Records from 2016 to 2026. Most recent: inspection, 27 March 2026.
Documentation record
Registered dimensions (L × B × D)174.4 ft × 31.9 ft × 14.0 ft
Registered tonnagegross 95 / net 65
ITC dimensions (L × B × D)174.4 ft × 31.9 ft × 14.0 ft
ITC tonnagegross 496 / net 148
BuilderBREAUX BROTHERS ENT INC · LOREAUVILLE, LA, UNITED STATES · built 2015
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portGALLIANO, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 22 July 2026 · expires 31 August 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it496 - Convention (Subpart B), Gross Ton
95 - Regulatory (Subpart C or D), Gross Ton
148 - Convention (Subpart B), Net Ton
65 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 21
27 March 2026
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8322884
3 June 2025
COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8137727
27 March 2025
Examination of Repairs · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8100306
11 July 2024
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7954352
30 August 2023
Administrative Inspection · In-Service Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7778412
30 August 2023
Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7781582
11 July 2023
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7739472
21 June 2023
Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7715878
4 October 2022
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7571401
9 June 2022
In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7478057
18 October 2021
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7333715
28 July 2021
Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7268634
13 April 2021
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7258304
11 December 2020
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7110461
10 July 2020
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7002512
18 September 2019
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6813963
31 July 2019
Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6768313
9 October 2018
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6557267
13 October 2017
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6287253
13 July 2017
Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6206885
15 September 2016
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6001847
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 3 June 2025
Resolved
On a vessel of at least 26 feet in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each listed normally unmanned space. Bilge alarm was not audible in the bridge.
46 CFR 182.530(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 June 2025
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 3 June 2025
Resolved
Standby vessels must have at least the following requirement: a fire monitor with a minimum flow rate of at least 500 gallons per minute. The installed fire monitors were inoperable.
33 CFR 143.405(a)(12)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 9 June 2026
Resolution: Monitors and pumps removed. Rep and vsl requested removal of stand-by endorsement, will reflect next time COI is issued.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 11 July 2024
Resolved
Where pressure-indicating gages are used, they shall be chosen to be compatible with the pressure to be indicated. In no case shall the upper range of the gage be less than 1.2 times nor more than 2 times the pressure which the relieving device is set to function. Pressure gauge had a relief valve set to go off at 198 psi, max range of pressure gauge was 160 and did not fall within 1.2 - 2 times value of the relief valve.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 11 July 2024
Resolution: Crew replaced unsatisfactory pressure gauges with two (2) pressure gauges that read up to 300 psi.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 18 October 2021
Resolved
Vessel must undergo an inspection within the 3 months before or after each anniversary date. Vessel was found operating outside of inspection date (last day of window for inspection was 10 OCT 2021). Vessel completed annual inspection on 18 OCT 2021
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 18 October 2021
Resolution: Annual Inspection completed 18OCT2021
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 18 October 2021
Resolved
Ring Life Buoy must be marked with Type II retroreflective tape. 2 life buoys were found with worn tape. Replaced on spot.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 18 October 2021
Resolution: New SOLAS Type II Retro tape placed onto life rings
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 September 2019
Resolved
03 Ring Lifebouys required maintanace. VSL rep will replace all 03 ring lifebouys.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 September 2019
Resolved 19 September 2019
Resolution: VSL purchased 03 new lifering buoys and stenciled them with vsl name and apllied reflective tape.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 15 September 2016
Resolved
An emergency light on the stbd side of the engine room was out and did not come back on when the light buld was replaced, it still did not work.
Action required: 705 - Other - as specified
Resolved 15 September 2016
Resolution: An electrician was brought on board and replaced a faulty fuse.