MAURY USCG vessel records
← All vessels

CHARLIE WHITE

Built
1977
Last inspected
27 September 2021
Documentation
Expired · NVDC file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 27 September 2021
…with no type recorded11
Operational controls None recorded without a removal date
Years with a record 13 calendar years (2000–2021)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDD2979
154927
Flag
UNITED STATES
Maury page id
psix-154927

Documentation record

Registered dimensions (L × B × D)47.5 ft × 18.0 ft × 6.7 ft
Registered tonnagegross 55 / net 38
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTUCKER MARINE INC · CINCINNATI, OH, UNITED STATES · built 1977
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portST LOUIS, MO
Endorsements, as the file codes themcw_un
DocumentationExpired · issued 30 June 2004
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it55 - Regulatory (Subpart C or D), Gross Ton
38 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 23 inspections, each with its date, unit and type; 6 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 12 other vessels inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 12

Inspection history · 23

27 September 2021 Administrative Inspection
Administrative · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 7322283
21 August 2016 Type not recorded
No type recorded · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 5995486
21 November 2014 Type not recorded
No type recorded · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 5027424
25 April 2014 Industry Initiated Exam · MTSA Verification · Deficiency Check
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 4846531
1 November 2011 Type not recorded
No type recorded · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 4204284
7 September 2010 Type not recorded
No type recorded · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 3853413
7 September 2010 Damage Survey
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 3906964
7 July 2010 Type not recorded
No type recorded · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 3793484
6 November 2009 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3628743
22 October 2009 MTSA Verification · Deficiency Check · Industry Initiated Exam · MARPOL
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 3619671
23 February 2009 Type not recorded
No type recorded · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 3423071
28 July 2008 Type not recorded
No type recorded · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 3282262
14 July 2008 Type not recorded
No type recorded · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 3267803
14 July 2008 Examination of Repairs · Damage Survey · Deficiency Check · Uninspected Other
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 3270738
25 December 2007 Type not recorded
No type recorded · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 3120825
1 February 2007 Deficiency Check · Uninspected Other
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 2869761
10 August 2006 Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2742870
10 August 2006 Security Plan Amendment Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2742917
26 July 2006 Uninspected Other · MTSA Verification
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 2726895
6 January 2005 Type not recorded
No type recorded · MSD PEORIA · USCG Heartland District (CGD-H) · Activity 2362546
3 November 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1979302
13 March 2002 Annual Inspection
Physical examination · MSD PEORIA · USCG Heartland District (CGD-H) · Activity 1495870
25 October 2000 Type not recorded
No type recorded · MSD PEORIA · USCG Heartland District (CGD-H) · Activity 283525

Deficiency record · 6

Construction/Loadline › Penetrations › Pipe Flange
Issued 14 July 2008 Resolved
Make the forward engineroom bulkhead, wire penetrations, watertight.
Condition: Placed in Improper Service
Due 14 September 2008
Resolved 9 September 2008
Electrical › Electrical Distribution System (service) › Cable
Issued 14 July 2008 Resolved
Properly secure the overhead, electrical wires in the fuel tank void.
Condition: Placed in Improper Service
Due 15 September 2008
Resolved 9 September 2008
Fire Fighting › Combustible Materials › Insulation
Issued 14 July 2008 Resolved
Reroute the steering system hydraulic hoses so they are not immediately adjacent to the exhaust muffler.
Condition: Improper Installation
Due 15 September 2008
Resolved 9 September 2008
Electrical › Electrical Distribution System (service) › Wiring
Issued 1 February 2007 Resolved
Properly secure the wires in the overhead of the sewage hold with metal hangers.
Condition: Unknown
Due 1 March 2007
Resolved 30 March 2007
Engineering › Diesel Engine (auxiliary) › Bearing
Issued 1 February 2007 Resolved
Determine source of oil leak and clean the residual oil from the stbd generator.
Condition: Unknown
Due 1 March 2007
Resolved 30 March 2007
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 1 February 2007 Resolved
Properly insulate the generator dry exhaust pipe.
Condition: Improper/Lack of Maintenance
Due 1 March 2007
Resolved 30 March 2007

Ownership record