Records from 2016 to 2026. Most recent: inspection, 2 March 2026.
Documentation record
Registered dimensions (L × B × D)40.0 ft × 14.0 ft × 3.5 ft
Registered tonnagegross 9 / net 9
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCORINTHIAN CATAMARANS LLC · TARPON SPRINGS, FL, UNITED STATES · built 2016
Hull materialFRP (Fiberglass)
PropulsionGasoline Outboard
Hull shapeShip
Hull configurationTwin Hull
Hailing portHARKERS ISLAND, NC
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 26 August 2025 · expires 30 September 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it9 - Simplified, Gross Ton
9 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 24
2 March 2026
COI Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8314223
14 January 2026
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8294627
31 August 2025
Damage Survey
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8221365
20 August 2025
Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8354042
27 February 2025
Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8081370
8 February 2024
Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7861689
10 January 2024
Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7847477
21 February 2023
Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7639281
28 February 2022
Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7402913
22 February 2022
Deficiency Check · Hull Examination
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7399659
25 March 2021
COI Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7160778
17 February 2021
Administrative Inspection
Administrative · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7141863
17 March 2020
Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6924070
4 March 2020
Hull Examination
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6923715
28 July 2019
Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6837087
14 May 2019
Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6677780
5 May 2019
Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6680982
5 April 2019
Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6685471
1 August 2018
Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6504449
23 April 2018
Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6394540
16 April 2018
Administrative Inspection · Hull Examination
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6392185
16 March 2017
Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6100879
9 June 2016
Administrative Inspection · Initial Certification · COI Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 5902062
7 April 2016
Hull Examination · Construction Oversight · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5853424
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 February 2022
Resolved
At each subsequent inspection of each portable fire ext its to check for excessive corrosion and general condition. Both fire ext were rusted and corroided. Replace both fire ext in kind.
Action required: 705 - Other - as specified
Due 22 March 2022
Resolved 28 February 2022
Resolution: Vessel replaced all fire ext with in kind. All SAT.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 22 February 2022
Resolved
A vessel is inspected for compliance with the standards required by this subchapter. Port and STBD deck access has fiberglass failure and cracking. Make proper repairs to the areas for the attending MI.
Action required: 705 - Other - as specified
Due 22 March 2022
Resolved 28 February 2022
Resolution: Vessel conducted repairs IAW manufactures specs. All SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 22 February 2022
Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and purpose intended. M/I's discovered missing lower unit bolt on STBD outboard. Install new in kind bolt.
Action required: 705 - Other - as specified
Due 22 March 2022
Resolved 28 February 2022
Resolution: Vessel installed new in kind bolt. All SAT.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 30 March 2021
Resolved
Properly secure anchor light.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2021
Resolved 5 April 2021
Resolution: The light was properly secured with a screw.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 30 March 2021
Resolved
Provide original certificate of documentation onboard the vessel.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2021
Resolved 6 May 2021
Resolution: Owner provided objective evidence the COD was renewed and onboard the vessel satisfying the requirement.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 30 March 2021
Resolved
Portside main engine rigging tube is broken and rubbing on fuel hose. Re-attach or renew.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2021
Resolved 5 April 2021
Resolution: The rigging tube was properly re-attached.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 March 2021
Resolved
Make permenant connections on all battery wire connectors (ny-lock or lock washers)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2021
Resolved 5 April 2021
Resolution: Lock washers were added to the nuts to make permenant connection.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 30 March 2021
Resolved
Found one adult lifejacket un-servicable.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 30 March 2021
Resolved 30 March 2021
Resolution: Life jacket was replaced with new.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 14 May 2019
Resolved
Replace damaged (cracked) port and starboard steering lines as discussed in kind. Meeting testing standards iaw SAE J-1942.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 May 2019
Resolved 14 June 2019
Resolution: Completed to the satisfaction of the attenting inspector.