MAURY USCG vessel records
← All vessels

CAPE ROMAIN

Built
1973
Last inspected
20 May 2025
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 20 May 2025
…with no type recorded13
Operational controls None recorded without a removal date
Years with a record 18 calendar years (1992–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDL7908
124720
Flag
UNITED STATES
Maury page id
psix-124720

Documentation record

Registered dimensions (L × B × D)61.1 ft × 21.7 ft × 9.2 ft
Registered tonnagegross 81 / net 65
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTERREBONNE SHIPBUILDING · HOUMA, LA, UNITED STATES · built 1973
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portWANDO, SC
Endorsements, as the file codes themcw_un
DocumentationValid · issued 15 November 2025 · expires 30 November 2026
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it65 - Simplified, Net Ton
81 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 31 inspections, each with its date, unit and type; 37 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 6 other vessels inspected with it; 1 other recorded name; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 6

Inspection history · 31

20 May 2025 Annual Inspection · Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8136933
28 May 2024 Drydock Exam · Internal Structural Exam · COI Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7917316
6 October 2023 Deficiency Check · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7804259
31 January 2023 Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7629388
30 September 2021 Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7329024
16 March 2021 Annual Inspection · Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7156928
10 August 2020 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7029224
7 January 2019 Administrative Inspection · Initial Certification · Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6606549
9 May 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6409855
6 October 2016 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6017848
17 May 2016 DAPI Audit · Administration · Industry Initiated Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5885160
10 June 2013 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 4616611
8 May 2013 Industry Initiated Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 4586174
8 May 2013 DAPI Audit
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 4586192
30 November 2011 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4200282
1 September 2011 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4139155
24 June 2011 DAPI Audit · Administration · Industry Initiated Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 4069771
6 January 2006 Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2562168
20 December 2004 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2263668
5 May 2004 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2063925
24 January 2001 Uninspected Towing Vessel
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1057116
24 January 2001 Uninspected Towing Vessel
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1064273
28 January 1999 Uninspected Towing Vessel
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1131091
16 December 1996 Uninspected Towing Vessel
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1098535
3 October 1996 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 219956
18 August 1995 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 723666
11 July 1995 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 63150
3 July 1995 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 753266
2 July 1995 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 209401
29 June 1993 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 144062
3 September 1992 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 77346

Deficiency record · 37

07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 20 May 2025 Resolved
The portable fire pump must be self-priming and power-driven, with: (1) A minimum capacity of at least 300 LPM (80 gpm) at a discharge gauge pressure of not less than 414 kPa (60 psi), measured at the pump discharge. Fire pump would not maintain 60 psi
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 June 2025
Resolved 28 May 2025
Resolution: Fire pump was tuned up and maintains 60 psi.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 May 2025 Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Temporary splice was made in oil transfer pump wiring
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 June 2025
Resolved 28 May 2025
Resolution: splice was removed and plug end installed
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 May 2025 Resolved
Electrical components that pose an electrical hazard must be in an enclosure. Outlets missing cover plates in the engineroom
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 June 2025
Resolved 28 May 2025
Resolution: cover plates installed
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 20 May 2025 Resolved
A towing vessel must carry a combination of day and night visual distress signals indicated in Table 141.370 of § 141.370 for specified areas where the vessel operates. Missing two day signals.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 June 2025
Resolved 28 May 2025
Resolution: propper amount of distriss signals placed in service.
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 20 May 2025 Resolved
Emergency lighting must be provided for all internal crew working and living areas. Emergency lighting sources must provide for sufficient illumination under emergency conditions to facilitate egress from each space and must be either:Non-electric, phosphorescent adhesive lighting strips that are installed along escape routes and sufficiently visible to enable egress with no power. Phosphorescent strips did not light.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 June 2025
Resolved 28 May 2025
Resolution: New phosphorescent adhesive lighting strips with exit markings installed.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 28 May 2024 Resolved
Each towing vessel must be equipped with a means to detect smoke in the berthing spaces and lounges that alerts individuals in those spaces. Detection systems or individual detectors must be kept operational at all times when the crew is onboard the towing vessel. Smoke detector did not have a battery to allow proper function.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 August 2024
Resolved 13 August 2024
Resolution: Email from vessel rep stated that a new battery was installed into the detector.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 28 May 2024 Resolved
An exposed hazard such as gears and rotating machinery, must be protected by a cover, guard or rail. Belt and pulley system for air compressors need guard to protect the moving equipment.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 13 August 2024
Resolution: Vessel rep sent pic of a newly installed, expanded metal guard on the compressor pulleys
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 October 2023 Resolved
Propulsion machinery, including main engines, reduction gears, shafting, bearings, and electrical equipment and systems, must be maintained to ensure proper operation. The STBD main had an exhaust leak from the inboard manifold needing repair.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 November 2023
Resolved 23 October 2023
Resolution: RCVD video evidence of completed repair w/eng running, from the master.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 6 October 2023 Resolved
Any person who is found qualified under the requirements set forth in this part is issued an appropriate license or certificate of registry valid for a term of 5 years from date of issuance. The master's license was expired at the time of inspection.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 10 October 2023
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 31 January 2023 Resolved
(b) A towing vessel must be maintained and operated so the watertight integrity and stability of the vessel are not compromised. The watertight door on the forward bulkhead, had a completely wasted bottom flange, causing the gasket to not maintain watertight integrity.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 February 2023
Resolution: The door flange was repaired and checked for watertightness during follow up visit.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 31 January 2023 Resolved
A sufficient amount of lined commercial fire hose 15 meters (50 feet) in length, at least 40 mm (1.5 inches) in diameter and immediately available to attach to it so that a stream of water will reach any part of the vessel. The hose connection for attachement to the portable pump, was missing, preventing the hose from use.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 February 2023
Resolution: pump was set up and run during follow up visit.
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 31 January 2023 Resolved
Sufficient lighting suitable for the marine environment must be provided within crew working and living areas. Lighting throughout the accomodations had no covers, and exposed glass/flourescent bulbs.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 February 2023
Resolution: Lights replaced throughout vessel with LED fixtures.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 17 August 2021 Resolved
Closure devices must be provided for deckhouse or hull penetrations, which open to the exterior of the vessel and which may allow water to enter the vessel. These devices must be suitable for the expected route. Identified hole the the engine room stbd deck overhead.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 August 2021
Resolved 30 September 2021
Resolution: Repair was conducted on the hatch.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 17 August 2021 Resolved
Immersion suits stowage positions must be marked with either the words “IMMERSION SUITS” or “ANTI-EXPOSURE SUITS” as appropriate, or with the appropriate symbol from IMO Resolution A.760(18). Immersion suit stowage locations not labeled.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 September 2021
Resolved 30 September 2021
Resolution: Imersion suit location was marked.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 17 August 2021 Resolved
Each immersion suit or anti-exposure suit must be marked in such a way as to identify the person or vessel to which it belongs. Immersion suits were not marked.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 September 2021
Resolved 30 September 2021
Resolution: Vessel name was placed on imersion suits
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 17 August 2021 Resolved
Each immersion suit or anti-exposure suit must have a lifejacket light approved under approval series 161.112 securely attached to the front shoulder area of the immersion suit or anti-exposure suit. No light was present on immersion suits.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 September 2021
Resolved 30 September 2021
Resolution: Added approved water light
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 August 2021 Resolved
The master must ensure that all lifesaving equipment is properly maintained and ready for use at all times. Approval on Type 1 light requires annual battery replacement.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 September 2021
Resolved 30 September 2021
Resolution: Vessel replaced waterlights that do not require annual servicing.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 17 August 2021 Resolved
Pressure vessel relief valves need to be tested Twice every 5 years, with no more than 3. Relief valves must be tested in accordance with §143.245. Relief valve testing was not conducted.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 September 2021
Resolved 30 September 2021
Resolution: vessel replaced the relief valves
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 17 August 2021 Resolved
A towing vessel must carry adequate and up-to-date charts, maps, and nautical publications for the intended voyage. Vessel needs updated charts and Nav Rules (COLREGS) publications on board.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 September 2021
Resolved 30 September 2021
Resolution: Vessel placed inservice updated charts and nav rules
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 August 2021 Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Mess deck was fitted with a daisy chained temporary wire.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 September 2021
Resolved 30 September 2021
Resolution: Temporay wire installation was removed.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 17 August 2021 Resolved
Crewmember training required by this section must be conducted as soon as practicable, but not later than 5 days after employment. No crew training was recorded.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 September 2021
Resolved 30 September 2021
Resolution: Crew member oreientation was conducted.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 17 August 2021 Resolved
Refresher training must be repeated annually and may be conducted over time in modules covering specific topics. No abandon ship refresher training was recorded.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 September 2021
Resolved 30 September 2021
Resolution: Crew conducted required annual refresher training
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 17 August 2021 Resolved
Each vessel must carry a certificate with a valid endorsement while subject to the Bridge-to-Bridge Act. All other bridge-to-bridge stations will be inspected from time to time. Bridge to Bridge certificate call sign was incorrectly reflected on the certificate.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 September 2021
Resolved 30 September 2021
Resolution: Bridge to bridge certificate was corrected.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 16 March 2021 Resolved
The owner or managing operator must implement procedures for reporting unsafe conditions and must have records of the activities conducted under this section. Health and Safety Plan was missing vital information and updates.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 September 2021
Resolved 30 September 2021
Resolution: Health and safety plan was corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 10 September 2020 Resolved
There must be an installed or portable bilge pump for emergency dewatering. Any portable pump must have sufficient hose length and pumping capability. All installed bilge piping must have a check/foot valve in each bilge suction that prevents unintended backflooding through bilge piping. Prove proper operation of bile suction in all spaces required.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 September 2020
Resolved 17 September 2020
Resolution: Conducted satisfactory test of bilge pump
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 10 September 2020 Resolved
a) Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention. The following alarms must be provided: (5) High bilge levels; Prove proper operation of bilge alarm and remove any switches that could isolate alarm.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 September 2020
Resolved 17 September 2020
Resolution: Removed switch from panel and operationally tested with satisfactory results.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 10 September 2020 Resolved
Where practicable and except as provided in §144.515, each space where crew may be quartered or normally employed must have at least two means of escape. Arrangements on an existing vessel may be retained if it is impracticable or unreasonable to provide two means of escape. Ensure escape from state room is not blocked and ensure door is weather tight.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 September 2020
Resolved 17 September 2020
Resolution: Vessel removed the foam sealing the doors and added rubber gaskets to the door. Doors operate freely and are weather tight.
08 - Alarms › N/A - No Subsystem › Steering gear alarm
Issued 10 September 2020 Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention. The following alarms must be provided: (6) Low hydraulic steering fluid levels, if applicable
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 October 2020
Resolved 20 October 2020
Resolution: Tested alarm and found satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 10 September 2020 Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Port Generator Prime Mover has exhaust leak. Secure leak.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 October 2020
Resolved 17 September 2020
Resolution: Vessel removed and replaced the leaking exhaust flange gaskets.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 September 2020 Resolved
At least two lifebuoys on a towing vessel greater than 26 feet must be fitted with a floating electric water light approved under approval series 161.010 or 161.110. Light has battery that caused unit to sink when tested, ensure recommended battery from manufacture is used.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 September 2020
Resolved 17 September 2020
Resolution: Vessel replaced the floating electric water light and placed in proper service.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 10 September 2020 Resolved
Each towing vessel must have either a self-priming, power-driven, fixed fire pump, a fire main, and hoses and nozzles in accordance with paragraphs (a) through (d) of this section; or a portable pump, and hoses and nozzles, in accordance with paragraphs (e) and (f) of this section. (3) A nozzle made of corrosion-resistant material capable of providing a solid stream and a spray pattern.Provide Proper Fire nozzle as required.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 September 2020
Resolved 17 September 2020
Resolution: Vessel replaced the inopperable fire hose nozzle.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Safety and environment policy
Issued 10 September 2020 Resolved
No later than July 22, 2019, the owner or managing operator must implement a health and safety plan. The health and safety plan must document compliance with this part and include recordkeeping procedures. (b) The owner, managing operator, or master must ensure that all persons on board a towing vessel comply with the health and safety plan. Provide Health and safety plan complying with the requirements in 46 CFR 140.505
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 October 2020
Resolved 17 September 2020
Resolution: Received satisfactory health and safety plan.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 10 September 2020 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 October 2020
Resolved 20 October 2020
Resolution: Received valid FCC documentation.
01 - Certificates & Documentation › 012 - Crew Certificates › Cert for personnel on survival craft & rescue boat
Issued 10 September 2020 Resolved
Lifeboatman-limited. Every person assigned duties onboard a vessel that is not required to carry lifeboats and is required to employ a lifeboatman must hold an endorsement as either lifeboatman or lifeboatman-limited. Persons serving on vessels subject to the STCW Convention must also hold an STCW endorsement in proficiency in survival craft and rescue boats other than lifeboats and fast rescue boats—limited (PSC—limited). Ensure 01 person onboard at all times has endorsement for Lifeboatmen-limmited.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 October 2020
Resolved 31 January 2023
Resolution: Vessel has licensed master, which is responsible for training of crew on all equipment.
09 - Working and Living Conditions › 092 - Working Conditions › Fitness for duty - intoxication
Issued 10 September 2020 Resolved
When a marine employer determines that a casualty or incident is, or is likely to become, an SMI, the marine employer must ensure that the following alcohol and drug testing is conducted: The alcohol testing of each individual must be conducted within 2 hours of when the SMI occurred, unless precluded by safety concerns directly related to the incident. Provide testing that meets DOT approval.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 October 2020
Resolved 17 September 2020
Resolution: Vessel recieved a letter from manufacuer that the strips meet the DOT testing requirements.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 September 2020 Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Ensure Temperature pressure relief valve for hot water heater is operational and no modifications are installed. Pipe plug was installed blocking the relief valve.
Action required: 10 - Deficiency Rectified
Due 10 September 2020
Resolved 10 September 2020
Resolution: Vessel removed pipe plug from Temperature pressure relief valve.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 24 July 2019 Resolved
Each towing vessel must have either a self priming, power driven, fixed fire pump, a fire main, and hoses and nozzles in accordance with paragraphs (a) through (d). Vessel must provide one the options above.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 August 2019
Resolved 13 August 2019
Resolution: Portable Fire Pump was successfully tested.

Recorded names · 1

MITZIE HUGHES (2004). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.