dog. Service dog for reinspection. 46 CFR 176.802
Action required: 705 - Other - as specified
Resolved 13 June 2024
Resolution: Verified dogs serviced.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 1 May 2024 Resolved
Port side lazarette hatch is seized. Service all fittings for reinspection. 46 CFR 176.802
Action required: 705 - Other - as specified
Resolved 13 June 2024
Resolution: Verfified proper servicing.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 1 May 2024 Resolved
Starboard side steering linkage fitting missing cotter pin. Replace cotter pin for reinspection. 46 CFR 176.814
Action required: 705 - Other - as specified
Resolved 13 June 2024
Resolution: Verified cotter pins replaced.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 1 May 2024 Resolved
Through-watertight bulkhead penetration at the lazarette is not watertight. Provide sealant to make the penetration watertight. 46 CFR 179.320
Action required: 705 - Other - as specified
Resolved 10 July 2024
Resolution: Verified approved sealant applied to bulkhead penetration.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 1 May 2024 Resolved
Provide servicing report from the last fixed firefighting system service from 2023. 46 CFR 176.810
Action required: 705 - Other - as specified
Resolved 13 June 2024
Resolution: Verified FF servicing report dated 29May2024 by Liferafts PR.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 May 2024 Resolved
All bilge piping suction pickups do not have strainers. Provide suitable strainers having an open area not less than three times the area of the bilge pipe. 46 CFR 182.25-5
Action required: 705 - Other - as specified
Resolved 13 June 2024
Resolution: Verified brass strainers installed and satisfactorilu tested bilge suction.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 1 May 2024 Resolved
Starboard generator starting battery is connected to a portable battery charger. Remove portable charger, replace battery in-kind and start the gnerator for reinspection by USCG MI's.
Action required: 705 - Other - as specified
Resolved 13 June 2024
Resolution: Batteries were replaced in-kind and portable charger removed.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 1 May 2024 Resolved
Replace gaskets for main deck void hatches for reinspection by USCG MI's. 46 CFR 176.802
Action required: 705 - Other - as specified
Resolved 13 June 2024
Resolution: Verified new gaskets installed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 1 May 2024 Resolved
Vessel missing required number of portable fire extinguishers.Provide the following portable fire extinguihers for reinspection by USCG MI's in accordance with COI: (01) 10-B:C at the operating station (01) 40-B:C outside the engine room (04) 40-B on the vehicle deck (01) 40-B:C in the galley (01) 2-A in the accomodation space 46 CFR 176.810
Action required: 705 - Other - as specified
Resolved 13 June 2024
Resolution: Verified all required extinguishers on board.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 1 May 2024 Resolved
Missing 02 spanner wrenches. Provide spanner wrenches at each fire station on board the vessel for USCG MI reinspection. 46 CFR 176.810
Action required: 705 - Other - as specified
Resolved 13 June 2024
Resolution: Spanner wrenches verified.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 May 2024 Resolved
Owner and vessel crew were unfamiliar with which hatches led to which void spaces during bilge suction testing. Label each hatch on the vehicle deck. 46 CFR 176.800
Action required: 705 - Other - as specified
Resolved 13 June 2024
Resolution: Hatches labeled adjacently on bulwarks.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 1 May 2024 Resolved
Owner could not safely fully close vehicle ramp. Demonstrate full vehicle ramp closure and locking ability for USCG reinspection. 46 CFR 176.802
Action required: 705 - Other - as specified
Resolved 13 June 2024
Resolution: Verified vehicle ramp fully closed satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 May 2024 Resolved
Ventilation closures on main deck could not be manipulated. Lubricate/service all ventilation closures and tracks to demonstrate proper closure for USCG reinspection. 46 CFR 176.804
Action required: 705 - Other - as specified
Resolved 13 June 2024
Resolution: Observed satisfactory closure of all ventilation.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 1 May 2024 Resolved
Post stability letter under glass or other suitable transparent material, such that all pages are visible at the operating station. 46 CFR 176.306
Action required: 705 - Other - as specified
Resolved 13 June 2024
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 1 May 2024 Resolved
Post COI under glass or other suitable transparent material, such that all pages are visible in a conspicuous place where observation by passengers is likely. 46 CFR 176.302
Action required: 705 - Other - as specified
Resolved 13 June 2024
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 May 2024 Resolved
Paint lines to indicate the vehicle runways and the aisle spaces on the vehicle deck. Paint “NO SMOKING” sign to take all necessary precautions to prevent smoking. 46 CFR 185.340
Action required: 705 - Other - as specified
Resolved 13 June 2024
Resolution: Verified lines painted on vehicle deck.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 May 2024 Resolved
On a vessel authorized to carry one or more vehicles, suitable chains, cables, or other barriers must be installed at the end of each vehicle runway. In addition, temporary rails or equivalent protection must be installed in way of each vehicle ramp, in compliance with § 177.900, when the vessel is underway. 46 CFR 177.940
Action required: 705 - Other - as specified
Resolved 13 June 2024
Resolution: Verified.
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage
Issued 1 May 2024 Resolved
The master or person in charge of a ship to which this section applies shall ensure that the ship is not operated unless a garbage management plan meeting paragraph (b) of this section is on the ship and that each person handling garbage follows the plan. Each garbage management plan under paragraph (a) of this section must be in writing and— Provide for the discharge of garbage by means that meet Annex V of MARPOL, the Act, and §§ 151.51 through 151.77; Describe procedures for minimizing, collecting, processing, storing, and discharging garbage; and Designate the person who is in charge of carrying out the plan. 46 CFR 184.702 33 CFR 151.57
Action required: 705 - Other - as specified
Resolved 13 June 2024
Resolution: Verified garbage management plan.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 May 2024 Resolved
Label all life jacket stowage locations with the number of life jackets. 46 CFR 185.604
Action required: 705 - Other - as specified
Resolved 13 June 2024
Resolution: Verified stowage locations marked.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 May 2024 Resolved
On a vessel on which the number of passengers permitted on upper decks is limited by stability criteria, as indicated by the vessel's stability letter, the maximum number of passengers allowed on an upper deck must be indicated by a durable marking of at least 25 millimeters (1 inch) numbers and letters at the entranceway to that deck. 46 CFR 185.602
Action required: 705 - Other - as specified
Resolved 13 June 2024
Resolution: Verified marking.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 May 2024 Resolved
Provide current drug consortium covered employees list to cover all crewmembers. 46 CFR 16.230
Action required: 705 - Other - as specified
Resolved 13 June 2024
Resolution: Verified.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 May 2024 Resolved
Provide drug consortium pre-employment testing for all enrolled crewmembers. 46 CFR 16.210
Action required: 705 - Other - as specified
Resolved 13 June 2024
Resolution: Verified
Communications › Radio Communications › EPIRB
Issued 28 February 2017 Resolved
Provide EPIRB registration showing revised MMSI and Call Sign of vessel.
Action required: 705 - Other - as specified
Due 28 March 2017
Resolved 6 March 2017
Resolution: Revised registration provided.
Engineering › Diesel Engine (propulsion-reduction gear) › Cylinder Head
Issued 22 February 2017 Resolved
Prove proper operation of STBD MDE.
Action required: 705 - Other - as specified
Due 8 March 2017
Resolved 28 February 2017
Resolution: Vessel replaced head gasket and proved proper operation.
Fire Fighting › Fire Pumps › Arrangement
Issued 22 February 2017 Resolved
Prove proper operation of fire pump/main.
Action required: 705 - Other - as specified
Due 8 March 2017
Resolved 28 February 2017
Resolution: Vessel showed proper operation.
Communications › Alarms/Indicators › Bilge Alarm
Issued 22 February 2017 Resolved
Prove proper of lazarette high water alarm.
Action required: 705 - Other - as specified
Due 8 March 2017
Resolved 28 February 2017
Resolution: Vessel demonstrated proper operation.
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 22 February 2017 Resolved
Provide exhaust lagging port on MDE.
Action required: 705 - Other - as specified
Due 8 March 2017
Resolved 28 February 2017
Resolution: Exhaust lagging replaced.
Electrical › Electric Generation Source (service) › Power Requirement
Issued 22 February 2017 Resolved
Prove proper operation of STBD generator.
Action required: 705 - Other - as specified
Due 3 April 2017
Resolved 28 February 2017
Electrical › Electrical Distribution System (service) › Junction Box
Issued 22 February 2017 Resolved
Properly secure electrical junction box in way of stbd fwd compartment near ramp.
Action required: 705 - Other - as specified
Due 8 March 2017
Resolved 28 February 2017
Resolution: Removed junction box.
Electrical › Electrical Distribution System (service) › Wiring
Issued 22 February 2017 Resolved
Correct chaffing wire for ramp lighting in way of stbd fwd compartment near ramp.
Action required: 705 - Other - as specified
Due 8 March 2017
Resolved 28 February 2017
Resolution: Vessel added chaffing protection.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 22 February 2017 Resolved
Prove proper operation of emergency lighting in passenger lounge.
Action required: 705 - Other - as specified
Due 8 March 2017
Resolved 28 February 2017
Resolution: Operation verified.
Fire Fighting › Fire Pumps › Power Source
Issued 22 February 2017 Resolved
Label remote fire pump switch at operating station.
Action required: 705 - Other - as specified
Due 8 March 2017
Resolved 28 February 2017
Resolution: Switch labeled.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 22 February 2017 Resolved
Properly stow life-jackets and label stowage location appropriate placarding.
Action required: 705 - Other - as specified
Due 8 March 2017
Resolved 28 February 2017
Resolution: PFDs stowed and labelled.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 22 February 2017 Resolved
Provide current tide tables.
Action required: 705 - Other - as specified
Due 8 March 2017
Resolved 28 February 2017
Resolution: Provided.
Deck/Cargo › Cargo Stowage › General
Issued 22 February 2017 Resolved
Provide lane lines on vehicle deck.
Action required: 705 - Other - as specified
Due 8 March 2017
Resolved 28 February 2017
Resolution: Lane lines marked.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 22 February 2017 Resolved
Provide current first aid kit.
Action required: 705 - Other - as specified
Due 8 March 2017
Resolved 28 February 2017
Resolution: First aid kit provided.
Electrical › Lighting (service) › Lighting Fixture
Issued 22 February 2017 Resolved
Provide lighting covers for light fixtures in bridge and passenger lounge.
Action required: 705 - Other - as specified
Due 8 March 2017
Resolved 28 February 2017
Resolution: Lighting covers provided and installed.
Electrical › Lighting (service) › Lighting Fixture
Issued 22 February 2017 Resolved
Repair or replace light fixtures in port side accommodation space.
Action required: 705 - Other - as specified
Due 8 March 2017
Resolved 28 February 2017
Resolution: Lighting fixture replaced.
Electrical › Electrical Distribution System (service) › Wiring
Issued 22 February 2017 Resolved
Remove microwave from port side accomm space or properly replace power cable.
Action required: 705 - Other - as specified
Due 8 March 2017
Resolved 28 February 2017
Resolution: Microwave removed.
Electrical › Lighting (service) › Lighting Fixture
Issued 22 February 2017 Resolved
Repair or replace aft upper deck deck lighting fixture aft house bulkhead.
Action required: 705 - Other - as specified
Due 8 March 2017
Resolved 28 February 2017
Resolution: Globe provided.
Fire Fighting › Firemans Outfit › Axe
Issued 22 February 2017 Resolved
Stencil vessel name on fire axe.
Action required: 705 - Other - as specified
Due 8 March 2017
Resolved 28 February 2017
Resolution: Name stenciled.
Communications › Alarms/Indicators › Fire Alarm
Issued 22 February 2017 Resolved
Prove proper operation of machinery space fire detection or provide third party report of testing. (smoke/ fire detectors). Until corrected, vessel to man engine room while under way.
Action required: 705 - Other - as specified
Due 3 April 2017
Resolved 10 May 2017
Resolution: Fire detection and alarm system tested satisfactorily.
Operations/Management › Drills/Instruction › Fire
Issued 22 February 2017 Resolved
Conduct MOB and fire drill with attending CG Marine Inspector.
Action required: 705 - Other - as specified
Due 8 March 2017
Resolved 28 February 2017
Resolution: Witnessed satisfactory fire and underway man overboard drills.
Documentation › Logs/Records › Logbook (official)
Issued 17 June 2016 Resolved
Vessel restriced from carriage of passengers until completion of an in-service exam by CG marine inspector due to vessel being in a layed up status after being seized by U.S. Marshalls.
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 September 2016
Resolved 22 February 2017
Resolution: Vessel completed COI inspection.
Fire Fighting › Fire Pumps › Pressure
Issued 29 October 2015 Resolved
Provide pressure gauge for fire pumps.
Action required: 705 - Other - as specified
Due 15 November 2015
Resolved 16 December 2015
Resolution: Pressure gauge installed on fire pump piping.
Construction/Loadline › Penetrations › Flange Pad
Issued 29 October 2015 Resolved
Properly secure both fwd bulkhead engine room access hatches.
Action required: 705 - Other - as specified
Due 15 November 2015
Resolved 16 December 2015
Resolution: Hatches properly secured.
Engineering › Diesel Engine (auxiliary) › Valve Actuating Gear
Issued 29 October 2015 Resolved
Replace Hydarulic line on return side of hydraulic pump, fwd center main engine.
Action required: 705 - Other - as specified
Due 15 November 2015
Resolved 16 December 2015
Resolution: Hydraulic line replaced.
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 29 October 2015 Resolved
Replace missing center engine exhaust lagging iwo turbo charger.
Action required: 705 - Other - as specified
Due 15 November 2015
Resolved 16 December 2015
Resolution: Lagging replaced.
Engineering › Diesel Engine (propulsion-reduction gear) › Block
Issued 29 October 2015 Resolved
Make permanent repairs to oil leak on fwd section of center main diesel engine.
Action required: 705 - Other - as specified
Due 15 January 2016
Resolved 22 February 2017
Resolution: Oil leaks repaired.
Electrical › Electric Supply System (service) › Cable
Issued 29 October 2015 Resolved
Make permanent repairs to center engine start battery lug.
Action required: 705 - Other - as specified
Due 15 November 2015
Resolved 16 December 2015
Resolution: Battery lug replaced.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 29 October 2015 Resolved
Replace missing switch knob on CO2 control panel in wheel house.
Action required: 705 - Other - as specified
Due 15 November 2015
Resolved 16 December 2015
Resolution: Knob replaced.
Electrical › Lighting (service) › Lighting Fixture
Issued 29 October 2015 Resolved
Provide light covers for all deck overhead ligthing fixtures.
Action required: 705 - Other - as specified
Due 15 November 2015
Resolved 17 December 2015
Resolution: Light bulbs removed as a temp repair until light covers can be acquired.
Electrical › Lighting (service) › Lighting Fixture
Issued 29 October 2015 Resolved
Replace light covers on overhead lighting in passenger lounge.
Action required: 705 - Other - as specified
Due 15 November 2015
Resolved 16 December 2015
Resolution: Light bulbs removed until covers can be acquired.
Engineering › Freshwater System (cylinder head cooling) › Piping
Issued 29 October 2015 Resolved
Replace water coolant piping on port side generator.
Action required: 705 - Other - as specified
Due 15 November 2015
Resolved 16 December 2015
Resolution: Piping properly repaired.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 29 October 2015 Resolved
Provide exhaust lagging on both aux generators iwo turbo.
Action required: 705 - Other - as specified
Due 15 November 2015
Resolved 16 December 2015
Resolution: Lagging properly installed.
Construction/Loadline › Structures › Deck Plating
Issued 24 September 2015 Resolved
Provide a repair proposal and make permanent repairs to cargo ramp.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 October 2015
Resolved 15 October 2015
Resolution: Repair proposal discussed. All marked metals to be cropped and renewed.
Operations/Management › Pollution › Retention of Oily Mixture
Issued 24 September 2015 Resolved
Remove all excessive oily water from lazarette.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 October 2015
Resolved 9 October 2015
Resolution: Oily water pumped to tank and disposed of.
Operations/Management › Pollution › Retention of Oily Mixture
Issued 24 September 2015 Resolved
Remove excessive oily water and waste oil from bilge of engine room.
Action required: 705 - Other - as specified
Due 15 October 2015
Resolved 9 October 2015
Resolution: Oily water pumped from bilge to tank and properly disposed of.
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 24 September 2015 Resolved
Repaint draft marks in contrasting color.
Action required: 705 - Other - as specified
Due 15 October 2015
Resolved 9 October 2015
Resolution: Draft marks painted on hull.
Engineering › Bilge Water Management System › Strainer
Issued 24 September 2015 Resolved
Replace all wasted bilge strainers.
Action required: 705 - Other - as specified
Due 15 October 2015
Resolved 16 December 2015
Resolution: Bilge strainers replaced.
Construction/Loadline › Structures › Machinery Space Opening
Issued 24 September 2015 Resolved
Replace engine room emergency exit hatch gasket.
Action required: 705 - Other - as specified
Due 15 October 2015
Resolved 15 October 2015
Resolution: Engine room emergency exit hatch gasket replaced with new gasket material.
Deck/Cargo › Ballast › Valves
Issued 24 September 2015 Resolved
Replace missing sounding tube plug on #2 starboard ballast tank.
Action required: 705 - Other - as specified
Due 15 October 2015
Resolved 16 December 2015
Resolution: Ballast tank sounding tubes properly capped.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 24 September 2015 Resolved
Replace broken keyway on starboard propeller shaft.
Action required: 705 - Other - as specified
Due 15 October 2015
Resolved 15 October 2015
Resolution: Propeller shaft key replaced and prop reinstalled on shaft.
Deck/Cargo › Cargo Stowage › General
Issued 24 September 2015 Resolved
Paint lane lines on vehicle deck.
Action required: 705 - Other - as specified
Due 15 November 2015
Resolved 16 December 2015
Resolution: Lines painted on vehicle deck.
Accommodation/Occupational Safety › Occupational Safety › Smoking
Issued 24 September 2015 Resolved
Post no smokine placards on vehicle deck.
Action required: 705 - Other - as specified
Due 15 October 2015
Resolved 16 December 2015
Resolution: "No Smoking" painted.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 6 October 2014 Resolved
Properly mount both BII fire extinguishers in upper passenger lounge.
Action required: 705 - Other - as specified
Due 20 October 2014
Resolved 22 October 2014
Resolution: Extinguishers mounted.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 6 October 2014 Resolved
Provide recommended emergency instructions placard.
Action required: 705 - Other - as specified
Due 20 October 2014
Resolved 22 October 2014
Resolution: Instructions posted.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 6 October 2014 Resolved
Repair rail course on upper deck forward railing.
Action required: 705 - Other - as specified
Due 20 October 2014
Resolved 22 October 2014
Resolution: Rail course repaired.
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 6 October 2014 Resolved
Replace missing bolts on center engine exhaust manifold.
Action required: 705 - Other - as specified
Due 20 October 2014
Resolved 22 October 2014
Resolution: Bolts replaced.
Documentation › Markings/Placards › Oil Discharge Placard
Issued 6 October 2014 Resolved
Provide oil pollution placard.
Action required: 705 - Other - as specified
Due 20 October 2014
Resolved 22 October 2014
Resolution: Placard provided.
Electrical › Lighting (service) › Lighting Fixture
Issued 6 October 2014 Resolved
Repair or remove center head overhead lighting and associated wiring.
Action required: 705 - Other - as specified
Due 20 October 2014
Resolved 22 October 2014
Resolution: Fixture was replaced.
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 22 May 2014 Resolved
ALL VEHICLES NEXT TO THE LOADING RAMP MUST HAVE ITS WHEELS SECURELY BLOCKED, WHILE THE VESSEL IS BEING NAVIGATED AS PER 46 CFR 185.340.
Action required: 705 - Other - as specified
Due 23 May 2014
Resolved 7 August 2014
Resolution: Vessel had wheel chocks for all front row vehicles.
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 22 May 2014 Resolved
INSTALL AND MAINTAIN PAINTED LINES ON VEHICLE DECK TO INDICATE THE VEHICLE RUNWAYS AND THE AISLE SPACES AS PER 46 CFR 185.340.
Action required: 705 - Other - as specified
Due 30 May 2014
Resolved 7 August 2014
Resolution: Lane lines painted on vessel cargo deck.
Fire Fighting › Fire Hydrants › Condition
Issued 22 May 2014 Resolved
MAKE PERMANENT REPAIRS TO MISSING HANDLE FOR FORWARD, PORT FIRE STATION SUPPLY VALVE HANDLE.
Action required: 705 - Other - as specified
Due 23 May 2014
Resolved 30 June 2014
Navigation › Piloting/Steering › Coast Guard Light List
Issued 27 July 2012 Resolved
Vessel had outdated copies of Coast Guard Light List, Coast Pilot and tides/currents tables. Provide current copies of publications.
Condition: Invalid
Action required: 705 - Other - as specified
Due 27 August 2012
Resolved 25 July 2013
Communications › Audible Communications › Bell
Issued 27 July 2012 Resolved
Bell is missing the clacker. Provide bell of a proper size and prove proper operation.
Condition: Improper/Lack of Maintenance
Due 27 August 2012
Resolved 30 July 2012
Resolution: Obsvd proper operation of bell.
Communications › Internal Communications System › Portable Radios
Issued 27 July 2012 Resolved
Vessel crew could not prove operation of installed two way communications between operating station and machinery space. Repair and prove operation of fixed two way communications at operating station and machinery space.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 July 2012
Resolution: Vsl provided two handheld radios and proved operation.
Communications › Public Address System › Loudspeaker
Issued 27 July 2012 Resolved
Vessel could not prove operation of the public address system. Repair and prove operation of public address system.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 August 2012
Resolved 25 July 2013
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 27 July 2012 Resolved
Vessel missing posted emergency instructions. Print and post emergency instructions.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 August 2012
Resolved 25 July 2013
Communications › Radio Communications › EPIRB
Issued 27 July 2012 Resolved
Hydrostatic release on EPIRB was not properly marked with expiration date upon installation. Replace hydrostatic release and properly mark with expiration date.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 July 2012
Resolution: Obsvd installation of new hydrostatic release.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 27 July 2012 Resolved
Vessel missing second portable light in the operating station. Provide two portable lights, one at operating station and one in the machinery space.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 August 2012
Resolved 30 July 2012
Resolution: Obsvd two portable lights.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 27 July 2012 Resolved
Life preservers are stored only in the top deck passenger lounge in an inconvenient manner for proper distribution in time of emergency. Make life preservers available THROUGHOUT the accommodation spaces and properly mark number and type in all spaces where stowed.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 July 2012
Resolution: Obsvd two new wooden boxes on lower deck with adult lifejackets stowed properly and marked properly.
Lifesaving › Buoyant Apparatus › Serviceable
Issued 27 July 2012 Resolved
Vessel had 7 buoyant apparatuses but only needs 4. All buoyant apparatuses were worn from the sun with visible cracks and punctures. The vessel name and capacity of each BA was dulled from the sun. Properly service all buoyant apparatuses to include: repair cracks and paint orange; properly makr with name and port; properly mark with capacity; ensure all lines are serviceable.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 July 2012
Resolution: Wrote new deficiency.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 27 July 2012 Resolved
Line on two lifebuoys was significantly dry rotted and the ringbuoy on the upper deck was missing the stopper thereby allowing water to seep inside. Replace line on 2 lifebuoys and make easily accessible. Ensure no penetrations, crack or holes are in ring lifebuoys.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 July 2012
Resolution: Saw silicone in the opening of the ring lifebuoy. Obsvd new lines.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 27 July 2012 Resolved
Aspirin was expired. Provide unexpired aspirin for First Aid Kit.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 August 2012
Resolved 25 July 2013
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 27 July 2012 Resolved
Man Overboard was flawed from lack of communications, to failure to throw lifebuoy or PFD, to chaos on the bridge, to failure to keep eye on the MOB. Prove satisfactory Man Overboard Drill.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 July 2012
Resolution: Obsvd satisfactory drill.
Fire Fighting › Fire Hydrants › Material
Issued 27 July 2012 Resolved
Spanner wrench was broken. Provide spanner wrench on stbd side fire station upper deck.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 August 2012
Resolved 25 July 2013
Lifesaving › Lifefloat › Serviceable
Issued 27 July 2012 Resolved
Vsl lifefloats are worn from sun damage to include excessive cracking, punctures and faded vsl name, port and capacity. Repair lifefloats. Vsl is not to go outside 3 NM from shore in domestic waters only until life floats are repaired.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 August 2012
Resolved 25 July 2013
Documentation › Certificates/Documents › FCC Vessel Bridge-to-Bridge Radiotelephony Cert.
Issued 7 July 2011 Resolved
Provide new FCC Vessel Bridge to Bridge Certificate no later than 05 August 2011.
Action required: 705 - Other - as specified
Due 5 August 2011
Resolved 7 October 2011
Documentation › Certificates/Documents › FCC SSL
Issued 7 July 2011 Resolved
Provide new FCC Safety Radiotelephony Certificate no later than 05 August 2011.
Action required: 705 - Other - as specified
Due 5 August 2011
Resolved 7 October 2011
Electrical › Lighting (service) › Lighting Fixture
Issued 7 July 2011 Resolved
Prior to carrying passengers, make permanent repairs to main deck overhead lighting fixtures.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 July 2011
Resolved 7 October 2011
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 7 July 2011 Resolved
Prior to carrying passengers, provide and install plug and plug retaining device for port and stbd aftermost fuel oil fill/vent containment.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 July 2011
Resolved 7 October 2011
Communications › Radio Communications › EPIRB
Issued 7 July 2011 Resolved
Service EPIRB no later than 01 September 2011.
Action required: 705 - Other - as specified
Due 1 September 2011
Resolved 7 October 2011
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 7 July 2011 Resolved
Prior to carrying passengers, make permanent repairs to leaking tank access cover for #2 stbd fuel oil storage tank.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 July 2011
Resolved 7 October 2011
Construction/Loadline › Hull › Weld
Issued 7 July 2011 Resolved
Prior to carrying passengers, make permanent repairs by welding underside of main deck insert in Bay #2 from engine room, port and stbd..
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 July 2011
Resolved 7 October 2011
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 7 July 2011 Resolved
Prior to carrying passengers, perform five (5) year hydrostatic testing of both portable CO2 fire extinguishers located in the engine room or replace in kind.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 July 2011
Resolved 7 October 2011
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 7 July 2011 Resolved
Prior to carrying passengers, make permanent repairs to upper deck hand rail weld at ladder from main deck.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 July 2011
Resolved 7 October 2011
Electrical › Lighting (service) › Lighting Fixture
Issued 7 July 2011 Resolved
Prior to carrying passengers, provide and install marine enclosed-type lighting fixture for both restrooms located on port side of main deck.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 July 2011
Resolved 7 October 2011
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 18 January 2011 Resolved
Provide and install suitable chains, cables, or other barriers across vehicle ramp as per 46 CFR 177.940.
Action required: 705 - Other - as specified
Due 31 January 2011
Resolved 11 May 2011
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 18 January 2011 Resolved
Develop, implement and enforce a written Company Policy/Directive/Instruction in regards to lowering the vessels vehicle ramp. Specifically, when the ramp shall and shall not be lowered during vessel operation. Document shall have signature page for all employees involved in ramp operations.
Action required: 705 - Other - as specified
Due 31 January 2011
Resolved 11 May 2011
Documentation › Certificates/Documents › FCC Vessel Bridge-to-Bridge Radiotelephony Cert.
Issued 23 November 2010 Resolved
post original radiotelephony certificate.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 20 December 2010
Resolved 20 December 2010
Resolution: Radio Telephony Certificate posted
Navigation › Piloting/Steering › Marine Charts
Issued 23 November 2010 Resolved
Provide updated charts.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 December 2010
Resolved 20 December 2010
Resolution: Current Charts were found on board
Communications › Radio Communications › VHF Radiotelephone
Issued 23 November 2010 Resolved
Demonstrate the operation of MF radio.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 20 December 2010
Resolved 20 December 2010
Resolution: satisfactory MF radio operation was demonstrated
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 23 November 2010 Resolved
Prove red white red operational navigational lights.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 December 2010
Resolved 20 December 2010
Resolution: Red White Red Navigation Lights were operating while on board
Deck/Cargo › Vapor Control Systems › Flame Screens
Issued 23 November 2010 Resolved
Replace vent screens
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 December 2010
Resolved 20 December 2010
Resolution: Flame Screens on Fuel oil tanks were satisfactorily replaced
Engineering › Freshwater System (intermediary cooling) › Piping
Issued 23 November 2010 Resolved
repair port generator cooling pipe.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 December 2010
Resolved 20 December 2010
Resolution: Port Generator cooling piping was satisfactorily repaired
Engineering › Fuel Oil Service System › Valve, Control
Issued 23 November 2010 Resolved
Secure throttle cables.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 20 December 2010
Resolved 20 December 2010
Resolution: Throttle cable attachments to Maine Engine Controls were secured with double locking nuts
Engineering › Bilge Water Management System › Piping
Issued 23 November 2010 Resolved
Double clamp all vital systems hose to pipe connections.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 20 December 2010
Resolved 13 December 2010
Resolution: Bilge hose piping found with double clamps throughout.
Lifesaving › Lifefloat › Painter
Issued 23 November 2010 Resolved
tac weld sea painter.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 December 2010
Resolved 20 December 2010
Resolution: Sea Painter found appropriately attached
Documentation › Certificates/Documents › Certificate of Inspection
Issued 23 November 2010 Resolved
COI expired on September 15, 2010. Vessel COI was taken off vessel on November 21, 2010 by MSD St Thomas.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 November 2010
Resolved 23 November 2010
Resolution: Issued COI to vessel.
Construction/Loadline › Structures › Door
Issued 27 July 2009 Resolved
Make permanent repairs to fractured welds and framing for vehicle ramp, port and stbd, as shown.
Action required: 705 - Other - as specified
Due 27 July 2009
Resolved 9 December 2009
Resolution: Cleared, Temp repairs attempted. Re-issued requirement with two week deadline.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 27 July 2009 Resolved
Provide and install electrical outlet blank plate cover for open electrical junction box located in engine room, stbd side, as shown.
Action required: 705 - Other - as specified
Due 31 July 2009
Resolved 9 December 2009
Fire Fighting › Remote Fuel Shutoff › General
Issued 27 July 2009 Resolved
Prior to carrying passengers, mark Emergency Fuel Oil Shutoff Station as per 46 CFR 185.608.
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 July 2009
Resolved 9 December 2009
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 27 July 2009 Resolved
Provide and install f/o filling station/vent containment plug, #2, starboard side.
Action required: 705 - Other - as specified
Due 31 July 2009
Resolved 22 September 2009
Fire Fighting › Fixed CO2 Fire Extinguishing System › Remote Pulls
Issued 27 July 2009 Resolved
Prior to carrying passengers, provide and mount hammering device in vicinity of CO2 Break Glass Boxes behind wheelhouse ladder, as shown.
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 July 2009
Resolved 22 September 2009
Construction/Loadline › Hull › Hull Plating
Issued 26 January 2009 Resolved
PROVIDE ALL DETAILS, IN WRITING, CONCERNING THE APPLICATION OF CEMENT PATCH ON VESSELS STARBOARD BOW, ABOVE THE WATERLINE.
Action required: 705 - Other - as specified
Due 27 February 2009
Resolved 10 July 2009
Resolution: Area cropped out for renewal
Construction/Loadline › Hull › Hull Plating
Issued 26 January 2009 Resolved
MAKE PERMANENT REPAIRS TO STARBOARD BOW IN WAY OF TEMPORARY CEMENT PATCH NO LATER THAN NEXT DRY DOCKING AVAILABILITY.
Action required: 705 - Other - as specified
Due 15 June 2009
Resolved 17 July 2009
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 12 September 2008 Resolved
Vessel's rail courses are spaced at intervals of more than 4 inches. Rail courses must be reduced a size of not more than 4 inches in accordance with Title 46 CFR 177.900(g)(1)(iii).
Action required: 705 - Other - as specified
Due 12 November 2008
Resolved 18 September 2008
Fire Fighting › Means of Escape › Doorways
Issued 12 September 2008 Resolved
Vessel's emergency exit from emergency room was not properly mark. Issued (1) requirement to properly mark emergency escape exit.
Action required: 705 - Other - as specified
Due 12 October 2008
Resolved 18 September 2008
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 12 September 2008 Resolved
Vessel's lazarette hatch cover was not attached to the hatch frame or coaming by hinges, captive chains or other devices. Attached the hatch cover to the hatch frame or coaming by hinges, captive chains or to other devices to prevent its loss.
Action required: 705 - Other - as specified
Due 12 October 2008
Resolved 18 September 2008
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 12 September 2008 Resolved
Several bolts were missing from each hatch cover located on the car deck. Missing must be replaced.
Action required: 705 - Other - as specified
Due 12 October 2008
Resolved 18 September 2008
Lifesaving › Lifefloat › Serviceable
Issued 12 September 2008 Resolved
Three of the vessel's 12 liferafts are not serviceable. Repair, replace and/or remove all non-serviceable liferafts.
Action required: 705 - Other - as specified
Due 12 October 2008
Resolved 18 September 2008
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 12 September 2008 Resolved
Restencil each lifejacket stowage compartment.
Action required: 705 - Other - as specified
Due 12 October 2008
Resolved 18 September 2008
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 12 September 2008 Resolved
Ensure that each child lifejacket has been marked with the vessel's name.
Action required: 705 - Other - as specified
Due 12 October 2008
Resolved 18 September 2008
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 12 September 2008 Resolved
Ensure that each ring lifebuoy is marked with the vessel's name.
Action required: 705 - Other - as specified
Due 12 October 2008
Resolved 18 September 2008
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 12 September 2008 Resolved
Ensure that a waterlight with 3-ft lanyard and a corrosion-resistant clip is attached to at least one of the vessel's ring lifebuoy.
Action required: 705 - Other - as specified
Due 12 October 2008
Resolved 18 September 2008
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 12 September 2008 Resolved
Posted lifejacket donning placards.
Action required: 705 - Other - as specified
Due 12 October 2008
Resolved 18 September 2008
Lifesaving › Lifefloat › Paddle
Issued 12 September 2008 Resolved
Ensure that each lifefloat is equipped with two paddles and each paddle is marked with the vessel's name.
Action required: 705 - Other - as specified
Due 12 October 2008
Resolved 18 September 2008
Fire Fighting › Fire Hoses › Condition
Issued 12 September 2008 Resolved
A hole was found in the fire hose located on the starboard bridge wing. Remove and/or replace damaged fire hose.
Action required: 705 - Other - as specified
Due 12 September 2008
Resolved 12 September 2008
Resolution: Vessel replaced damaged hose.
Engineering › Fuel Oil Service System › Valve
Issued 11 September 2007 Resolved
PRIOR TO CARRYING PASSENGERS, PROVE PROPER OPERATION OF EMERGENCY FUEL OIL SHUTDOWNS.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 September 2007
Resolved 11 September 2007
Deck/Cargo › Holds/Tanks › Ventilation Air Intake
Issued 11 September 2007 Resolved
IDENTIFY/LABEL ALL VENTS AND FILL PIPES ON MAIN DECK.
Action required: 705 - Other - as specified
Due 28 September 2007
Resolved 14 September 2007
Deck/Cargo › Marine Portable Tanks › Pipe Connection
Issued 11 September 2007 Resolved
PROVIDE AND INSTALL PLUG FOR MAIN DECK SEWAGE DISCHARGE PIPE.
Action required: 705 - Other - as specified
Due 28 September 2007
Resolved 14 September 2007
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 11 September 2007 Resolved
PROVIDE AND INSTALL NONCONDUCTING MATS OR GRATING ON THE DECK IN FRONT OF ENGINEROOM SWITCHBOARD AS PER 46 CFR 183.330(f).
Action required: 705 - Other - as specified
Due 28 September 2007
Resolved 14 September 2007
Operations/Management › Drills/Instruction › Fire
Issued 11 September 2007 Resolved
PROVIDE AND POST EMERGENCY INSTRUCTIONS.
Action required: 705 - Other - as specified
Due 28 September 2007
Resolved 14 September 2007
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 11 September 2007 Resolved
PROVIDE AND POST LIFEJACKET DONNING INSTRUCTIONS.
Action required: 705 - Other - as specified
Due 28 September 2007
Resolved 14 September 2007
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 11 September 2007 Resolved
PROVIDE WRITTEN REPORT ATTESTING TO THE SERVICING/TESTING OF ALL PORTABLE, SEMI-PORTABLE, FIXED FIRE EXTINGUISHER SYSTEMS AND ASSOCIATED EQUIPMENT (VISUAL/AUDIO ALARMS, HEAT/SMOKE DETECTORS, ETC).
Action required: 705 - Other - as specified
Due 28 September 2007
Resolved 14 September 2007
Deck/Cargo › Cargo Stowage › General
Issued 5 March 2007 Resolved
PROVIDE METHOD TO BLOCK VEHICLE WHEELS IN ACCORDANCE WITH 46 CFR 185.340
Due 7 March 2007
Resolved 11 September 2007
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 15 February 2007 Resolved
PROVIDE AND INSTALL A SPEED AND DISTANCE MEASURING DEVICE TO INDICATE SPEED AND DISTANCE THROUGH THE WATER NO LATER THAN NEXT DRYDOCKING AS PER SOLAS CHAPTER V, REG 19.2.3.4, 33 CFR 164.40 AND NAVIC 02-03.
Action required: 705 - Other - as specified
Due 15 June 2008
Resolved 9 December 2009
Resolution: Cleared. Device not in operation and not required unless owner requests international route. Requirement converted to a special note to document installation.
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 15 February 2007 Resolved
PROVIDE AND INSTALL A PROPERLY ADJUSTED TRANSMITTING HEADING DEVICE TO TRANSIT HEADING INFORMATION FOR INPORT TO THE EQUIPMENT REFERRED TO IN ITEM #1 ABOVE AS PER SOLAS CHAPTER V, REG 19.2.3.5 AND NVIC 02-03.
Action required: 705 - Other - as specified
Due 15 June 2008
Resolved 12 September 2008
Resolution: Company installed a transmitting heading device as per the SOLAS and NVIC 02-03.
Navigation › Electronic Positioning › GPS/DGPS Receiver
Issued 25 August 2006 Resolved
Provide CG Approval Series for GPS
Due 25 September 2006
Resolved 23 January 2007
Resolution: Installed CG approved GPS
Navigation › Collision/Grounding Avoidance › Radar Plotting Facilities
Issued 25 August 2006 Resolved
Provide Electronic Plotting Aid with USCG Approval
Due 25 September 2006
Resolved 23 January 2007
Resolution: Installed card into existing radar to enable plotting.
Navigation › Piloting/Steering › Magnetic Compass
Issued 25 August 2006 Resolved
Provide duplicate magnetic compass with CG Approval
Due 25 September 2006
Resolved 23 January 2007
Resolution: Provided duplicate mag compass.
Navigation › Piloting/Steering › Magnetic Compass
Issued 25 August 2006 Resolved
Provide Pelorus or Compass Bearing Device
Due 25 September 2006
Resolved 23 January 2007
Resolution: Pelorus purchased.
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 19 July 2006 Resolved
Provide oil transfer proceedures in accordance with 33 CFR Subpart C. To be completed prior to transfer of fuel oil. [name withheld] given a copy of MSDS for Diesel and a copy of the regulations. See Documents in the activity.
Condition: Unknown
Due 19 July 2006
Resolved 14 September 2007
Stability › Incline Test › General
Issued 19 July 2006 Resolved
Disable/Block fuel oil suction and return lines to the port and starboard fuel tanks between frames 14-18. To be completed prior to the issuance of the stability letter.
Condition: Improper Installation
Due 19 July 2006
Resolved 8 August 2006
Resolution: Modifications completed.
Documentation › Certificates/Documents › Cargo Ship Safety Radio Certificate
Issued 19 July 2006 Resolved
Provide a FCC Radio Safety Certificate.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 August 2006
Resolved 5 August 2006
Resolution: Certificate issued
Documentation › Certificates/Documents › Cargo Ship Safety Radio Certificate
Issued 19 July 2006 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 August 2006
Resolution: License issued.
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 19 July 2006 Resolved
Close opening in the 208/120 electrical distribution panel.
Condition: Unknown
Due 14 August 2006
Resolved 5 August 2006
Resolution: Openings Closed.
Stability › Incline Test › General
Issued 15 June 2006 Resolved
Awaiting issuance of Stability Letter by MSC.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 6 July 2006
Resolution: Vessel issued stability letter by MSC dated July 6, 2006 serial H1-0601734. See documents section for details and letters.

Casualty record · 5

27 September 2007Routine · role: Involved in a Marine Casualty · activity 3070998
4 July 2011Routine · role: Transiting Vicinity of Primary Subject · serious marine incident, as classified · activity 4069044
4 March 2013Routine · role: Involved in a Marine Casualty · activity 4543083
4 November 2017Routine · role: Involved in a Marine Casualty · activity 6300793
6 December 2025Routine · role: Involved in a Marine Casualty · activity 8281572
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

MISTER B (2007–2017). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.