Records from 1993 to 2026. Most recent: inspection, 21 April 2026.
Documentation record
Registered dimensions (L × B × D)59.3 ft × 22.0 ft × 8.8 ft
Registered tonnagegross 76 / net 61
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderHOUMA SHIPBUILDING INC · HOUMA, LA, UNITED STATES · built 1973
Hull materialSteel
PropulsionDiesel
Hull shapeShip
Hull configurationMonohull
Hailing portFERNANDINA BEACH, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 20 February 2026 · expires 31 March 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it61 - Simplified, Net Ton
76 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 31
21 April 2026
Annual Inspection · Deficiency Check
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 8353641
24 September 2025
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8240713
24 June 2025
In-Service Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8165513
21 January 2025
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8068989
21 October 2024
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8022179
17 August 2024
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7986743
12 March 2024
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7877088
25 January 2023
COI Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7625825
13 October 2021
Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7331038
21 April 2020
Initial Certification
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6948647
26 December 2019
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6879003
24 December 2019
Administrative Inspection · Damage Survey
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6879110
4 March 2019
Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6650278
16 August 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6513593
13 September 2012
Risk-based Targeted Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4439688
18 January 2012
Administration
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4226989
8 April 2011
Type not recorded
No type recorded · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3986219
11 May 2007
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3001605
22 June 2006
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2688076
8 February 2006
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2581646
16 June 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2392789
12 May 2005
Annual Inspection · MTSA Verification
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2356059
21 April 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2339916
30 January 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1998721
25 June 2003
Type not recorded
No type recorded · Station Georgetown · USCG Southeast District (CGD-SE) · Activity 1826409
29 November 2001
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 66099
2 March 1999
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 764260
5 January 1999
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 196676
21 January 1995
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 185752
15 August 1993
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 20177
4 August 1993
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 76006
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 24 June 2025
Resolved
Decks and bulkheads designed to be watertight or weathertight must be maintained in that condition.
There is a hole in the stbd fuel tank, into the stbd fwd eng room. Hole must be repaired prior to departure to prevent fuel/vapors from freely communicating with the engine room.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 July 2025
Resolution: Damage between E/R, fuel tank, and main deck repaired and tested sat.
09 - Working and Living Conditions › 092 - Working Conditions › Winches & capstans
Issued 24 June 2025
Resolved
Towing machinery used to connect the towing vessel to the tow must be suitable for its intended service. The stern tow winch has extremely wasted foundation, which is not to be used until properly repaired and tested for its intended service.
Action required: 705 - Other - as specified
Resolved 21 April 2026
Resolution: Deficiency was cleared at the last drydock inspectiion.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 20 July 2020
Resolved
Hole identified on starboard side rub rail. Make repairs and prove to attending CG marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 August 2020
Resolution: Received video of repairs.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 20 July 2020
Resolved
VHF radios did not have GPS position information properly inputted. Input GPS information and prove proper operation.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 July 2020
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 20 July 2020
Resolved
Remove oily water accumulated in the engine room.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 August 2020
Resolution: Received proof of removal.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 July 2020
Resolved
Starboard shaft seal was leaking considerably. Make repairs and prove satisfaction to attending marine inspector.
Action required: 10 - Deficiency Rectified
Resolved 27 July 2020
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 20 July 2020
Resolved
Emergency light was inoperable on the deck below the bridge. Make repairs and prove proper operation.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 July 2020
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 24 December 2019
Resolved
Vessel reported that there was a hole identified in the engine room space below the waterline causing water ingress. A temporary patch is in place while the vessel is intentionally aground. Submit a proposed repair and transit plan prior to moving the vessel.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 26 December 2019
Resolution: Received satisfactory transit plan.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 24 December 2019
Resolved
Once a transit and repair plan is accepted, make permanent repairs to the damaged area to the satisfaction of an attending marine inspector.
Action required: 705 - Other - as specified
Resolved 24 February 2020
Resolution: Hull repairs completed.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 16 August 2018
Resolved
Vsl is broadcasting: No IMO #.
Condition: Invalid
Action required: 705 - Other - as specified
Due 16 September 2018
Resolved 17 August 2020