Records from 2016 to 2024. Most recent: inspection, 26 October 2024.
Inspection history · 7
26 October 2024
PSC B
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8024974
18 October 2024
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8021241
27 October 2020
PSC B · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7084184
21 August 2016
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5978779
18 August 2016
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5975889
18 August 2016
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6027214
28 July 2016
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5938102
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 28 October 2020
Resolved
74SOLAS(14)II-1/43.2
The electrical power available shall be sufficient to supply all those services that are essential for safety in an emergency. Emergency lighting circuit breakers on the bridge were left in the open position.
Condition: Design Flaw
Action required: 10 - Deficiency Rectified
Resolved 28 October 2020
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Emergency preparedness
Issued 28 October 2020
Resolved
74SOLAS(14)IX/3.1
ISM COD 5.1.5
The company should clearly define and document the masters responsibility with regards to periodically reviewing the safety management system and reporting its deficiencies to the shore based management. The master is not reporting deficiencies to shore based management.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 18 November 2020
Resolution: See Class Report for further details.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Masters responsibility and authority
Issued 28 October 2020
Resolved
74SOLAS(14)IX/13.1
ISM CODE 5.1.4
The company should clearly define an ddocument the masters responsibility with regards to verifying that specified requirements are observed. The master is not ensuring the crew is following established emergency procedures.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 18 November 2020
Resolution: See Class Report for further details.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 28 October 2020
Resolved
74SOLAS(14)II-1/43.2
The electrical power available shall be sufficient to supply all those services that are essential for safety in an emergency. Multiple emergency light stations were not operational.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 November 2020
Resolution: See Class Report for further details.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Insulation wetted through (oil)
Issued 27 October 2020
Resolved
SOLAS 74(14) II-2/ 4.1.1
Means shall be provided to control leaks of flammable liquids.PSCO observed oil and fuel soaked lagging in purifier compartment (F/O and L/O purifier piping system) and several oil and fuel soaked lagging was observed on the M/E fuel and oil system lines.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 27 October 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 October 2020
Resolved
SOLAS 74(14)II-2/4.2.2
In a ship in which oil fuel is used the arrangements for the storage distribution and utilization of the oil fuel shall be such as to ensure the safety of the ship and persons on board.Crew was using unapproved receptable (plastic container) to collect fuel emitted from M/E and generators.
Condition: Design Flaw
Action required: 10 - Deficiency Rectified
Resolved 27 October 2020
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 27 October 2020
Resolved
74SOLAS(14)II-2/14.2.1.1.1
The following fire protection systems shall be kept in good order... Structural fire protection including fire resistant divisions, and protection of openings and peptrations in these divisions. Multiple class A fire Doors in stairwell were not self latching.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 27 October 2020