Records from 2015 to 2026. Most recent: inspection, 13 January 2026.
Documentation record
Registered dimensions (L × B × D)390.1 ft × 74.0 ft × 26.5 ft
Registered tonnagegross 6,115 / net 6,115
ITC dimensions (L × B × D)390.1 ft × 74.0 ft × 26.5 ft
ITC tonnagegross 7,205 / net 4,935
BuilderSENESCO MARINE · North Kingstown, RI, UNITED STATES · built 2016
Hull materialSteel
PropulsionNot recorded
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW YORK, NY
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 10 September 2025 · expires 31 October 2026
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it7205 - Convention (Subpart B), Gross Ton
6115 - Regulatory (Subpart C or D), Gross Ton
4935 - Convention (Subpart B), Net Ton
6115 - Regulatory (Subpart C or D), Net Ton
14328 - Dead Weight, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 27
13 January 2026
Bulk Liquid Transfer Monitor
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8295845
13 May 2025
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8134754
8 May 2025
Bulk Liquid Transfer Monitor
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8140515
11 September 2024
Administrative Inspection · Periodic Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8000916
19 January 2024
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7851770
12 December 2023
Administrative Inspection · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7837944
3 August 2023
Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7759348
1 July 2023
Bulk Liquid Transfer Monitor
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7728086
29 August 2022
Annual Inspection · MTSA Verification
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7544235
7 December 2021
Bulk Liquid Transfer Monitor
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7363727
28 September 2021
Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 7322391
26 April 2021
Examination of Repairs · Internal Structural Exam · Drydock Exam · COI Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7154065
30 November 2020
Appeal
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7115102
8 October 2020
Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7073722
10 August 2020
Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 7029049
14 July 2020
Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 7007647
27 February 2020
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6917009
15 October 2019
Annual Inspection · MARPOL Annex II Examination · MARPOL Annex VI Survey · MARPOL Annex I Examination · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6834422
3 September 2019
Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit New Bedford · USCG Northeast District (CGD-NE) · Activity 6802538
5 March 2019
Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6636819
10 January 2019
Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6608753
10 July 2018
MTSA Verification · Periodic Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6473856
5 September 2017
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6260056
18 August 2017
Annual Inspection · MARPOL Annex II Examination · MARPOL Annex IV Survey · MARPOL Annex I Examination · MTSA Verification · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6244392
10 March 2017
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6102621
18 November 2016
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6043782
17 August 2015
MTSA Verification · Construction Oversight · Initial Certification · MARPOL Annex VI Survey · COI Inspection · MARPOL Annex I Examination
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5840474
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 8 October 2020
Resolved
Each vessel must carry a category 1 406 MHz satellite EPIRB meeting the requirements of 47 CFR part 80.
Vessel is on an Oceans International route and does not have an EPIRB on board.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 November 2020
Resolved 20 May 2022
Resolution: Converted to Special Note. Appeal pends.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 8 October 2020
Resolved
Each inflatable liferaft must be approved under approval series 160.151 and be equipped with a SOLAS A pack.
Vessel is currently carrying an IBA and not an approved liferaft. Vessels need to carry an approved liferaft.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 November 2020
Resolved 15 June 2021
Resolution: 6 Man Solas A life raft installed port stern
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 10 July 2018
Resolved
Vacuum side of PV valves were painted over and therefore unable to draw suction.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 10 July 2018
Resolved 10 July 2018
Resolution: Crew cleared paint and ensured proper function.
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 20 July 2016
Resolved
Porperly label VCS line.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 July 2016
Resolution: Vessels VCS piping was properly painted and labeled IAW CFR.
Electrical › Electric Generation Source (service) › Power Requirement
Issued 20 July 2016
Resolved
Provide proper datat plate for both generators. (Temperature Rating)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 July 2016
Resolution: Vessel recieved and installed proper data plates on each generator, reflecting proper temp rating of 50 degrees C.
Documentation › Markings/Placards › Warning Signs
Issued 20 July 2016
Resolved
Properly install spill kit and placarding.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 July 2016
Resolution: Vessel installed proper spill kit in accordance with SOPEP plan, all markings and warning signs were permanently stenciled IAW CFR.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 20 July 2016
Resolved
Properly install B-5 Exstinguishers at proper location IAW FSP.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 July 2016
Resolution: Vessel installed all fire exstinguishers IAW approved FSP.
Lifesaving › Lifebuoys › Stowage
Issued 20 July 2016
Resolved
Prove proper installation of all LSA arrangments after painting is complete.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 July 2016
Resolution: Installed all LSA equipment IAW General Arrangments Plan and amount IAW signed COI.