MARGARITAVILLE AT SEA ISLANDER

MARGARITAVILLE AT SEA ISLANDER is a 2000 passenger vessel (inspected). The Coast Guard has recorded 45 inspections since 2001, most recently in May 2026, along with 39 deficiencies and 3 operational controls.

Records from 2001 to 2026. Most recent: inspection, 23 May 2026.

Built
2000
Last inspected
23 May 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9187796 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
BAHAMAS, THE
—
Maury page id
psix-16545

Inspections, by type

…with no type recorded10
Years with a record 11 calendar years (2001–2026)
The 45 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it85861 - Convention (Subpart B), Gross Ton
53578 - Convention (Subpart B), Net Ton
8600 - Dead Weight, Ton
43437 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

DOUBLE SKIN 301 Tank Barge · MISLE 894685 · 19 September 2010 · activity 3880503GEORGE HOLLAND Towing Vessel · MISLE 926617 · 19 September 2010 · activity 3880503

Inspection history · 45

23 May 2026 PSC A · COC-CVE Annual
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8372524
30 January 2026 Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8303914
28 December 2025 Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8287757
25 December 2025 ISM Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8287241
28 November 2025 COC-CVE Quarterly · PSC B
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8274728
17 November 2025 Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8269854
10 November 2025 Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8266946
10 October 2025 Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8250372
25 September 2025 Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8241171
11 September 2025 Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8231635
28 August 2025 Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8219717
31 July 2025 Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8199358
28 July 2025 Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8196431
20 July 2025 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8191950
17 July 2025 Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8188081
14 July 2025 Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8185627
4 July 2025 Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8175028
19 June 2025 Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8162708
16 June 2025 Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8160052
5 June 2025 Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8153106
31 May 2025 Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8153093
30 May 2025 PSC A · COC-CVE Annual
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8139671
6 February 2025 MARPOL Annex I Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8077163
3 December 2024 COC-CVE Quarterly · PSC B
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8040788
5 June 2024 PSC A · COC-CVE Annual
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7923260
25 February 2024 COC-CVE Initial · COC-CVE Initial Prep
Administrative · Activities Europe · Activity 7893423
6 December 2016 MARPOL Annex I Examination · ISPS II Exam · STCW 95 Exam · Ballast Water Examination · MARPOL Annex V Examination · ILO-147 Exam · COC-CVE Annual
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6051855
19 December 2011 COC-CVE Annual · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4207096
23 February 2011 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3950560
18 February 2011 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3948008
2 January 2011 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3919281
6 November 2010 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3885991
6 November 2010 In-Service Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3886145
29 October 2010 Type not recorded
No type recorded · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 3878022
12 October 2010 COC-CVE Annual · Deficiency Check · PII Safety Exam · MARPOL Annex V Examination · ISPS II Exam · MARPOL Annex I Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3868554
23 September 2010 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3854225
19 September 2010 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3880503
10 January 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2271874
2 December 2004 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2269090
18 November 2004 Ballast Water Examination · COC-CVE Annual · ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2243368
28 January 2004 Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 1995188
21 December 2003 Certificate of Compliance
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1965157
24 November 2002 Deficiency Check · Certificate of Compliance
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1708720
9 December 2001 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1076912
7 February 2001 Quarterly Examination · Deficiency Check · MARPOL Annex I Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1423513

Deficiency record · 39

07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 May 2026 Resolved
The condition of the ship and its equipment shall be maintained to conform to with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or person on board. Oxygen and nitrogen bottles on the aft mooring deck were not properly stored off the deck.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 May 2026
Resolved 23 May 2026
Resolution: Moved oxygen on a pallet.
11 - Life Saving Appliances › N/A - No Subsystem › Embarkation arrangement survival craft
Issued 23 May 2026 Resolved
Muster and embarkation stations shall be adequately illuminated by lighting supplied from the emergency source of electrical power required by regulation II- I/42 or II-1/43. PSCO observed non-operational emergency lighting forward of lifeboat #16 and #18.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 May 2026
Resolved 23 May 2026
Resolution: Vessel replaced lights.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 23 May 2026 Resolved
All doors shall be capable of remote and automatic release from a continuously manned central control station, either simultaneously or in groups, and also individually from a position at both sides of the door. Indication must be provided at the fire control panel in the continuously manned central control station whether each of the remote-controlled doors are closed. The release mechanism shall be so designed that the door will automatically close in the event of disruption of the control system or central power supply. Release switches shall have an on off function to prevent automatic resetting of the system. Hold-back hooks not subject to central control station release are prohibited. PSCO observed galley fire door 3.14 on deck 10 not capable of properly latching.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 May 2026
Resolved 23 May 2026
Resolution: Vessel fixed fire door.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 25 December 2025 Resolved
15109-The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company. Port State Control Officer responded to a casualty onboard resulting from undetermined processes within the Safety Management System regarding the opening of a confined space and determining the root cause analysis. A safety management external audit carried out by the administration or the RO, with a corresponding report of findings satisfactory to the OCMI, must be submitted prior to clearing this deficiency. 74 SOLAS 20 IX/3.1 ISM Code A.10.1 50abc
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 January 2026
Resolved 30 January 2026
Resolution: External aufit conducted. Survey attached in docs section.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 28 November 2025 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. FPVE observed lifeboat #16's crew unable to secure the vessel's engine without having to use the fuel shut-off valve. 74SOLAS(20)III/20.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 November 2025
Resolution: Rectified during exam.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 28 November 2025 Resolved
All life-saving appliances and arrangements shall comply with the applicable requirements of the Code. The engine shall be capable of operating for not less than 5 min after starting from cold with the lifeboat out of the water. FPVE observed a hydraulic fluid leak on lifeboat #14 rendering the steering gear inoperable. 74SOLAS(20)III/34 LSA Code 4.4.6.3
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 November 2025
Resolution: Rectified during exam.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 30 May 2025 Resolved
Fire detection and fire alarm systems, shall be kept in good order so as to ensure their required performance if a fire occurs. PSCO observed three inoperable smoke detectors in the Lido Galley on deck 9 and one inoperable smoke detector in engine casing room on deck 6. 74 SOLAS 20 11-2/14.2.1.1.2 16ac
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 June 2025
Resolved 8 June 2025
Resolution: Class verified corrective actions.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 30 May 2025 Resolved
All life saving appliances and arrangements shall comply with the applicable requirements of the code. The engine shall be capable of operating for not less than 5 minutes after starting from cold with the lifeboat out of the water. PSCO observed the engine on lifeboat 7 and 17 were unable to start 74 SOLAS 20 111/34 LSA 4.4.6.3 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 30 May 2025
Resolved 30 May 2025
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 30 May 2025 Resolved
Doors and door frames in "B" class division and means of securing them shall provide a method of closure which shall have resistance to fire equivalent to that of the division. PSCO observed FSD 2.02 on deck A and FSD 5.12 on deck 2 unable to close. 74 SOLAS 97 11-2/31.1 16ac
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2025
Resolved 30 May 2025
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 30 May 2025 Resolved
Fire protection systems and firefighting systems and appliance shall be maintained and ready for use. PSCO observed fire dampers disconnected from vents (5618.4.226) in space HK07 and inoperable when reconnected. 74 SOLAS 20 1-2/14.1.1 16ac
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2025
Resolved 30 May 2025
01 - Certificates & Documentation › 011 - Ships Certificates › Passenger Ship Safety (including exemption)
Issued 30 May 2025 Resolved
The condition of the ship and its equipment shall be maintained to confirm with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed an unauthorized container holding hydraulic oil used as an expansion Tank leading to the hydraulic system in space 1/609. 74 SOLAS 97 1-11(a) 16ac
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 June 2025
Resolved 8 June 2025
Resolution: Class verified corrective action.
01 - Certificates & Documentation › 011 - Ships Certificates › Passenger Ship Safety (including exemption)
Issued 30 May 2025 Resolved
The condition of the ship and its equipment shall be maintained to confirm with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed portable fan tied by rope over the ram fan cooling bearing on the AC unit. 74 SOLAS 97 1-11(a) 16ac
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 June 2025
Resolved 8 June 2025
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 30 May 2025 Resolved
The condition of all doors and door frames in "A" class division, with the means of securing them when closed, shall provide resistance to fire as well as to the passage of smoke and flame, as far as practical, equivalent to that of the bulkheads in which the doors are situated. PSCO observed FSD 3.02 on tween deck latch but would not seal. 74 SOLAS 97 11-2/30.2 16ac
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 June 2025
Resolved 8 June 2025
Resolution: Class Verified corrective action.
01 - Certificates & Documentation › 011 - Ships Certificates › Passenger Ship Safety (including exemption)
Issued 30 May 2025 Resolved
The condition of the ship and its equipment shall be maintained to confirm with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed a CO2 extinguisher in location 2/512 and a CO2 extinguisher in location 2/4.02 that were unable to fit in their appropriate brackets. 74 SOLAS 97 1-11(a) 16ac
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 June 2025
Resolved 8 June 2025
Resolution: Class verified corrective action (replaced extinguishers for ones that brackets were designed for).
01 - Certificates & Documentation › 011 - Ships Certificates › Load Lines (including Exemption)
Issued 30 May 2025 Resolved
The international load line certificate shall not be delivered to the ship until the officer or surveyor acting under the provisions of Article 13 of the present convention have certified that the marks are correctly and permanently indicated on the ships side. PSCO observed that the load line markings on the ship did not match the markings on the International Load Line Certificate. ILLC/Reg. 9 50ac
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 June 2025
Resolved 8 June 2025
Resolution: Class verified corrective action.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 30 May 2025 Resolved
The Load Line ring lines and letters shall be painted white or yellow on a dark background or in black on a light background. PSCO observed the deck line painted white against a white background. ILLC/ Reg. 8 50ac
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 June 2025
Resolved 8 June 2025
Resolution: Class verified corrective action.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 30 May 2025 Resolved
Fire protection systems and firefighting systems and appliances shall be maintained ready for use. PSCO observed obstructed sprinkler head on deck A by FSD2.17. 74 SOLAS 20 11-2/14.1.1 10ac
Action required: 10 - Deficiency Rectified
Due 30 May 2025
Resolved 30 May 2025
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 30 May 2025 Resolved
Fire doors in main vertical zone bulkhead and stairway enclosures designed to reopen upon contacting an object in it's path sail reopen sufficiently to allow a clear passage of at least .75m but not more than 1m. PSCO observed inoperable safety bar on deck 2 FSD 3.03, deck 1 FSD 3.05 deck 5 FSD 3.05, and FSD 5.12. 74 SOLAS 97 11-2/30.4.2 10ac
Action required: 10 - Deficiency Rectified
Due 30 May 2025
Resolved 30 May 2025
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 May 2025 Resolved
Electrical installations shall be such that electrical services for safety will be ensured under various emergency conditions. PSCO observed unsecured junction box on tender #6. 74 SOLAS 04 11-1/40.1.2 10ac
Action required: 10 - Deficiency Rectified
Due 30 May 2025
Resolved 30 May 2025
09 - Working and Living Conditions › 092 - Working Conditions › Obstruction/slipping, etc.
Issued 30 May 2025 Resolved
The provisions on the prevention of accidents and the protection of health and employment which may be applicable to the work of seafarers, and shall specify measures for the prevention of accidents which are peculiar to maritime employment. PSCO observed water on the deck outside of the starboard azipod room due to a leaking salt water cooling pipe. ILO-147/PWSA 33 USC 1223(b) Accident Prevention/ 2 10ac
Action required: 10 - Deficiency Rectified
Due 30 May 2025
Resolved 30 May 2025
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 3 December 2024 Resolved
Fire doors in main vertical zone bulkheads and stairway enclosures shall be self-closing and shall have an approximately uniform rate of closure of no more than 40 s and no less than 10 s. PSCO observed single leaf door on deck 6, 7.06, in the stairway not latching. 74 SOLAS (97) II-2/30.4.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 December 2024
Resolution: Fire door adjusted to enable proper latching.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 3 December 2024 Resolved
Every crew member with assigned emergency duties shall be familiar with these duties before the voyage begins. Team Leader on lifeboats 11, 15, and 17 were unfamiliar with how to operate Emergency Steering on lifeboats. 74 SOLAS (20) III/19.2.1
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 December 2024
Resolution: Crew members trained in proper emergency steering operation.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 3 December 2024 Resolved
The construction of all doors and door frames in "A" class divisions, with the means of securing them when closed, shall provide resistance to fire as well as to the passage of smoke and flame, as far as practicable, equivalent to that of the bulkheads in which the doors are situated. Such doors and door frames shall be constructed of steel or other equivalent material. PSCO observed FSD Deck TT 4.04 to have two penetrations through the upper horizontal frame of the door. 74 SOLAS (97) II-2/30.2
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 December 2024
Resolved 3 December 2024
Resolution: Received report from RINA showing that the holes have been sealed by stainless steel bolts.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of Lifeboats
Issued 3 December 2024 Resolved
Except in the vicinity of the rudder and propeller, a bouyant lifeline shall be becketed around the outside of the lifeboat. PSCO observed lifeboats 7, 9, and 11 had grablines that were not attached at multiple points. 74 SOLAS (97) III/41.7.3
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 3 December 2024
Resolution: Lifeboat grablines reattached.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 3 December 2024 Resolved
Doorways and corridors and intermediate landings included in means of escape shall be sized in the same manner as stairways. PSCO observed the emergency escape corridor in the spa to be obstructed with a linen cart and trashcan leaving less than 900 mm in clear width. 74 SOLAS (97) II-2/28.1.5.3
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 3 December 2024
Resolution: Linen cart and trashcan removed from space.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 3 December 2024 Resolved
Fire doors in main vertical zone bulkheads and stairway enclosures shall be self-closing and shall have an approximately uniform rate of closure of no more than 40 s and no less than 10 s. PSCO observed FSDs TT 4.04 and TT 2.01 to close faster than ten seconds. 74 SOLAS (97) II-2/30.4.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 3 December 2024
Resolution: FSDs adjusted to meet proper closure rate.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 3 December 2024 Resolved
Doors and door frames in "'B" class divisions and means of securing them shall provide a method of closure which shall have resistance to fire equivalent to that of the division. PSCO observed 03 doors not completely closing: FSD DECK 6, 1.02, FANSPACE; FSD DECK 6, 3.03, PLUMBERS STORE; and FSD DECK 6, 3.05, HOUSE KEEPERS CLOSET. 74 SOLAS (97) II-2/31.1.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 3 December 2024
Resolution: FSDs adjusted to enable proper closure ability.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 3 December 2024 Resolved
All waste-receptacles shall be constructed of non-combustible materials with no openings in the sides or bottom. PSCO observed combustibles in plastic bin. 74 SOLAS (97) II-2/18.5
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 3 December 2024
Resolution: Plastic bin exchanged for metal trash can.
Engineering › Steam System (auxiliary) › Piping
Issued 12 October 2010 Resolved
During PSC USCG COC-CVE exam, it was noted that boiler blow down (BBD) valve #'s1 and 2 were leaking excessively and cracked. Repair the same
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 November 2010
Resolution: Received class attesting to replacement of said BBD valves.
Engineering › Steering Gear System › Hydraulic Hose
Issued 12 October 2010 Resolved
Various HP Hyd (1 1/2 inch) flex hoses have soft spots/bulges (IWO azipod system located in aft steering rooms P/S) Class surveyor is to attest to satisfactory condition of said hoses.
Action required: 705 - Other - as specified
Resolved 14 November 2010
Resolution: Vessels class attested to condition of hoses as being outer layer of hoses and ok''ed for service until next DD period of vessel Dec 2010. At that time the hoses will be reevaluated as to condition as per manufacture.
Lifesaving › Lifeboat › Hull
Issued 12 October 2010 Resolved
LB/Tender #5 has a temp patch repair on its stbd hull located under water line. vessels class surveyor is to attest to effectiveness of said patch.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 October 2010
Resolution: Vessels class surveyor confirmed patch is sat and relayed that LB is fit for its intended service.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 12 October 2010 Resolved
Galley roller shutter on deck 8 MVZ #4 (located in area of pool) has the ability not to close all the way if the warming station door is open when the door is activated. Vessels class society must approve the adequacy of the door.
Due 13 November 2010
Resolved 3 January 2020
Resolution: Fire shutters system for the warming stations has been approved by the vsls flag state. Master has additionally placed placards to keep doors in ready condition in regards to this item.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 28 January 2004 Resolved
Provide proof that Class accepts the current modification (welded closed) to rolling fire screen shutter "3.06" on Deck 10, Atlantica Lounge, verified all applicable affected machinery/equipment has been permanently disconnected, re-categorized the space and updated the vessels Fire Control Plan. LEGACY COMPONENT DESC: Openings - Fire Doors
Action required: 705 - Other - as specified
Due 5 May 2004
Resolved 18 November 2004
Resolution: Received proof of Class acceptance. Updated Fire Control Plan in progress.
Fire Fighting › Structural - A Class Divisions
Issued 21 December 2003 Resolved
Properly repair rolling fire screen shutter "3.06" on deck 10 atlantica lounge to the satisfaction of class prior to 21JAN04. LEGACY COMPONENT DESC: Openings - Fire Doors
Due 21 January 2004
Resolved 28 January 2004
Resolution: Subject shutter is welded closed and affected equipment has power disconnected. Cleared this requirement to re-issue another due to the temporary repair.
Deck/Cargo › Cargo Stowage
Issued 21 November 2002 Resolved
Vessel has no plan or designated area for hazardous waste waiting to be discharged ashore. Presently waste is being stowed in carts in Marshalling Area. Identify storage area with proper safety equipment and have class re-designate space and provide report to USCG Marine Safety Office. LEGACY COMPONENT DESC: HAZMAT
Due 15 December 2002
Resolved 1 December 2002
Lifesaving › Lifejacket/PFD (General)
Issued 21 November 2002 Resolved
Mark all stowage locations containing lifesaving appliances with correct symbols and quantity of appliances contained within. Florian Room has child lifejackets stowed in cabinet with adult symbol and no quanity. LEGACY COMPONENT DESC: Storage
Due 15 December 2002
Resolved 1 December 2002
Fire Fighting › Structural - A Class Divisions
Issued 21 November 2002 Resolved
Locks on FSD and exits are in need of repairs throughout vessel. Remove all locks not needed for security. Ensure all other locks/tumblers work properly from the exit/emergency side. Ensure locks are on or added to a maintenance schedule to satisfaction of class and provide report to MSO Miami. LEGACY COMPONENT DESC: Openings - Fire Doors
Due 15 December 2002
Resolved 1 December 2002
Lifesaving › Lifeboat
Issued 21 November 2002 Resolved
Provide procedure for securing life boats and properly adjusting bowsing tackel to satisfaction of attending USCG Inspector. LEGACY COMPONENT DESC: Instructions
Due 8 December 2002
Resolved 8 December 2002
Lifesaving › Inflatable Liferafts
Issued 21 November 2002 Resolved
Conduct davit launch raft drill to satisfaction of USCG attending Inspector.
Due 8 December 2002
Resolved 8 December 2002

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.