Records from 1986 to 2025. Most recent: inspection, 1 August 2025.
Documentation record
Registered dimensions (L × B × D)78.2 ft × 26.1 ft × 7.4 ft
Registered tonnagegross 197 / net 134
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
Builderbuilder not recorded · BROWNSVILLE, PA, UNITED STATES · built 1973
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSHIPPINGPORT, PA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 21 April 2026 · expires 30 April 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it134 - Regulatory (Subpart C or D), Net Ton
197 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 39
1 August 2025
MTSA Verification · COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 8149807
13 June 2023
Administrative Inspection
Administrative · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7720134
28 October 2021
Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7371068
23 June 2020
TPO Audit
Administrative · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 6979991
5 May 2020
Initial Certification
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7023310
4 August 2018
Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 6507358
12 May 2015
Industry Initiated Exam
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 5147320
22 February 2014
Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 4810996
5 October 2013
Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 4739734
6 July 2013
Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 4647152
13 July 2011
Industry Initiated Exam · MTSA Verification
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 4094661
9 February 2009
Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 3414797
17 April 2007
Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 2910667
21 June 2005
Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 2406394
10 January 2005
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 2272803
2 December 2004
MTSA Verification
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 2268425
6 October 2004
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 2220935
22 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1981652
30 October 2003
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1939254
27 October 2003
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1938407
27 June 2003
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1939016
27 May 2003
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1802683
2 May 2003
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1784908
22 April 2003
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1778149
13 November 2002
Annual Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1704894
12 July 2001
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 214795
12 July 2001
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 292005
22 September 2000
Uninspected Towing Vessel
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 822617
6 May 1999
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 658832
2 March 1999
Uninspected Towing Vessel
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 806244
4 December 1997
Uninspected Towing Vessel
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 777951
20 October 1997
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 222311
1 November 1996
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 40801
1 November 1996
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 61293
29 October 1996
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 68537
16 December 1993
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 162013
14 January 1993
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 73397
27 May 1987
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 316408
17 July 1986
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 310328
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 1 August 2025
Resolved
A towing vessel must be maintained and operated so the watertight integrity and stability of the vessel are not compromised. Vessel's forwardmost void was found to have excessive water in space. Pump void dry and monitor space for water intrusion.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 August 2025
Resolved 4 August 2025
Resolution: TPO provided picture of void pumped dry.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 August 2025
Resolved
Electrical systems and equipment must function properly and minimize shock hazards. Breaker panel in pilothouse had missing breaker/blank. Install blank to prevent accidental electrocution.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 August 2025
Resolved 4 August 2025
Resolution: TPO provided picture of blank installed in panel.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 1 August 2025
Resolved
Closure devices must be provided for hull penetrations which open to the exterior of the vessel. Both MDE crankacse breather box drain lines were vented through the hull. The penetrations were not watertight and offered no means of closure. Hoses were not protected from abrasion.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 October 2025
Resolved 4 September 2025
Resolution: TPO provided close-out report.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Emergency preparedness
Issued 1 August 2025
Resolved
Safety orientations and other crew training must be documented. The newest crewmember (on for >24hrs) did not have the required safety orientation documented. Document orientation.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 August 2025
Resolved 1 August 2025
Resolution: TPO provided documentation showing orientation was conducted and recorded.