MAURY USCG vessel records Sign in
← All vessels

G.L. 603

G.L. 603 is a 2015 industrial vessel. The Coast Guard has recorded 9 inspections since 2014, most recently in December 2018, along with 2 deficiencies and 2 casualty investigations between 2015 and 2016.

Records from 2014 to 2018. Most recent: inspection, 13 December 2018.

Built
2015
Last inspected
13 December 2018
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

1277395
Flag
UNITED STATES
368066130
Maury page id
psix-1277395

Inspections, by type

…with no type recorded3
Years with a record 5 calendar years (2014–2018)
The 9 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 8 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Documentation record

Registered dimensions (L × B × D)284.0 ft × 54.0 ft × 25.5 ft
Registered tonnagegross 3,259 / net 1,260
ITC dimensions (L × B × D)284.0 ft × 54.0 ft × 25.5 ft
ITC tonnagegross 3,259 / net 1,260
BuilderCORN ISLAND SHIPYARD INC · GRANDVIEW, IN, UNITED STATES · built 2015
Hull materialSteel
PropulsionNot recorded
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW YORK, NY
Trade endorsementsCoastwise, charter, Registry
DocumentationValid · issued 16 June 2026 · expires 28 February 2027
Service, as the file records itIndustrial Vessel
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it3259 - Convention (Subpart B), Gross Ton
1260 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDK5569MMSI 368066130 · active · voluntarily equipped · granted 14 November 2018, expires 14 November 2028
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 6

Inspection history · 9

13 December 2018 Administrative Inspection
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6596964
26 March 2018 Drydock Exam · Annual Inspection · Internal Structural Exam · Administrative Inspection · MARPOL Annex I Examination
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6378715
2 November 2017 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 6299459
18 May 2017 In-Service Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6149119
5 April 2017 MARPOL Annex I Examination · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6118173
19 February 2016 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5832571
14 January 2016 MARPOL Annex I Examination · Administrative Inspection · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5808221
7 June 2015 Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 5156719
1 July 2014 Internal Structural Exam · Construction Oversight · Hull Examination · Administrative Inspection · Initial Certification
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4907154

Deficiency record · 2

Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 5 April 2017 Resolved
Cut- off valve for fuel oil tank is frozen in open position; required replacement
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 April 2017
Resolved 5 April 2017
Engineering › Fuel Oil Service System › Valve
Issued 14 January 2016 Resolved
fuel cut out valve frozen open; repaired.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 15 January 2016
Resolved 14 January 2016
Resolution: corrected

Casualty record · 2

7 June 2015Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 5156719
19 February 2016Routine · role: Involved in a Marine Casualty · activity 5832571
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

2014 (2015–2016). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.