Records from 2014 to 2025. Most recent: inspection, 26 August 2025.
Documentation record
Registered dimensions (L × B × D)403.9 ft × 76.7 ft × 27.0 ft
Registered tonnagegross 6,695 / net 4,011
ITC dimensions (L × B × D)403.9 ft × 76.7 ft × 27.0 ft
ITC tonnagegross 6,695 / net 4,011
BuilderVIGOR INDUSTRIAL LLC · PORTLAND, OR, UNITED STATES · built 2016
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portPORTLAND, OR
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 18 February 2026 · expires 31 March 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it4011 - Convention (Subpart B), Net Ton
6695 - Convention (Subpart B), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 22
26 August 2025
COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8208602
6 August 2025
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8193191
23 July 2025
Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8204179
12 September 2023
Deficiency Check · MTSA Verification · Periodic Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7789976
1 July 2023
Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7727877
4 May 2023
Damage Survey
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7680746
2 December 2022
Administrative Inspection · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7603976
8 November 2022
In-Service Inspection · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7591442
24 August 2021
MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7294927
13 August 2020
Internal Structural Exam · COI Inspection · Drydock Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7031623
4 May 2020
Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6948240
28 January 2020
Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6897897
10 December 2019
Bulk Liquid Transfer Monitor
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6871383
12 February 2019
MTSA Verification · Periodic Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6624638
2 March 2018
MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6364747
23 February 2017
MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6093566
5 January 2017
In-Service Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6066185
31 August 2016
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5986226
11 June 2016
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5903984
19 May 2016
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5881056
11 May 2016
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5876081
22 July 2014
Internal Structural Exam · Cargo Tank Internal · MTSA/ISPS Verification · COI Inspection · Hull Examination · Construction Oversight
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4979206
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 26 August 2025
No resolution recorded
Vessel has soft inset on port side, forward rake. Repairs must be made at next scheduled drydock.
Action required: 705 - Other - as specified
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 26 August 2025
No resolution recorded
Vessel has soft inset in port aft corner rake. Repairs must be made at next scheduled drydock.
Action required: 705 - Other - as specified
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 18 August 2025
Resolved
Testing, operations, or annual inspection of the PV valves and vapor control system was not observed.
Vessel must provide a test/inspection plan and valid certifications to the local [name withheld] must be completed prior to cargo operations.
33CFR156.170(f)(3)
Action required: 705 - Other - as specified
Resolved 21 August 2025
Resolution: Will be completed during COI renewal exam.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other cargo/timber/deck/construction
Issued 18 August 2025
Resolved
Observed possible cargo intrusion into voids from Cargo Tank #5 (identified via IG system or CT). Similar issue observed in Cargo Tank #2 (associated with welds).
Vessel must submit a repair plan to the local [name withheld] approved repairs followed by NDT. Vessel is not authorized to conduct operations until resolution of this item.
46CFR30.01-10
Action required: 705 - Other - as specified
Resolved 21 August 2025
Resolution: Verified a leak in the tube and shell heat exchanger of the IG system let to the entry of oil in #2 void.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 September 2023
Resolved
Electric installations and electric equipment must be inspected at the inspection for certification and periodic inspection to determine mechanical and electrical condition and performance. Vessel was unable to demonstrate the over-speed protection on the #1 generator. Demonstrate over speed protection test procedures to the satisfaction of the attending marine inspector. 46 CFR 110.30-5
Action required: 705 - Other - as specified
Resolved 16 September 2023
Resolution: Prior to commercial operations. Item was tested and found satisfactory
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 12 September 2023
Resolved
Each inflatable liferaft must be approved under approval series 160.151 and be equipped with a SOLAS A pack. Vessel had a NON-SOLAS inflatable liferaft. Replace liferaft with a SOLAS A approved liferaft to the satisfaction of the attending marine inspector.
Action required: 705 - Other - as specified
Resolved 21 September 2023
Resolution: Resolved to leave Special Note to rectify prior to next drydock credit.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 November 2022
Resolved
All machinery associated with cargo loading, unloading, or cooling shall be capable of being shutdown from a remote location. tow of the three ESD for cargo tranfer wher inoperable and open with wires exposed.
Action required: 703 - Prior to bunkering operations
Due 14 November 2022
Resolved 14 November 2022
Resolution: Replaced ESD with New ones
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 February 2019
Resolved
Electrial PNL in IG room providing power to transformer requires ground detection lights.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 15 March 2019
Resolved 5 March 2019
Resolution: Electrician tested all reverse power relays and installed fault detector in IG Room.
Supporting documentation is in Docs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 February 2019
Resolved
Reverse-power and reverse current trips. Each generator arranged for parallel operation must have reverse-power or reverse current trips.
Action required: 705 - Other - as specified
Due 12 March 2019
Resolved 5 March 2019
Resolution: Electrician tested all reverse power relays and installed fault detector in IG Room.
Supporting documentation is in Docs.
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 2 March 2018
Resolved
There must be ground detection for power or lighting distribution systems. Provide ground detection for 220V system.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 June 2018
Resolved 5 April 2018