Records from 1995 to 2023. Most recent: inspection, 21 August 2023.
Inspection history · 16
21 August 2023
Damage Survey · Deficiency Check
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 7773597
20 July 2023
Damage Survey
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 7748564
24 March 2023
Initial Certification
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 7656179
7 April 2022
Administrative Inspection
Administrative · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 7426323
9 December 2015
Type not recorded
No type recorded · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 5778649
9 December 2015
Industry Initiated Exam
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 5779774
4 December 2015
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 5779828
13 October 2014
Type not recorded
No type recorded · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 5005571
30 August 2014
Type not recorded
No type recorded · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 4973432
1 November 2012
Administration · MARPOL · Industry Initiated Exam
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 4477018
28 November 2006
Type not recorded
No type recorded · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 2831676
18 October 2006
Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2802899
2 December 2001
Type not recorded
No type recorded · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 167470
2 December 2001
Type not recorded
No type recorded · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 1474834
2 December 2001
Type not recorded
No type recorded · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 1485802
3 May 1995
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 159605
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 21 August 2023
Resolved
The vessel has been both in satisfactory service insofar as structural adequacy is concerned and does not cause the structure of the vessel to be questioned by either the OCMI, or TPO engaged to perform an audit or survey. Vessel flooded due to structural failures on the aft void. Structural, mechanical and electrical repairs must be conducted to the satisfaction of the attending Coast Guard inspector prior to commercial operation.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 October 2023
Resolution: vessel scrapped.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 20 July 2023
No resolution recorded
A towing vessel must be maintained and operated so the watertight integrity and stability of the vessel are not compromised. The vessel suffered an unintentional flooding event. All spaces/voids/tanks located on the main deck were flooded. Vessel is to be placed in dry-dock and an examination of the hull condition and scantlings completed.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 July 2023
No resolution recorded
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. The vessels operational condition, to include engineering and electrical components, have been negatively altered/effected due to sinking (submersion). Vessel components must be exercised (i.e., tested) to demonstrate operability.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 March 2023
Resolved
Connections and terminations must be suitable for the installed conductors, and must retain the original electrical, mechanical, flame-retarding, and where necessary, fire-resisting properties of the conductor. Vessel had wires underneath pilothouse console and in engine room that were dead but not properly capped off or removed.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 April 2023
Resolved 30 March 2023
Resolution: Proof was provided that connections were properly terminated.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 March 2023
Resolved
Cable hangers for overhead and vertical cable runs must be installed with metal supports and retention devices at least every 48 inches. Engine room had cable runs secured with plastic zip ties without cable supports and metal braces.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 April 2023
Resolved 5 April 2023
Resolution: Vessel provided proof that deficiency has been rectified.
Fire Fighting › Fire Pumps › Power Source
Issued 9 December 2015
Resolved
Portable Fire pump not operational.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 December 2015
Resolved 14 December 2015
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 9 December 2015
Resolved
Prove proper servicing of B-V fire extinguisher.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 December 2015
Resolved 14 December 2015
Resolution: New Type V purchased and placed on the vessel