WAIALEALE

Built
1991
Last inspected
8 May 2023
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard.

Inspection record

Last inspected 8 May 2023
…with no type recorded36
Operational controls None recorded without a removal date
Years with a record 31 calendar years (1991–2023)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

363143
Flag
UNITED STATES
Tonnage
6870 - Regulatory (Subpart C or D), Gross Ton 7735 - Convention (Subpart B), Gross Ton 6870 - Regulatory (Subpart C or D), Net Ton 2320 - Convention (Subpart B), Net Ton
Maury page id
psix-363143
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 12

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. Only barges and towing vessels are in this archive, so any other vessel type in the same activity does not appear here: these lists are a floor, not a complete manifest.

KAHU Towing Vessel · MISLE 138921 · 19 January 2020 · activity 6900784PI ILANI Towing Vessel · MISLE 757613 · 19 January 2020 · activity 6900784HARRIET O Towing Vessel · MISLE 112647 · 12 June 2015 · activity 5155199NOLA GAIL Towing Vessel · MISLE 111613 · 3 January 2015 · activity 5047309CAPE LOOKOUT Towing Vessel · MISLE 490561 · 3 January 2015 · activity 5047309MIKIOI Towing Vessel · MISLE 692194 · 3 January 2015 · activity 5047309DUPLICATE OF PIILANI Towing Vessel · MISLE 1322000 · 3 January 2015 · activity 5047309NOLA GAIL Towing Vessel · MISLE 111613 · 7 February 2014 · activity 4798925CLAYTON ARTHUR Towing Vessel · MISLE 44914 · 6 August 2012 · activity 4417251HARRIET O Towing Vessel · MISLE 112647 · 22 August 2010 · activity 3902955NOLA GAIL Towing Vessel · MISLE 111613 · 28 July 2010 · activity 3810687HALEAKALA Freight Barge · MISLE 240704 · 28 June 2004 · activity 2162167PONO Towing Vessel · MISLE 392995 · 28 June 2004 · activity 2162167HARRIET O Towing Vessel · MISLE 112647 · 16 May 2004 · activity 2070845HOLO KAI Tank Barge · MISLE 43416 · 9 January 1997 · activity 44375ELISABETH Towing Vessel · MISLE 91837 · 9 January 1997 · activity 44375ELISABETH Towing Vessel · MISLE 91837 · 30 August 1995 · activity 33591

Inspection history · 101

8 May 2023 Load Line/Change of Employment
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7684106
17 August 2021 Exemption
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7288948
30 November 2020 Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7103595
19 January 2020 Administrative Inspection · Examination of Repairs · Damage Survey
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6892503
19 January 2020 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6900784
21 October 2019 In-Service Inspection · Administrative Inspection · Periodic Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6836946
25 October 2018 MTSA Verification · Annual Inspection · Administrative Inspection · In-Service Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6568525
13 November 2017 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6306046
3 December 2016 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6052931
18 November 2016 Explosive Handling Operation-Commercial
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6043791
16 September 2016 Internal Structural Exam · COI Inspection · Drydock Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6002580
5 April 2016 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5847340
29 February 2016 Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5823564
29 February 2016 Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5824300
23 November 2015 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5809924
12 June 2015 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5155199
14 April 2015 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5103268
6 April 2015 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5097889
3 January 2015 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5047309
18 December 2014 Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5036456
8 November 2014 Administrative Inspection · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5019857
17 April 2014 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4838483
12 April 2014 Deficiency Check · Damage Survey · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4835867
12 April 2014 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4836175
7 February 2014 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4798925
16 January 2014 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4784974
9 December 2013 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4766724
31 October 2013 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4747358
12 October 2013 Damage Survey
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4733911
12 October 2013 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4735064
4 December 2012 Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4496248
6 August 2012 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4417251
22 December 2011 Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4212942
12 December 2011 Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4207298
21 November 2011 Deficiency Check · COI Inspection · Hull Examination · Internal Structural Exam
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4161120
5 August 2011 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4106193
23 July 2011 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4093996
6 December 2010 Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3890281
18 October 2010 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3877428
22 August 2010 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3902955
30 July 2010 Damage Survey · Examination of Repairs
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3827994
28 July 2010 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3810687
9 September 2009 Periodic Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3590177
5 August 2009 Examination of Repairs · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3556360
8 July 2009 Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3528555
3 March 2009 Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3426922
20 February 2009 Damage Survey
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3422585
19 February 2009 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3425215
6 January 2009 Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3389511
17 November 2008 MTSA Verification · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3362645
23 April 2008 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3199537
7 January 2008 Annual Inspection · MTSA Verification
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3126069
15 November 2006 Internal Structural Exam · Hull Examination · Examination of Repairs · COI Inspection · Deficiency Check
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2799098
21 September 2005 Annual Inspection · MTSA Verification
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2497945
12 July 2005 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2424498
28 June 2005 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2408031
30 March 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2322869
15 November 2004 Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2243901
29 September 2004 Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2209048
27 September 2004 Annual Inspection · MTSA Verification
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2207405
28 June 2004 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2162167
17 May 2004 Damage Survey
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2071229
16 May 2004 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2070845
5 February 2004 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2003442
30 December 2003 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1971381
24 November 2003 Annual Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1952253
5 September 2002 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1674350
22 July 2002 Annual Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1643598
8 December 2001 Hull Examination · Internal Structural Exam
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1362595
26 September 2001 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1074663
13 September 2001 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1072176
13 August 2001 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1069453
13 August 2001 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1382359
10 August 2000 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1376293
23 March 2000 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 182900
29 November 1999 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 812659
14 November 1999 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 808579
30 September 1999 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1406574
19 August 1999 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1361065
1 April 1999 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 754612
31 March 1999 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 199611
24 September 1998 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 799014
19 August 1998 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1437442
26 July 1998 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 183276
21 August 1997 COI Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1375104
12 January 1997 Examination of Repairs · Damage Survey
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1096861
9 January 1997 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 44375
12 September 1996 Re-Inspection · Hull Examination · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1354018
5 September 1995 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1185465
30 August 1995 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 33591
30 August 1995 Damage Survey
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1355420
25 August 1995 COI Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1355421
16 September 1994 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1403830
14 September 1994 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1354906
17 September 1993 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1147796
30 August 1993 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1379847
13 August 1993 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1354434
18 September 1992 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 959667
27 March 1992 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 948488
24 January 1992 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 952894
19 September 1991 Hull Examination · Initial Certification
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1243577

Deficiency record · 136

02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 30 November 2020 Resolved
All electrical engineering details and installations shall be designed and installed in accordance with sub chapter J (Electrical Engineering) of this chapter. Multiple dead end wires were found in the generator room behind the generator gauges, above a tank, and under the generator platform.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 December 2020
Resolved 3 December 2020
Resolution: Dead end wires have been capped appropriately.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 30 November 2020 Resolved
All electrical engineering details and installations shall be designed and installed in accordance with sub chapter J (Electrical Engineering) of this chapter. The starboard generator is leaking cooling water.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 December 2020
Resolved 3 December 2020
Resolution: Starboard generator cooling water leak has been corrected by removing the pipe, cleaning the threads, and reseating.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 30 November 2020 Resolved
All vessels shall have efficient guard rails or bulwarks on decks and bridges. The 02 level deck aft ladder inboard rail has a cracked weld at the deck.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 December 2020
Resolved 3 December 2020
Resolution: The 02 level deck aft ladder inboard rail cracked weld has been rewelded to a satisfactory condition.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 21 October 2019 Resolved
Conduct annual servicing of the Carbon Dioxide fire suppression system in the presence of a Coast Guard marine inspector. Servicing of the CO2 fire suppression system must be completed prior to October 25, 2019. After October 25, 2019, this deficiency will need to be cleared prior to departure. 46 CFR 91.25-20
Action required: 705 - Other - as specified
Due 25 October 2019
Resolved 24 October 2019
Resolution: Annual servicing completed by third party and tested.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 21 October 2019 Resolved
Conduct annual servicing of all fire extinguishers required by the vessel's certificate of inspection. Servicing of the fire extinguishers must be completed prior to October 25, 2019. After October 25, 2019, this deficiency will need to be cleared prior to departure. 46 CFR 91.25-20
Action required: 705 - Other - as specified
Due 25 October 2019
Resolved 24 October 2019
Resolution: Annual servicing completed by third party.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 October 2019 Resolved
Each item of installed electrical equipment must meet the requirements for a Class I, Division 1; Class I, Division 2; Zone 0; Zone 1; or Zone 2 hazardous location when installed 460 mm (18 inches) or more above the deck of closed cargo spaces. Electrical equipment installed within 460 mm (18 inches) of the deck must be suitable for either a Class I, Division 1; Zone 0; or Zone 1 hazardous location. Renew shore connection box on starboard side to one suitable for the space in which it is located. 46 CFR 111.105-40(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 November 2019
Resolved 24 October 2019
Resolution: Shore connection box renewed in kind.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 21 October 2019 Resolved
Piping, including valves, pipe fittings and flanges, conveying vapors, gases or liquids whose temperature exceeds 150 °F., shall be suitably insulated where necessary to preclude injury to personnel. Install insulation on both #1 and #2 generator exhaust piping. 46 CFR 56.50-1(k)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 November 2019
Resolved 24 October 2019
Resolution: Exhaust insulation installed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 21 October 2019 Resolved
Coamings of any fiddley or skylight over a machinery space opening in the freeboard or superstructure deck must have covers of steel permanently attached and capable of being secured weathertight. Vessel's steel coaming for the machinery space ventilation weathertight closure was found deformed and unable to close. 46 CFR 45.149 (e)
Action required: 705 - Other - as specified
Due 25 October 2019
Resolved 24 October 2019
Resolution: Coaming was heated and bent back to original position. Hatch closes to form weathertight boundary in space.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 21 October 2019 Resolved
Complete but simple instructions for the operation of the CO2 systems must be located in a conspicuous place at or near all pull boxes, stop valve controls and in the CO2 cylinder storage room. Vessel is missing instructions and pull cable labels at the machinery room pull station and is missing pull cable labels at the forward pull station. 46 CFR 95.15-10 (h)
Action required: 705 - Other - as specified
Due 25 October 2019
Resolved 24 October 2019
Resolution: CO2 instructions found posted. All pull cables found labeled.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 21 October 2019 Resolved
The registration and fee requirements of this subpart apply to any person who offers for transportation, in intrastate commerce; a quantity of hazardous material that requires placarding. Vessels Hazmat Certificate of Registration is expired. 49 CFR 107.601 (a)(6)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 November 2019
Resolved 24 October 2019
Resolution: Valid Hazmat registration found onboard.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 13 November 2017 Resolved
Allow for CG witness of fixed CO2 testing from fire servicing company
Action required: 705 - Other - as specified
Due 4 December 2017
Resolved 27 November 2017
Resolution: Witnessed satisfactory testing of CO2 system.
Engineering › Lubricating Oil Service System › Hose
Issued 29 February 2016 Resolved
Replace upper 3 hydraulic hoses on stbd aft ramp.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 February 2016
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 23 November 2015 Resolved
Prover proper operation of vented control head on CO2 bottles for fixed CO2 fire extinguishing system
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 23 November 2015
Resolved 23 November 2015
Resolution: [name withheld] fire servicing representatives identifed that the pull cable had become disconnected within the control head. Reps reconnected the pull cable and tightened connections. Tests of manual pull cable were sat.
Engineering › Freshwater System (jacketwater cooling) › Valve Manifold
Issued 23 November 2015 Resolved
Repair jacket water coolant leak on port generator.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 December 2015
Resolved 17 December 2015
Resolution: Verified leak on port generator was repaired. All sat.
Stability › Watertight Integrity › General
Issued 23 November 2015 Resolved
Conduct maintenance of dogs for FWD Port side water tight doors. Ensure dogs are not seized and freely operate by hand.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 December 2015
Resolved 17 December 2015
Resolution: Verified dogs on port FWD watertight hatch operated freely, all sat.
Documentation › Logs/Records › Oil Record Book
Issued 23 November 2015 Resolved
Ensure master signs all pages in the oil record book
Condition: Invalid
Action required: 705 - Other - as specified
Due 23 December 2015
Resolved 17 December 2015
Resolution: Verified pages in the Oil Record book were signed and dated. All sat.
Engineering › Pressure Vessel › Relief Valve
Issued 23 November 2015 Resolved
Verify MAWP of air compressors and demonstrate proper operation of safety relief valves for ship service air receivers
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 December 2015
Resolved 17 December 2015
Resolution: Witnessed satisfactory test of #1 and #2 air receiver safety relief valves. All sat
Electrical › Electric Supply System (service) › Battery Charger
Issued 23 November 2015 Resolved
Provide ammeter in charging circuit for battery charger & provide splash guard that adequately protects battery charger from water splash.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 December 2015
Resolved 17 December 2015
Resolution: Verified ammeter was installed in charging circuit for nav light battery charger and adequate splash guard was installed to shield charger from dripping water. All sat.
Engineering › Freshwater System (jacketwater cooling) › Sensor
Issued 23 November 2015 Resolved
Prove proper operation of generator high temperature alarm
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 March 2016
Resolved 25 February 2016
Resolution: Demonstrated proper operation of generator high jacket water temperature trips.
Engineering › Lubricating Oil Service System › Hose
Issued 12 April 2014 Resolved
Hydraulic hose was installed on car ramp but was installed in 2011 drydock.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 April 2014
Resolved 15 April 2014
Resolution: New hose is installed and date of manufacturer is July 2012, J1942 is not stamped on hose but is J1942 compliant.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 16 January 2014 Resolved
All emergency lights were inoperative, possibly battery or bulbs
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 February 2014
Resolved 3 February 2014
Resolution: Tested Sat
Engineering › Engine Controls (Electric/Electronic) › Actuator
Issued 16 January 2014 Resolved
Replace bothe engines jacket water hot water sensor with calibrated sensor.
Action required: 705 - Other - as specified
Due 16 February 2014
Resolved 3 February 2014
Resolution: Tested Sat, company gave certificate and USCG marked exterior of sensor. Which another sensor that is not marked but has a current calibration certificate issued for following years.
Fire Fighting › Remote Fuel Shutoff › General
Issued 16 January 2014 Resolved
The reach rod does move to close, however the housing for the reach rod is broken where the "cup" that houses the socket end is broken and spins with valve as it is closing.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 16 February 2014
Resolved 3 February 2014
Resolution: Tested Sat
Engineering › Thrusters › Seal
Issued 12 October 2013 Resolved
Small Hydraulic leak in port ram.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 12 October 2013
Resolved 12 October 2013
Resolution: Replaced entire ram with new.
Electrical › Lighting (service) › Lighting Fixture
Issued 4 December 2012 Resolved
Repair broken light covers upper deck.
Action required: 705 - Other - as specified
Due 19 December 2012
Resolved 28 January 2013
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 4 December 2012 Resolved
Repiar broken stbd side fwd CO2 mounting bracket upper deck.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 December 2012
Resolved 28 January 2013
Electrical › Lighting (service) › Lighting Fixture
Issued 4 December 2012 Resolved
Repair broken light cover port fan space.
Action required: 705 - Other - as specified
Due 19 December 2012
Resolved 28 January 2013
Electrical › Electrical Distribution System (service) › Wiring
Issued 4 December 2012 Resolved
Provide wire banding for electical cable upper deck stern.
Action required: 705 - Other - as specified
Due 19 December 2012
Resolved 28 January 2013
Construction/Loadline › Structures › Door
Issued 4 December 2012 Resolved
Prove proper operation of dogs for WTD located near ramp stbd side.
Action required: 705 - Other - as specified
Due 19 December 2012
Resolved 4 December 2012
Electrical › Lighting (emergency) › Lighting Fixture
Issued 4 December 2012 Resolved
Prove proper operation of emergency lightingin eng space located near switchboard.
Action required: 705 - Other - as specified
Due 19 December 2012
Resolved 28 January 2013
Engineering › Thrusters › Piping
Issued 4 December 2012 Resolved
#1 stern thruster pump - excessive hydraulic leak. Make proper repairs.
Action required: 705 - Other - as specified
Due 19 December 2012
Resolved 28 January 2013
Fire Fighting › Portable CO2 Fire Extinguisher › Discharge Hose/Tube
Issued 4 December 2012 Resolved
Fire extinguisher located outboard #2 gen hose wasted.
Action required: 705 - Other - as specified
Due 19 December 2012
Resolved 28 January 2013
Engineering › Sea-water System (primary cooling) › Piping
Issued 4 December 2012 Resolved
s/w ovbd cooling lines for #1 and #2 gen wasted provide new lines.
Action required: 705 - Other - as specified
Due 19 December 2012
Resolved 28 January 2013
Electrical › Lighting (service) › Lighting Fixture
Issued 4 December 2012 Resolved
Light cover above #2 stern thruster broken.
Action required: 705 - Other - as specified
Due 19 December 2012
Resolved 28 January 2013
Deck/Cargo › Ballast › Vents
Issued 4 December 2012 Resolved
Make proper repair to vent pipe located near port ballast pump.
Action required: 705 - Other - as specified
Due 19 December 2012
Resolved 28 January 2013
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 21 November 2011 Resolved
Provide proof of properly installed mat black inboard screen for PORT & STBD side lights to marine inspector.
Due 21 December 2011
Resolved 22 December 2011
Fire Fighting › Fixed CO2 Fire Extinguishing System › Automatic Heat Detectors
Issued 21 November 2011 Resolved
Prior to loading cargo provide proof of proper operation for automatic discharge for fix CO2 system as certificated and designed to attending marine inspector.
Due 21 December 2011
Resolved 12 December 2011
Documentation › Markings/Placards › Warning Signs
Issued 6 December 2010 Resolved
Properly label emergency shutdown located outside house.
Action required: 705 - Other - as specified
Due 21 December 2010
Resolved 21 January 2011
Documentation › Markings/Placards › Warning Signs
Issued 6 December 2010 Resolved
Properly label CO2 remote starters located outside house.
Action required: 705 - Other - as specified
Due 21 December 2010
Resolved 21 January 2011
Construction/Loadline › Hull › Hull Plating
Issued 30 July 2010 Resolved
Crop and renew all inset areas on port bow (rake) identified by ABS. In addition, crop and renew fractured bottom plate IVO 2 smaller insets outboard port rake by #1 and #2 longitudinal. After cropping, make available for USCG inspection prior to commencing repairs.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 August 2010
Construction/Loadline › Hull › Hull Plating
Issued 30 July 2010 Resolved
Make fit up and final weld test available for inspection by USCG and/or ABS.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 August 2010
Construction/Loadline › Hull › Hull Plating
Issued 30 July 2010 Resolved
Submit diagram and specifications of repair to USCG for vessel file.
Action required: 705 - Other - as specified
Due 30 August 2010
Resolved 2 August 2010
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 22 October 2009 Resolved
Provide 3rd party report attesting to the satisfaction of material condition of flexible loop hoses.
Due 13 November 2009
Resolved 29 October 2009
Resolution: Received same with indication that all lines had been tested.
Engineering › Fuel Oil Service System › Vent Pipe
Issued 9 September 2009 Resolved
Found vent screen corroded and clogged. Renew fuel tank vent screen.
Due 30 September 2009
Resolved 24 September 2009
Documentation › Certificates/Documents › Stability Letter
Issued 9 September 2009 Resolved
Provide valid stabiliy letter.
Due 30 September 2009
Resolved 24 September 2009
Documentation › Safety/Response Plans/Programs › SOPEP
Issued 9 September 2009 Resolved
Provide CG/Class SOPEP Approval letter.
Due 30 September 2009
Resolved 18 September 2009
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 9 September 2009 Resolved
Provide NTVRP with Approval letter.
Due 30 September 2009
Resolved 30 September 2009
Resolution: Entered in error, not required for non self propelled vsls.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 9 September 2009 Resolved
Make repairs to broken rail stanchion on bow, in way of port towing bridle chain plate, (first stanchion inboard of plate)
Due 30 September 2009
Resolved 24 September 2009
Construction/Loadline › Hull › Bracket
Issued 9 September 2009 Resolved
Crop and renew damaged (bent/cracked) gusset at top of vertical deck support at frame #24, port side, main deck.
Due 15 November 2011
Resolved 1 November 2011
Resolution: Port Engineer crop and renewed gussets.
Construction/Loadline › Hull › Longitudinal Frame
Issued 9 September 2009 Resolved
In #2 stbd void: crop and renew deflected Side long #2 btwn frames 5 and 6. CWO R.Oakley.
Due 15 November 2011
Resolved 2 November 2011
Resolution: Side long was cropped, renewed, and properly aligned.
Construction/Loadline › Hull › Longitudinal Frame
Issued 9 September 2009 Resolved
In #3 stbd void: crop and renew tripped side frame #3, IWO #2 side long. [name withheld]
Due 15 November 2011
Resolved 1 November 2011
Resolution: Side frame crop, renewed, and properly aligned.
Construction/Loadline › Hull › Transverse Frame
Issued 9 September 2009 Resolved
In #2 port void: crop and renew tripped side frame #7, IWO #3 side long
Due 15 November 2011
Resolved 2 November 2011
Resolution: Side framed crop, renewed, and properly aligned.
Construction/Loadline › Hull › Transverse Frame
Issued 9 September 2009 Resolved
In #4 port void: crop and renew tripped side frame #1, IWO of #4 side long. [name withheld]
Due 15 November 2011
Resolved 2 November 2011
Resolution: Side frame crop, renewed, and properly aligned.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 9 September 2009 Resolved
Provide covers for A/C refrigeration receptacles on the main deck, (center aft end of house).
Due 15 November 2011
Resolved 1 November 2011
Resolution: Covers were placed on all refrigeration receptacles on the main deck.
Construction/Loadline › Structures › Deck Plating
Issued 5 August 2009 Resolved
Plate #8 : 22" x 36" x 5/16, 01 deck.
Condition: Unknown
Action required: 705 - Other - as specified
Due 7 August 2009
Resolved 7 August 2009
Construction/Loadline › Structures › Deck Plating
Issued 5 August 2009 Resolved
Insert #6: 18" x 18" x 5/16" - 01 deck. near fm 6
Condition: Unknown
Action required: 705 - Other - as specified
Due 7 August 2009
Resolved 7 August 2009
Construction/Loadline › Structures › Deck Plating
Issued 5 August 2009 Resolved
Insert #5: 48" x 72" x 5/16" located near fm 6, 01 deck.
Condition: Unknown
Action required: 705 - Other - as specified
Due 7 August 2009
Resolved 7 August 2009
Construction/Loadline › Structures › Deck Plating
Issued 5 August 2009 Resolved
Insert 21. 73" x 63" x 5/16 centerline fm 5. - 01 deck Inset 2.2 24 x 85 x 5/16 centerline fm 5.
Condition: Unknown
Action required: 705 - Other - as specified
Due 7 August 2009
Resolved 7 August 2009
Construction/Loadline › Structures › Deck Plating
Issued 5 August 2009 Resolved
Insert 12: 60" x 60" x 5/16 - 01deck
Condition: Unknown
Action required: 705 - Other - as specified
Due 7 August 2009
Resolved 7 August 2009
Construction/Loadline › Structures › Deck Plating
Issued 5 August 2009 Resolved
#4 insert: 18" insert x 5/16" - 01 deck
Condition: Unknown
Action required: 705 - Other - as specified
Due 7 August 2009
Resolved 7 August 2009
Construction/Loadline › Structures › Deck Plating
Issued 5 August 2009 Resolved
Insert #13: 18" x 18" located under ramp. 01deck
Condition: Unknown
Action required: 705 - Other - as specified
Due 7 August 2009
Resolved 7 August 2009
Construction/Loadline › Structures › Deck Plating
Issued 5 August 2009 Resolved
# 21 insert: 48" x 48" x 5/16 - 01 deck
Condition: Unknown
Action required: 705 - Other - as specified
Due 7 August 2009
Resolved 7 August 2009
Construction/Loadline › Structures › Deck Plating
Issued 5 August 2009 Resolved
Insert # 20: 18" x 18" x 5/16 - 01deck
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 7 August 2009
Resolved 7 August 2009
Construction/Loadline › Structures › Deck Plating
Issued 5 August 2009 Resolved
Insert #16: 24" x 24" x 5/16" 01 deck
Condition: Unknown
Action required: 705 - Other - as specified
Due 7 August 2009
Resolved 7 August 2009
Construction/Loadline › Structures › Deck Plating
Issued 5 August 2009 Resolved
Insert #4: 24" x 18" x 5/16 - 02 deck
Condition: Unknown
Action required: 705 - Other - as specified
Due 7 August 2009
Resolved 7 August 2009
Construction/Loadline › Structures › Deck Plating
Issued 5 August 2009 Resolved
Insert #6: 48" x 56" x 5/16 - 02 deck
Condition: Unknown
Action required: 705 - Other - as specified
Due 7 August 2009
Resolved 7 August 2009
Construction/Loadline › Structures › Deck Plating
Issued 5 August 2009 Resolved
Insert #5: 21'- 0" x 18" x 5/16 - 02 deck
Condition: Unknown
Action required: 705 - Other - as specified
Due 7 August 2009
Resolved 7 August 2009
Engineering › Thrusters › Motor
Issued 3 March 2009 Resolved
During the investigation of the vessel allision with Piers 25 and 27 it was discovered that the stern thruster was only operating at 70% of it's rated capacity. Identify the problem and make appropriate repairs.
Action required: 705 - Other - as specified
Due 27 March 2009
Resolved 9 March 2009
Resolution: During the system check the stern thruster indicated it was operating at %100
Construction/Loadline › Structures › Deck Plating
Issued 3 March 2009 Resolved
wastage has been identified on the auto ramp and decks and a plan has been approved to crop and renew the thinning areas in enterals beginning Febuary 2009 through the next scheduled dry dock in August 2009.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 August 2009
Resolved 7 August 2009
Construction/Loadline › Hull › Side Shell
Issued 20 February 2009 Resolved
Found inset at stbd bow, #2 Void between frames 4 and 6. Inset begins 4' below the main deck and measures 5' long by 3' high by 4" deep. Internal inspection by Matson and ABS revealed (3) shell plate insets between frames 4 & 6 set in 2"-4", #2 side longitudinal set in 4" with a slight buckle between frames 3 & 4. Make permanent repairs at sked Nov 2009 availability.
Action required: 705 - Other - as specified
Due 30 November 2009
Resolved 7 August 2009
Construction/Loadline › Hull › Side Shell
Issued 20 February 2009 Resolved
Found inset at stbd quarter void #7, starting 3 feet down from the main deck and measuring 8' long X 4' tall X 5" deep. Internal inspection by Matson and ABS found shell plate inset between frames #30 & 31. Stbd side longitudinals #1, 2, & 3 set in and buckled. Make permanent repairs at November 2009 availability.
Action required: 705 - Other - as specified
Due 30 November 2009
Resolved 9 March 2009
Resolution: Replacement of 2 longitudinal frames required by ABS completed. No side shell inserts conducted
Electrical › Electrical Distribution System (service) › Wiring
Issued 17 November 2008 Resolved
Provide metal fasteners for cable located aft 03 deck.
Condition: Unknown
Action required: 705 - Other - as specified
Due 7 December 2008
Resolved 6 January 2009
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 17 November 2008 Resolved
Repair guards for exhaust stacks located stbd aft 03 deck.
Condition: Unknown
Action required: 705 - Other - as specified
Due 7 December 2008
Resolved 6 January 2009
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 17 November 2008 Resolved
Provide electrical outlet covers on main deck.
Condition: Unknown
Action required: 705 - Other - as specified
Due 7 December 2008
Resolved 6 January 2009
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 17 November 2008 Resolved
Stencil valves and vents at bunkering station.
Condition: Unknown
Action required: 705 - Other - as specified
Due 7 December 2008
Resolved 6 January 2009
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Piping (exhaust)
Issued 17 November 2008 Resolved
Repair S/S generator exhaust lagging located in machine space.
Condition: Unknown
Action required: 705 - Other - as specified
Due 7 December 2008
Resolved 6 January 2009
Construction/Loadline › Structures › Deck Plating
Issued 17 November 2008 Resolved
Provide UT readings for 01 & 02 decks. Provide repair plan for wasted areas and areas that have doublers installed on deck. Repair plan to be submitted to Class and USCG for approval prior to starting work.
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 November 2009
Resolved 2 March 2009
Construction/Loadline › Structures › Superstructure
Issued 17 November 2008 Resolved
Make proper repair to fracture located on main deck stbd aft at ring frame for bollards.
Condition: Unknown
Action required: 705 - Other - as specified
Due 9 January 2009
Resolved 6 January 2009
Electrical › Lighting (service) › Lighting Fixture
Issued 21 September 2005 Resolved
Replace both starboard & port navlight boxes.
Action required: 705 - Other - as specified
Due 21 October 2005
Resolved 26 October 2005
Engineering › Compressed Air System (start air) › Compressor
Issued 21 September 2005 Resolved
Relag exhaust pipe on air compressor on 02 deck.
Action required: 705 - Other - as specified
Due 21 October 2005
Resolved 26 October 2006
Engineering › Pressure Vessel › Marking and Stamping
Issued 21 September 2005 Resolved
Clean off inboard identification plate on left pressure vessel on 02 deck.
Due 29 September 2005
Resolved 29 September 2005
Engineering › Pressure Vessel › Relief Valve
Issued 21 September 2005 Resolved
Drop relief valves on both pressure vessels located on 02 deck.
Action required: 705 - Other - as specified
Due 29 September 2005
Resolved 29 September 2005
Engineering › Generator (propulsion-electric) › System Grounding
Issued 21 September 2005 Resolved
Prove proper operation of 24V ground detection system.
Action required: 705 - Other - as specified
Due 21 October 2005
Resolved 26 October 2005
Fire Fighting › Remote Fuel Shutoff › General
Issued 21 September 2005 Resolved
Paint fuel shutoff valves on deck in contrasting colors
Action required: 705 - Other - as specified
Due 29 September 2005
Resolved 29 September 2005
Construction/Loadline › Structures › Deck Plating
Issued 21 September 2005 Resolved
#7 Port Void, crop/renew all brackets for bottom deck longs inbetween stern frames #1 & 2. in stern log. Crop/renew stern frame #1 at next dry dock.
Action required: 705 - Other - as specified
Due 8 December 2006
Resolved 15 November 2006
Resolution: Satisfactory repairs completed.
Construction/Loadline › Structures › Door
Issued 21 September 2005 Resolved
Prove proper operation of fwd. water tight doors.
Action required: 705 - Other - as specified
Due 24 October 2005
Resolved 26 October 2005
Electrical › Lighting (service) › Lighting Fixture
Issued 21 September 2005 Resolved
Replace port & starborad fan room light.
Action required: 705 - Other - as specified
Due 24 October 2005
Resolved 26 October 2005
Construction/Loadline › Structures › Rake
Issued 30 September 2004 Resolved
Repair damage in # 7 port void in way of # 1 and # 2 bottom long brackets to # 1 and # 2 side longs at after port corner. Item is to be completed during next scheduled hull exam.
Action required: 705 - Other - as specified
Due 30 September 2006
Resolved 15 November 2006
Resolution: Satisfactory repairs completed.
Construction/Loadline › Structures › Rake
Issued 30 September 2004 Resolved
Repair damage in # 7 port void in way of # 6 and # 7 bottom longs - # 6 bottom long at aft frame, repair or renew and # 7 bottom long bracket to # 1 side long at transom. Item is to be completed during next scheduled hull exam.
Action required: 705 - Other - as specified
Due 30 September 2006
Resolved 15 November 2006
Resolution: Satisfactory repairs completed.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 27 September 2004 Resolved
Properly mount all electrical outlets and provide applicable outlet covers.
Condition: Unknown
Action required: 705 - Other - as specified
Due 27 October 2004
Resolved 15 November 2004
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 27 September 2004 Resolved
Provide break glass for fixed fire extinguishing system control box on the port side main deck.
Condition: Unknown
Action required: 705 - Other - as specified
Due 27 October 2004
Resolved 15 November 2004
Electrical › Electrical Distribution System (service) › Switchboard
Issued 27 September 2004 Resolved
Prove proper operation of reverse power relay on the #2 SSDG.
Condition: Unknown
Action required: 705 - Other - as specified
Due 27 September 2004
Resolved 27 September 2004
Fire Fighting › Ventilation Systems › Operating Controls
Issued 27 September 2004 Resolved
Prove proper operation of main deck port side fire damper.
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 October 2004
Resolved 15 November 2004
Construction/Loadline › Structures › Superstructure
Issued 27 September 2004 Resolved
Properly repair deck longs #5 and #13 from aft for second deck at the next drydock.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 September 2006
Resolved 15 November 2006
Resolution: Satisfactory repairs completed.
Construction/Loadline › Structures › Deck Plating
Issued 27 September 2004 Resolved
Properly repair upper cargo deck aft of Frame 23 NLT next drydock. No cargo to be carried aft of Frame 23 on upper deck until repairs are approved by USCG.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 September 2006
Resolved 15 November 2006
Resolution: Satisfactory repairs completed.
Construction/Loadline › Hull
Issued 17 May 2004 Resolved
Make temporary repairs to damage in way of the Stbd Aft Rake stbd outboard corner prior to operating the barge.
Due 18 May 2004
Resolved 18 May 2004
Construction/Loadline › Hull › Hull Plating
Issued 17 May 2004 Resolved
Make permanent repairs to Aft Stbd Rake stbd outboard corner to include the side, stern log, & bottom shell plating, and the affected structural steel including side longs, bottom longs & deck longs.
Action required: 705 - Other - as specified
Due 1 June 2004
Resolved 1 June 2004
Electrical › Lighting (emergency)
Issued 24 November 2003 Resolved
Prove proper operation of emergency lighting in upper level of engineroom. LEGACY COMPONENT DESC: Battery Operated Lantern
Action required: 705 - Other - as specified
Due 24 November 2003
Resolved 24 November 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 24 November 2003 Resolved
Provide dogging wrenches for watertight door to engineroom.
Condition: Unknown
Action required: 705 - Other - as specified
Due 24 November 2003
Resolved 24 November 2003
Engineering › Compressed Air System (start air)
Issued 24 November 2003 Resolved
Properly support new air bleed line for compressors.
Action required: 705 - Other - as specified
Due 24 November 2003
Resolved 24 November 2003
Fire Fighting › Ventilation Systems
Issued 24 November 2003 Resolved
Prove proper operation of port and starboard fire dampers on both the 1st and 2nd cargo decks.
Action required: 705 - Other - as specified
Due 24 November 2003
Resolved 24 November 2003
Documentation › Logs/Records
Issued 24 November 2003 Resolved
Provide copy of fire fighting servicing report.
Action required: 705 - Other - as specified
Due 24 November 2003
Resolved 24 November 2003
Navigation › Collision/Grounding Avoidance
Issued 22 July 2002 Resolved
Replace fogged over sternlight lens cover. LEGACY COMPONENT DESC: Navigation Lights
Action required: 705 - Other - as specified
Due 21 August 2002
Resolved 20 August 2002
Resolution: Satisfactory lens replacement installed.
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 22 July 2002 Resolved
Clean or replace unreadable labels for CO2 pull station located outside of the engine room. LEGACY COMPONENT DESC: Labeling
Action required: 705 - Other - as specified
Due 21 August 2002
Resolved 20 August 2002
Resolution: Witnessed photo documentation of cleaned labels.
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 22 July 2002 Resolved
Label local CO2 pull locations (1, 2, 3) in accordance with posted instructions. LEGACY COMPONENT DESC: Labeling
Action required: 705 - Other - as specified
Due 21 August 2002
Resolved 20 August 2002
Resolution: Witnessed photo documentation of new labels.
Engineering › Generator (propulsion/auxiliary-electric)
Issued 22 July 2002 Resolved
Label emergency engine shut-off at engine room door. LEGACY COMPONENT DESC: Emergency Shutoff
Action required: 705 - Other - as specified
Due 21 August 2002
Resolved 20 August 2002
Resolution: Witnessed photo documentation of new label.
Pollution Prevention/Response › Prevention Equipment
Issued 22 July 2002 Resolved
Post oil discharge placard(s). LEGACY COMPONENT DESC: Placards
Action required: 705 - Other - as specified
Due 21 August 2002
Resolved 20 August 2002
Resolution: Witnessed photo documentation of newly installed placard.
Accommodation/Occupational Safety › Occupational Safety
Issued 22 July 2002 Resolved
Label emergency escape scuttle leading form engine room (from the outside). LEGACY COMPONENT DESC: Labeling
Action required: 705 - Other - as specified
Due 21 August 2002
Resolved 20 August 2002
Resolution: Witnessed photo documentation of new label.
Fire Fighting › Structural - Horizontal Zones
Issued 22 July 2002 Resolved
Perform maintenance to port and starboard fire dampers on the 1st cargo deck and to the starboard damper(s) on the 2nd cargo deck. LEGACY COMPONENT DESC: Fire Dampers
Action required: 705 - Other - as specified
Due 21 August 2002
Resolved 20 August 2002
Resolution: Maintenance performed to free up dampers. Witnessed photo documentation of new reach rod for dampers.
Construction/Loadline
Issued 13 August 2001 Resolved
Replace the following watertight door gaskets: engine space, and_x001C_ port and starboard forward-most doors (bow). IAW: ICLL 66
Condition: Unknown
Due 13 August 2001
Resolved 13 August 2001
Electrical
Issued 13 August 2001 Resolved
Repair dead-end electrical wires on port and stbd generators. IAW 46 CFR 111.60.11.
Condition: Unknown
Due 13 August 2001
Resolved 13 August 2001
Documentation
Issued 13 August 2001 Resolved
Barge is not to operate (commercial trade operations) until proof of valid documentation certificate is provided to the cognizant OCMI.
Condition: Unknown
Due 17 August 2001
Resolved 17 August 2001
Construction/Loadline
Issued 30 September 1999 Resolved
Crop and renew #3 side shell long in way of frame 7 1/2 and 8 to the satisfaction of the attending marine inspector in accordance with NVIC 7- 68.
Condition: Unknown
Due 30 September 1999
Resolved 30 September 1999
Construction/Loadline
Issued 30 September 1999 Resolved
Crop and renew #3 side shell long 18 inches forward and 18 inches aft of frame 10 to the satisfaction of the attending marine inspector in accordance with NVIC 7-68.
Condition: Unknown
Due 30 September 1999
Resolved 30 September 1999
Construction/Loadline
Issued 30 September 1999 Resolved
Insert 3 foot by 3 foot section between frame 10/11 between the seem and #3side shell long to the satisfaction of the attending marine inspector in accordance with NVIC 7-68.
Condition: Unknown
Due 30 September 1999
Resolved 30 September 1999
Construction/Loadline
Issued 30 September 1999 Resolved
Crop and renew frame 8 in way of #2 through #4 side shell longs to the satisfaction of the attending marine inspector in accordance with NVIC 7- 68.
Condition: Unknown
Due 30 September 1999
Resolved 30 September 1999
Construction/Loadline
Issued 30 September 1999 Resolved
Crop and renew frame 9 in way of #2 through #3 side shell long to the satisfaction of the attending marine inspector in accordance with NVIC 7- 68.
Condition: Unknown
Due 30 September 1999
Resolved 30 September 1999
Construction/Loadline
Issued 30 September 1999 Resolved
Crop and renew #3 side shell long 3 feet forward and 1 foot aft of frame 9 to the satisfaction of the attending marine inspector in accordance with NVIC 7-68.
Condition: Unknown
Due 30 September 1999
Resolved 30 September 1999
Construction/Loadline
Issued 30 September 1999 Resolved
Crop and renew #'s 1,2, and 3 tripping brackets in way of bulkhead #13 to the satisfaction of the attending marine inspector in accordance with NVIC 7-68.
Condition: Unknown
Due 30 September 1999
Resolved 30 September 1999
Construction/Loadline
Issued 30 September 1999 Resolved
Crop and renew #3 side shell long in way of frames 11 and 12; 18 inches forward of frame 11 to 18 inches aft of frame 12 to the satisfaction of theattending marine inspector in accordance with NVIC 7-68.
Condition: Unknown
Due 30 September 1999
Resolved 30 September 1999
Construction/Loadline
Issued 30 September 1999 Resolved
Crop and renew frame 10 from the #1 side shell long down 10 feet to the satisfaction of the attending marine inspector in accordance with NVIC 7- 68.
Condition: Unknown
Due 30 September 1999
Resolved 30 September 1999
Construction/Loadline
Issued 30 September 1999 Resolved
Crop and renew frame 11 6 inches above #1 side shell long down 10.5 feet tothe satisfaction of the attending marine inspector in accordance with NVIC 7-68.
Condition: Unknown
Due 30 September 1999
Resolved 30 September 1999
Engineering
Issued 19 August 1998 Resolved
PROVE PROPER OPERATION OF #1 SSDG LOW L/O ALARM AND SHUT DOWN.
Condition: Unknown
Due 19 August 1998
Resolved 19 August 1998
Electrical
Issued 19 August 1998 Resolved
REMOVE DEAD END CABLE FROM UPPER LEVEL OF MACHINERY SPACE.
Condition: Unknown
Due 19 August 1998
Resolved 19 August 1998
Electrical
Issued 19 August 1998 Resolved
MAKE CABLE RUN TO THE STERN NAVIGATIONAL LIGHT WATERTIGHT.
Condition: Unknown
Due 19 August 1998
Resolved 19 August 1998
Electrical
Issued 19 August 1998 Resolved
REMOVE ALL NYLON AND PLASTIC WIRE TIES THROUGHOUT VESSEL, REPLACE WITH APPROVED METAL TYPE WIRE TIES.
Condition: Unknown
Due 19 August 1998
Resolved 19 August 1998
Construction/Loadline
Issued 30 August 1995 Resolved
Make proper repairs to fractured under deck transverse stiffener in number seven starboard wing in way of king post.
Condition: Unknown
Due 30 August 1995
Resolved 30 August 1995
Construction/Loadline
Issued 30 August 1995 Resolved
Repair as original starboard king post.
Condition: Unknown
Due 30 August 1995
Resolved 30 August 1995
Electrical
Issued 25 August 1995 Resolved
PROVE OPERATION OF THE CO2 SHUTDOWN ON THE NUMBER 1 GENERATOR.
Condition: Unknown
Due 1 September 1995
Resolved 1 September 1995
Electrical
Issued 25 August 1995 Resolved
PROVE OPERATION OF THE LOW LUBE OIL SHUTDOWN AND OVERSPEED SHUTDOWN ON THE NUMBER 1 GENERATOR.
Condition: Unknown
Due 1 September 1995
Resolved 1 September 1995
Deck/Cargo
Issued 30 August 1993 Resolved
PROVE PROPER OPERATION OF THE STERN THRUSTER IN THE PRESENCE OF THE_x001C_ ATTENDING CG MARINE INSPECTOR.
Condition: Unknown
Due 30 August 1993
Resolved 30 August 1993
Electrical
Issued 13 August 1993 Resolved
PROVIDE COPIES OF APPROVED ELECTRICAL DRAWINGS AND ANY COMMENT LETTERS THATAPPLY FOR THE STERN THRUSTER INSTALLATION. COPIES TO BE SUBMITTED TO MSO HONOLULU. (46 CFR 110.25-3) _x001C_ _x001C_
Condition: Unknown
Due 13 September 1993
Resolved 30 August 1993
Navigation
Issued 13 August 1993 Resolved
PRIOR TO USING THE STERN THRUSTER, DEMONSTRATE FULL OPERATION IN ALL_x001C_ MODES. TEST ALL ALARMS AND INDICATORS FOLLOWING MANUFACTURERS TEST PROCEDURES. (46 CFR 110.30-3)_x001C_ _x001C_
Condition: Unknown
Due 18 August 1993
Resolved 18 August 1993
Documentation
Issued 13 August 1993 Resolved
PROVIDE EVIDENCE OF FCC COMPLIANCE FOR REMOTE RADIO CONTROLLED STERN THRUSTER INSTALLATION._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 18 August 1993
Resolved 18 August 1993
Electrical
Issued 13 August 1993 Resolved
INSTALL NON-CONDUCTIVE MATTING AT THE FOOT OF THE HYDRAULIC MOTOR CONTROL PANELS. (46 CFR 111.30-11)_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 September 1993
Resolved 30 August 1993
Electrical
Issued 13 August 1993 Resolved
MOVE ELECTRIC POWER CABLES UP FROM BETWEEN BILGE STRINGERS ON #1 HYDRAULIC MOTOR. CABLES SHALL BE AS HIGH ABOVE THE BILGES AS POSSIBLE, AND AT LEAST ABOVE THE BOTTOM FRAMES. (NEC, IEEE-45)_x001C_ _x001C_
Condition: Unknown
Due 18 August 1993
Resolved 18 August 1993