Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
583 - Convention (Subpart B), Gross Ton
163 - Regulatory (Subpart C or D), Gross Ton
175 - Convention (Subpart B), Net Ton
111 - Regulatory (Subpart C or D), Net Ton
Maury page id
psix-133185
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1972 to
2026, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
The Coast Guard recorded this vessel and the following in the same
inspection activity — normally a tug and the barges in its tow. Only barges and towing
vessels are in this archive, so any other vessel type in the same activity does not
appear here: these lists are a floor, not a complete manifest.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 16 April 2025Resolved
There mst be an installed or portable bilge pump for emergency dewatering. Bigle system down for maintenance.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 May 2025
Resolved 28 May 2025
Resolution: Attended vesssel and tested system. Test sat.
Where practicable and except as provided in 144.515, each space where crew may be quarted or normally employed must have at least two means of escape. Vessel's forward escape hatch was seized.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 16 April 2025
Resolved 16 April 2025
Resolution: Performed maintenance.
"The master, owner, operator, agent, or person in charge of a vessel bound for a port or place in the United States, unless specifically exempted by § 151.2015 of this subpart, must ensure the maintenance of written or digital records that include the information required to be reported by § 151.2060 of this subpart and the sediment information in paragraph (a)(1) of this section."
"Information on ballast water tanks that are to be discharged into the waters of the United States or to a reception facility. Include the following for each tank discharged:(i) The numerical designation, type and capacity of the ballast tank.(ii) The source of the ballast water. This includes date(s), location(s), and volume(s). If a tank has undergone ballast water exchange, provide the loading port of the ballast water that was discharged during the exchange.(iii) The date(s), starting location(s), ending location(s), volume(s), and method(s) of ballast water management.(iv) The date(s), location(s), and volume(s) of any ballast water discharged into the waters of the United States or to a reception facility"
Ballast water records onboard the vessel do not show any location where the vessel discharged ballast water.
Company shall ensure that this vessel and all others in the fleet comply with ballast water recordkeeping requirements, specifically ensuring the documentation of: "The date(s), location(s), and volume(s) of any ballast water discharged into the waters of the United States or to a reception facility"
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 September 2022
Resolved 17 September 2022
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 15 July 2021Resolved
A towing vessel must be equipped with a fixed fire-extinguishing system installed to protect the engine room. Fixed fire-extinguishing system was in unserviceable condition due to deteriorated supply hoses, corroded control heads and corrosion on the pressure shut down switch. Servicing company needs to re-certify the system IAW 46 CFR 142.240 and repairs are to be verified by a Marine Inspector.
Action required: 60 - Rectify deficiencies prior to movement
Due 15 August 2021
Resolved 16 July 2021
Resolution: Servicing company attended the vessel and recertified the fixed fire fighting system in the presence of a marine inspector.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 15 July 2021Resolved
Alarms must be visible and audible at the operating station. Audible high bilge level alarm did not sound at the operating station.
Action required: 17 - Rectify deficiencies prior to departure
Due 15 August 2021
Resolved 16 July 2021
Resolution: Vessel provided video of proper operation of the audible alarm from the operating station.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 15 July 2021Resolved
The master must ensure that all lifesaving equipment is properly maintained and ready for use at all times. 2 lifebuoys on the starboard side and 1 on the port side were in an unserviceable condition.
Action required: 17 - Rectify deficiencies prior to departure
Due 15 August 2021
Resolved 16 July 2021
Resolution: Photos of new lifebouys installed on the vessel were provided.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 15 July 2021Resolved
Each towing vessel must be maintained and operated so as to minimize fire hazards and to ensure the following: all bilges are kept free from accumulation of flammable materials. Inspector observed lube oil accumulating in the bilges.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 August 2021
Resolved 13 August 2021
Resolution: Oil accumulation has been removed and bilges cleaned.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 15 July 2021Resolved
Emergency lighting sources must provide for sufficient illumination under emergency conditions to facilitate egress from each space. Inspector observed inadequate emergency lighting in the forward escape and forward machinery space. Additional emergency lights need to be added. In addition, emergency lights in the pilothouse stairwell and machinery space need bulb replacement.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 August 2021
Resolved 13 August 2021
Resolution: E-lighting added to forward escape and machinery space. Extinguished lighting replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 July 2021Resolved
Towing machinery used to connect the towing vessel to the tow must be suitable for its intended service. Significant corrosion and deterioration was noted on the assist winch between the main drum and brake rotor. Vessel must submit a plan of repairs prior to operating the winch.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 July 2021
Resolved 25 August 2021
Resolution: Vessel will address repair plan during next drydock. Added special note.