Inspection history · 53
8 March 2025
TPO Audit
Administrative · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 8104945
27 November 2023
TPO Audit
Administrative · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7829804
31 May 2023
In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7702026
19 May 2023
Type not recorded
No type recorded · STATION PITTSBURGH · USCG Heartland District (CGD-H) · Activity 7693954
10 May 2023
Administrative Inspection
Administrative · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7685452
3 October 2022
Deficiency Check
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7571668
18 July 2022
TPO Audit
Administrative · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7569314
14 June 2022
Damage Survey · Deficiency Check
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7476935
14 June 2022
Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7488673
13 May 2022
Administrative Inspection
Administrative · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7449876
17 May 2021
Administrative Inspection
Administrative · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7199241
2 October 2020
Initial Certification
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7057952
10 September 2020
TPO Audit
Administrative · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7054903
19 September 2019
Administrative Inspection
Administrative · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 6815978
28 April 2018
Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 6409316
22 June 2017
Industry Initiated Exam
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 6184331
16 November 2015
Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 5767215
26 April 2014
Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 4852560
31 January 2014
Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 4809730
14 April 2013
Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 4568447
12 December 2012
Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 4512535
3 August 2011
MTSA Verification · Industry Initiated Exam
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 4109504
14 November 2009
Type not recorded
No type recorded · Atlantic Area · Activity 3633492
14 November 2009
Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 3635542
20 December 2008
Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 3383565
26 August 2008
Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 3310193
20 February 2008
Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 3151666
11 January 2008
Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 3130091
17 October 2007
Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 3082937
17 September 2007
Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 3068261
25 April 2006
Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 2633637
30 November 2005
Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 2544924
30 November 2005
MTSA Verification
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 2545969
22 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1981648
30 October 2003
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1939254
11 September 2003
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1907913
27 June 2003
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1939016
28 May 2003
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1806050
13 November 2002
Annual Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1704873
19 June 2001
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 121932
18 January 2001
Annual Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1476906
13 June 2000
Uninspected Towing Vessel
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1050333
15 June 1999
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 145349
15 April 1999
Uninspected Towing Vessel
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1124246
20 February 1998
Uninspected Towing Vessel
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 783606
21 March 1996
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 175652
21 March 1996
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 217625
3 May 1995
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 753610
2 May 1995
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 195858
3 April 1994
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 66244
30 November 1993
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 108148
17 June 1993
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 75322
26 June 1987
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 317052
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Safety and environment policy
Issued 31 May 2023
Resolved
The TSMS, through policies, procedures, and documentation, must:
(a) Demonstrate management responsibility. The management must demonstrate that they implemented the policies and procedures as contained in the TSMS and the entire organization is adhering to their safety management program.
(b) Document management procedures. A TSMS must describe and document the owner or managing operator's organizational structure, responsibilities, procedures, and resources which ensure quality monitoring.
(c) Ensure document and data control. There must be clear identification of what types of documents and data are to be controlled, and who is responsible for controlling activities, including approval, issue, distribution, modification, removal of obsolete materials, and other related administrative functions.
(d) Provide a process and criteria for selection of third parties. Procedures for selection of TPOs must exist that include how third parties are evaluated, including selection criteria.(d) Provide a process and criteria for selection of third parties. Procedures for selection of TPOs must exist that include how third parties are evaluated, including selection criteria.
(e) Establish a system of recordkeeping. Records must be maintained to demonstrate effective implementation of the TSMS. This must include audit records, non-conformity reports and corrective actions, auditor qualifications, auditor training, and other records as considered necessary.
(f) Identify and meet training needs. The owner or operator must establish and maintain documented procedures for identifying training needs and providing training.
(g) Ensure adequate resources. Identify adequate resources and procedures necessary to comply with the TSMS.
Vessel master, crew, and management found to be unfamiliar/not in compliance with Towing Safety Management System (TSMS). Vessel is required to undergo External survey and audit demonstrating understanding and compliance with vessel TSMS to the satisfaction of the TPO. Vessel shall capture the following deficiencies IAW it's TSMS and to the satisfaction of the TPO.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 2 June 2023
Resolution: New 835V will be issued to be corrected within 6 months
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 31 May 2023
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Steering ram mount cracked. Repair steering system to original condition.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 June 2023
Resolution: Corrected to the satisfaction of TPO
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 31 May 2023
Resolved
The two required means of escape must be widely separated and, if possible, at opposite ends or sides of the space. Means may include normal and emergency exits, passageways, stairways, ladders, deck scuttles, doors, and windows. Emergency escape from machinery space blocked with line and firefighting equipment. Remove all gear in way of emergency escape.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 June 2023
Resolution: Corrected to the satisfaction of TPO
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 31 May 2023
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Open backed switchboard in engine room has conductive material stored in space. Remove material and train crew on the dangers of storing conductive material in restricted area.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 June 2023
Resolution: Corrected to the satisfaction of TPO
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 31 May 2023
Resolved
All seals and gaskets must be properly maintained to prevent leaks of flammable or combustible liquid, as those terms are defined in 46 CFR subpart 30.10, into the machinery space. All racor fuel filters leaking at drain plug and fuel is being accumulated in buckets. Repair all fuel leaks and properly dispose of leaked fuel.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 June 2023
Resolution: Corrected to the satisfaction of TPO
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 31 May 2023
Resolved
All bilges and void spaces are kept free from accumulation of combustible and flammable materials and liquids insofar as practicable. Machinery space bilges have inches of grease and oil accumulation. Clean bilges of all combustible/flammable material.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 June 2023
Resolution: Corrected to the satisfaction of TPO
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 31 May 2023
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Open backed switchboard in engine room has all electrical connections and equipment are covered with soot/debris. Clean all electrical to prevent fire.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 June 2023
Resolution: Corrected to the satisfaction of TPO
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 31 May 2023
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Exhaust leak found on port generator. Repair leak as required.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 June 2023
Resolution: Corrected to the satisfaction of TPO
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 31 May 2023
Resolved
Flammable and combustible products must not be stored in machinery spaces, unless they are stored in a suitable container that meets the requirements of § 142.225 of this subchapter. Aerosol cans containing flammable liquids stored in machinery spaces. Store all flammable/combustible products in approved containers.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 June 2023
Resolution: Corrected to the satisfaction of TPO
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 31 May 2023
Resolved
The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector or TPO, as applicable. If any of the equipment or records have not been properly maintained, a qualified servicing facility must perform the required inspections, maintenance procedures, and hydrostatic pressure tests. Inspectors found multipool tags missing inspections on portable fire extinguishers. Also, crew was questioned on how monthly portable fire extinguishers are inspected and crew flaile to know where inspection procedures were located or how to properly inspect extinguishers. Have all portable fire extinguishers inspected by a qualified service facility and train crew on proper monthly inspection procedures.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 June 2023
Resolution: Corrected to the satisfaction of TPO
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 31 May 2023
Resolved
Portable and semi-portable fire extinguishers must be inspected, maintained, and tested in accordance with the inspection, maintenance procedures, and hydrostatic pressure tests required by Chapters 7 and 8 of NFPA 10, Standard for Portable Fire Extinguishers. Monthly inspections required by NFPA 10 may be conducted by the owner, operator, person-in-charge, or a designated member of the crew. Crew missed monthly inspections on fire extinguishers. Complete monthly inspections on all portable fire extinguishers as required.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 June 2023
Resolution: Corrected to the satisfaction of TPO
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 31 May 2023
Resolved
Pressure vessels must be externally examined annually. Relief valves must be tested in accordance with § 143.245 (Twice in 5 years not to exceed 3 years.) All pressure relief valves have exceeded 3 years from last test. Test or replace with new all pressure relief valves and document as required.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 June 2023
Resolution: Corrected to the satisfaction of TPO
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 31 May 2023
Resolved
The master or officer in charge of a navigational watch must ensure all hatches and openings of the hull and deck are kept tightly closed. Multiple water tight hatches found open on deck. Properly close all watertight hatches.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 June 2023
Resolution: Corrected to the satisfaction of TPO
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 31 May 2023
Resolved
Electrical connections must be suitably installed to prevent them from coming loose through vibration or accidental contact. Starboard generator battery cables loose. Tighten cables as required.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 June 2023
Resolution: Corrected to the satisfaction of TPO
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 31 May 2023
Resolved
Electrical connections must be suitably installed to prevent them from coming loose through vibration or accidental contact. Main diesel engine battery connections loose. Tighten battery cables
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 June 2023
Resolution: Corrected to the satisfaction of TPO
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 31 May 2023
Resolved
Piping and machinery components that exceed 220 °C (428 °F), including fittings, flanges, valves, exhaust manifolds, and turbochargers, must be insulated. Port main engine turbo charger missing insulation. Install insulation as required.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2023
Resolved 2 June 2023
Resolution: Corrected to the satisfaction of TPO
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 31 May 2023
Resolved
Electrical connections must be suitably installed to prevent them from coming loose through vibration or accidental contact. Permanent extension cord found installed for permanent deck lighting. Permanently connect deck lighting into electrical system.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2023
Resolved 2 June 2023
Resolution: Corrected to the satisfaction of TPO
09 - Working and Living Conditions › 092 - Working Conditions › Obstruction/slipping, etc.
Issued 31 May 2023
Resolved
The owner or managing operator must implement procedures to identify and mitigate health and safety hazards, including Slips, trips and falls. Deck plating in engine room bent and not properly secured posing a tripping hazard. Repair all engine room tripping hazards
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2023
Resolved 2 June 2023
Resolution: Corrected to the satisfaction of TPO
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 31 May 2023
Resolved
Means must be provided for stopping each fan in a ventilation system serving machinery spaces and for closing, in case of fire, each doorway, ventilator, and annular space around funnels and other openings into such spaces. Lever for securing engine room air dampener is broken. Repair as required.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2023
Resolved 2 June 2023
Resolution: Corrected to the satisfaction of TPO
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 31 May 2023
Resolved
Electrical connections must be suitably installed to prevent them from coming loose through vibration or accidental contact. Mast head light found to be wired to an extension word and then plug into an outlet. Permanently connect navigation lights to electrical system.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2023
Resolved 2 June 2023
Resolution: Corrected to the satisfaction of TPO
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Other (ISM)
Issued 31 May 2023
Resolved
The TSMS, through policies, procedures, and documentation, must:
(a) Demonstrate management responsibility. The management must demonstrate that they implemented the policies and procedures as contained in the TSMS and the entire organization is adhering to their safety management program.
(b) Document management procedures. A TSMS must describe and document the owner or managing operator's organizational structure, responsibilities, procedures, and resources which ensure quality monitoring.
(c) Ensure document and data control. There must be clear identification of what types of documents and data are to be controlled, and who is responsible for controlling activities, including approval, issue, distribution, modification, removal of obsolete materials, and other related administrative functions.
(d) Provide a process and criteria for selection of third parties. Procedures for selection of TPOs must exist that include how third parties are evaluated, including selection criteria.
(e) Establish a system of recordkeeping. Records must be maintained to demonstrate effective implementation of the TSMS. This must include audit records, non-conformity reports and corrective actions, auditor qualifications, auditor training, and other records as considered necessary.
(f) Identify and meet training needs. The owner or operator must establish and maintain documented procedures for identifying training needs and providing training.
(g) Ensure adequate resources. Identify adequate resources and procedures necessary to comply with the TSMS.
Vessel master, crew, and management found to be unfamiliar/not in compliance with Towing Safety Management System (TSMS). Vessel is required to undergo External survey and audit demonstrating understanding and compliance with vessel TSMS to the satisfaction of the TPO.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 December 2023
Resolved 28 November 2023
Resolution: External survey and audits completed.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Other (ISM)
Issued 14 June 2022
Resolved
The TSMS, through policies, procedures, and documentation, must:
(a) Demonstrate management responsibility. The management must demonstrate that they implemented the policies and procedures as contained in the TSMS and the entire organization is adhering to their safety management program.
(b) Document management procedures. A TSMS must describe and document the owner or managing operator's organizational structure, responsibilities, procedures, and resources which ensure quality monitoring.
(c) Ensure document and data control. There must be clear identification of what types of documents and data are to be controlled, and who is responsible for controlling activities, including approval, issue, distribution, modification, removal of obsolete materials, and other related administrative functions.
(d) Provide a process and criteria for selection of third parties. Procedures for selection of TPOs must exist that include how third parties are evaluated, including selection criteria.(d) Provide a process and criteria for selection of third parties. Procedures for selection of TPOs must exist that include how third parties are evaluated, including selection criteria.
(e) Establish a system of recordkeeping. Records must be maintained to demonstrate effective implementation of the TSMS. This must include audit records, non-conformity reports and corrective actions, auditor qualifications, auditor training, and other records as considered necessary.
(f) Identify and meet training needs. The owner or operator must establish and maintain documented procedures for identifying training needs and providing training.
(g) Ensure adequate resources. Identify adequate resources and procedures necessary to comply with the TSMS.
Vessel master, crew, and management found to be unfamiliar/not in compliance with Towing Safety Management System (TSMS). Vessel is required to undergo External survey and audit demonstrating understanding and compliance with vessel TSMS to the satisfaction of the TPO.
Condition: Design Flaw
Action required: 10 - Deficiency Rectified
Due 14 July 2022
Resolved 29 September 2022
Resolution: External Survey and audit completed to the satisfaction of the TPO.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 14 June 2022
Resolved
The master must ensure that all hatches, doors, and other openings designed to be watertight or weather-tight function properly. Aft port fuel tank deck hatch cover and lower tank suction valve do not seal allowing fuel to discharge when pressed up. Multiple watertight deck hatches found loose.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 13 July 2022
Resolved 4 October 2022
Resolution: Hatch cover repaired and reseated. Suction valve removed and through hull capped to the satisfaction of the attending inspector.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 14 June 2022
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 10 - Deficiency Rectified
Due 14 July 2022
Resolved 4 October 2022
Resolution: Medical card received as required.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 June 2022
Resolved
No person may connect or disconnect a hose, top off a tank, or engage in any other critical procedures during the transfer operation unless the person in charge, required by § 156.120(s), supervises that procedure. Vessel TSMS fuel transfer procedures not in alignment with regulatory requirements.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 June 2022
Resolved 28 June 2022
Resolution: Vessel rep provided updated TSMS policy and procedures.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 14 June 2022
Resolved
Towing vessels more than 65 feet in length must use navigation lights that meet UL 1104 (incorporated by reference, see § 136.112 of this subchapter) or other standards accepted by the Coast Guard.
Bottom Stern tow-light extinguished. Non-UL 1104 Amber colored work light hung IWO extinguished stern light.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 June 2022
Resolved 28 June 2022
Resolution: Replaced extinguished tow light with UL- 1104 approved model.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 14 June 2022
Resolved
(a) Carriage requirement. A towing vessel must carry a combination of day and night visual distress signals indicated in Table 141.370 of § 141.370 for specified areas where the vessel operates.
(b) Day and night visual distress signals. Hand-held red flare distress signals, approved under approval series 160.021 or 160.121, and hand-held rocket-propelled parachute red flares, approved under approval series 160.036 or 160.136, are acceptable as both day and night signals.
Vessel has one expired hand red flare and is missing third hand red flare.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 June 2022
Resolved 28 June 2022
Resolution: Replaced all hand red flares.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 14 June 2022
Resolved
Each exhaust pipe from an internal combustion engine which is within reach of personnel must be insulated or otherwise guarded to prevent burns. Both generators exhaust manifolds only partially insulated.
Condition: Design Flaw
Action required: 10 - Deficiency Rectified
Due 14 July 2022
Resolved 4 October 2022
Resolution: Insulation installed on both generator exhaust manifolds.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 June 2022
Resolved
Electrical equipment and electrical cables must be suitably protected from wet and corrosive environments. F/O transfer pump J-box missing port cover.
Action required: 10 - Deficiency Rectified
Due 14 July 2022
Resolved 4 October 2022
Resolution: Port cover on juntion box capped off.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 14 June 2022
Resolved
Each lifejacket must be marked: (1) In block capital letters with the name of the vessel;
Lifejackets in galley labelled "Aliquippa".
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 14 July 2022
Resolved 4 October 2022
Resolution: Two lifejackets in galley labelled correctly with vessel name.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 June 2022
Resolved
Extension cords must not be used as a permanent connection to a source of electrical power. Permanent extension cord installed in galley, and aft steering.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 14 July 2022
Resolved 4 October 2022
Resolution: Extension cords removed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 June 2022
Resolved
At least two lifebuoys on a towing vessel greater than 26 feet must be fitted with a floating electric water light approved under approval series 161.010 or 161.110, unless the towing vessel is limited to daytime operation, in which case no floating electric water light is required. Float lights did not energize.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 July 2022
Resolved 28 June 2022
Resolution: float lights all functioned as required.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 June 2022
Resolved
Each lifebuoy on a towing vessel must: (4) Be marked in block capital letters with the name of the vessel;
02 life buoys missing vessel name.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 July 2022
Resolved 28 June 2022
Resolution: Life bouys correctly labelled.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 June 2022
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. the following dead end wires were found: Starboard side bulkhead of forward deck space & over steering gear hydraulic tank.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 14 July 2022
Resolved 4 October 2022
Resolution: Dead end wires removed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 14 June 2022
Resolved
Paints, coatings, or other flammable or combustible products onboard a towing vessel must be stored in a designated storage room or cabinet when not in use.
Paint and unsecured compressed gas cylinder being stored in starboard side compressor room annex.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 July 2022
Resolved 28 June 2022
Resolution: All flammable materials and cylinders removed from space.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 June 2022
Resolved
Twist-on type of connectors may not be used for making joints in cables, facilitating a conductor splice, or extending the length of a circuit. Port side engine room bilge pump spliced with twist-on connectors.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 July 2022
Resolved 28 June 2022
Resolution: Old system. removed from service.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 June 2022
Resolved
If twist-on types of connectors are used, the connections must be made within an enclosure and the insulated cap of the connector must be secured to prevent loosening due to vibration. Compressor room general alarm light installed with twist-on connectors not in enclosure.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 14 July 2022
Resolved 4 October 2022
Resolution: Connections placed inside enclosure.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 June 2022
Resolved
Electrical components that pose an electrical hazard must be in an enclosure. Outlet inboard of port side engine shaft missing faceplate.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 July 2022
Resolved 28 June 2022
Resolution: Old system. removed from service.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 14 June 2022
Resolved
Rails or equivalent protection must be installed near the periphery of all decks accessible to crew. Equivalent protection may include lifelines, wire rope, chains, and bulwarks that provide strength and support equivalent to fixed rails. No fall protection installed between tow knees.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 July 2022
Resolved 28 June 2022
Resolution: Chain installed between tow knees.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 14 June 2022
Resolved
Each watertight door and watertight hatch must be marked on both sides in clearly legible letters at least 25 millimeters (1 inch) high: “WATERTIGHT DOOR - KEEP CLOSED” or “WATERTIGHT HATCH - KEEP CLOSED”. All main deck hatches missing labeling.
Action required: 10 - Deficiency Rectified
Due 14 July 2022
Resolved 4 October 2022
Resolution: Hatches labelled as required.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 June 2022
Resolved
Electrical equipment and electrical cables must be suitably protected from wet and corrosive environments. Electrical control box in forward deck space open and unsecure, Bilge switches in aft steering and engine room engine shaft spaces missing covers.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 14 July 2022
Resolved 4 October 2022
Resolution: Covers secured or replaced as required.