Records from 2016 to 2026. Most recent: inspection, 10 June 2026.
Inspection history · 18
10 June 2026
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8395785
22 May 2025
Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8144935
1 April 2025
Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8104521
25 June 2024
Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7929187
24 May 2023
COI Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7690302
28 April 2023
Administrative Inspection · Hull Examination
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7677212
25 August 2022
Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7584422
24 August 2022
Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7543647
27 June 2022
COI Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7467288
24 September 2021
Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7342144
29 March 2021
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7160745
12 February 2021
Hull Examination · Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7139993
18 March 2020
Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6928666
17 April 2019
Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6659447
5 April 2019
Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6685471
25 March 2019
Hull Examination · Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6647177
21 June 2018
Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6451486
15 March 2016
Initial Certification · Administrative Inspection · Initial Construction-Excluding Oversight · Hull Examination
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 5833382
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 10 June 2026
Resolved
The frame or support of each semi-portable fire extinguisher permitted by paragraph (a) of this section must be welded or otherwise permanently attached to a bulkhead or deck.
Place fire extinguisher in approved bracket and secure to deck or bulkhead.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2026
Resolved 15 June 2026
Resolution: New extingusiher bracket mounted to bulkhead. All sat.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 28 April 2023
Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and internal structural examination at least once every two years. The vessel is overdue for its required drydock and internal structural examination and must be completed prior to the carriage of passengers.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 May 2023
Resolution: Drydock exam conducted this day.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 27 June 2022
Resolved
Table 181.500 (b) of this section indicates the minimum required classification for each space listed. Vessel is missing 40:BC IAW COI. Install new 40:BC.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 July 2022
Resolution: Owner installed new 40:BC fire ext. All SAT
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 June 2022
Resolved
Each vessel must be equipped with at least two operable portable battery lights. Vessel only has one. Provide additional light.
Action required: 705 - Other - as specified
Due 4 July 2022
Resolved 8 July 2022
Resolution: Owner installed two new battery flashlights. All SAT
05 - Radio Communications › N/A - No Subsystem › Functional requirements
Issued 27 June 2022
Resolved
Stations in the maritime service must be licensed by the FCC either individually or by the fleet. Vessels safety radio telephony cert is expired. provide valid cert.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 July 2022
Resolved 8 July 2022
Resolution: Owner provided proof of new valid FCC Certificate. All SAT.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 27 June 2022
Resolved
Rail courses on passenger decks of a ferry must be installed (i) bulwarks; (ii) chain link fencing or wire mesh that has openings of not more than 4 inches in diameter; or bars; or slats, rail or on equivalent spaced at intervals of not more than 4 inches. no equivalent provisions provided on vessel IAW embarkation openings.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 July 2022
Resolved 8 July 2022
Resolution: Owner removed exisitng wire rope set up and installed a netting system that meets the requirements in 46CFR177. All SAT.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 29 March 2021
Resolved
Add missing secondary ring buoy per conditions of certificate of inspection.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 April 2021
Resolved 30 March 2021
Resolution: Witnessed satisfactory this date and considered cleared to the satisfaction of the attending inspector.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 29 March 2021
Resolved
Tighten loose fuel line clamps on tank.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Due 29 March 2021
Resolved 30 April 2021
Resolution: Witnessed satisfactory this date and considered cleared to the satisfaction of the attending inspector.
04 - Emergency Systems › N/A - No Subsystem › Location of emergency installations
Issued 29 March 2021
Resolved
Tighten loose bilge hose clamps.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Due 29 March 2021
Resolved 30 April 2021
Resolution: Witnessed satisfactory this date and considered cleared to the satisfaction of the attending inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 29 March 2021
Resolved
Secure both marine batteries and boxes.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 29 March 2021
Resolved 30 April 2021
Resolution: Witnessed satisfactory this date and considered cleared to the satisfaction of the attending inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 29 March 2021
Resolved
Replace or repair fuel gauge on tank.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 April 2021
Resolved 30 April 2021
Resolution: Witnessed satisfactory this date and considered cleared to the satisfaction of the attending inspector.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 29 March 2021
Resolved
Repair cracks on the T-top and port fwd hand rail.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 April 2021
Resolved 26 April 2021
Resolution: Accepted objective evidence from operator the welding had been carried out.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 29 March 2021
Resolved
Tighten loose hand rails.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 April 2021
Resolved 30 April 2021
Resolution: Witnessed satisfactory this date and considered cleared to the satisfaction of the attending inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 29 March 2021
Resolved
Prove proper operation of kill switch.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Due 29 March 2021
Resolved 30 April 2021
Resolution: Witnessed satisfactory this date and considered cleared to the satisfaction of the attending inspector.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 29 March 2021
Resolved
Install the forward rope/wire run to hand rails.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Due 29 March 2021
Resolved 30 April 2021
Resolution: Witnessed satisfactory this date and considered cleared to the satisfaction of the attending inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 16 February 2021
Resolved
Re-attach bilge pump
Action required: 705 - Other - as specified
Resolved 17 February 2021
Resolution: The bilge pump was properly secured in the bilge well.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 16 February 2021
Resolved
Re-glass engine cowling or replace
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 17 February 2021
Resolution: The cowling was replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 18 March 2020
Resolved
Replaced damaged life jacket. Restricted to 18 Adults.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 18 March 2020
Resolved 22 March 2020
Resolution: Received, reviewed, and accepted objective evidence satisfying the requirement.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 18 March 2020
Resolved
Post missing donning and emergency instructions.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 March 2020
Resolved 22 March 2020
Resolution: Received, reviewed, and accepted objective evidence satisfying the requirement.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 17 April 2019
Resolved
CAPT could not provide radio operators permit when asked.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 April 2019
Resolution: CAPT sent photo via text to [name withheld].
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 April 2019
Resolved
No approved First Aid Kit onboard, new kit is not approved by CG.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 April 2019
Resolution: New approved kit provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 April 2019
Resolved
04 Audult and 02 Child life jackets damaged due to U/V damage. Limited to 18 Adult and 2 Child
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 19 April 2019
Resolution: New lifejackets provided. With proper markings.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 17 April 2019
Resolved
Anchor light not working. Limited to day light hours only
Action required: 705 - Other - as specified
Resolved 19 April 2019
Resolution: All nav lights working.