Documentation record
Registered dimensions (L × B × D)Not recorded
Registered tonnagegross 83 / net 66
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderST.LOUIS · built 1973
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portST LOUIS, MO
Endorsements, as the file codes themcw_un
DocumentationValid · issued 5 September 2025 · expires 31 October 2026
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it83 - Simplified, Gross Ton
66 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel
Behind this panel: 28 inspections, each with its date, unit and type; 23 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 25 other vessels inspected with it; 1 other recorded name; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Inspection history · 28
24 June 2026
Annual Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 8413744
3 June 2025
COI Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 8135813
13 August 2024
Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 7976268
3 June 2024
Annual Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 7921461
23 August 2023
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 7753573
28 July 2022
Periodic Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 7511971
1 July 2021
Annual Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 7247960
20 May 2020
Administrative Inspection · MTSA Verification · Initial Certification
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6967749
14 March 2019
Administrative Inspection
Administrative · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6643034
5 February 2012
Type not recorded
No type recorded · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 4240568
5 January 2012
Type not recorded
No type recorded · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 4219678
14 September 2011
Type not recorded
No type recorded · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 4145138
24 September 2009
Administration · MARPOL · Industry Initiated Exam · MTSA Verification · Deficiency Check · DAPI Audit
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 3604541
4 September 2008
Deficiency Check · Uninspected Other
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 3320297
21 May 2007
Deficiency Check
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 2937513
28 February 2007
Uninspected Other
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 2880580
1 February 2007
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 2866257
29 June 2006
Uninspected Other · Administrative Inspection · MTSA Verification
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 2695052
9 January 2006
Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2563224
29 December 2005
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2557645
15 September 2005
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2501400
3 August 2005
Type not recorded
No type recorded · MSD PEORIA · USCG Heartland District (CGD-H) · Activity 2509868
24 January 2005
Type not recorded
No type recorded · MSD PEORIA · USCG Heartland District (CGD-H) · Activity 2304979
30 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1986663
14 December 1999
Type not recorded
No type recorded · MSD PEORIA · USCG Heartland District (CGD-H) · Activity 435791
15 December 1998
Type not recorded
No type recorded · MSD PEORIA · USCG Heartland District (CGD-H) · Activity 423882
12 November 1997
Type not recorded
No type recorded · MSD PEORIA · USCG Heartland District (CGD-H) · Activity 409986
9 October 1997
Type not recorded
No type recorded · MSD PEORIA · USCG Heartland District (CGD-H) · Activity 408910
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 9 June 2020
Resolved
Provide a functioning remote shut off for the starboard fuel tank. The pull handle broke off of the cable during testing.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 9 June 2020
Resolution: Entirely new pull cable fitted to shut off.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 4 September 2008
Resolved
Properly guard the overhead, engineroom, exhaust fan.
Condition: Unknown
Due 4 October 2008
Resolved 20 October 2008
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 4 September 2008
Resolved
Blank off all open electrical breakers.
Condition: Unknown
Due 4 October 2008
Resolved 20 October 2008
Engineering › Fuel Oil Service System › Valve, Control
Issued 28 February 2007
Resolved
Properly secure the overhead fuel oil shut down cable for the stbd generator.
Condition: Unknown
Due 15 April 2007
Resolved 21 May 2007
Electrical › Electrical Distribution System (service) › Cable
Issued 28 February 2007
Resolved
Ensure all overhead electrical wires are supported with metal supports every 24 inches.
Condition: Unknown
Due 15 April 2007
Resolved 21 May 2007
Construction/Loadline › Hull › Stiffener
Issued 28 February 2007
Resolved
Repair fracture in the base of the stbd generator, inboard, support rail.
Condition: Unknown
Due 15 April 2007
Resolved 21 May 2007
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 28 February 2007
Resolved
Replace the broken breaker toggle handle on the stbd generator electrical switchboard box.
Condition: Unknown
Due 15 April 2007
Resolved 21 May 2007
Construction/Loadline › Structures › Manhole
Issued 28 February 2007
Resolved
Ensure the aft, main deck steering void, access plate is watertight.
Condition: Unknown
Due 15 April 2007
Resolved 21 May 2007
Navigation › Piloting/Steering › Marine Charts
Issued 28 February 2007
Resolved
Ensure the vessel has an updated navigational river chart.
Condition: Unknown
Due 15 April 2007
Resolved 21 May 2007
Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Fixed Piping System
Issued 28 February 2007
Resolved
Ensure the vessel has an installed bilge pump and piping system as per 33 CFR 155.410.
Condition: Unknown
Due 15 April 2007
Resolved 28 February 2007
Electrical › Electric Supply System (service) › Cable
Issued 28 February 2007
Resolved
Permanently install (electrically hard wire) the rose boxes, electric bilge pumps.
Condition: Unknown
Due 15 April 2007
Resolved 21 May 2007
Lifesaving › Lifebuoys › Stowage
Issued 28 February 2007
Resolved
Ensure life rings are immediately available and not bungeed to the vessel.
Condition: Unknown
Due 15 April 2007
Resolved 21 May 2007
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 29 June 2006
Resolved
Fixed Fire Dectection System was not installed properly and not operating.
Condition: Improper Installation
Due 29 July 2006
Resolved 5 July 2006
Resolution: Fixed fire detection system was properly repaired.
Fire Fighting › Semiportable Chemical-Foam Fire Extinguishers › Condition
Issued 29 June 2006
Resolved
Vessel did not have a fixed fire fighting system or a B-V extinguisher on board as required.
Condition: Improper Installation
Due 29 July 2006
Resolved 5 July 2006
Resolution: Vessel acquired a B-V extinguisher.
Fire Fighting › Remote Fuel Shutoff › General
Issued 29 June 2006
Resolved
Emergency shut-downs were in-operable.
Condition: Improper/Lack of Maintenance
Due 29 July 2006
Resolved 5 July 2006
Resolution: Emergency shut-downs were repaired.
Communications › Alarms/Indicators › General Alarm
Issued 29 June 2006
Resolved
General alarm in-operable.
Condition: Improper/Lack of Maintenance
Due 29 July 2006
Resolved 5 July 2006
Resolution: General alarm replaced by electrician.
Personnel › Training › Fire Fighting Basic
Issued 29 June 2006
Resolved
No documentation or practice of fire-fighting training for vessel crew members.
Condition: Unknown
Due 29 July 2006
Resolved 5 July 2006
Resolution: Vessel crew members trained by local FD, and properly logged.
Lifesaving
Issued 14 December 1999
Resolved
LIFE RING ON BRIDGE WING WAS FOUND TO BE IN POOR CONDITION. VSL HAS 4 LIFERINGS. LIFE RING TO EITHER BE REMOVED FROM SERVICE OR REPLACED.
Condition: Unknown
Due 14 January 2000
Resolved 11 May 2000
Lifesaving
Issued 14 December 1999
Resolved
REPLACE WORN HOSE CLAMPS ON STBD SKIN COOLER INTAKE.
Condition: Unknown
Due 14 January 2000
Resolved 11 May 2000
Documentation
Issued 15 December 1998
Resolved
ORIGINAL COD NOT ONBOARD.
Condition: Unknown
Due 15 January 1999
Resolved 5 May 1999
Fire Fighting
Issued 15 December 1998
Resolved
ONE DISCHARGED EXTINGUISHER.
Condition: Unknown
Due 15 January 1999
Resolved 5 May 1999
Documentation › Markings/Placards › Oil Discharge Placard
Issued 9 October 1997
Resolved
MARPOL PLACARD WAS NOT ON BOARD.
Condition: Unknown
Due 9 November 1997
Resolved 29 June 2006
Documentation › Manuals/Policy Documentation › Bridge Resource Management Policy/Procedures
Issued 9 October 1997
Resolved
NO LOCAL NOTICE TO MARINERS ON BOARD.
Condition: Unknown
Due 9 November 1997
Resolved 29 June 2006