Records from 2011 to 2026. Most recent: inspection, 18 March 2026.
Inspection history · 12
18 March 2026
Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8328210
23 April 2025
Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8118065
16 August 2024
COI Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7977434
25 January 2024
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7864883
28 September 2023
Administrative Inspection · Drydock Extension
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7800245
27 March 2023
TPO Audit
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7674695
18 March 2022
COI Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7422232
28 September 2021
Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7321375
7 October 2020
Annual Inspection · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7024970
19 April 2019
Administrative Inspection · Initial Certification · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6666337
5 April 2012
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4282392
28 April 2011
Deficiency Check · Industry Initiated Exam
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3994685
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 October 2020
Resolved
A sufficient amount of lined commercial fire hose 15 meters (50 feet) in length, at least 40 mm (1.5 inches) in diameter and immediately available to attach. Hose attached to portable fire pump was greater then 50 FT. Vessel rep corrected deficiency on the spot to the satisfaction of the attending Coast Guard marine inspector.
Action required: 10 - Deficiency Rectified
Resolved 7 October 2020
Resolution: Corrected prior to conclusion of inspection – 50FT hose installed to the satisfaction of the attending CG marine inspector.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 7 October 2020
Resolved
A vessel must be operated in accordance with applicable laws and regulations and in such a manner as to afford protection against hazards to life, property, and the environment. Inspection found steering system flanking rudder hose(s) showing excessive weathering with one hose having bulge. Replace hoses and prove proper operations of steering system to the satisfaction of the attending Coast Guard marine inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 November 2020
Resolved 3 November 2020
Resolution: Cleared to the satisfaction of the Coast Guard marine inspector
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 7 October 2020
Resolved
Each towing vessel must be equipped with an industrial type first aid cabinet or kit, appropriate to the size of the crew and operating conditions. Inspection found expired items. Prove all items within the first aid kit are not expired to the satisfaction of the Coast Guard Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 October 2020
Resolved 20 October 2020
Resolution: Cleared to the satisfaction of the Coast Guard marine inspector
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 7 October 2020
Resolved
On vessels of less than 20 meters in length, the sidelights, if necessary to meet the requirements of §84.15, shall be fitted with matt black inboard screens. Both PORT and Starboard inboard screens paint is flaking. Prove to the satisfaction of the attending Coast Guard marine inspection that both screens are painted matt black.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 November 2020
Resolved 3 November 2020
Resolution: Cleared to the satisfaction of the Coast Guard marine inspector
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 12 August 2019
Resolved
Fire detection panel is a constant state of alarm. Troubleshoot and repair fire detection system as necessary.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 September 2019
Resolution: Tested fire detection panel in both zones.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 12 August 2019
Resolved
Ensure safety orientation covers all items in stated site.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 September 2019
Resolved 27 August 2019
Resolution: Met with [name withheld] who demonstrated compliance.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 12 August 2019
Resolved
Ensure employee's name is clearly indicated on safety orientation.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 September 2019
Resolved 27 August 2019
Resolution: Met with [name withheld] who demonstrated compliance.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 12 August 2019
Resolved
Ensure orientation for individuals that are not crewmembers meets requirements in stated site.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 September 2019
Resolved 27 August 2019
Resolution: Met with [name withheld] who demonstrated compliance.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 12 August 2019
Resolved
Prove that means are available to document all annual training required by stated site.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 September 2019
Resolved 27 August 2019
Resolution: Met with [name withheld] who demonstrated compliance.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 12 August 2019
Resolved
Provide procedures to address fall overboard prevention.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 September 2019
Resolved 27 August 2019
Resolution: Met with [name withheld] who demonstrated compliance.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 12 August 2019
Resolved
Provide means to document required navigation safety training.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 September 2019
Resolved 27 August 2019
Resolution: Met with [name withheld] who demonstrated compliance.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 12 August 2019
Resolved
Provide means to document safety orientation required when crewmembers have not received training required by stated site.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 September 2019
Resolved 27 August 2019
Resolution: Met with [name withheld] who demonstrated compliance.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 12 August 2019
Resolved
Provide means to record all required items in Towing Vessel Record.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 September 2019
Resolved 27 August 2019
Resolution: Met with [name withheld] who demonstrated compliance.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 12 August 2019
Resolved
Provide means to record required tests.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 September 2019
Resolved 3 September 2019
Resolution: Received sufficient documentation via email.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 12 August 2019
Resolved
Prove Chemical Testing program meets requirements of stated site.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 September 2019
Resolved 27 August 2019
Resolution: Met with [name withheld] who demonstrated compliance.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 12 August 2019
Resolved
Provide means to document required maintenance and testing of life saving equipment.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 September 2019
Resolved 27 August 2019
Resolution: Met with [name withheld] who demonstrated compliance.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 August 2019
Resolved
Ensure that semi-portable fire extinguisher (B-V) is mounted in location allowing full coverage of engine room.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 September 2019
Resolution: Extinguisher moved to location just above port side engine room door.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 12 August 2019
Resolved
Ensure generator exhaust is insulated or otherwise guarded to protect against burns.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 September 2019
Resolved 3 September 2019
Resolution: Exhaust lagged.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 12 August 2019
Resolved
Employees utilize approved type PFDs, but not approved type work vests under 46 CFR 160.053. If company wishes to utilize Type II/III approved vests they must submit a request for Special Consideration to do so.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 September 2019
Resolved 27 August 2019
Resolution: Company no longer utilizes type III PFDs and have purchased work vests that comply.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 12 August 2019
Resolved
Provide documented recordkeeping for towing gear to include type, size, and service of each towline, face wire and spring line used to make the towing vessel fast to her tow. Date of examination, each item of towing gear examined, and person(s) conducting examination.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 September 2019
Resolved 3 September 2019
Resolution: Received sufficient documentation via email.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 19 April 2019
Resolved
Demonstrate the testing of engine alarm set points for generator low lube oil pressure and high cooling water temp.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 September 2019
Resolved 26 September 2019
Resolution: Witnessed satisfactory testing.