Records from 2001 to 2020. Most recent: inspection, 7 November 2020.
Inspection history · 19
7 November 2020
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7091236
24 February 2020
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6914889
7 December 2017
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6320519
27 October 2014
Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5013069
6 August 2014
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4851295
15 May 2009
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3488276
16 March 2009
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3437062
8 August 2008
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3303825
15 October 2007
Internal Structural Exam · Hull Examination · COI Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3081103
21 June 2006
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2687338
16 June 2006
Damage Survey · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2681904
16 June 2006
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2685129
16 November 2005
Examination of Repairs · Damage Survey
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2536082
6 October 2005
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2564732
8 August 2005
Examination of Repairs
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2502491
21 July 2005
Simplified Stability Test · COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2431994
3 October 2002
Administrative Inspection
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1683880
13 September 2001
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1461438
25 July 2001
Initial Construction-Excluding Oversight · Initial Certification
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1362373
Fire Fighting › Remote Fuel Shutoff › General
Issued 15 October 2007
Resolved
Provide sign for Fuel oil shut-off valve aft.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 November 2007
Fire Fighting › Remote Fuel Shutoff › General
Issued 15 October 2007
Resolved
Provide sign for Fuel oil shut-off valve in engine space.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 November 2007
Construction/Loadline › Structures › Door
Issued 15 October 2007
Resolved
Replace all gaskets on watertight hatches.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 November 2007
Fire Fighting › Ventilation Systems › Operating Controls
Issued 15 October 2007
Resolved
Properly install fire damper remote pulls forward port/STBD.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 November 2007
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 15 October 2007
Resolved
Properly lag MDE exhaust manifold and turbo charger.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 November 2007
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 15 October 2007
Resolved
Properly stow all PFDs for easy / quick removal.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 November 2007
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 15 October 2007
Resolved
Prove proper operation of fixed firefighting override.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 November 2007
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 15 October 2007
Resolved
Post emergency procedures.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 November 2007
Communications › Public Address System › Announcing Station
Issued 15 October 2007
Resolved
Prove proper operation of vessel's PA system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 November 2007
Construction/Loadline › Structures › Deck Plating
Issued 15 October 2007
Resolved
Make permanent repairs to ladder mounts port side.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 November 2007
Construction/Loadline › Structures › End Bulkhead
Issued 15 October 2007
Resolved
Make permanent repairs to muffler shield.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 November 2007
Electrical › Lighting (service) › Lighting Fixture
Issued 15 October 2007
Resolved
Remove water and repair turn signal lights.
Action required: 705 - Other - as specified
Due 7 January 2008
Resolved 8 August 2008
Resolution: Turn signals lights were repaired.
Construction/Loadline › Hull › Bracket
Issued 16 November 2005
Resolved
Cracked weld on port outboard rear bumper bracket.
Action required: 705 - Other - as specified
Due 1 December 2005
Resolved 27 March 2006
Resolution: Inspected repairs, all sat.
Construction/Loadline
Issued 13 September 2001
Resolved
Provide access for axle vent hull closure valve.
Condition: Unknown
Due 13 November 2001
Resolved 3 October 2002
Resolution: Vessel''s COI was deactivated on 10/03/02. Cleared all deficiencies in MISLE files for administrative purposes. See activity #1683880 narrative for cleared deficiencies prior to reactivating COI.
Engineering
Issued 13 September 2001
Resolved
Properly bond fuel fill per 46 CFR 182.445(g).
Condition: Unknown
Due 13 November 2001
Resolved 3 October 2002
Resolution: cleared for administrative reasons
Fire Fighting
Issued 13 September 2001
Resolved
Properly seal dampers and prove proper operation forward and aft.
Condition: Unknown
Due 13 November 2001
Resolved 3 October 2002
Resolution: Vessel''s COI was deactivated on 10/03/02. Cleared all deficiencies in MISLE files for administrative purposes. See activity #1683880 narrative for cleared deficiencies prior to reactivating COI.
Construction/Loadline
Issued 13 September 2001
Resolved
Provide proper sealing device which is acceptable to the OCMI in lieu of current RTV sealant which is on the thru hull wire stuffing tube.
Condition: Unknown
Due 13 November 2001
Resolved 3 October 2002
Resolution: Vessel''s COI was deactivated on 10/03/02. Cleared all deficiencies in MISLE files for administrative purposes. See activity #1683880 narrative for cleared deficiencies prior to reactivating COI.
Documentation
Issued 25 July 2001
Resolved
Complete a new to zone inspection upon arrival, or within a time specified by the cognizant OCMI (MSO St. Louis, MO)
Condition: Unknown
Due 25 July 2001
Resolved 25 July 2001
Documentation
Issued 25 July 2001
Resolved
Complete MSO Savannah's worklist to the satisfaction of the cognizant OCMI.
Condition: Unknown
Due 25 July 2001
Resolved 25 July 2001