MAURY USCG vessel records Sign in
← All vessels

CORY MICHAEL

CORY MICHAEL is a 1970 towing vessel. The Coast Guard has recorded 22 inspections since 1998, most recently in February 2022, along with 27 deficiencies and 4 casualty investigations between 2005 and 2014.

Records from 1998 to 2022. Most recent: inspection, 3 February 2022.

Built
1970
Last inspected
3 February 2022
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDI3858
106082
Flag
UNITED STATES
367021870 (licence lapsed)
Maury page id
psix-106082

Inspections, by type

…with no type recorded14
Years with a record 15 calendar years (1998–2022)
The 22 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Documentation record

Registered dimensions (L × B × D)59.5 ft × 23.0 ft × 8.0 ft
Registered tonnagegross 93 / net 63
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderUNIVERSAL IRON WORKS · HOUMA, LA, UNITED STATES · built 1970
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it93 - Regulatory (Subpart C or D), Gross Ton
63 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDI3858MMSI 367021870 · expired · compulsorily equipped · granted 19 September 2015, cancelled 7 March 2026
WDC4262MMSI 367021870 · expired · compulsorily equipped · granted 3 March 2005, cancelled 9 May 2015
WCK3231MMSI not assigned · expired · compulsorily equipped · granted 28 July 1994, cancelled 2 October 2004
WAB7645MMSI not assigned · expired · voluntarily equipped · granted 31 March 1994, cancelled 29 August 2004 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 5

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

EMILY Freight Barge · MISLE 52125 · 13 August 2014 · activity 4954895TROY JACOB Towing Vessel · MISLE 165841 · 13 August 2014 · activity 4954895KAITLYN MARIE Towing Vessel · MISLE 166835 · 13 August 2014 · activity 4954895KITTY Towing Vessel · MISLE 5480 · 21 November 2005 · activity 2538986EMS 355 Tank Barge · MISLE 727287 · 21 November 2005 · activity 2538986

Inspection history · 22

3 February 2022 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7351194
15 July 2020 Administrative Inspection · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7053457
2 May 2016 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5867358
9 October 2015 Industry Initiated Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5742714
13 August 2014 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4954895
24 October 2011 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4174853
6 October 2011 DAPI Audit
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4162611
27 July 2011 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4135249
14 March 2011 Deficiency Check · DAPI Audit · Industry Initiated Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3965365
6 October 2010 Deficiency Check · DAPI Audit
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3878871
18 November 2008 Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3365535
18 November 2007 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3101651
7 May 2007 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2925189
1 February 2006 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2577677
14 January 2006 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2567870
21 November 2005 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2538986
19 February 2002 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1489536
2 April 2001 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 645202
1 February 2000 Type not recorded
No type recorded · CGC POINT MONROE · USCG Heartland District (CGD-H) · Activity 1515871
31 January 2000 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 212888
20 February 1998 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 196066
20 February 1998 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 763739

Deficiency record · 27

04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 3 February 2022 Resolved
The master of a towing vessel must ensure that drills are conducted. The vessel has no record of conducting any emergency drills. Such drills must be witnessed by USCG prior to getting underway. 46 CFR 140.420(a)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 June 2022
Resolution: Coordinated with D8 Towing Vessel Coordinator with recommendation to close outstanding deficiencies. Deficiencies closed, see uploaded "documents" for CG835 deficiencies.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 3 February 2022 Resolved
Closure devices must be provided for deckhouse or hull penetrations, which open to the exterior of the vessel and which may allow water to enter the vessel. Dogs on watertight doors have not been serviced and are difficult to operate. 46 CFR 144.320
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 June 2022
Resolution: Coordinated with D8 Towing Vessel Coordinator with recommendation to close outstanding deficiencies. Deficiencies closed, see uploaded "documents" for CG835 deficiencies.
01 - Certificates & Documentation › 012 - Crew Certificates › Record of employment
Issued 3 February 2022 Resolved
No marine employer shall engage or employ any individual to serve as a crewmember unless the individual passes a chemical test for dangerous drugs for that employer. Owner had no record that the vessel master successfully passed a pre-employment chemical test. 46 CFR 16.210(a)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 June 2022
Resolution: Coordinated with D8 Towing Vessel Coordinator with recommendation to close outstanding deficiencies. Deficiencies closed, see uploaded "documents" for CG835 deficiencies.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 3 February 2022 Resolved
The following list of items must be recorded in the TVR, official logbook, or in accordance with the TSMS applicable to the vessel. The vessel's TVR had none of the required entries in this part. 46 CFR 140.915
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 June 2022
Resolution: Coordinated with D8 Towing Vessel Coordinator with recommendation to close outstanding deficiencies. Deficiencies closed, see uploaded "documents" for CG835 deficiencies.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 3 February 2022 Resolved
Each towing vessel must be equipped with navigation lights, shapes, and sound signals in accordance with the International Regulations for Prevention of Collisions at Sea (COLREGS) or 33 CFR part 84 as appropriate to its area of operation. The vessel had no dayshapes onboard. 46 CFR 140.720
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 June 2022
Resolution: Coordinated with D8 Towing Vessel Coordinator with recommendation to close outstanding deficiencies. Deficiencies closed, see uploaded "documents" for CG835 deficiencies.
10 - Safety of Navigation › N/A - No Subsystem › Echo sounder
Issued 3 February 2022 Resolved
Towing vessels must be equipped with the following equipment, as applicable to the area of operation: Fathometer. Vessel's fathometer was inoperable. Vessel should rectify at next drydock. Vessel restricted to Rivers routes only. 46 CFR 140.725
Action required: 705 - Other - as specified
Resolved 3 June 2022
Resolution: Coordinated with D8 Towing Vessel Coordinator with recommendation to close outstanding deficiencies. Deficiencies closed, see uploaded "documents" for CG835 deficiencies.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 3 February 2022 Resolved
The following vessels must have on board a properly installed, operational Coast Guard type-approved AIS Class A device: A towing vessel of 26 feet or more in length and more than 600 horsepower, engaged in commercial service. 33 CFR 164.46(b)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 June 2022
Resolution: Coordinated with D8 Towing Vessel Coordinator with recommendation to close outstanding deficiencies. Deficiencies closed, see uploaded "documents" for CG835 deficiencies.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 3 February 2022 Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. The electrical connections under the bridge console were inside a junction box that was uncovered. Additionally, rags were found near the connections. 46 CFR 143.400
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 June 2022
Resolution: Coordinated with D8 Towing Vessel Coordinator with recommendation to close outstanding deficiencies. Deficiencies closed, see uploaded "documents" for CG835 deficiencies.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 3 February 2022 Resolved
Towing vessels must be equipped with the following equipment, as applicable to the area of operation: Electronic position-fixing device. The onboard GPS was not functioning properly. 46 CFR 140.725 (c)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 June 2022
Resolution: Coordinated with D8 Towing Vessel Coordinator with recommendation to close outstanding deficiencies. Deficiencies closed, see uploaded "documents" for CG835 deficiencies.
10 - Safety of Navigation › N/A - No Subsystem › Bridge operation
Issued 3 February 2022 Resolved
The emergency duties and duty stations required by this section must be posted at each operating station. The uppermost pilothouse did not have the emergency duties. 46 CFR 140.405 (c)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 June 2022
Resolution: Coordinated with D8 Towing Vessel Coordinator with recommendation to close outstanding deficiencies. Deficiencies closed, see uploaded "documents" for CG835 deficiencies.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 3 February 2022 Resolved
Towing vessels must meet the communications requirements of 33 CFR part 26 and 33 CFR 164.72, as applicable. USCG MI could not verify proper operation of the installed VHF radio. Furthermore, radio did not to have a secondary power source. 46 CFR 140.715(a)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 June 2022
Resolution: Coordinated with D8 Towing Vessel Coordinator with recommendation to close outstanding deficiencies. Deficiencies closed, see uploaded "documents" for CG835 deficiencies.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 3 February 2022 Resolved
The owner and managing operator must ensure that the towing vessel is in compliance with this subchapter and other applicable laws and regulations at all times. The USCG MI discovered significant wastage on the deck of the operating station. Must be rectified to the satisfaction of the attending marine inspector at next dry dock. 46 CFR 137.120(a)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 June 2022
Resolution: Coordinated with D8 Towing Vessel Coordinator with recommendation to close outstanding deficiencies. Deficiencies closed, see uploaded "documents" for CG835 deficiencies.
10 - Safety of Navigation › N/A - No Subsystem › Navigation records
Issued 3 February 2022 Resolved
Each towing vessel must perform the applicable tests in Table 143.245(b) of this section. Vessel had no record of these test being performed. 46 CFR 143.245(b)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 June 2022
Resolution: Coordinated with D8 Towing Vessel Coordinator with recommendation to close outstanding deficiencies. Deficiencies closed, see uploaded "documents" for CG835 deficiencies.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 3 February 2022 Resolved
Emergency lighting must be provided for all internal crew working and living areas. Installed emergency lighting was inoperable.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 June 2022
Resolution: Coordinated with D8 Towing Vessel Coordinator with recommendation to close outstanding deficiencies. Deficiencies closed, see uploaded "documents" for CG835 deficiencies.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 3 February 2022 Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. USCG MI discovered an exhaust leak on the STBD generator. 46 CFR 143.205(a)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 June 2022
Resolution: Coordinated with D8 Towing Vessel Coordinator with recommendation to close outstanding deficiencies. Deficiencies closed, see uploaded "documents" for CG835 deficiencies.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 3 February 2022 Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Vessel crew could not get the port generator to start. 46 CFR 143.205(a)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 June 2022
Resolution: Coordinated with D8 Towing Vessel Coordinator with recommendation to close outstanding deficiencies. Deficiencies closed, see uploaded "documents" for CG835 deficiencies.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 3 February 2022 Resolved
An exposed hazard such as gears and rotating machinery, must be protected by a cover, guard or rail. The starboard generator did not have a guard around the pulley. 46 CFR 144.820
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 June 2022
Resolution: Coordinated with D8 Towing Vessel Coordinator with recommendation to close outstanding deficiencies. Deficiencies closed, see uploaded "documents" for CG835 deficiencies.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 3 February 2022 Resolved
All bilges and void spaces are kept free from accumulation of combustible and flammable materials and liquids insofar as practicable. The bilge contained excessive oil. 46 CFR 142.220(a)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 June 2022
Resolution: Coordinated with D8 Towing Vessel Coordinator with recommendation to close outstanding deficiencies. Deficiencies closed, see uploaded "documents" for CG835 deficiencies.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 3 February 2022 Resolved
The fire main must have a sufficient number of fire hydrants with attached hose to allow a stream of water to reach any part of the machinery space using a single length of fire hose. One fire hose was missing onboard. 46 CFR 142.325 (c)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 June 2022
Resolution: Coordinated with D8 Towing Vessel Coordinator with recommendation to close outstanding deficiencies. Deficiencies closed, see uploaded "documents" for CG835 deficiencies.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 January 2021 Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Vessel has loose wiring on the bridge. Reconnect or remove wiring to the satisfaction of the marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 February 2021
Resolved 8 February 2021
Resolution: Received photo documentation of correction. All sat.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Ship's occupational safety and health policies and programmes
Issued 25 January 2021 Resolved
Each towing vessel must be equipped with an industrial type first aid cabinet or kit, appropriate to the size of the crew and operating conditions. First aid kit onboard was expired. Replace with new kit to the satisfaction of marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 February 2021
Resolved 8 February 2021
Resolution: Received photo documentation of correction. All sat.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 25 January 2021 Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention. The following alarms must be provided: High Bilge Levels. The bilge alarm was not properly activating at the operating station. Repair system to ensure that high bilge alarm in engine room is activated at operating station.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 March 2021
Resolved 8 February 2021
Resolution: Received photo documentation of correction. All sat.
09 - Working and Living Conditions › 092 - Working Conditions › Structural features (ship)
Issued 25 January 2021 Resolved
All vessel equipment must be used in accordance with the manufacturer's recommended practice and in in a manner that minimizes risk of injury or death. This includes, machinery, deck machinery, towing gear, ladders, embarkation devices, cranes, portable tools and safety equipment. Stanchion on lower pilot house deck is broken. Repair stanchion to satisfaction of marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 February 2021
Resolved 8 February 2021
Resolution: Received photo documentation of correction. All sat.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 25 January 2021 Resolved
Extension cords must not be used as a permanent connection to a source of electrical power. Extension cord powering engine room multi outlet plug must be removed.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 February 2021
Resolved 8 February 2021
Resolution: Received photo documentation of correction. All sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 January 2021 Resolved
Connections and terminations must be suitable for the installed conductors, and must retain the original electrical, mechanical, flame retarding, and where necessary, fire resisting properties of the conductor. Tape was used as a connection on port side fixture on second deck. Replace with appropriate connection to satisfaction of marine inspector.
Action required: 10 - Deficiency Rectified
Due 15 February 2021
Resolved 8 February 2021
Resolution: Received photo documentation of correction. All sat.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 25 January 2021 Resolved
Closure devices must be provided for deck house or hull penetrations, which open to the exterior of the vessel and which may allow water to enter the vessel. Dogs on doors of main deck were hard to move and should be serviced to allow use as intended. Reapir to satisfaction of marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 February 2021
Resolved 8 February 2021
Resolution: Received photo documentation of correction. All sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 January 2021 Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Battery on port side of engine room needs to be replaced due to excessive corrosion on terminals. Replacement shall be verified by marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 February 2021
Resolved 8 February 2021
Resolution: Received photo documentation of correction. All sat.

Casualty record · 4

21 November 2005Routine · role: Involved in a Marine Casualty · activity 2538986
14 January 2006Routine · role: Involved in a Marine Casualty · at WAGNER BRIDGE · activity 2567870
27 July 2011Routine · role: Involved in a Marine Casualty · activity 4135249
13 August 2014Major Marine Casualty · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · at FLORIDA AVENUE BRIDGE · activity 4954895
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.