Inspection record

Last inspected 2 December 2025
…with no type recorded8
…past their stated due date1
Operational controls None recorded without a removal date
Years with a record 16 calendar years (1992–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDL7977
137100
Flag
UNITED STATES
Maury page id
psix-137100

Documentation record

Registered dimensions (L × B × D)62.4 ft × 24.0 ft × 8.6 ft
Registered tonnagegross 123 / net 83
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderWALL SHIPYARD INC · HARVEY, LA, UNITED STATES · built 1975
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portMEMPHIS, TN
Endorsements, as the file codes themcw_un
DocumentationValid · issued 13 November 2025 · expires 30 November 2026
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it123 - Regulatory (Subpart C or D), Gross Ton
83 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 21 inspections, each with its date, unit and type; 23 deficiencies with the resolution recorded against each, 2 without one; operational controls, none recorded without a removal date; 12 other vessels inspected with it; 1 other recorded name; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 12

Inspection history · 21

2 December 2025 Drydock Extension · Administrative Inspection
Administrative · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 8277771
6 November 2025 COI Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 8261401
2 January 2025 Annual Inspection · Administrative Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 8057049
28 March 2024 Deficiency Check
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 7886486
4 January 2024 Annual Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 7845100
6 February 2023 Annual Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 7632875
7 December 2021 Administrative Inspection · Annual Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 7361874
30 November 2020 Deficiency Check · Administrative Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 7104840
2 October 2020 Initial Certification
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 7074540
6 December 2018 MTSA Verification · Administrative Inspection · Initial Certification
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6592806
19 June 2017 Damage Survey · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6182361
7 November 2016 Deficiency Check · Industry Initiated Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6030558
20 October 2015 Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 5757943
9 October 2014 Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 5055519
16 December 2012 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4505118
19 September 2011 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4151417
23 June 2011 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4202139
13 October 2010 Industry Initiated Exam · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3869291
6 May 2002 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1613978
4 October 2000 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 8577
13 February 1992 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 80872

Deficiency record · 23

02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 6 November 2025 Resolved
Decks and bulkheads designed to be watertight or weathertight must be maintained in that condition. Bulkhead penetration identified on starboard bulkhead, engine room, next to fire pump. Corroded pipe to the exterior of the vessel above the waterline. Cap pipe to prevent water intrusion and make permanent repairs at next scheduled drydock.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 November 2025
Resolution: Capped pipe penetrating the bulkhead.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 November 2025 Resolved
All seals and gaskets must be properly maintained to prevent leaks of flammable or combustible liquid into the machinery space. Minor fuel leak on port main engine fuel governor. Make repairs to stop the leak.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 December 2025
Resolution: Renewed governor. Op test of MDE satisfactory.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 6 November 2025 No resolution recorded
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Port flanking rudder ram seal is leaking. Make repairs to stop the leak prior to departure from drydock, Action Code 705.
Action required: 705 - Other - as specified
Due 6 December 2025 — due date passed with no resolution recorded
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 6 November 2025 Resolved
Electrical components that pose an electrical hazard must be in an enclosure. Potable water pump is missing electrical cover. Make safe by replacing electrical cover.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 December 2025
Resolution: Electrical cover replaced on water pump. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 January 2024 Resolved
Verification of compliance with design standards must include review and analyses of sufficient plans, drawings, schematics, calculations, and other documents to ensure the vessel complies with the standards used. Unauthorized temporary portable generator installed on aft deck with electrical wiring rigged to switchboard in machinery space. Installation of portable generator is not in compliance with verification standards and poses stability, electrical and fire protection risks. Installation must be removed from the vessel.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Resolved 9 January 2024
Resolution: Portable generator removed from the aft deck of the vessel and placed onto the pier.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 January 2024 Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Port Generator inoperable. Repair or renew the port generator, in kind, to restore normal operations by design.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 March 2024
Resolved 28 March 2024
Resolution: Generator was replaced in-kind. All engine alarms were observed. ALL SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 January 2024 Resolved
Each towing vessel must be maintained and operated so as to minimize fire hazards. Port generator fuel supply hose is damaged. Renew fuel supply hose upon the installation of the new port generator.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 March 2024
Resolved 28 March 2024
Resolution: Port generator fuel supply line replaced. ALL SAT.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 8 January 2024 Resolved
There must be an installed or portable bilge pump for emergency dewatering. Installed bilge pump suction and discharge hoses are damaged. Renew ruptured suction hose and renew collapsted discharged hose to restore function of the installed bilge pump.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 8 January 2024
Resolution: Suction and discharge hoses renewed.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 8 January 2024 Resolved
To stop the flow of fuel in the event of a fire or break in the fuel line, a remote fuel shutoff valve must be fitted on any fuel line that supplies fuel directly to a propulsion engine or generator prime mover. Starboard fuel shut off valve is incorrectly configured. The valve handle is missing a stop and when pulled beyond the closed position, continues to move 180 deg. to the open position. Renew valve handle and configure the valve to allow operation from the open position, to the closed position, and no further.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Resolved 8 January 2024
Resolution: Valve handle renewed with a correctly configured component. Valve secured to allow handle to only be pulled from the open position to the closed position and back.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 8 January 2024 Resolved
Piping and machinery components that exceed 220 °C (428 °F), including fittings, flanges, valves, exhaust manifolds, and turbochargers, must be insulated. Measures must be in place to prevent flammable or combustible liquid piping leaks from coming into contact with these components. Exhaust lagging for all operating engines is unsatisfactory. Lagging wrap is not continuous and exposes several sections of hot exhaust piping. Re-wrap exhaust lagging to cover all exposed areas and secure lagging wrap with proper banding to prevent future exposure.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Resolved 8 January 2024
Resolution: Exhaust lagging has been re-wrapped properly and secured with metal banding ties.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 6 February 2023 Resolved
Vessel must be maintained and operated so the watertight integrity and stability of vessel are not compromised. There are two uncapped and wasted 4" pipe nipples penetrating the main deck in the stern void. There is also a 1" pipe nipple penetrating the main deck in the stern void with a hose attached. Hose is serving an submersible pump that is no longer in use. Make effective repairs to ensure watertight integrity of the void.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 10 February 2023
Resolution: Cropped out and inserted deck plating
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 6 February 2023 Resolved
An exposed hazard such as gears and rotating machinery must be protected by a cover, guard or rail. The vibration dampener on both propulsion engines is exposed without any guard.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Resolved 10 February 2023
Resolution: Installed guards.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 6 February 2023 Resolved
Piping and machinery components including turbo chargers and exhaust piping must be insulated. Exhaust piping on both propulsion engines were missing exhaust lagging
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Resolved 10 February 2023
Resolution: Installed lagging.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 6 February 2023 Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Starboard generator engine is inoperable due to faulty fuel injector.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 10 February 2023
Resolution: Replace faulty fuel injector. witnessed operation.
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 6 February 2023 Resolved
Pressure vessels must be fitted with one or more relief valves. The total relieving capacity of such relief valves must prevent pressure from exceeding the maximum allowable working pressure. Relief valves must be tested twice every fire years, not exceeding three years in accordance with 46 CFR 143.245(b). Pressure relief valves serving both air receivers have not been tested as required. Additionally, the relief valve on the port air receiver is set at 325 PSI while the MAWP of the receiver is 200 PSI.
Condition: Placed in Improper Service
Action required: 60 - Rectify deficiencies prior to movement
Resolved 10 February 2023
Resolution: Installed new 200 psi pressure relief valves
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 February 2023 Resolved
To stop flow of fuel in the event of a fire or break in the fuel line, a remote fuel shutoff valve must be fitted on any fuel line that supplies fuel directly to a propulsion engine or generator prime mover. Vessel is equipped with remote fuel valves at the port and starboard holding tank. However to the unique design of vessel's fuel system, using the inline "stripping" tank, closing the remote fuel valves serving the holding tank would not stop the fuel supply to the propulsion engines or generators in a timely manor. Either, install remote fuel shut off valves in the fuel supply line serving each propulsion engine and generator or reconfigure fuel piping system to exclude "stripping" tank.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Resolved 10 February 2023
Resolution: Installed remote shutoff valves serving each MDE and SSDG
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 6 February 2023 Resolved
All bilges and void spaces are to be kept free from accumulation of combustible and flammable materials and liquids insofar as practical. Vessel had excessive oil in engine room bilge.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 10 February 2023
Resolution: Pumped and cleaned bilge
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 February 2023 Resolved
All seals and gaskets must be properly maintained to prevent leaks of flammable or combustible liquid. Starboard propulsion engine fuel pump has fuel leak.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 10 February 2023
Resolution: Replaced fuel pump
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 6 February 2023 Resolved
Each towing vessel must have reliable means to provide notification when an emergency condition exists or an essential system develops a problem that requires attention. the following alarms must be provided. Propulsion and generator low lube oil pressure and high cooling water temperature, high bilge level, low hydraulic steering fluid level. Additionally alarm setpoints must be tested twice within every 5 years, not to exceed 3 years in accordance with table 46 CFR 143.245. Vessel crew could not test engine alarms. Vessel's engine alarm system does not meet configuration requirements listed in 46 CFR 143.230. Install alarm panel meeting requirements and have alarms tested by marine inspector.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 March 2023
Resolved 16 March 2023
Resolution: Tested all required alarms.
09 - Working and Living Conditions › 091 - Living Conditions › Access/structure
Issued 6 February 2023 No resolution recorded
A crew accommodation space and a work space must be of sufficient size, adequate construction, and with suitable equipment to provide for the safe operation of the vessel and the protection and accommodation of the crew in a manner practicable for the size, facilities, service, route, and modes of operation of the vessel. Deck in crew head is wasted to the point that it has holes in it. Condition of deck is a safety hazard to the crew. Vessel is authorized to conduct temporary repair using epoxy. Steel deck must be cropped out and renewed at next schedule dry dock in 2025.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 9 November 2020 Resolved
A towing vessel must ensure that the vessel's lifesaving & fire suppression & detection equipment complies with the applicable requirements of this subchapter and is in good working order. The vessel's fixed fire pump has a minor leak through the plug and must be rectified within 90 days. 705(c) *see narrative for additional information.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 February 2021
Resolved 30 November 2020
Resolution: Company POC provided photo evidence that the pump plug was replaced and no longer leaking.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 November 2020 Resolved
Machinery & electrical systems must be designed & maintained to provide for safe operation of the towing vessel & safety of persons onboard under normal & emergency conditions. There were a few locations where dead end wiring and missing junction box covers were observed. These areas need to be rectified within 90 days. 705 (c)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 February 2021
Resolved 30 November 2020
Resolution: The Company POC provided photographic evidence that the junction box and battery covers were in place as required.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 9 November 2020 Resolved
Propulsion machinery, including main engines, reduction gears, shafting, bearings, & electrical equipment & systems must be maintained to ensure proper operation. The coolant water piping on the vessel's generator was very loose and could lead to a potential failure of the coolant system. This issue needs to be rectified within 90 days. 705(c)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 February 2021
Resolved 30 November 2020
Resolution: The Company POC provided photographic evidence that the coolant water piping on the generator was properly secured to prevent movement.

Recorded names · 1

HALEY BROOKE (2012–2015). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.