Records from 2011 to 2026. Most recent: inspection, 8 January 2026.
Documentation record
Registered dimensions (L × B × D)52.0 ft × 19.6 ft × 6.2 ft
Registered tonnagegross 52 / net 35
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSTEEL BOAT BUILDERS · PIERRE PART, LA, UNITED STATES · built 1978
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portHOUMA, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 6 May 2026 · expires 30 June 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it52 - Regulatory (Subpart C or D), Gross Ton
35 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 19
8 January 2026
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8290234
3 June 2025
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8152649
6 February 2025
COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8075629
8 November 2024
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8032435
8 November 2024
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8033561
16 April 2024
Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7896225
17 March 2023
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7696229
6 February 2023
Internal Structural Exam · Deficiency Check · Annual Inspection · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7632570
12 September 2022
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7557082
11 May 2022
Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7448412
7 April 2022
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7426479
17 February 2022
Load Line/Change of Employment · Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7398347
16 February 2022
Administrative Inspection
Administrative · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7397669
20 August 2021
Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7292399
6 April 2021
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7169296
13 January 2020
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6888261
3 December 2016
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6066520
26 June 2012
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 4358548
13 June 2011
Industry Initiated Exam · DAPI Audit
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4044276
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 8 January 2026
Resolved
The design of the fire detection system and its installation on the towing vessel is certified and inspected by a registered professional engineer.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 January 2026
Resolved 13 January 2026
Resolution: Received copy of PE letter for the fire panel.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 6 February 2025
Resolved
A towing vessel may not be operated without having onboard a valid COI issued by the Coast Guard as required by § 136.202.
Vessel COI has expired on 14JAN2025. Vessel permitted one time transit to Texas Marine Shipyard. Following completion of transit a COI inspection is required to be completed prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 February 2025
Resolution: Satisfactory COI Renewal conducted.
02 - Structural Conditions › N/A - No Subsystem › Cargo tank vent system
Issued 6 February 2025
Resolved
Each integral fuel tank must have a vent that connects to the highest point of the tank, discharges on a weather deck through a bend of 180 degrees, and is fitted with a 30-by-30-mesh corrosion-resistant flame screen.
MI observed stbd gooseneck wasted at bend using non-approved methods to prevent flames from entering fuel tank. Vessel shall enact repairs to gooseneck and install 30x30 mesh flame screens.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 March 2025
Resolved 10 March 2025
Resolution: Vessel submitted satisfactory evidence of repair.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 November 2024
Resolved
Machinery and electrical systems must be designed and maintained to provide safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions.
Sector Houston/Galveston received a report of a loss of propulsion and electrical power while underway IVO Houston Yatch Club. Vessel must provide written Third Party Report to the satisfaction of Coast Guard Marine Inspector.
46CFR143.205(a)
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 8 November 2024
Resolution: TECH conducted maintenance and resolved the issue. MIs attended and conducted visual inspection of port engine as well as conducting sea trials. VSL port engine now in good working order.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 6 April 2021
Resolved
Closure devices must be provided for deckhouse or hull penetrations, which open to the exterior of the vessel and which may allow water to enter the vessel. Both port and stbd door gaskets were wasted. Replace gaskets and test closure.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 May 2021
Resolved 7 April 2021
Resolution: New gaskets were installed on both watertight doors protecting the engine room.
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 6 April 2021
Resolved
Emergency lighting must be provided for all internal crew working and living areas. Emergency lighting sources must provide for sufficient illumination under emergency conditions to facilitate egress from each space. The Non-electric, phosphorescent adhesive lighting strips were removed for painting. Re-install strips or lights.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 6 April 2021
Resolved 7 April 2021
Resolution: Owner purchased a new emergency lighting for the galley area.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 6 April 2021
Resolved
Has installed, in the engine room and any other area where background noise makes a general alarm hard to hear, a supplemental flashing red light. The general alarm speaker is required to be in addition to the light. The speaker was inop, repair and test.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 6 April 2021
Resolved 7 April 2021
Resolution: Received a tech report stating the sound part of the alarm was repaired. Issue was identified to be a loose connection.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 6 April 2021
Resolved
Electrical equipment must be protected from wet environments. The stbd engine room light did not have a cover. Install protective cover that is appropriate the the light.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 6 April 2021
Resolved 7 April 2021
Resolution: A new protective cover was installed on the light fixture on the starboard engine room light.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 April 2021
Resolved
Gauge required for the hydraulic steering fluid pressure. The gauge was inop. Replace with functioning gauge.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 May 2021
Resolved 7 April 2021
Resolution: A new gauge was installed on vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 April 2021
Resolved
Each towing vessel must carry at least one appropriately-sized life-jacket for each person. 01 Type I life jacket needs to be replaced, as it was melted.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 6 April 2021
Resolved 7 April 2021
Resolution: A new Type I life jacket was placed onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 April 2021
Resolved
Each lifebuoy on a towing vessel must be approved under series 160.050 or 160.150, and must be marked in block capital letters with the name of the vessel. The lifebuoys need to have the name marked and 01 needs new reflecting tape of appropriate type.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 May 2021
Resolved 7 April 2021
Resolution: Name of the vessel and new retro-reflective tape was placed on the life buoys.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 6 April 2021
Resolved
Every towing vessel of 26 feet or over in length while navigating is required to have a radiotelephone that is capable of transmitting and receiving communications in applicable channels, in accordance with the Bridge-to-Bridge Act. A Bridge-to-Bridge certificate attesting to such functionality of the vessel's radios is required.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 May 2021
Resolved 19 May 2021
Resolution: MSU Houma received a copy of the Bridge-to-Bridge certificate, issued on 13MAY2021, and valid until 13MAY2022. Copy attached to deficiency documents.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 6 April 2021
Resolved
The result of the inspections required by 33 CFR 164.76 must be documented. Vessel needs to document/record the completion and results of the towing gear inspections.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 May 2021
Resolved 19 May 2021
Resolution: MSU Houma received photos of records of towing gear inspection. Photos attached to deficiency documents.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 6 April 2021
Resolved
Each towing vessel must be maintained and operated so as to minimize fire hazards. Portable space heaters should not be used/placed on the vessel.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 6 April 2021
Resolved 6 April 2021
Resolution: Space heaters were removed from the vessel.