Inspection history · 55
9 December 2025
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8270187
4 December 2024
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8029357
8 March 2024
Hull Examination · Internal Structural Exam · Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7873765
9 February 2024
Annual Inspection · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7863512
2 November 2022
Deficiency Check · COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7587083
16 November 2021
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7351815
18 January 2021
Type not recorded
No type recorded · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7126184
18 January 2021
Deficiency Check
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7126304
13 February 2019
Administrative Inspection · Initial Certification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6625172
29 September 2018
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6552331
20 May 2018
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6427005
6 November 2017
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6310357
4 May 2017
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6166804
12 January 2015
Type not recorded
No type recorded · Station Lake Charles · USCG Heartland District (CGD-H) · Activity 5052991
7 October 2014
Type not recorded
No type recorded · Station New Orleans · USCG Heartland District (CGD-H) · Activity 5001717
13 August 2014
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4954895
24 July 2013
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 4668612
8 May 2011
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4007318
18 November 2010
MTSA Verification · Industry Initiated Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3896746
22 March 2010
Type not recorded
No type recorded · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 3701954
6 January 2010
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3662600
23 July 2009
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3543336
3 April 2009
Type not recorded
No type recorded · Station New Orleans · USCG Heartland District (CGD-H) · Activity 3446405
19 January 2009
Administration
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3396526
19 November 2008
Administration · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3365886
19 November 2008
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3365921
22 April 2008
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3189723
18 April 2008
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3189577
20 July 2007
Type not recorded
No type recorded · Station New Orleans · USCG Heartland District (CGD-H) · Activity 3009691
15 September 2006
Annual Inspection · Deficiency Check · MTSA Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2778875
22 April 2005
Administrative Inspection
Administrative · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 2340516
27 December 2004
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1973141
21 September 2004
MTSA Verification
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2201107
2 July 2004
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2148795
29 May 2004
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2086694
27 January 2004
Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1993708
20 January 2004
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1988777
20 January 2004
Type not recorded
No type recorded · Station Port Aransas · USCG Heartland District (CGD-H) · Activity 1989083
12 January 2004
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1982155
22 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1978189
22 November 2002
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1709482
7 November 2002
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1709467
28 August 2001
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 771234
23 August 2001
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 211557
23 June 2001
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 90551
8 December 2000
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 766274
23 November 2000
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 211552
7 November 1999
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 28792
22 June 1999
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 177444
4 December 1998
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 50725
22 November 1998
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 153149
15 December 1997
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 411024
29 July 1995
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 108691
3 February 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 73012
3 February 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 156918
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 December 2025
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Marine inspector observed open electrical junction boxes in engine room. Install covers on electrical junction boxes.
46 CFR 143.400 (a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 December 2025
Resolved 5 January 2026
Resolution: O/O provided images of new electrical junction box covers installed.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 9 December 2025
Resolved
Each towing vessel must perform Test of Alarm setpoints at a frequency of Twice every 5 years. Marine inspector observed the vessel did not have a test procedure in place to test operation of the main engine high cooling water temperature. Develop test/ record procedure of testing high coolant water temperature alarm and all other alarm set points.
46 CFR 143.245 (b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 December 2025
Resolved 5 January 2026
Resolution: O/O provided copies of new record log/procedures and testing of the alarm set points.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 9 December 2025
Resolved
Each towing vessel must perform Test of pressure vessel relief valves at a frequency of Twice every 5 years. Vessel could not provide last testing of pressure relief valves for the pressure vessels. Install new or test certified pressure relief valves.
46 CFR 143.245 (b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 December 2025
Resolved 12 December 2025
Resolution: Vessel rep provided photo documentation of new PRV's installed. Sat
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 9 December 2025
Resolved
Each towing vessel equipped with rudder(s) must have a means to monitor and control the position of the rudder(s) at each operating station. Marine inspector observed the rudder angle indicator was inoperable. Repair rudder angle indicator must be repaired to proper operation.
46 CFR 143.225 (b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 December 2025
Resolved 12 December 2025
Resolution: Vessel rep provided video documentation of rudder angle indicator operating. Sat
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 9 December 2025
Resolved
Each remote valve control must be marked in clearly legible letters, at least 25 millimeters (1 inch) high, indicating the purpose of the valve and the way to operate it. Marine inspector observed the remote valve control for the fuel shutoffs were illegible. Re-apply markings per the CFR.
46 CFR 143.260 (e)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 December 2025
Resolved 12 December 2025
Resolution: Vessel rep provided photo documentation of new fuel shut-off markings. Sat.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 9 December 2025
Resolved
Towing vessels must meet the communications requirements of 33 CFR part 26 and 33 CFR 164.72, as applicable. Vessels VHF did not have MMSI or GPS programmed in. Program in the MMSI and GPS for DSC.
46 CFR 140.715 (a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 December 2025
Resolved 5 January 2026
Resolution: O/O operator provided images and documents of new radio installed with programmed MMSI.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 16 February 2024
Resolved
Essential systems or equipment must be regularly tested and examined. Tests and examinations must verify that the system or equipment functions as designed. If a component is found unsatisfactory, it must be repaired or replaced.
MI found pressure relief valves on both the pressure vessel and compressor had not been tested since 2020.
46 CFR 143.245(a)
Action required: 17 - Rectify deficiencies prior to departure
Due 16 February 2024
Resolved 16 February 2024
Resolution: New safety relief valves were installed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 16 February 2024
Resolved
All fire-suppression and detection equipment and systems on board a towing vessel must be maintained in accordance with the attached nameplate, manufacturer's approved design manual, or as otherwise provided in any TSMS applicable to the vessel.
MI observed that 160-B was expired.
46 CFR 142.240(b)
Action required: 17 - Rectify deficiencies prior to departure
Due 16 February 2024
Resolved 16 February 2024
Resolution: New 160-B installed on board.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage discharge connection
Issued 16 February 2024
Resolved
When operating a vessel on a body of water where the discharge of treated or untreated sewage is prohibited by the Environmental Protection Agency under 40 CFR 140.3 or 140.4, the operator must secure each Type I or Type II device in a manner which prevents discharge of treated or untreated sewage.
MI observed that the overboard discharge was not secured.
Action required: 17 - Rectify deficiencies prior to departure
Due 16 February 2024
Resolved 16 February 2024
Resolution: Overboard discharge valve was locked.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 February 2024
Resolved
All training required in this section must be documented in owner or managing operator's records.
Owner did not have record of health and safety refresher training.
46 CFR 140.515(f)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 March 2024
Resolved 11 April 2024
Resolution: Training plan submitted for vessel crew.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 February 2024
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions.
Vessel had dead end wire in the upper machinery space.
Rectify within 7 days.
46 CFR 143.205
Action required: 705 - Other - as specified
Due 23 February 2024
Resolved 11 April 2024
Resolution: Dead end wire secured.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 16 February 2024
Resolved
All machinery and equipment that is not in proper working order (including missing or malfunctioning guards or safety devices) must be removed; made safe through marking, tagging, or covering; or otherwise made unusable.
MI observed an AED that had not been serviced or trained with that was not tagged out.
46 CFR 140.505(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 March 2024
Resolved 11 April 2024
Resolution: AED has been properly tagged out.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 9 February 2024
Resolved
Each towing vessel certificated under the provisions of this subchapter must be in full compliance with the terms of the COI.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 February 2024
Resolved 16 February 2024
Resolution: Completed annual inspection.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 February 2024
Resolved
All vessel equipment must be used in accordance with the manufacturer's recommended practice and in a manner that minimizes risk of injury or death. This includes machinery, deck machinery, towing gear, ladders, embarkation devices, cranes, portable tools, and safety equipment.
MI observed that TVR had a section for the aft skiff to be inspected, which had not been done for several years. The skiff either needs to be inspected IAW the TVR or removed from the vessel.
46 CFR 140.505
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 March 2024
Resolved 11 April 2024
Resolution: Skiff has been tagged out and will be removed from vessel.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 2 November 2022
Resolved
The following list of items must be recorded in the TVR, official logbook, or in accordance with the TSMS applicable to the vessel:
(1) Personnel records, in accordance with § 140.400;
(2) Safety orientation, in accordance with § 140.410;
(3) Record of drills and instruction, in accordance with § 140.420;
(4) Examinations and tests, in accordance with § 140.615;
(5) Operative navigational safety equipment, in accordance with § 140.620;
(6) Navigation assessment, in accordance with § 140.635;
(7) Navigation safety training, in accordance with § 140.645;
(8) Oil residue discharges and disposals, in accordance with § 140.655;
(9) Record of inspection of towing gear, in accordance with § 140.820; and
(10) Fire-detection and fixed fire-extinguishing, in accordance with § 142.240.
None of the items to be recorded were found onboard the vessel or completed by the new owner.
46 CFR 140.915(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 December 2022
Resolved 18 November 2022
Resolution: All records required by 46 CFR 140.915(a) are now logged and onboard.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 2 November 2022
Resolved
A towing vessel must carry adequate and up-to-date charts, maps, and nautical publications for the intended voyage.
The vessel does not have charts for Tampa Bay onboard.
46 CFR 140.705
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 November 2022
Resolved 18 November 2022
Resolution: An up-to-date chart for Tampa Bay was found on the bridge.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 2 November 2022
Resolved
A towing vessel of 26 feet or more in length and more than 600 horsepower, engaged in commercial service must have on board a properly installed, operational Coast Guard type-approved AIS device.
The AIS device found onboard was not transmitting the vessel's position to the other AIS devices.
33 CFR 164.46
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 November 2022
Resolved 18 November 2022
Resolution: The AIS was found disconnected from the antenna. The operator reconnected the antenna and the AIS functions as intended.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 2 November 2022
Resolved
Each towing vessel must be fitted with a general alarm that complies with 46 CFR 143.235.
The general alarm was found inoperable when tested.
46 CFR 143.235
Action required: 17 - Rectify deficiencies prior to departure
Due 2 November 2022
Resolved 18 November 2022
Resolution: The general alarm was tested and found operational.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 2 November 2022
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions.
The port and starboard generators were not operational during the inspection. The operator will prove proper operation of the generators prior to receiving a new COI.
46 CFR 143.205
Action required: 17 - Rectify deficiencies prior to departure
Due 2 November 2022
Resolved 18 November 2022
Resolution: The port and starboard generators were witnessed in operation while under load with no deficiencies noted.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 2 November 2022
Resolved
Survival craft must be stowed in accordance with the requirements of § 199.130 of this chapter, as far as is practicable on existing towing vessels.
The operator elected to use a combination of survival craft for the 8 total persons permitted onboard. A 4 person skiff that meets requirements in § 141.330(a) through (f) is onboard and a 4 person SOLAS B life raft is onboard. The life raft is not mounted and the hydro static release is not connected to the unit.
46 CFR 141.310
Action required: 17 - Rectify deficiencies prior to departure
Due 2 November 2022
Resolved 18 November 2022
Resolution: The liferaft was found permanently mounted to the starboard 2nd deck and connected to a hydro release unit.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 2 November 2022
Resolved
Each towing vessel must have either a self-priming, power-driven, fixed fire pump, a fire main, and hoses and nozzles in accordance with paragraphs (a) through (d) of this section; or a portable pump, and hoses and nozzles, in accordance with paragraphs (e) and (f) of this section.
The fire pump was not self priming and could not be energized from outside of the space due to the sea water pick-up valve being closed. The valve handle was missing and the valve could not be opened without the use of additional tools.
46 CFR 142.325
Action required: 17 - Rectify deficiencies prior to departure
Due 2 November 2022
Resolved 18 November 2022
Resolution: The fire pump valve handle was renewed and the fire pump operates as intended.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 2 November 2022
Resolved
All seals and gaskets must be properly maintained to prevent leaks of flammable or combustible liquid, as those terms are defined in 46 CFR subpart 30.10, into the machinery space.
The flexible hose fitting on the starboard main engine was found leaking diesel fuel when in operation.
46 CFR 143.220
Action required: 17 - Rectify deficiencies prior to departure
Due 2 November 2022
Resolved 18 November 2022
Resolution: The main engine was operationally tested and found without any fuel leaks.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 2 November 2022
Resolved
Means must be provided for stopping each fan in a ventilation system serving machinery spaces and for closing, in case of fire, each doorway, ventilator, and annular space around funnels and other openings into such spaces.
The two aft ventilation fans for the engine space do not have closing devices that seal the opening in case of fire.
46 CFR 144.605
Action required: 17 - Rectify deficiencies prior to departure
Due 2 November 2022
Resolved 18 November 2022
Resolution: The two aft ventilation fans for the engine space are sealed and outfitted with closing devices.
99 - Other › N/A - No Subsystem › Other (MARPOL operational)
Issued 2 November 2022
Resolved
All bilges and void spaces are kept free from accumulation of combustible and flammable materials and liquids insofar as practicable.
The engine room bilge was found with approximately 1 foot of oily bilge water throughout and the MI was unable to witness a test of the bilge pumping system without creating a pollution incident.
The operator shall remove all oily bilge water and dispose of it IAW all applicable laws. The operator shall test the bilge pump in the presence of the attending MI once the bilge is clean.
46 CFR 142.220
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 December 2022
Resolved 18 November 2022
Resolution: The bilge was pumped by a third party and properly disposed of. The bilge pump manifold tested and found operational.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 2 November 2022
Resolved
Emergency lighting must be provided for all internal crew working and living areas. Emergency lighting sources must provide for sufficient illumination under emergency conditions to facilitate egress from each space.
The emergency lighting in the engine room is not sufficient and does not illuminate the egress path out of the engine room.
46 CFR 143.410
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 November 2022
Resolved 18 November 2022
Resolution: The operator added three additional emergency lights in the engine room.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 2 November 2022
Resolved
A 40-B portable fire extinguisher must be located near the storage room or cabinet for storage of flammable or combustible products.
The vessel is outfitted with two flammable storage cabinets which contain gasoline and flammable paint.
An additional 40-B portable extinguisher is required for the second storage cabinet.
46 CFR 142.225
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 November 2022
Resolved 18 November 2022
Resolution: An additional 40-B portable extinguisher was found next to the second storage cabinet.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 November 2022
Resolved
All pressure vessels must have the MAWP indicated by a stamp, nameplate, or other means visible to the crew.
The starboard pressure vessel data plate is not legible due to excessive paint.
46 CFR 143.300
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 November 2022
Resolved 18 November 2022
Resolution: The data plate for the pressure vessel was found clean and legible.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 2 November 2022
Resolved
Closure devices must be provided for deckhouse or hull penetrations, which open to the exterior of the vessel and which may allow water to enter the vessel.
Electrical penetrations in the engine room aft bulkhead on the main deck were found unsealed and provide access for water to enter the engine room space.
46 CFR 144.320
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 November 2022
Resolved 18 November 2022
Resolution: Electrical penetrations in the engine room aft bulkhead on the main deck were found sealed.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 2 November 2022
Resolved
Prior to assuming duties related to the safe operation of a towing vessel, each crewmember must receive training to ensure that they are familiar with: Watchstanding terms and definitions; Duties of a lookout; Communication with other watchstanders; Change of watch procedures; Procedures for reporting other vessels or objects; and Watchstanding safety. Crewmember training must be recorded in the TVR, official logbook, or in accordance with the TSMS applicable to the vessel.
The new crewmembers onboard did not complete the navigation safety training prior to assuming duties onboard. The training is not logged.
46 CFR 140.645
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 November 2022
Resolved 18 November 2022
Resolution: The new crewmembers onboard completed the navigation safety training prior to assuming duties onboard and the training was logged.
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 15 September 2006
Resolved
The control panel and operating station alarm panel displayed a trouble alarm and could not be tested. 46 CFR 27.201
Action required: 705 - Other - as specified
Due 22 September 2006
Resolved 24 October 2006
Resolution: Repairs made by Safety Controls, Inc.
Lifesaving › Lifebuoys
Issued 27 January 2004
Resolved
Name of vessel not present on liferings. LEGACY COMPONENT DESC: Markings (ship name/port)
Action required: 705 - Other - as specified
Due 9 February 2004
Resolved 9 March 2004
Resolution: Name of vessel placed on liferings.
Operations/Management › Navigation Safety
Issued 27 January 2004
Resolved
Navigational charts not updated. LEGACY COMPONENT DESC: Carriage of Charts and Publications
Action required: 705 - Other - as specified
Due 9 February 2004
Resolved 9 March 2004
Resolution: Brand new charts purchased and onboard vessel.
Pollution Prevention/Response › Prevention Equipment
Issued 27 January 2004
Resolved
Operating instructions/safety procedures not posted on MSD. LEGACY COMPONENT DESC: Marine Sanitation Device, Type II
Action required: 705 - Other - as specified
Due 9 February 2004
Resolved 1 April 2004
Resolution: Operating instructions/safety procedures placed on MSD.
Documentation › Certificates/Documents
Issued 27 January 2004
Resolved
No radio operators license held by anyone on board the vessel.
Action required: 705 - Other - as specified
Due 9 February 2004
Resolved 1 April 2004
Resolution: Radio operators license ordered by captain of vessel.