Records from 2002 to 2020. Most recent: inspection, 30 October 2020.
Inspection history · 27
30 October 2020
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7087489
17 August 2018
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6515019
24 July 2018
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6488828
16 November 2017
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6308505
17 March 2016
Administrative Inspection · Annual Inspection · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5835740
27 October 2014
Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5013073
21 August 2014
Administrative Inspection · Damage Survey
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4961895
21 August 2014
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4962701
6 August 2014
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4995337
1 June 2014
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4876390
4 July 2009
Damage Survey · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3523091
4 July 2009
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3533151
15 May 2009
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3488276
16 March 2009
Plan Review "T" Boat
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 3412239
16 March 2009
Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3437124
9 March 2009
Simplified Stability Test
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3440345
6 June 2008
COI Inspection · Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3228140
16 October 2006
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2801426
24 January 2006
Administrative Inspection
Administrative · USCG East District (dp) · USCG East District (CGD-E) · Activity 2572118
25 October 2005
Administrative Inspection
Administrative · USCG East District (dp) · USCG East District (CGD-E) · Activity 2521496
11 October 2005
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2511654
6 October 2005
Examination of Repairs · Damage Survey
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2510249
4 October 2005
Damage Survey
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2508128
17 August 2004
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2168446
9 August 2004
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2167622
11 July 2003
COI Inspection · Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2119795
11 February 2002
Hull Examination · Initial Certification
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1485640
Documentation › Certificates/Documents › Certificate of Inspection
Issued 16 November 2017
Resolved
Vessel may not operate with greater than six passengers until successful completion of a Certificate of Inspection (COI) and a dry-dock inspection. 46 C.F.R. 176.502
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 December 2017
Resolved 23 July 2018
Resolution: Deactivated vessel's COI.
Electrical › Electric Supply System (service) › Battery Installation
Issued 18 March 2016
Resolved
Provide a cover for the battery installation.
Action required: 705 - Other - as specified
Due 1 April 2016
Resolved 9 April 2016
Resolution: Vessel provided photographic evidence of resolution.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 17 March 2016
Resolved
Provide a fire extinguisher service report.
Action required: 705 - Other - as specified
Due 1 April 2016
Resolved 1 April 2016
Resolution: Service provided by Cornerstone Fire Systems.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 17 March 2016
Resolved
Provide a properly operating fire damper closure for machinery space exhaust ventilation.
Action required: 705 - Other - as specified
Due 1 April 2016
Resolved 9 April 2016
Resolution: Vessel prooved proper operation of fire damper.
Documentation › Markings/Placards › Lifejacket Placard
Issued 17 March 2016
Resolved
Provide a PFD donning placard for each type of PFD.
Action required: 705 - Other - as specified
Due 1 April 2016
Resolved 9 April 2016
Resolution: Vessel purchased PFDs to match donning placard.
Engineering › Bilge Water Management System › Not Operational
Issued 17 March 2016
Resolved
Provide a properly operating bilge high level alarm prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 April 2016
Resolved 9 April 2016
Resolution: Vessel provided proof of resolution.
Engineering › Steering Gear System › Ram
Issued 21 August 2014
Resolved
Prove proper operation of outboard motor hydraulic raising/lowering ram system prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 August 2014
Resolution: Vessel replaced motor for lower unit. Tested 04 times. Test Sat.
Engineering › Steering Gear System › Linkage
Issued 4 July 2009
Resolved
NY01- Vessel is to be put out of service until cause can be found in regards to reported steering casuailty while operating with passengers onboard. Vessels is to provide for the following prior to being put back in service:
a) Tech report in regards to cause and correction of said steering loss.
b) Conduct steering test in presence of USCG Marine Inspector.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 July 2009
Resolution: Attended vessel and verified steering system is fully operational.
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 6 June 2008
Resolved
Complete emergency broadcast placard with Call Sign. 46 CFR 184.506
Action required: 705 - Other - as specified
Resolved 30 June 2008
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 6 June 2008
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Resolved 16 March 2009
Resolution: FCC Station License onboard and current.
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 6 June 2008
Resolved
Provide FCC Safety Radio Certificate. 46 CFR 184.502
Action required: 705 - Other - as specified
Resolved 16 March 2009
Resolution: FCC Safety Radio Certifacte onboard and current.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 6 June 2008
Resolved
Mark ring life buoy with vessel’s name. 46 CFR 185.604 (b)
Action required: 705 - Other - as specified
Resolved 30 June 2008
Fire Fighting › Fire Bucket › Quantity
Issued 6 June 2008
Resolved
Provide 2 additional 2.5 gallon fire buckets. 46 CFR 181.610
Action required: 705 - Other - as specified
Resolved 30 June 2008
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 6 June 2008
Resolved
Provide 9 additional adult Type I PFD’s and 1 child Type I PFD IAW 46 CFR 180.71 (a) and (b).
Action required: 705 - Other - as specified
Resolved 30 June 2008
Electrical › Electric Generation Source (service) › Grounding Conductor
Issued 6 June 2008
Resolved
Install conductor for protection against generation of a static charge in fuel fill line IWO flexible hose section. 46 CFR 182.445 (g)
Action required: 705 - Other - as specified
Resolved 6 June 2008
Resolution: Upon closer inspection, it was determined that the fuel fill line was connected to plastic piping. Discrepancy cleared on the spot.
Engineering › Bilge Water Management System › Hose
Issued 6 June 2008
Resolved
Provide additional length of flexible hose for portable bilge pump capable of discharging overboard. 46 CFR 182.520 (b) (2)
Action required: 705 - Other - as specified
Resolved 30 June 2008
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 6 June 2008
Resolved
Replace propeller.
Action required: 705 - Other - as specified
Resolved 30 June 2008
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 25 October 2005
Resolved
Proper documentation of drug testing background checks completed. (49 CFR part 40.25)
Due 25 November 2005
Resolved 23 November 2005
Resolution: Received Documentation
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 11 October 2005
Resolved
Vessels name was marked with letters only one inch high.
Action required: 705 - Other - as specified
Due 14 November 2005
Resolved 7 July 2006
Resolution: Witnessed installation of name on three sides & name/homeport transom.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 11 October 2005
Resolved
Combination bow light was inop. Repair prior to carrying passengers in restricted vis.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 November 2005
Resolved 7 July 2006
Resolution: Witnessed proper operation of bow light.
Engineering › Bilge Water Management System › Pump
Issued 11 October 2005
Resolved
Provide UL approved pump with functional visual indicator & op test.
Action required: 705 - Other - as specified
Due 14 November 2005
Resolved 7 July 2006
Resolution: Witnessed instalation & operation of pump & indicator light.
Communications › Alarms/Indicators › Bilge Alarm
Issued 11 October 2005
Resolved
Bilge alarm mounted at same level as bilge pump & bilge pump float switch.
Action required: 705 - Other - as specified
Due 14 November 2005
Resolved 7 July 2006
Resolution: Witnessed installation of alarm in proper location.
Communications › Alarms/Indicators › Propeller Direction Indicator
Issued 11 October 2005
Resolved
Drive lock light inop.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 November 2005
Resolved 7 July 2006
Resolution: Witnessed operation of drive lock light.
Documentation › Markings/Placards › Oil Discharge Placard
Issued 11 October 2005
Resolved
No oil discharge placard onboard.
Action required: 705 - Other - as specified
Due 14 November 2005
Resolved 13 July 2006
Resolution: Witnessed placard.
Electrical › Electrical Distribution System (service) › Switch
Issued 11 October 2005
Resolved
Battery disconnect switch broken.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 November 2005
Resolved 7 July 2006
Resolution: Witnessed proper operation of battery disconnect switch.
Operations/Management › Drills/Instruction › Not Conducted
Issued 11 October 2005
Resolved
Underway inspection not conducted due to transmission casualty. Conduct u/w trials to verify pilot house control, steering, & shaft seal.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 November 2005
Resolved 7 July 2006
Resolution: Tested sat.
Engineering › Reduction Gearing/Clutches › Line Shaft
Issued 11 October 2005
Resolved
Front axle drive shaft missing. Hull penetration blanked off.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 November 2005
Resolved 7 July 2006
Resolution: Witnessed completed approved repairs.
Construction/Loadline › Hull › Hull Plating
Issued 11 October 2005
Resolved
Brass drain plug tapped into hull plating. Submit repair proposal.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 November 2005
Resolved 7 July 2006
Resolution: Witnessed completed approved repairs.
Engineering › Fuel Oil Service System › Piping
Issued 11 October 2005
Resolved
No bonding in fuel filler piping.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 November 2005
Resolved 7 July 2006
Resolution: Witnessed installation of bonding wire.
Fire Fighting › Fixed Gas Fire Extinguishing System › Tanks
Issued 11 October 2005
Resolved
Fixed fire system not onboard.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 November 2005
Resolved 7 July 2006
Resolution: Witnessed installation of preengineered system.
Engineering › Reduction Gearing/Clutches › Gear
Issued 6 October 2005
Resolved
Repair transmission.
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 November 2005
Resolved 7 July 2006
Resolution: Witnessed installation of new transmission.
Construction/Loadline › Hull › Bracket
Issued 4 October 2005
Resolved
Port rear bumper, outboard bracket, weld broke away from hull.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 November 2005
Resolved 9 November 2005
Resolution: Doubler plates added and bumper brackets re-welded.
Construction/Loadline › Structures › Door
Issued 15 July 2004
Resolved
Provide method of securing watertight door open for man overboard.
Due 15 August 2004
Resolved 13 August 2004
Resolution: Provided method.
Documentation › Certificates/Documents › FCC SSL
Issued 15 July 2004
Resolved
Provide FCC certificate.
Due 15 August 2004
Resolved 13 August 2004
Resolution: Provided certificate.
Accommodation/Occupational Safety › Other Accommodation Spaces › Recreation Space
Issued 15 July 2004
Resolved
Label deck hand seat, crew only.
Due 15 August 2004
Resolved 13 August 2004
Resolution: Labeled seat.
Engineering › Bilge Water Management System › Manifold
Issued 15 July 2004
Resolved
Properly lable bilge alarm and control panel.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 July 2004
Resolution: Labeled bilge and control panel.
Fire Fighting › Fire Bucket › Availability
Issued 15 July 2004
Resolved
Provide 3 fire buckets.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 July 2004
Resolution: Provided buckets.
Operations/Management › Vessel Safety Management
Issued 11 February 2002
Resolved
Clear all 22 issued work list items on case #1485640 prior to allowing passengers for hire. LEGACY COMPONENT DESC: Maintenance of Ship/Equipment
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 August 2002
Resolved 28 May 2004
Resolution: Vessel not in service.