MAURY USCG vessel records Sign in
← All vessels

JOSHUA P

JOSHUA P is a 1977 industrial vessel. The Coast Guard has recorded 45 inspections since 1989, most recently in October 2015, along with 25 deficiencies and 5 casualty investigations between 2013 and 2014.

Records from 1989 to 2015. Most recent: inspection, 21 October 2015.

Built
1977
Last inspected
21 October 2015
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDD3368
155209
Flag
UNITED STATES
338524000, 367130240 (licence lapsed)
Maury page id
psix-155209

Inspections, by type

…with no type recorded17
Years with a record 20 calendar years (1989–2015)
The 45 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 11 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 1979.

Documentation record

Registered dimensions (L × B × D)182.4 ft × 76.0 ft × 11.3 ft
Registered tonnagegross 1,499 / net 1,499
ITC dimensions (L × B × D)182.4 ft × 76.0 ft × 11.3 ft
ITC tonnagegross 1,670 / net 501
BuilderGEOSOURCE INC · HARVEY, LA, UNITED STATES · built 1977
Hull materialSteel
PropulsionNot recorded
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portBATON ROUGE, LA
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itIndustrial Vessel
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1499 - Regulatory (Subpart C or D), Net Ton
501 - Convention (Subpart B), Net Ton
1499 - Regulatory (Subpart C or D), Gross Ton
1670 - Convention (Subpart B), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDD3368MMSI 367130240 · expired · compulsorily equipped · granted 6 May 2016, cancelled 22 August 2026
WCZ3366MMSI 338524000 · expired · compulsorily equipped · granted 15 June 1999, cancelled 15 August 2009 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

MAJOR Towing Vessel · MISLE 196573 · 29 June 2003 · activity 1840497LARRY J HEBERT Towing Vessel · MISLE 200192 · 29 June 2003 · activity 1840497

Inspection history · 45

21 October 2015 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5747680
16 August 2011 Examination of Repairs · Administrative Inspection · COI Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4117554
20 October 2010 Deficiency Check · MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3838058
2 February 2009 Administrative Inspection · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3403922
10 November 2008 Periodic Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3356344
13 March 2008 Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3163926
11 December 2007 Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3113461
7 November 2007 MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3093228
6 September 2007 Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3051806
6 July 2006 Deficiency Check · COI Inspection · Examination of Repairs · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2703549
2 June 2006 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2678864
24 January 2006 Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2572305
6 January 2005 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2269862
10 September 2004 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2192633
25 July 2003 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1856602
29 June 2003 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1840497
8 August 2002 Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1658235
8 July 2002 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1640291
25 October 2001 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1076324
8 August 2001 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1439255
24 July 2000 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1401332
6 February 2000 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 770958
1 February 2000 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 189253
16 November 1999 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 767036
9 November 1999 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 195988
11 August 1999 Initial Certification · Hull Examination · Deadweight Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1415276
9 April 1999 Deadweight Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1469255
15 December 1998 Construction Oversight
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1461105
7 July 1998 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1409876
14 May 1996 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1082163
9 May 1995 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 889633
1 May 1995 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1179967
12 December 1994 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1389932
18 May 1993 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1151781
7 April 1993 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 838390
26 March 1993 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 665458
8 February 1993 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1410771
4 February 1993 Damage Survey
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1393889
1 February 1993 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 231372
31 January 1993 Damage Survey
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1154836
30 January 1993 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 165265
2 November 1989 Administrative
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1000649
29 October 1989 Permit to Proceed
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1312281
25 July 1989 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 889446
24 January 1989 Uninspected Other
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1210714

Deficiency record · 25

Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 20 October 2010 Resolved
Feed water cooling line to SSDG found to have small leak located in welding room.
Action required: 705 - Other - as specified
Due 20 November 2010
Resolved 29 October 2010
Resolution: C/R piping in SW cooling line. //s// [name withheld]
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 20 October 2010 Resolved
The cooling line to the SSDG had doublers installed on the piping in the welding machine room.
Action required: 705 - Other - as specified
Due 20 November 2010
Resolved 29 October 2010
Resolution: C/R piping to remove doublers. //s// [name withheld]
Electrical › Electrical Distribution System (service) › Switchboard
Issued 20 October 2010 Resolved
The panel enclosing the back of the main switchboard is not secured.
Action required: 705 - Other - as specified
Due 20 November 2010
Resolved 29 October 2010
Resolution: The panel has been properly secured to the back of the main switchboard. //s// [name withheld]
Fire Fighting › Fire Main › Valves
Issued 20 October 2010 Resolved
The check valves nearest both fire pumps are not operational.
Action required: 705 - Other - as specified
Due 20 November 2010
Resolved 29 October 2010
Resolution: The check valves have been replaced and are now operational. //s// [name withheld]
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 20 October 2010 Resolved
MDS overboard discharge piping in laundry room is leaking.
Action required: 705 - Other - as specified
Due 20 November 2010
Resolved 29 October 2010
Resolution: C/R MSD overboard discharge piping to repair leaking portion. //s// [name withheld]
Accommodation/Occupational Safety › Sleeping Accommodations › Locker
Issued 20 October 2010 Resolved
Lockers and spaces containing SCBAs are not marked per 46CFR92.37-20.
Action required: 705 - Other - as specified
Due 20 November 2010
Resolved 29 October 2010
Resolution: Spaces and lockers containing SCBAs are now properly marked. //s// [name withheld]
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 20 October 2010 Resolved
Whistles contain cork balls, which can swell when wet rendering the whistle in operable.
Action required: 705 - Other - as specified
Due 20 November 2010
Resolved 29 October 2010
Resolution: All whistles with cork balls have been replaced with SOLAS approved whistles. //s// [name withheld]
Engineering › Fuel Oil Service System › Hose
Issued 20 October 2010 Resolved
Several flexible hoses on the #1, #2 and #3 SSDG were longer than 30 inches.
Action required: 705 - Other - as specified
Due 20 November 2010
Resolved 29 October 2010
Resolution: Modifications made to fuel lines ensuring that no sections of flex hoses were greater than 30 inches in length. //s// [name withheld]
Electrical › Electrical Distribution System (emergency) › Distribution Panel Bus
Issued 20 October 2010 Resolved
The circuit breakers on the second distribution panel (DP-2) for the Emergency Generator were not labeled.
Action required: 705 - Other - as specified
Due 20 November 2010
Resolved 29 October 2010
Resolution: The breakers on the second distribution panel (DP-2) for the Emergency Generator are now labeled. //s// [name withheld]
Fire Fighting › Structural - A Class Divisions › Doors
Issued 7 November 2007 Resolved
Door to messdeck (A-class) has been cut and a piece of plexi-glass has been installed.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 May 2008
Resolved 29 February 2008
Resolution: Door has been replaced with a proper A-class door (with factory installed glass).
Fire Fighting › Structural - A Class Divisions › Doors
Issued 7 November 2007 Resolved
Door from galley to ship's office (A-class) has been cut in two and turned into a dutch door.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 May 2008
Resolved 29 February 2008
Resolution: Door replaced with A-class door.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 7 November 2007 Resolved
Piping on the MSD system currently has temporary repairs (splash zone epoxy). The piping connecting the top tank to the lower tank is covered in splash zone; unable to discern extent of pinholes/fractures.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 February 2008
Resolved 29 February 2008
Resolution: Replaced corroded piping.
Fire Fighting › Structural - A Class Divisions › Door Frames
Issued 7 November 2007 Resolved
Self Closing device on the galley to messdeck door (A-class) is missing. Also, the door latch is missing, therefore the door does not maintain closure.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 May 2008
Resolved 29 February 2008
Resolution: Door to galley is now self closing.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 7 November 2007 Resolved
All A-class doors in the main deck to 2nd deck latterwell currently are missing closure latches.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 11 February 2008
Resolved 29 February 2008
Resolution: Latches replaced.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 7 November 2007 Resolved
Fire and Safety Plan must be submitted to the cognizant OCMI to reflect correct position and number of life ring buoys w/light and correct number and position of Fireman's outfits.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 May 2008
Resolved 11 December 2007
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 6 September 2007 Resolved
Make corrections to fire control plan as outlined. Resubmit for approval.
Due 6 October 2007
Resolved 16 October 2007
Fire Fighting › Structural - Main Vertical Zones › General
Issued 18 August 2006 Resolved
Replace roll-down fire proof door @ galley buffet
Due 1 September 2006
Resolved 4 October 2006
Resolution: Received service report from River Parish [name withheld] stating fire shutter was repaired and satisfactorily tested.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 18 August 2006 Resolved
Draft fire plan submitted and awaiting CG approval. Provide 8 copies of original plan for CG approval stamp.
Due 18 September 2006
Resolved 28 August 2006
Electrical › Electric Generation Source (service) › Generator
Issued 25 July 2003 Resolved
Generator prime mover had fuel leak at fuel pump.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 July 2003
Resolution: Mechanic immediately replaced pump with spare from vessel stock.
Fire Fighting › Fixed Fire Detection System › Heat Detectors
Issued 30 July 2002 Resolved
Heat detector mounted on a open junction box.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 July 2002
Resolution: Installed correctly in junction box.
Stability › Watertight Integrity
Issued 30 July 2002 Resolved
Several W.T. doors throughout machinery spaces needed proper adjustments. LEGACY COMPONENT DESC: Watertight Doors
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 July 2002
Resolution: Adjusted doors.
Accommodation/Occupational Safety › Occupational Safety
Issued 30 July 2002 Resolved
Issued 835 to have the dive equipment examined as per 46 CFR part 197. LEGACY COMPONENT DESC: Dive Equipment
Due 31 August 2002
Resolved 8 August 2002
Resolution: Sighted paperwork and certificates to ensure equipment was examined IAW 46 CFR part 197,
Lifesaving
Issued 8 August 2001 Resolved
REPLACE EXHAUST LAGGING ON JET PUMP ENGINES.
Condition: Unknown
Due 8 September 2001
Resolved 11 September 2001
Construction/Loadline
Issued 8 August 2001 Resolved
REPLACE 2 EA SINGLE BOLT ESCAPE HATCHES WITHQUICK ACTING TYPES.
Condition: Unknown
Due 8 August 2001
Resolved 8 August 2001
Navigation
Issued 8 August 2001 Resolved
DEMOSTRATE PROPER OPERATION OF NAV LIGHT PANEL.
Condition: Unknown
Due 8 September 2001
Resolved 11 September 2001

Casualty record · 5

6 March 2013Routine · role: Involved in a Marine Casualty · 1 injured · activity 4555850
27 July 2013Routine · role: Acknowledged Pollution Source · activity 4669206
25 September 2013Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4724074
20 November 2013Routine · role: Involved in a Marine Casualty · activity 4759484
18 February 2014Routine · role: Acknowledged Pollution Source · activity 4801888
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

MIGHTY CHIEF (2013–2014). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.