MAURY USCG vessel records
← All vessels

PONO

Built
1993
Last inspected
17 June 2026
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 17 June 2026
…with no type recorded12
Operational controls None recorded without a removal date
Years with a record 21 calendar years (1994–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WCB4095
392995
Flag
UNITED STATES
Maury page id
psix-392995

Documentation record

Registered dimensions (L × B × D)75.3 ft × 28.7 ft × 13.3 ft
Registered tonnagegross 147 / net 100
ITC dimensions (L × B × D)75.3 ft × 28.7 ft × 13.3 ft
ITC tonnagegross 171 / net 51
BuilderFASHION BLACKSMITH · CRESCENT CITY CA: COOS BAY, OR, UNITED STATES · built 1993
Hull materialSteel
PropulsionDiesel
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portPORTLAND, OR
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 6 May 2026 · expires 31 May 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it265 - Dead Weight, Ton
171 - Convention (Subpart B), Gross Ton
147 - Regulatory (Subpart C or D), Gross Ton
51 - Convention (Subpart B), Net Ton
100 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 29 inspections, each with its date, unit and type; 21 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 9 other vessels inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 9

Inspection history · 29

17 June 2026 Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8204099
5 June 2025 Vessel Attendance · Deficiency Check · COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8037515
16 April 2025 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8076555
25 February 2025 Internal Structural Exam · Drydock Extension
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8037537
30 July 2024 Administrative Inspection · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7733983
7 June 2023 Deficiency Check · Annual Inspection · Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7607013
1 August 2022 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7522572
2 June 2022 Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7457664
24 August 2021 Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7295632
7 December 2020 In-Service Inspection · Examination of Repairs
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7107600
5 June 2020 Deficiency Check · Initial Certification · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6957000
4 November 2019 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6832960
8 February 2012 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4243558
22 March 2010 Administration
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3700683
17 March 2010 Industry Initiated Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3747792
14 October 2009 Deficiency Check · MTSA Verification
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3655657
3 May 2008 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3198164
5 April 2007 Type not recorded
No type recorded · USCGC GALVESTON ISLAND (WPB 1349) · USCG Oceania District (CGD-O) · Activity 2934146
5 April 2007 Type not recorded
No type recorded · USCGC GALVESTON ISLAND (WPB 1349) · USCG Oceania District (CGD-O) · Activity 2998564
31 May 2006 MTSA Verification · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2666840
28 June 2004 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2162167
11 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1963215
22 October 2000 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 39536
25 January 2000 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 89271
7 March 1998 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 51531
11 June 1997 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 74066
11 April 1995 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 752738
30 March 1995 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 204575
24 August 1994 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 369901

Deficiency record · 21

11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 5 June 2025 Resolved
Each towing vessel operating in oceans and coastwise service must have a line throwing appliance approved under approval series 160.040. The line throwing appliance must have an auxiliary line that is at least 450 meters (1,500 feet) long; as a breaking strength of at least 40 kilonewtons (9,000 pounds-force); and is, if synthetic, of a dark color or certified by the manufacturer to be resistant to deterioration from ultraviolet light. MI observed that vessel did not have an auxilary line onboard. 46 CFR 141.385(b)(2)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2025
Resolved 14 July 2025
Resolution: MI received picture of the auxilary line via email.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 5 June 2025 Resolved
Towing vessels must be equipped with the following equipment, as applicable to the area of operation: Search light, controllable from the vessel's operating station and capable of illuminating objects at a distance of at least two times the length of the tow. MI observed that aft searchlight was inoperable. 46 CFR 140.725
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2025
Resolved 12 June 2025
Resolution: Received satisfactory pictures of repaired aft searchlight.
10 - Safety of Navigation › N/A - No Subsystem › Record of drills and steering gear tests
Issued 5 June 2025 Resolved
The following list of items must be recorded in the TVR, official logbook, or in accordance with the TSMS applicable to the vessel: Record of drills and instruction. MI observed the vessel's electronic log was not updated from the switch over from written logbook. 46 CFR 140.915
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2025
Resolved 12 June 2025
Resolution: Received satisfactory pictures of updated log entries on electronic logbook.
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 30 July 2024 Resolved
Each towing vessel operating in coastwise service must have a line throwing appliance approved under 46. CFR 160.040. Vessel missing three of the four required line throwing appliances.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 August 2024
Resolved 12 August 2024
Resolution: Vessel obtained throwing lines.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 30 July 2024 Resolved
Piping and machinery components that exceed 428 degrees Fahrenheit, including turbochargers, must be insulated. Vessels main engines are missing insulation in the vicinity of the turbochargers.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 August 2024
Resolved 12 August 2024
Resolution: Insulation installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 June 2023 Resolved
The master must ensure that all lifesaving equipment is properly maintained and ready for use at all times. Vessel did not have the required number of life jackets (08) and immersion suits (08) on board, and some of the life jackets were missing lights/whistles.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 June 2023
Resolved 1 July 2023
Resolution: Vessel submitted order receipt for missing lifesaving appliances.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 7 June 2023 Resolved
Each towing vessel operating on coastwise routes must have a means to take blood pressure readings, splint broken bones, and apply large bandages for serious wounds. Vessel's first aid kit was missing the required elements and had expired items.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 June 2023
Resolved 1 July 2023
Resolution: Vessel replaced first aid kit items.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 7 June 2023 Resolved
The master must ensure that all lifesaving equipment is properly maintained and ready for use at all times. The vessels ring buoys on the port and starboard bridge wings were deteriorated and need to be replaced.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 7 June 2023
Resolved 7 June 2023
Resolution: Vessel replaced life rings with new approved ones.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 2 June 2022 Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Electrical cables on the bulkhead within the lazarette were found to be melted (insulation damaged/exposed wires).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 July 2022
Resolved 5 August 2022
Resolution: The loose wires in the lazarette have been repaired and are now contained in a junction box.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 2 June 2022 Resolved
All installed bilge piping must have a check/foot valve in each bilge suction that prevents unintended backflooding through the bilge piping. Bilge suction foot within the lazarette does not have an installed back-flooding preventer valve (i.e. check valve).
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 July 2022
Resolved 5 August 2022
Resolution: The bilge suction in the lazarette now has an installed suction strainer and check valve.
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 2 June 2022 Resolved
Each towing vessel operating in oceans and coastwise service must have a line throwing appliance approved under approval series 160.040. Inspector found that the operator did not have onboard the required four charges, four projectiles, and four pre-coiled service lines required by 46 CFR 160.040.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 July 2022
Resolved 31 August 2022
Resolution: Operator sent a photo of the line launcher with 4 charges onboard the vessel.
10 - Safety of Navigation › N/A - No Subsystem › Bridge Navigation Watch Alarm System (BNWAS)
Issued 24 August 2021 Resolved
A towing vessel with overnight accommodations and alternating watches (shift work), when pulling, pushing or hauling alongside one or more barges, must have a pilothouse alerter system to detect when its master or mate (pilot) becomes incapacitated. Inspector found that a pilothouse alerter system is not installed onboard the vessel.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 September 2021
Resolved 15 January 2022
Resolution: Bridge Alerter System installed onboard the vessel.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 24 August 2021 Resolved
The safety of the towing vessel is the responsibility of the master and includes adherence to the provisions of the COI. Inspector found that the master entirely lacks knowledge of the Certificate of Inspection and has operated the vessel beyond the permitted route (i.e. completed unpermitted international voyage).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 September 2021
Resolved 21 October 2021
Resolution: Vessel master has reviewed the issued COI.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 August 2021 Resolved
Chemical testing of personnel must be conducted as required by this subpart and in accordance with the procedures detailed in 49 CFR part 40. Inspector found that the vessel operator does not have alcohol and drug collection kits onboard to enable specimen collection within the required time frames.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 September 2021
Resolved 30 August 2021
Resolution: Alcohol collection kit has been placed onboard the vessel.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 24 August 2021 Resolved
AIS must be maintained in effective operating condition, which includes the ability to reinitialize the AIS, which requires access to and knowledge of the AIS power source and password; additionally, accurate input and upkeep of all AIS data fields and system updates is required. Inspector found that the vessel master does not have access to the AIS password and lacks familiarity to effectively update the vessels operational data (e.g. length of tow, underway status).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 September 2021
Resolved 21 October 2021
Resolution: The local (Long Beach) FCC technician provided training to the vessels crew regarding use and updates to the AIS.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 24 August 2021 Resolved
A towing vessel must carry adequate an up-to-date charts/maps for the intended voyage and of appropriate scale to make safe navigation possible. Inspector found that the paper charts date of revision is not the most recent.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 September 2021
Resolved 21 October 2021
Resolution: New charts have been placed onboard the vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 24 August 2021 Resolved
Each life jacket must be marked in block capital letters with the name of the vessel and have the following attachments: life-jacket-light approved under approval series 161.012 or 161.112 and have a whistle secured by a cord. Inspector found that the onboard life jackets are not in full compliance with vessel name, light, and whistle requirements.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 September 2021
Resolved 21 October 2021
Resolution: PFD's have been outfitted with the required items.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 24 August 2021 Resolved
Each towing vessel must be maintained and operated so as to minimize fire hazards. Inspector found that fire block/insulation associated with a cable penetration from the machinery space into a common space is not fully packed and could allow the passage of smoke/flame/heat.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 September 2021
Resolved 21 October 2021
Resolution: Cable penetration has been repaired to prevent the passage of flame and smoke.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 5 June 2020 Resolved
Each towing vessel must be equipped with navigation lights in accordance with the International Regulations for Prevention of Collisions at Sea (COLREGS) or 33 CFR 84 as appropriate to its area of operation.Additionally, 46 CFR 111.75-20(d)(1) Subchapter J states, Each fixture in the weather or in a location exposed to splashing water must be watertight. Each fixture in a damp or wet location must at least be dripproof. The stern facing amber towing light was found to have a cracked protective globe rendering the fixture susceptible to the entry of water (i.e. not watertight).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 July 2020
Resolved 7 July 2020
Resolution: The protective was replaced and installed properly to prevent water intrusion.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 June 2020 Resolved
46CFR141.370: At least two lifebuoys on a towing vesssel greater than 26 feet must be fitted with a floating electric water light.The port side (upper deck near pilot house) did not have the floating electric water light attached. The water light was present and stowed in its retainer but it was tied to the lifebuoy (i.e. life ring).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 July 2020
Resolved 7 July 2020
Resolution: Water light was connected to buoy utilizing dark colored line (UV resistant).
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 June 2020 Resolved
46CFR141.340(f)(1) Each lifejacket must be marked in block capital letters with the name ofthe vessel.All lifejackets were marked with incorrect vessel name (i.e. not marked as PONO).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 July 2020
Resolved 7 July 2020
Resolution: Life jackets have been corrected and are now marked with the vessel name PONO.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.