Inspection history · 27
23 May 2026
PSC A · COC-CVE Annual
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8372524
30 January 2026
Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8303914
28 December 2025
Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8287757
25 December 2025
ISM Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8287241
28 November 2025
COC-CVE Quarterly · PSC B
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8274728
17 November 2025
Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8269854
10 November 2025
Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8266946
10 October 2025
Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8250372
25 September 2025
Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8241171
11 September 2025
Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8231635
28 August 2025
Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8219717
31 July 2025
Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8199358
28 July 2025
Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8196431
20 July 2025
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8191950
17 July 2025
Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8188081
14 July 2025
Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8185627
4 July 2025
Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8175028
19 June 2025
Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8162708
16 June 2025
Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8160052
5 June 2025
Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8153106
31 May 2025
Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8153093
30 May 2025
PSC A · COC-CVE Annual
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8139671
6 February 2025
MARPOL Annex I Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8077163
3 December 2024
COC-CVE Quarterly · PSC B
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8040788
5 June 2024
PSC A · COC-CVE Annual
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7923260
25 February 2024
COC-CVE Initial · COC-CVE Initial Prep
Administrative · Activities Europe · Activity 7893423
6 December 2016
MARPOL Annex I Examination · ISPS II Exam · STCW 95 Exam · Ballast Water Examination · MARPOL Annex V Examination · ILO-147 Exam · COC-CVE Annual
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6051855
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 May 2026
Resolved
The condition of the ship and its equipment shall be maintained to conform to with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or person on board. Oxygen and nitrogen bottles on the aft mooring deck were not properly stored off the deck.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 May 2026
Resolved 23 May 2026
Resolution: Moved oxygen on a pallet.
11 - Life Saving Appliances › N/A - No Subsystem › Embarkation arrangement survival craft
Issued 23 May 2026
Resolved
Muster and embarkation stations shall be adequately illuminated by lighting supplied from the emergency source of electrical power required by regulation II- I/42 or II-1/43. PSCO observed non-operational emergency lighting forward of lifeboat #16 and #18.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 May 2026
Resolved 23 May 2026
Resolution: Vessel replaced lights.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 23 May 2026
Resolved
All doors shall be capable of remote and automatic release from a continuously manned central control station, either simultaneously or in groups, and also individually from a position at both sides of the door. Indication must be provided at the fire control panel in the continuously manned central control station whether each of the remote-controlled doors are closed. The release mechanism shall be so designed that the door will automatically close in the event of disruption of the control system or central power supply. Release switches shall have an on off function to prevent automatic resetting of the system. Hold-back hooks not subject to central control station release are prohibited. PSCO observed galley fire door 3.14 on deck 10 not capable of properly latching.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 May 2026
Resolved 23 May 2026
Resolution: Vessel fixed fire door.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 25 December 2025
Resolved
15109-The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company. Port State Control Officer responded to a casualty onboard resulting from undetermined processes within the Safety Management System regarding the opening of a confined space and determining the root cause analysis. A safety management external audit carried out by the administration or the RO, with a corresponding report of findings satisfactory to the OCMI, must be submitted prior to clearing this deficiency.
74 SOLAS 20 IX/3.1
ISM Code A.10.1
50abc
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 January 2026
Resolved 30 January 2026
Resolution: External aufit conducted. Survey attached in docs section.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 28 November 2025
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. FPVE observed lifeboat #16's crew unable to secure the vessel's engine without having to use the fuel shut-off valve.
74SOLAS(20)III/20.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 November 2025
Resolution: Rectified during exam.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 28 November 2025
Resolved
All life-saving appliances and arrangements shall comply with the applicable requirements of the Code. The engine shall be capable of operating for not less than 5 min after starting from cold with the lifeboat out of the water. FPVE observed a hydraulic fluid leak on lifeboat #14 rendering the steering gear inoperable.
74SOLAS(20)III/34 LSA Code 4.4.6.3
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 November 2025
Resolution: Rectified during exam.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 30 May 2025
Resolved
Fire detection and fire alarm systems, shall be kept in good order so as to ensure
their required performance if a fire occurs. PSCO observed three inoperable smoke detectors in the Lido Galley on deck 9 and one inoperable smoke detector in engine casing room on deck 6.
74 SOLAS 20 11-2/14.2.1.1.2
16ac
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 June 2025
Resolved 8 June 2025
Resolution: Class verified corrective actions.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 30 May 2025
Resolved
All life saving appliances and arrangements shall comply with the applicable
requirements of the code. The engine shall be capable of operating for not less than 5 minutes after starting from cold with the lifeboat out of the water. PSCO observed the engine on lifeboat 7 and 17 were unable to start
74 SOLAS 20 111/34
LSA 4.4.6.3
17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 30 May 2025
Resolved 30 May 2025
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 30 May 2025
Resolved
Doors and door frames in "B" class division and means of securing them shall
provide a method of closure which shall have resistance to fire equivalent to that of the division. PSCO observed FSD 2.02 on deck A and FSD 5.12 on deck 2 unable to close.
74 SOLAS 97 11-2/31.1
16ac
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2025
Resolved 30 May 2025
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 30 May 2025
Resolved
Fire protection systems and firefighting systems and appliance shall be maintained
and ready for use. PSCO observed fire dampers disconnected from vents (5618.4.226) in space HK07 and inoperable when reconnected.
74 SOLAS 20 1-2/14.1.1
16ac
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2025
Resolved 30 May 2025
01 - Certificates & Documentation › 011 - Ships Certificates › Passenger Ship Safety (including exemption)
Issued 30 May 2025
Resolved
The condition of the ship and its equipment shall be maintained to
confirm with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed an unauthorized container holding hydraulic oil used as an expansion Tank leading to the hydraulic system in space 1/609.
74 SOLAS 97 1-11(a)
16ac
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 June 2025
Resolved 8 June 2025
Resolution: Class verified corrective action.
01 - Certificates & Documentation › 011 - Ships Certificates › Passenger Ship Safety (including exemption)
Issued 30 May 2025
Resolved
The condition of the ship and its equipment shall be maintained to confirm with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without
danger to the ship or persons on board. PSCO observed portable fan tied by rope over the ram fan cooling bearing on the AC unit.
74 SOLAS 97 1-11(a)
16ac
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 June 2025
Resolved 8 June 2025
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 30 May 2025
Resolved
The condition of all doors and door frames in "A" class division, with the means of
securing them when closed, shall provide resistance to fire as well as to the passage of smoke and flame, as far as practical, equivalent to that of the bulkheads in which the doors are situated. PSCO observed FSD 3.02 on tween deck latch but would not seal.
74 SOLAS 97 11-2/30.2
16ac
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 June 2025
Resolved 8 June 2025
Resolution: Class Verified corrective action.
01 - Certificates & Documentation › 011 - Ships Certificates › Passenger Ship Safety (including exemption)
Issued 30 May 2025
Resolved
The condition of the ship and its equipment shall be maintained to confirm with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without
danger to the ship or persons on board. PSCO observed a CO2 extinguisher in location 2/512 and a CO2 extinguisher in location 2/4.02 that were unable to fit in
their appropriate brackets.
74 SOLAS 97 1-11(a)
16ac
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 June 2025
Resolved 8 June 2025
Resolution: Class verified corrective action (replaced extinguishers for ones that brackets were designed for).
01 - Certificates & Documentation › 011 - Ships Certificates › Load Lines (including Exemption)
Issued 30 May 2025
Resolved
The international load line certificate shall not be delivered to the ship until the officer or surveyor acting under the provisions of Article 13 of the present convention have certified that the marks are correctly and permanently indicated on the ships side. PSCO observed that the load line markings on the ship did not
match the markings on the International Load Line Certificate.
ILLC/Reg. 9
50ac
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 June 2025
Resolved 8 June 2025
Resolution: Class verified corrective action.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 30 May 2025
Resolved
The Load Line ring lines and letters shall be painted white or yellow on a dark
background or in black on a light background. PSCO observed the deck line painted white against a white background.
ILLC/ Reg. 8
50ac
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 June 2025
Resolved 8 June 2025
Resolution: Class verified corrective action.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 30 May 2025
Resolved
Fire protection systems and firefighting systems and appliances shall be maintained ready for use. PSCO observed obstructed sprinkler head on deck A by
FSD2.17.
74 SOLAS 20 11-2/14.1.1
10ac
Action required: 10 - Deficiency Rectified
Due 30 May 2025
Resolved 30 May 2025
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 30 May 2025
Resolved
Fire doors in main vertical zone bulkhead and stairway enclosures designed to reopen upon contacting an object in it's path sail reopen sufficiently to allow a clear passage of at least .75m but not more than 1m. PSCO observed inoperable safety
bar on deck 2 FSD 3.03, deck 1 FSD 3.05 deck 5 FSD 3.05, and FSD 5.12.
74 SOLAS 97 11-2/30.4.2
10ac
Action required: 10 - Deficiency Rectified
Due 30 May 2025
Resolved 30 May 2025
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 May 2025
Resolved
Electrical installations shall be such that electrical services for safety will be
ensured under various emergency conditions. PSCO observed unsecured junction box on tender #6.
74 SOLAS 04 11-1/40.1.2
10ac
Action required: 10 - Deficiency Rectified
Due 30 May 2025
Resolved 30 May 2025
09 - Working and Living Conditions › 092 - Working Conditions › Obstruction/slipping, etc.
Issued 30 May 2025
Resolved
The provisions on the prevention of accidents and the protection of health and
employment which may be applicable to the work of seafarers, and shall specify measures for the prevention of accidents which are peculiar to maritime employment. PSCO observed water on the deck outside of the starboard azipod room due to a leaking salt water cooling pipe.
ILO-147/PWSA 33
USC 1223(b)
Accident Prevention/ 2
10ac
Action required: 10 - Deficiency Rectified
Due 30 May 2025
Resolved 30 May 2025
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 3 December 2024
Resolved
Fire doors in main vertical zone bulkheads and stairway enclosures shall be self-closing and shall have an approximately uniform rate of closure of no more than 40 s and no less than 10 s. PSCO observed single leaf door on deck 6, 7.06, in the stairway not latching.
74 SOLAS (97) II-2/30.4.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 December 2024
Resolution: Fire door adjusted to enable proper latching.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 3 December 2024
Resolved
Every crew member with assigned emergency duties shall be familiar with these duties before the voyage begins. Team Leader on lifeboats 11, 15, and 17 were unfamiliar with how to operate Emergency Steering on lifeboats.
74 SOLAS (20) III/19.2.1
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 December 2024
Resolution: Crew members trained in proper emergency steering operation.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 3 December 2024
Resolved
The construction of all doors and door frames in "A" class divisions, with the means of securing them when closed, shall provide resistance to fire as well as to the passage of smoke and flame, as far as practicable, equivalent to that of the bulkheads in which the doors are situated. Such doors and door frames shall be constructed of steel or other equivalent material. PSCO observed FSD Deck TT 4.04 to have two penetrations through the upper horizontal frame of the door.
74 SOLAS (97) II-2/30.2
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 December 2024
Resolved 3 December 2024
Resolution: Received report from RINA showing that the holes have been sealed by stainless steel bolts.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of Lifeboats
Issued 3 December 2024
Resolved
Except in the vicinity of the rudder and propeller, a bouyant lifeline shall be becketed around the outside of the lifeboat. PSCO observed lifeboats 7, 9, and 11 had grablines that were not attached at multiple points.
74 SOLAS (97) III/41.7.3
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 3 December 2024
Resolution: Lifeboat grablines reattached.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 3 December 2024
Resolved
Doorways and corridors and intermediate landings included in means of escape shall be sized in the same manner as stairways. PSCO observed the emergency escape corridor in the spa to be obstructed with a linen cart and trashcan leaving less than 900 mm in clear width.
74 SOLAS (97) II-2/28.1.5.3
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 3 December 2024
Resolution: Linen cart and trashcan removed from space.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 3 December 2024
Resolved
Fire doors in main vertical zone bulkheads and stairway enclosures shall be self-closing and shall have an approximately uniform rate of closure of no more than 40 s and no less than 10 s. PSCO observed FSDs TT 4.04 and TT 2.01 to close faster than ten seconds.
74 SOLAS (97) II-2/30.4.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 3 December 2024
Resolution: FSDs adjusted to meet proper closure rate.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 3 December 2024
Resolved
Doors and door frames in "'B" class divisions and means of securing them shall provide a method of closure which shall have resistance to fire equivalent to that of the division. PSCO observed 03 doors not completely closing: FSD DECK 6, 1.02, FANSPACE; FSD DECK 6, 3.03, PLUMBERS STORE; and FSD DECK 6, 3.05, HOUSE KEEPERS CLOSET.
74 SOLAS (97) II-2/31.1.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 3 December 2024
Resolution: FSDs adjusted to enable proper closure ability.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 3 December 2024
Resolved
All waste-receptacles shall be constructed of non-combustible materials with no openings in the sides or bottom. PSCO observed combustibles in plastic bin.
74 SOLAS (97) II-2/18.5
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 3 December 2024
Resolution: Plastic bin exchanged for metal trash can.