Records from 1994 to 2025. Most recent: inspection, 8 September 2025.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 8 September 2025
No resolution recorded
A towing vessel may not be operated without having onboard a valid COI issued by the Coast Guard as required by 136.202. Vessel COI expired 09SEPT2025. Vessel must complete DD and COI Inspection prior to operating.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 13 March 2025
Resolved
Vessel reported it was taking on water in the starboard void. Vessel pulled out at Steiner Shipyard for repairs. Provide repair proposal to sector Mobile for review and approval prior to any repairs made to the vessel.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 March 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 November 2024
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. MI observed a cracked air intake elbow on the port main diesel engine's turbo.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 20 November 2024
Resolved 3 December 2024
Resolution: Vessel crew replaced air intake elbow on the port main diesel engine turbo.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 November 2024
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. MI observed soot covered exhaust lagging on the starboard main diesel engine's exhaust piping, there is potential of a exhaust leak. MI could not investigate due to location. Crew is to investigate and report findings to the Coast Guard.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 December 2024
Resolved 3 December 2024
Resolution: Vessel found a broken exhaust pipe mounting bracket causing an exhaust leak. Vessel replaced bracket and repaired exhaust leak. New exhaust lagging was installed.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 12 October 2023
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Hydraulic hose for steering ram is worn through to the metal braiding.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 October 2023
Resolved 26 October 2023
Resolution: Received objective evidence from POC.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 October 2023
Resolved
The frame or support of any semi-portable fire extinguisher fitted with wheels must be welded or otherwise permanently attached to a steel bulkhead or deck to prevent it from rolling under heavy sea conditions. Semi portable fire extinguisher in upper engine room is secured by chain to the hand rail. A more permanent attachment method is needed.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 October 2023
Resolved 26 October 2023
Resolution: Received objective evidence from POC.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 October 2023
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard. Overhead light on FWD main deck has electrical wires hanging out of enclosure and lamp cover is broken.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 October 2023
Resolved 26 October 2023
Resolution: Received objective evidence from POC.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 October 2023
Resolved
Each towing vessel must perform the applicable tests in Table 143.245(b) of this section. The tests required by this section must be recorded in accordance with part 140 of this subchapter. Engine alarm set point records were unable to be produced. Provide record of tests.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 October 2023
Resolved 11 January 2024
Resolution: Test conducted record retained.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 12 October 2023
Resolved
The original COI must be framed under glass or other transparent material and posted in a conspicuous place onboard the towing vessel. All individual pages of the COI were not posted.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 October 2023
Resolved 26 October 2023
Resolution: Received objective evidence from POC.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 12 October 2023
Resolved
The sidelights of vessels of 20 meters or more in length shall be fitted with matte black inboard screens. Sidelights had gloss black paint. Repaint with matte black paint.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 October 2023
Resolved 11 January 2024
Resolution: Painted matte black.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 October 2023
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Water pipe from potable water tank in lower forward engine room was leaking water into the engine room.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 October 2023
Resolved 26 October 2023
Resolution: Received objective evidence from POC.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 12 October 2023
Resolved
Emergency lighting must be provided for all internal crew working and living areas. Emergency lighting sources must provide for sufficient illumination under emergency conditions to facilitate egress from each space. Crew cabins had no methods of illuminating egress routes or exits for night time emergencies.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 October 2023
Resolved 11 January 2024
Resolution: Photoluminescent tape installed.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 12 October 2023
Resolved
Means to stop fans and close openings. Means must be provided for closing, in case of fire in such spaces. Engine room vent on port side was unable to be fully closed.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 October 2023
Resolved 26 October 2023
Resolution: Received objective evidence from POC.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 12 October 2023
Resolved
Rails or equivalent protection must be installed near the periphery of all decks accessible to crew. There were no rails or protection installed around the aft of the vessel where the aft steering deck is level with the top rail of the vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 November 2023
Resolved 11 January 2024
Resolution: Handrails and chains installed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 12 October 2023
Resolved
Bilge pumps or other dewatering capability. There must be an installed or portable bilge pump for emergency dewatering. Any portable pump must have sufficient hose length and pumping capability. All installed bilge piping must have a check/foot valve in each bilge suction that prevents unintended backflooding through bilge piping. Crew was unable to start the portable bilge pump in a timely manner.
Action required: 10 - Deficiency Rectified
Due 12 October 2023
Resolved 12 October 2023
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 12 October 2023
Resolved
The master must ensure that all hatches, doors, and other openings designed to be watertight or weather-tight function properly. Seal on the #2 void was missing on the void cover.
Action required: 10 - Deficiency Rectified
Due 12 October 2023
Resolved 12 October 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 12 October 2023
Resolved
The master must ensure that all lifesaving equipment is properly maintained and ready for use at all times. Lifering light on port side was inoperable due to a missing battery.
Action required: 10 - Deficiency Rectified
Due 12 October 2023
Resolved 12 October 2023
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 12 October 2023
Resolved
Each towing vessel must be equipped with an industrial type first aid cabinet or kit, appropriate to the size of the crew and operating conditions. Vessel's first aid kit had expired contents onboard.
Action required: 10 - Deficiency Rectified
Due 12 October 2023
Resolved 12 October 2023
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 12 October 2023
Resolved
Storage areas must be kept free from accumulation of combustible and flammable materials insofar as practicable. Main deck head contained flammable materials.
Action required: 10 - Deficiency Rectified
Due 12 October 2023
Resolved 12 October 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 October 2023
Resolved
Lifebuoys must have the following attachments and fittings: At least one lifebuoy must have a lifeline, secured around the body of the lifebuoy. If more than one lifebuoy is carried, at least one must not have a lifeline attached. All liferings had an attached rope.
Action required: 10 - Deficiency Rectified
Due 12 October 2023
Resolved 12 October 2023
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 12 October 2023
Resolved
The master must ensure that all hatches, doors, and other openings designed to be watertight or weather-tight function properly. #2 void had water approximatly 6" above the bottom frames. Instructed crew to comprise a monitoring plan to troubleshoot ingress of water.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 February 2024
Resolved 26 January 2024
Resolution: Received and reviewed objective evidence to satisfy requirement.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 28 September 2022
Resolved
Excessive leaking of shaft packing.
Action required: 10 - Deficiency Rectified
Resolved 28 September 2022
Resolution: Packing was tightened on the spot.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 28 September 2022
Resolved
Louvers on exhaust ports did not have a means of closing completely.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 October 2022
Resolution: Latches were installed on exhaust ports.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 28 September 2022
Resolved
Repair work around stbd shaft alley was missing a weld.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 October 2022
Resolution: Observed all welds SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 September 2022
Resolved
Steering gear was missing chafing gear around hydraulic hoses and hoses were not mounted in designed brackets.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 October 2022
Resolution: Observed chafing gear in place and hoses mounted in brackets.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 September 2022
Resolved
Electrical connection to battery in engine room was loose.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 October 2022
Resolution: Observed no loose connections.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 28 September 2022
Resolved
01 lifejacket was found without an approved light. Total number of persons onboard reduced to 05 until rectified.
Action required: 705 - Other - as specified
Resolved 6 October 2022
Resolution: Observed all lifejackets with lights, all SAT.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 28 September 2022
Resolved
A heat sensor was unsecured from the overhead in the engine room. Sensor was reattached.
Action required: 10 - Deficiency Rectified
Resolved 28 September 2022
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 28 September 2022
Resolved
The PE letter for the fire detection system was missing.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 October 2022
Resolved 26 October 2022
Resolution: Company submitted electronic copy of PE letter, see Deficiency Documents.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 23 November 2021
Resolved
Vessel was undergoing a dockside yard period and not ready for annual inspection. Multiple deficiencies were noted and vessel issued no-sail 835 to complete satisfactory annual inspection prior to operation.
Action required: 17 - Rectify deficiencies prior to departure
Due 7 December 2021
Resolved 22 March 2022
Resolution: Annual completed
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 23 November 2021
Resolved
Fire main piping in engine room was found rusted and leaking. Replace wasted piping.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 4 April 2022
Resolved 22 March 2022
Resolution: Piping was replaced. Conducted satisfactory hydro of new piping.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 November 2021
Resolved
hydraulic hoses for steering gear were found dry rotted and cracked. Replace hoses.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 April 2022
Resolved 22 March 2022
Resolution: Hoses were replaced and verified leak free.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil and oily mixtures from machinery spaces
Issued 23 November 2021
Resolved
Excessive oil/water and debris was noted in bilge. Clean bilge
Action required: 17 - Rectify deficiencies prior to departure
Due 4 April 2022
Resolved 22 March 2022
Resolution: Bilges were cleaned of oil/water and debris.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 23 November 2021
Resolved
Galley watertight door failed chalk test. Adjust door to make watertight.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 April 2022
Resolved 22 March 2022
Resolution: Door was properly adjusted and passed chalk test.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 23 November 2021
Resolved
Vessel call sign was changed due to new ownership, but the Call Sign was not changed in AIS or on COI.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 April 2022
Resolved 22 March 2022
Resolution: AIS was updated with correct call sign. COI was amended with correct call sign.
09 - Working and Living Conditions › 091 - Living Conditions › Sleeping room
Issued 23 November 2021
Resolved
Vessel is certificated for 6 persons. Vessel only had 4 mattresses. Provide additional mattresses or reduce passenger count.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 April 2022
Resolved 22 March 2022
Resolution: Two additional mattresses were provided.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 23 November 2021
Resolved
Frames around stbd stuffing box for shaft were found wasted. Repair at next drydock but no later than September 2022.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 September 2022
Resolved 28 September 2022
Resolution: Attended vessel and observed renewed frames and bulkhead around shaft alley.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 9 September 2020
Resolved
All fire suppression equipment must be maintained in accordance with manufacturers instructions. MI noted broken nozzle on fire extinguisher in engine room.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 September 2020
Resolution: Recieved objective evidence of 835 close outs (see docs)
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 9 September 2020
Resolved
Frame or support of semi portable fire extinguishers fitted with wheels must be permanently attached to steel bulkhead or deck to prevent from rolling. MI noted semi portable secured by zipties.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 September 2020
Resolved 10 September 2020
Resolution: Recieved objective evidence of 835 close outs (see docs)
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 September 2020
Resolved
Electrical systems must be designed and maintained to provide for safe operation of the vessel and safety of persons onboard. MI noted exposed electrical wires above oven.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 September 2020
Resolution: Recieved objective evidence of 835 close outs (see docs)
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 9 September 2020
Resolved
Flammable/combustible products onboard must be stored in a designated storage room or cabinet when not in use. MI noted flammable/combustibles stowed on open deck.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 September 2020
Resolution: Recieved objective evidence of 835 close outs (see docs)
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 11 December 2019
Resolved
Decks & bulkheads designed to be watertight
must be maintained in that condition. Before the vessel is permitted to operate under its own power as a Subchapter M regulated towing vessel, vessel must repair the following structural issues & have them inspected / tested by a Marine Inspector:
1) Stern void: Found Transverse deck stiffener not attached to deck plating and wasted over last 30" on the port side. Vertical stiffeners (x2) on fwd (engine room) bulkhead in way of new insert wasted over the bottom 2'. Crop wasted sections and renew.
2) #7 Port wing void: Found Fwd vertical stiffener wasted. Fwd bulkhead holed and patched with putty. Knuckle and fwd bulkhead inset upward 5-6" from bottom. Crop damaged area and renew.
3) Port bow void: Found aft bulkhead buckled and patched. Aft 1/3 of swash bulkhead wasted. Aft two vertical stiffeners on swash bulkhead wasted. Aft two stiffeners on tranverse bulkhead wasted. Inboard wasted/crushed 4-5' from overhead. Crop damaged area and renew.
4) Stbd bow void: Aft bulkhead / sideshell / transverse bottom frame crushed upward from bottom. Crop & Renew.
(5) #1 Stbd Wing Void: Found top of inboard longitudinal bulkhead / deck above both holed. Entire longitudinal swash bulkhead wasted / buckled. As marked: Two vertical sideshell stiffeners, three overhead deck stiffeners, and three bottom longitudinals excessively wasted. Crop and renew.
(6) #2 Stbd Wing Void: Found wasted 2' section of deck stiffener (aft of scuttle) wasted. Crop and renew or replace member.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 December 2019
Resolved 22 April 2020
Resolution: Satisfactory repairs observed. See MISLE narrative.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 December 2019
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Electrical equipment and electrical cables must be suitably protected from wet and corrosive environments.
In bow void, found distribution panel with exposed circuits and cabling runs were not supported to keep it out of wet environment or prevent shock. Properly secure distribution panel / electrical cabling.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 December 2019
Resolved 30 June 2020
Resolution: All electrical hazards in bow void were mitigated with proper electrical connections and securing of all cabling.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 11 December 2019
Resolved
Piping and tanks exposed to the outside of the hull must be made of metal and maintained in a leak free condition. Found sink drain elbow wasted. Found Washing Machine drain wasted. Renew affected piping sections.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 December 2019
Resolved 22 April 2020
Resolution: Piping renewed and positive control means over valve placed.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 27 November 2019
Resolved
Each towing vessel must be maintained to ensure all bilges and void spaces are kept free from accumulation of combustible/flammable materials and liquids insofar as practicable. Found excessive (4-6”) accumulation of oily water in bilge to include overall condition of machinery space was substandard. Excess oily water inhibited ability to test functionality of bilge alarms; note, bilge alarms were not alarming in operating station. Remove oily water by transferring to an approved oil reception facility. In addition, remove submersed/excess debris in bilges to include paint cans, filters, spray paint cans, and oily rags. Provide evidence of transfer to an attending USCG Marine Inspector. 46CFR142.200 30c
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 2 December 2019
Resolution: Vessel offloaded oily bilges to approved oil reception facility.
09 - Working and Living Conditions › 092 - Working Conditions › Fitness for duty - work and rest hours
Issued 27 November 2019
Resolved
The officers and crew are permitted to be divided into two watches when at sea on a voyage of <600 miles on a towing vessel. Found vessel master could not produce medical card/certificate. Also found that vessel was about to embark on a seagoing voyage from New Orleans, LA to Dauphin Island, AL short one deckhand. Provide adequate crew for intended voyage. 46CFR15.705(b) (30c)
Action required: 30 - Ship detained
Resolved 30 June 2020
Resolution: Vessel provided properly certified Master, Mate Pilot, and Deckhands adequate for the intended voyage.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 27 November 2019
Resolved
All fire detection equipment on board a towing vessel must be maintained IAW manufacturers approved design manual. Found fire detector system is inoperable in E/R. Provide evidence of repair and testing from an approved servicing facility. 46CFR142.240(b) (30c)
Action required: 30 - Ship detained
Resolved 30 June 2020
Resolution: Verified system was certified by PE, and tested by an approved 3rd party on 6/14/2020.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 November 2019
Resolved
Electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard. Found multiple electrical hazards: proper interlock for generator switchboard missing, electrical box for inverter ammeter/voltmeter unsupported, open access to upper E/R receptacle box and lower E/R STBD distribution panel, dead end/uncapped wiring under wheelhouse console. Repair/Replace to satisfaction of attending USCG Marine Inspector. 46CFR143.205(a) (30c)
Action required: 30 - Ship detained
Resolved 21 July 2020
Resolution: Dead-end wiring in pilothouse and engine room have been capped.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 27 November 2019
Resolved
The master must ensure all hatches, doors, and openings designed to be watertight or weathertight function properly. Door openings to galley and E/R were not watertight because of punctures in knife edge weldments. All of these doors are missing gaskets, making them ineffective. Multiple flush mounted void hatches observed inoperable to close. Repair to satisfaction of attending USCG Marine Inspector. 46CFR140.610(b) (30c)
Action required: 30 - Ship detained
Resolved 22 April 2020
Resolution: #1P, #1 stbd, #4 stbd, #5 stbd, and bow hatches all satisfactory repaired. E/R doors framing repaired.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 27 November 2019
Resolved
Bulkheads designed to be watertight must be maintained in that condition. Noted water ingress in aftermost STBD wing void bulkhead. Of note, adjacent stern void has considerable corrosion. Determine cause of water ingress and make repairs to satisfaction of attending USCG Marine Inspector. 46CFR140.610(f) (30c)
Action required: 30 - Ship detained
Resolved 22 April 2020
Resolution: Adequate repairs were made, and were inspected and tested to the satisfaction of attending USCG MI's.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 27 November 2019
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Identified excessive shaft leakage on port propulsion shaft with rigged means of dewatering with pumps to maintain leakage, creating a serious substandard condition not being pro-actively managed by the Company, vessel owner, and/or operator. 46CFR143.205(b) (30c)
Action required: 30 - Ship detained
Resolved 30 June 2020
Resolution: Both shaft seal installations were inspected under load and found to be in satisfactory condition.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 27 November 2019
Resolved
The responsibilities of the master and crew are outlined throughout Subchapter M regulations. MI observed master and crew are unfamiliar with the requirements of Subchapter M and the overall safety management system (HELM) utilized for record keeping and hosting shipboard plans. Company to provide Corrective Action Plan to attending Marine Inspector. 46CFR140.210 (30c)
Action required: 30 - Ship detained
Resolved 21 July 2020
Resolution: HELM system implemented and crew knowledgeable for future use.
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 27 November 2019
Resolved
Each towing vessel must be equipped with a marine radar. Vessel’s installed radar would not show transit mode display or required functionality. Provide evidence of repair by a licensed technician. 46CFR140.710 / 33CFR164.72(a)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 30 June 2020
Resolution: Conducted satisfactory operational test of radar.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 27 November 2019
Resolved
Each exhaust pipe from an internal combustion engine which is within reach of personnel must be insulated or otherwise guarded to prevent burns. Exhaust lagging on Port SSDG is missing 3-4’ of lagging. 46CFR144.830(60c)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 21 July 2020
Resolution: Lagging installed on both mains and both generators.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 27 November 2019
Resolved
A 40-B portable fire extinguisher must be located near the storage room or cabinet. This is in addition to the portable fire extinguishers required by tables 142.230 (a) and 142.230(b) of this part. Found no fire extinguisher near the flammable locker, although extra B-II's were located throughout the vessel, provide one near each flammable locker not of UL1275 approved. 46CFR142.225 (60 c)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 21 July 2020
Resolution: Flammable storage has been consolodated and dedicated extinguishers are present.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 27 November 2019
Resolved
Drills must take place on board the towing vessel as if there were an actual emergency; they must include testing of all alarm and detection systems by operation of the test switch or by activation of one or more devices. Upon asking the crew to test the fire detection system, crew indicated they did not have the proper equipment on board to test the heat detectors adjacent to the engines and generators. Per the fire detection system manual, provide the proper equipment to test the alarm and detection system, and incorporate testing into monthly fire drills as required. 46CFR140.210 (60 c)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 21 July 2020
Resolution: Vessel acquired tools for testing (heat gun), tested system and labeled zones.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Resources and personnel
Issued 27 November 2019
Resolved
Prior to getting underway for the first time on a particular towing vessel, each crewmember and non crewmembers must receive a safety orientation and training shall be documented in the TVR, official logbook, or IAW SMS. Observed safety orientation training was not being conducted. Provide training for onboard crew and non crewmembers and document prior to movement. 46CFR140.410 (60c)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 30 June 2020
Resolution: Proper safety orientation of embarking crew was carried out and documented per TSMS.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 November 2019
Resolved
A towing vessel must carry lifebuoys that meet 141.360. Identified aft main deck lifebuoy with deteriorated corrosion-resistant clip and STBD main deck lifebuoy with a deteriorated lifeline and corrosion-resistant clip. 46CFR141.360(c). (60c)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 21 July 2020
Resolution: Ring buoy lines and lights have been replaced, corrosion ressitant clips used.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 27 November 2019
Resolved
Means must be provided for stopping each fan in a ventilation system serving machinery spaces and for closing, in case of fire, each doorway, ventilator, and annular space around funnels and other openings into such spaces. Observed Port exhaust damper holed and not functioning as designed. Replace to satisfaction of attending USCG Marine Inspector. 46CFR144.605 (16c)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 July 2020
Resolution: (4) engine room dampers have been replaced and tested.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 27 November 2019
Resolved
The following minimum information is required in the towing gear inspection record: The dates when examinations were performed, the identification of each item of towing gear examined, and the name(s) of the person(s) conducting the examinations. Towing gear
inspection logs did not contain all required items. 46CFR140.820(b) (16c)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 June 2020
Resolution: Company revised logs to correlate to TSMS and were in the process of conducting inspection of gear.
09 - Working and Living Conditions › 092 - Working Conditions › Obstruction/slipping, etc.
Issued 27 November 2019
Resolved
Rails or equivalent protection must be installed near the periphery of all decks accessible to crew. Observed supports to wheelhouse top deck bulwark separated from weldments. Repair to satisfaction of attending Marine Inspector. 46CFR144.800 (16c)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 June 2020
Resolution: Found all bulkwark repairs to be satisfactory.
10 - Safety of Navigation › N/A - No Subsystem › Navigation records
Issued 26 November 2019
Resolved
A navigation assessment entry must be recorded in the TVR, official log, or in accordance with the TSMS applicable to the vessel - the entry must include the date and time of the assessment, the name of the individual making the assessment, and the starting and ending points of the voyage that the assessment covers. Navigation assessments did not contain all required items as indicated in the on board logbook. 46CFR140.635(d) (16c)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 July 2020
Resolution: master trained to conduct proper navigation assessment and log in HELM system.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 26 November 2019
Resolved
A towing vessel must be maintained and operated so the watertight integrity and stability of the vessel are not compromised.
Prior to dead-ship tow from New Orleans to Mt. Vernon, AL, vessel must repair the following structural issues & have them inspected / tested by a Marine Inspector:
1) Holed plating found in STBD side shell adjacent to center wing void & PORT side shell adjacent to aft wing void; Crop and renew plating.
2) Cracked/holed weldment in reinforcement plate above starboard propeller shaft; Gouge out wasted portion of existing weld & remake weldment.
3) Found approximately 4' x 2' wasted tranverse bulkhead plating from starboard shell across wing void and aft engine room bulkhead; Crop and renew.
4) Wastage found on top section of transverse bulkhead between bow void & fwd STBD wing void with wasted deck above; Crop & Renew.
5) Found small wasted deck section (pinhole) above stern void, just outboard of starboard corner of superstructure. Carry out repair of affected area.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 11 December 2019
Resolved 22 April 2020
Resolution: Satisfactory repair of steel work; see MISLE narrative.
Construction/Loadline
Issued 26 March 1998
Resolved
THE VESSEL WAS NOT PROPERLY EQUIPT. WITH THE PIPING TO REMOVE OILY WASTE FROM THE BILGES.
Condition: Unknown
Due 3 April 1998
Resolved 3 April 1998
Navigation
Issued 26 March 1998
Resolved
THE 12" BELL REQUIRED BY NAV RULES WAS NOT ON BOARD.
Condition: Unknown
Due 3 April 1998
Resolved 3 April 1998
Fire Fighting
Issued 26 March 1998
Resolved
THE VESSEL WAS REQUIRED TO CARRY 5 B-II EXT., THEY HAD 4 ON BOARD.
Condition: Unknown
Due 3 April 1998
Resolved 3 April 1998
Lifesaving
Issued 26 March 1998
Resolved
THE TYPE I PFDS WERE STOWED WITH THE TYPE V PFDS.
Condition: Unknown
Due 3 April 1998
Resolved 3 April 1998
Navigation
Issued 26 March 1998
Resolved
THE LIGHT LIST WAS NOT ONBOARD.
Condition: Unknown
Due 3 April 1998
Resolved 3 April 1998
Navigation
Issued 26 March 1998
Resolved
THE NAV. RULES BOOK WAS WAS NOT ON BOARD.
Condition: Unknown
Due 3 April 1998
Resolved 3 April 1998
Lifesaving
Issued 26 March 1998
Resolved
THE REQUIRED TEST AND INSP. WERE NOT BEING LOGGED AS REQ.
Condition: Unknown
Due 3 April 1998
Resolved 3 April 1998
Engineering
Issued 26 March 1998
Resolved
THE FUEL TANK VENTS DID NOT HAVE FLAME SCREENS.
Condition: Unknown
Due 3 April 1998
Resolved 3 April 1998