ILLINOIS

ILLINOIS is a 1977 industrial vessel. The Coast Guard has recorded 22 inspections since 2016, most recently in June 2025, along with 41 deficiencies and 5 casualty investigations between 2007 and 2022.

Records from 2007 to 2025. Most recent: inspection, 12 June 2025.

Built
1977
Last inspected
12 June 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

WYQ3689
Flag
UNITED STATES
Maury page id
psix-49085

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 2016.

Inspections, by type

…with no type recorded5
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Registered dimensions (L × B × D)211.2 ft × 67.0 ft × 12.5 ft
Registered tonnagegross 2,069 / net 620
ITC dimensions (L × B × D)211.2 ft × 67.0 ft × 12.5 ft
ITC tonnagegross 2,069 / net 620
BuilderAVONDALE SHIPYARDS INC · AVONDALE, LA, UNITED STATES · built 1977
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW YORK, NY
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 3 August 2026 · expires 30 September 2027
Service, as the file records itIndustrial Vessel
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it2069 - Convention (Subpart B), Gross Ton
620 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

What it gives that this page does not: the whole record in one dated, citable document — every line with its Coast Guard activity id, the retrieval date on the cover, built to print to PDF with its page breaks — that a surveyor can attach and a lender can file. The same facts as this page, complete and in one file.

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

A request, not a checkout: leave an email and Maury replies once, with the dated document for this hull and a Stripe invoice for $299. Nothing is charged before the document is in your hands.

Inspected as a tow unit · 5

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

DERRICK 66 Industrial Vessel · MISLE 266557 · 24 December 2022 · activity 7616800EMILY A HEBERT Towing Vessel · MISLE 16970 · 26 December 2019 · activity 6879003BAYOU BRAVE Towing Vessel · MISLE 121007 · 26 December 2019 · activity 6879003FUEL BARGE 1001 Tank Barge · MISLE 1272290 · 5 April 2017 · activity 6118565ATLANTIC DAWN Towing Vessel · MISLE 491242 · 19 February 2016 · activity 5824154

Inspection history · 22

12 June 2025 Drydock Exam · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8117801
4 October 2024 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8012635
1 February 2024 MTSA Verification · In-Service Inspection · Periodic Inspection · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7857883
7 June 2023 Internal Structural Exam · Drydock Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7704837
24 December 2022 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7616800
7 December 2022 MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7615738
13 December 2021 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7381603
9 November 2021 Deficiency Check · MTSA Verification · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7348186
18 May 2020 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6955358
15 April 2020 Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6939515
26 December 2019 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6879003
28 November 2019 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6865701
22 April 2019 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6660551
11 October 2018 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6559315
17 April 2018 Periodic Inspection · Drydock Exam · MTSA Verification · Examination of Repairs · Hull Examination · In-Service Inspection · Internal Structural Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6390426
6 June 2017 MTSA Verification · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6165936
5 April 2017 Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6118565
23 December 2016 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6061676
22 July 2016 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 5949234
1 July 2016 Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 5921751
6 June 2016 MTSA Verification · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5899260
19 February 2016 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5824154

Deficiency record · 41

07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 4 October 2024 Resolved
Portable fire extinguishers and their stations must be numbered in accordance this subchapter. Each hand portable fire extinguisher shall be marked with a number and the location where stowed shall be marked with a corresponding number at least 1/2 inch high. All portable fire extinguishers were not numbered appropriately per the regulation. 46 CFR 95.50-10(e) 46 CFR 97.37-23(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 October 2024
Resolved 8 October 2024
Resolution: Vessel rep sent in objective evidence, attached to this activity.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 4 October 2024 Resolved
All general alarm bells shall be identified by red lettering at least 1/2 inch high:“GENERAL ALARM—WHEN BELL RINGS GO TO YOUR STATION.”. The bridge and galley general alarms were not marked. Several machinery space general alarms have paint covering part of the signs. 46 CFR 97.37-7(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 October 2024
Resolved 8 October 2024
Resolution: Vessel rep sent in objective evidence, attached to this activity.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 4 October 2024 Resolved
Electric installations on vessels must ensure: Protection of passengers, crew, other persons, and the vessel from electrical hazards. Port side survival craft light lens is spider cracked throughout. 46 CFR 111.01-1(a)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 October 2024
Resolved 8 October 2024
Resolution: Vessel rep sent in objective evidence, attached to this activity.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 4 October 2024 Resolved
Retro-reflective material. The lifebuoys shall be fitted with retro-reflective material (tape) with a minimum of 5 cm (2 inches) width around the lifebuoy at four locations spaced equally around the circumference of the Retro-reflective material shall be Type II material that is approved under 46 CFR 164.018. The ring buoys have DOT reflective tape and not the approved Type I or Type II retro-reflective material. 46 CFR 199.70(a) 46 CFR 164.018
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 October 2024
Resolved 8 October 2024
Resolution: Vessel rep sent in objective evidence, attached to this activity.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 4 October 2024 Resolved
Approved portable fire extinguishers and semi-portable fire extinguishing systems must be installed in accordance with Table 95.50-10(a) of this section. The location of the equipment must be to the satisfaction of the Officer in Charge, Marine Inspection. The spare cylinders are not stored securely and are sitting on the deck creating a potential hazardous situation. 46 CFR 95.50-10(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 October 2024
Resolved 8 October 2024
Resolution: Vessel rep sent in objective evidence, attached to this activity.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 1 February 2024 Resolved
Each vessel must carry not less than 12 rocket parachute flares approved under approval series 160.136. Vessel did not have req'd number of flares meeting 46CFR160.136 46CFR199.60
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 February 2024
Resolution: MI verified 12 distress signals on board
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage management plan
Issued 1 February 2024 Resolved
A manned oceangoing ship of 40' or more in length is required to maintain a Garbage Management Plan IAW 46CFR151.57. Vessel does not maintain a Garbage Management Plan 46CFR151.51(d)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 8 February 2024
Resolution: MI verified garbage management plan on board.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 7 June 2023 Resolved
FWD bulkhead of engine room space was found holed and & approx 10 bottom vertical frmaes were found wasted.
Action required: 705 - Other - as specified
Due 18 August 2023
Resolved 4 October 2023
Resolution: A scantling reassessment was completed by ABS and PE and uploaded in MISLE.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 9 November 2021 Resolved
Engine design - all installations shall be of marine type engines suitable for the intended service, designed and constructed in conformance with the requirements of this Subchapter. Found main generator's cooling plates removed for cleaning & replacement.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 November 2021
Resolution: Vessel installed cooling plates. Test ran engine.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 9 November 2021 Resolved
Each vessel must carry a category 1-406 MHz satellite EPIRB meeting the requirements of 47 CFR part 80. The EPIRB did not have a registration decal affixed.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 November 2021
Resolved 13 December 2021
Resolution: Vessel EPIRB NOAA registration was verified and registration decal was affixed to the EPIRB unit.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 November 2021 Resolved
Vent outlets from all tanks which may emit flammable or combustible vapors must be fitted with a flame screen of 30x30 mesh. Two fuel tank vents were missing flame screens.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 November 2021
Resolved 15 November 2021
Resolution: Flame screens were installed on goose neck vents.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 November 2021 Resolved
Satisfactory means, permanently attached, shall be provided for closing the openings of all vents. Two fuel tank vents were missing the ball check valves.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 November 2021
Resolved 15 November 2021
Resolution: Ball check valves installed on goose neck vents.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 9 November 2021 Resolved
Fixed Halon firefighting system cylinders must be tested and marked as required by 46 CFR 147. Halon compressed gas cylinders have not been marked with the latest visual 5-year inspection with RIN as required.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 November 2021
Resolved 15 November 2021
Resolution: Halon compressed gas cylinders were marked as being inspected visually by fire servicing company and paperwork was signed for vessel indicating the same.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 9 November 2021 Resolved
It shall be the duty of the Master, or person in charge, to see that the vessel's firefighting equipment is at all times ready for use, and that all such equipment is maintained. The nitrogen time delay bottle for the fixed halon system is not mounted in a manufacturer's approved bracket.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 November 2021
Resolved 15 November 2021
Resolution: Nitrogen time delay bottle was mounted in its bracket.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 9 November 2021 Resolved
The boundary bulkheads and decks separating accommodations from machinery spaces shall be of "A" class construction. There are open deck penetrations in the galley deck over the machinery space below.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 November 2021
Resolved 15 November 2021
Resolution: Deck penetrations were capped.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 9 November 2021 Resolved
Crop and renew to good metal the wasted/holed deck (ovhd of accommodation space below) iwo port door outside wheelhouse to the satisfaction of the attending CG Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 November 2021
Resolved 22 November 2021
Resolution: Deck insert iwo pilthouse was final weld tested; all sat.
14 - Pollution Prevention › 141 - MARPOL Annex I › Control of discharge
Issued 9 November 2021 Resolved
At each inspection, the inspector shall examine the vessel to determine it meets the vessel design and equipment requirements for pollution prevention. The ladder pump motor expansion tank and pump system is leaking oil at multiple pipe connections, the relief valve, and discharge side of pump. 705 C - Other: Prior to operating equipment.
Action required: 705 - Other - as specified
Resolved 15 November 2021
Resolution: All pipe connections were refitted and sealed and system was pressure tested at working pressure; all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 November 2021 Resolved
Electrical apparatus and wiring systems shall be in accordance with the requirements of this part. Found dead end wire at overhead light port side generator room. 46 CFR 111.05-1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 November 2021
Resolved 15 November 2021
Resolution: Vessel confirmed wire had no voltage. Wire secured in junction box.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 November 2021 Resolved
The door of each panel board enclosure that is accessible must have a locking device. Found four electrical panel doors in MCC room on the port side missing securing devices. 46 CFR 111.40-1(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 November 2021
Resolved 15 November 2021
Resolution: Vessel installed panel board enclosure securing devices.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 November 2021 Resolved
Electrical apparatus and wiring systems shall be in accordance with the requirements of this part. Found permanently mounted lighting fixture behind engineering booth with cable plugged into an outlet. 46 CFR 111.05-1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 November 2021
Resolved 15 November 2021
Resolution: Vessel permanently wired mounted light.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 9 November 2021 Resolved
Fixture globes shall be protected by guards. Found overhead light port side upper engine room without lens cover. 46 CFR 111.75-20(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 November 2021
Resolved 15 November 2021
Resolution: Vessel installed light with lens cover.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 9 November 2021 Resolved
Electric installations on vessels must ensure protection of crew and the vessel from electrical hazards. Found emergency light on bow space bulkhead secured together with electrical tape. 46 CFR 111.05-15(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 November 2021
Resolved 15 November 2021
Resolution: Vessel installed inkind emergency light. Light tested SAT.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 22 April 2019 Resolved
Three ventilation trunks were found wasted between leouvers next to operating station. Repair to the satisfaction of attending Coast Guard Marine Inspector. (46 CFR 92.15-10)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 April 2019
Resolution: Approved temporary repaires were made in place of louvers. See "special note" for when permanent repairs need to be completed.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 22 April 2019 Resolved
Found bond-o patch on deck. Repair to the satisfaction of attending Coast Guard Marine Inspector. (46 CFR 92.07-10)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 April 2019
Resolution: A 2" by 4" steel plate was welded in place of bond-o patch on deck.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 22 April 2019 Resolved
One smoke detector was missing, one smoke detector was inoperable. Replace missing smoke detector and repair other smoke detector to the satisfaction of attending Coast Guard Marine Inspector. (46 CFR 95.05-1)
Action required: 17 - Rectify deficiencies prior to departure
Due 1 May 2019
Resolved 1 May 2019
Resolution: Detector re-installed
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 April 2019 Resolved
Found wire under ventilation system next to operating station missing sheathing. Repair to the satisfaction of attending Coast Guard Marine Inspector. (46 CFR 111.60-11 (c))
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 May 2019
Resolved 25 April 2019
Resolution: Sheathing was replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 22 April 2019 Resolved
Found a hole in the auxiliary generator cooling line. Repair to the satisfaction of attending Coast Guard Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 May 2019
Resolved 25 April 2019
Resolution: Hole in pipe was repaired by cropping and renewing.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 April 2019 Resolved
Found wastage hole on battery box. Repair to the satisfaction of attending Coast Guard Marine Inspector. (46 CFR 111.15-5(g))
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 May 2019
Resolved 25 April 2019
Resolution: Wastage hole was repaired.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 April 2019 Resolved
Two blanks were missing from distribution panel in gyro room. Replace missing blanks in distribution panel to the satisfaction of attending Coast Guard Marine Inspector. (46 CFR 111.50-7)
Action required: 10 - Deficiency Rectified
Resolved 22 April 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 22 April 2019 Resolved
RACOR filter on auxiliary generator was missing an O-ring. Replace O-ring to the satisfaction of attending Coast Guard Marine Inspector. (46 CFR 56.15-5)
Action required: 10 - Deficiency Rectified
Resolved 22 April 2019
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 22 April 2019 Resolved
While conducting fixed fire system test, MI discovered wasted drain line that was allowing free communication through the side of the sideshell & the Halon room.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 29 April 2019
Resolved 29 April 2019
Resolution: Repairs made to the satisfaction of attending Marine Inspector.
Electrical › Electric Generation Source (service) › Circuit Breaker
Issued 13 June 2016 Resolved
Repair synchronization means & reverse current relay for gens, or means of interlock. Cite: 46 CFR 111.30-25(d); 46 CFR 111.12-11(f)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 July 2016
Resolved 5 July 2016
Resolution: Vessel installed interlock switch.
Electrical › Electric Generation Source (service) › Generator Cable
Issued 13 June 2016 Resolved
Aux generator was installed w/improper cable to starter & switchboard. Install proper electrical cable to the satisfaction of the attending CG [name withheld]: 46 CFR 111.60 Due date: Prior to using aux generator.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 13 June 2016
Resolved 18 June 2016
Engineering › Diesel Engine (auxiliary) › Diesel Engine Relating to Air Pollution Control
Issued 13 June 2016 Resolved
Provide proof that the aux gen meets U.S. EPA Emission regulations in 40 CFR Part 94. Cite: 40 CFR 94; CG Policy Letter 09-01 Due date: 30 June 2015.
Due 22 June 2016
Resolved 20 June 2016
Engineering › Fuel Oil Service System › Hose
Issued 13 June 2016 Resolved
Provide list of all fuel hoses installed on aux generator; ensure they meet SAE-J1942. Cite: 46 CFR 56.60-25(b) Due date: Prior to using aux generator.
Action required: 705 - Other - as specified
Due 13 June 2016
Resolved 18 June 2016
Fire Fighting › Fixed Halon Fire Extinguishing System › Tanks
Issued 13 June 2016 Resolved
Contract fire servicing technician with a DOT Requalification Identification Number to conduct the required 5-year visual inspection of all overdue fixed Halon cylinders onboard. Provide servicing report to the satisfaction of the attending CG [name withheld]: 46 CFR 97.15-60(b), 46 CFR 91.25-20(a)(2), 46 CFR 147.67(a)(2), 49 CFR 180.209(g); Due date: PRIOR TO SAILING
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 13 June 2016
Resolved 18 June 2016
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 13 June 2016 Resolved
Port-fwd ventilation damper did not close properly during fixed firefighting sys test. Demonstrate proper shutdown/closure of port forward ventilation damper to CG [name withheld]: 46 CFR 95.16-30 Due Date: PRIOR TO SAILING
Action required: 17 - Rectify deficiencies prior to departure
Due 13 June 2016
Resolved 18 June 2016
Engineering › Diesel Engine (auxiliary) › Emergency shutdown
Issued 13 June 2016 Resolved
Aux generator is required to automatically shutdown upon activation of the fixed Halon system. Provide proposal for installation of automatic shutdown upon activation of fixed system. Contact CG MI to verify install and witness testing of shutdown. Cite: 46 CFR 91.25-20, NVIC 6-72 (Enc 1, part IV); Due date: Prior to using aux generator.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 13 June 2016
Resolved 18 June 2016
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 13 June 2016 Resolved
Properly indicate open & closed positions of stbd side ventilation dampers w/stenciling. Cite: 46 CFR 95.16-30 Due date: 21 JUNE 2016
Action required: 705 - Other - as specified
Due 21 June 2016
Resolved 18 June 2016
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 7 June 2016 Resolved
Vessel is required to conduct operational testing of fixed fire-fighting system in presence of CG MI annually. Contact CG MI to witness operational testing of system by servicing technician. Testing is to include all time delays, alarms, & ventilation shut-downs. Cite: 46 CFR 97.15-60(b), 46 CFR 91.25-20(a)(2) Due: PRIOR TO OPERATING
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 7 June 2016
Resolved 13 June 2016
Resolution: Witnessed testing of fixed system including time-delays, & audible shutdowns; all sat. Portside fwd ventilation damper did not close properly issued separate CG-835. Aux gen does not have automatic shutdown installed; issued separate CG-835.
Electrical › Electric Generation Source (service) › Generator
Issued 7 June 2016 Resolved
Vessel has new installed auxiliary generator. Complete plan approval process for new install with USCG Marine Safety Center. Plans are to include all technical specifications for gen, line drawings, & load calc's. Provide evidence of plan approval to local USCG [name withheld]: 46 CFR 96.05-1(a); 46 CFR 110.30-7 Due date: 15 July 2016
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 October 2016
Resolved 23 December 2016
Resolution: Approved plans and letters are in vessels history from MSC

Casualty record · 5

24 August 2007Routine · role: Involved in a Marine Casualty · activity 3037301
23 April 2013Routine · role: Moored/Anchored in Vicinity of Primary Subject · serious marine incident, as classified · 1 dead · activity 4575236
19 February 2016Routine · role: Involved in a Marine Casualty · activity 5824154
26 December 2019Routine · role: Moored/Anchored in Vicinity of Primary Subject · activity 6879003
24 December 2022Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 7616800
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.