JOHN HENRY

Built
1954
Last inspected
3 July 2025
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 3 July 2025
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2007–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WTU5310
179923
Flag
UNITED STATES
Maury page id
psix-179923

Documentation record

Registered dimensions (L × B × D)65.4 ft × 19.4 ft × 9.6 ft
Registered tonnagegross 66 / net 45
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMISSOURI VALLEY STEEL INC · LEAVENWORTH, KS, UNITED STATES · built 1954
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portGRAND HAVEN, MI
Endorsements, as the file codes themcw_un, rec, reg
DocumentationValid · issued 7 May 2026 · expires 31 May 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it66 - Regulatory (Subpart C or D), Gross Ton
45 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 13 inspections, each with its date, unit and type; 61 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 6 other vessels inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 6

Inspection history · 13

3 July 2025 Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8167772
16 June 2025 Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8160388
10 July 2024 Deficiency Check · Annual Inspection
Physical examination · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 7954249
22 September 2023 Annual Inspection
Physical examination · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 7796591
30 June 2022 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 7491417
7 July 2021 Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 7248242
17 July 2020 COI Inspection
Physical examination · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 7008736
25 April 2018 Uninspected Other
Physical examination · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 6434645
24 May 2013 Industry Initiated Exam
Physical examination · Sector Field Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 4599588
19 November 2012 Type not recorded
No type recorded · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 4493062
13 April 2010 Deficiency Check · Industry Initiated Exam
Physical examination · Sector Field Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 3716267
3 December 2007 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3108530
20 May 2007 Type not recorded
No type recorded · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 2935277

Deficiency record · 61

11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 July 2025 Resolved
Each lifebuoy on a towing vessel must:(1) Be approved under approval series 160.050 or 160.150, Two life rings on the vessel need new SOLAS tape applied IAW 160.050
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2025
Resolved 4 August 2025
Resolution: SOLAS tape installed.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 10 July 2025 Resolved
Each ship subject to subpart T of this part must have on board an officer or member of the crew who holds a marine radio operator permit or higher class license. Towing vessels of >26ft, must have FCC operator onboard.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 August 2025
Resolved 4 August 2025
Resolution: FCC test complete and license is in the mail.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 July 2025 Resolved
Electrical equipment must be marked with is respective current and voltage ratings. The distribution panel in the way of the switchboard is not marked with the current and voltage ratings. Ensure all distribution panels are marked with current and voltage ratings.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2025
Resolved 14 July 2025
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 July 2025 Resolved
Electrical equipment that pose an electrical hazard must be in an enclosure. The switchboard in the engine compartment is not provided with a rear closure to prevent persons or objects from making contact with electrical components inside.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2025
Resolved 28 July 2025
Resolution: Guard installed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 3 July 2025 Resolved
The Master must ensure that all hatches, doors, and other openings designed to be watertight or weathertight function properly. The port light glass in way of the starboard forward watertight door and the port light glass in way of the starboard galley (above the table) are cracked. Make repairs to the same.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2025
Resolved 4 August 2025
Resolution: Port light dead cover added.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 3 July 2025 Resolved
The Master must ensure that all hatches, doors, and other openings designed to be watertight or weathertight function properly. The port light covers throughout the vessel have stuck hinges, painted threads, missing hardware, etc. Service all port covers (i.e. remove paint from threads, properly lube) and ensure proper functionality.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2025
Resolved 14 July 2025
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 July 2025 Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. The following electrical outlets are wired with reverse polarity: a. Port side galley, lower outlet, near the electric stove. b. Mid-ships galley bulkhead (below the donning placard). c. Entrance to the fiddley, port side near watertight door. d. Starboard side pilot house.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2025
Resolved 4 August 2025
Resolution: all outlets repaired.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 3 July 2025 Resolved
Each towing vessel must have a fire-detection system (engine room monitoring system) installed to detect engine room fires. The fire-detection (engine room monitoring) system is non-functional. Make repairs to the system and have the system tested and approved by a qualified servicing company.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 July 2025
04 - Emergency Systems › N/A - No Subsystem › Means of communication between safety centre and other control stations
Issued 3 July 2025 Resolved
Each escape hatch and emergency exit means of escape must be marked on both sides in clearly legible letters at least 2 inches high: “EMERGENCY EXIT, KEEP CLEAR”. The emergency exit from the engine compartment is not properly marked. Mark the same.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2025
Resolved 14 July 2025
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 July 2025 Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. The wooden handles on the switchboard interlock are loose. Repair the same.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2025
Resolved 4 August 2025
Resolution: Handles are secured
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 3 July 2025 Resolved
Paints, coatings, or other flammable or combustible products on board a towing vessel must be stored in a designated storage room or cabinet when not in use. There are flammable/combustibles stored in various locations throughout the vessel. Consolidated flammables and combustibles in to a designated storage room (with no ignition hazards) or remove all flammable and combustibles.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2025
Resolved 14 July 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 July 2025 Resolved
At least two lifebuoys on a towing vessel greater than 26 feet must be fitted with a floating electric waterlight. One of the waterlights was found with batteries that are not the type recommended by the manufacturer. Replace current batteries with batteries approved by the manufacturer.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2025
Resolved 14 July 2025
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 July 2025 Resolved
Electrical connections must be suitably installed to prevent them from coming loose through vibration or accidental contact. The port side controller box in the forward berthing space has a loose cable connector for a cable entering the controller. Replace hardware or connector for cable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2025
Resolved 14 July 2025
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 July 2025 Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. A port side overhead light fixture in the forward berthing space is missing its globe and cage. Replace light fixture globe and cage.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2025
Resolved 14 July 2025
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 July 2025 Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. In the dry storage cage in the forward berthing space, there is a globe and cage light fixture with the lamp out of socket. Replace lamp into socket of light fixture.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2025
Resolved 14 July 2025
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 July 2025 Resolved
Electrical components that pose an electrical hazard must be in an enclosure. In the upper engine room space, an overhead junction box has cable pulled out of its connector and box. Make proper cable connection to the junction box.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2025
Resolved 14 July 2025
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 July 2025 Resolved
Electrical connections must be suitably installed to prevent them from coming loose through vibration or accidental contact. In the upper engine room, there is a free hanging covered junction box no secured. Secure the junction box to the bulkhead or remove it along with its cabling.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2025
Resolved 14 July 2025
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 July 2025 Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. In the port side engine room upper vestibule there are two dead-end cables present of the bulkhead. Remove dead-end cables back to their source.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2025
Resolved 14 July 2025
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 July 2025 Resolved
Electrical conductors passing though watertight bulkheads must be installed so that the bulkhead remains watertight. In the engine room on the forward bulkhead center, there are cable penetrations that need to be make water tight. Fill in penetrations with appropriate watertight and fire-rated material.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2025
Resolved 14 July 2025
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 July 2025 Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. In the engine room of port genset, there is cable pulled out of its stuffing tube on the genset connection box. Repair or replace stuffing tube entry point for proper cable installation.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2025
Resolved 14 July 2025
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 July 2025 Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. In the engine room, there is heat cable installed around the engine shaft stern tube in confliction with tag instructions. Remove installed heating cable or install as per manufacture instructions of used heat cable type.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2025
Resolved 14 July 2025
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 July 2025 Resolved
Electrical equipment must be marked with its respective current and voltage ratings. The main switchboard in the engine room as a power panel located in the center that is not labeled. Label this power panel with its respective current and voltage ratings.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2025
Resolved 14 July 2025
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 July 2025 Resolved
Individual circuit breakers on switchboards and distribution panels must be labeled with a description of the loads they serve. There are three individual circuit breakers on the bottom area of the main switchboard whose labeling is unreadable. Properly label these three circuit breakers with description of their loads served.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2025
Resolved 14 July 2025
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 3 July 2025 Resolved
Each towing vessel must be equipped with at least two portable, battery-powered lights. One must be located in the pilothouse and the other at the access to the engine room. The portable light for the engine room access was not working. Replace access point with a working portable light.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2025
Resolved 14 July 2025
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 3 July 2025 Resolved
An exposed hazard such as gears and rotating machinery, must be protected by a cover, guard or rail. This is not meant to restrict access to towing equipment such as winches, drums, towing gear or steering compartment equipment necessary for the operation of the vessel. In the aft engine room, there are two air compressor system that require guards for their rotating belts exposed. Place suitable designed guards to protect from the rotating belts.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2025
Resolved 28 July 2025
Resolution: Guard Installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 July 2025 Resolved
The master must ensure that all lifesaving equipment is properly maintained and ready for use at all times. There are two lifejackets with expired light devices. Replace the light devices.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2025
Resolved 14 July 2025
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 3 July 2025 Resolved
All vessel equipment must be used in accordance with the manufacturer's recommended practice and in a manner that minimizes risk of injury or death. This includes machinery, deck machinery, towing gear, ladders, embarkation devices, cranes, portable tools, and safety equipment. In the forward berthing space, there is an unmounted/loose fire extinguisher not secured. Secure or remove fire extinguisher from the vessel.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2025
Resolved 14 July 2025
09 - Working and Living Conditions › 092 - Working Conditions › Obstruction/slipping, etc.
Issued 3 July 2025 Resolved
The owner or managing operator must implement procedures to identify and mitigate health and safety hazards, including but not limited to: Slips, trips, and falls. In the upper engine room, there is a 6” x 8” square opening in the deck grating that a boot or foot can get caught in and cause harm or trips. Provide measure to eliminate this opening in the deck grating.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2025
Resolved 28 July 2025
Resolution: Deck grading repaired.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 3 July 2025 Resolved
Each towing vessel must be equipped with an industrial type first aid cabinet or kit, appropriate to the size of the crew and operating conditions. Each towing vessel operating on oceans, coastwise, or Great Lakes routes must have a means to take blood pressure readings, splint broken bones, and apply large bandages for serious wounds. Vessel first aid kit contains expired aspirin. Replace aspirin.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2025
Resolved 14 July 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 July 2025 Resolved
Each lifebuoy with a floating electric water light must have a lanyard of at least 910 millimeters (3 feet) in length, but not more than 1,830 millimeters (6 feet), securing the water light around the body of the lifebuoy. Two lifebuoy waterlight lanyard lengths need to be corrected.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2025
Resolved 14 July 2025
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 3 July 2025 Resolved
Inspection and testing. All portable fire extinguishers, semi-portable fire-extinguishing systems, fire-detection systems, and fixed fire-extinguishing systems, including ventilation, machinery shutdowns, and fixed fire-extinguishing system pressure-operated dampers on board the vessel, must be inspected or tested at least once every 12 months, as prescribed in paragraphs (a)(1) through (8) of this section, or more frequently if otherwise required by the TSMS applicable to the vessel. The engine room natural ventilation closure on the top deck was not able to operate, had missing dogg hardware, and gasket is missing. Restore ventilation closure to proper material condition and function.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2025
Resolved 14 July 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 July 2025 Resolved
Lifebuoys must have the following attachments and fittings: At least one lifebuoy must have a lifeline, secured around the body of the lifebuoy. If more than one lifebuoy is carried, at least one must not have a lifeline attached. Each lifeline on a lifebuoy must: Be buoyant; Be of at least 18.3 meters (60 feet) in length; Be non-kinking; Have a diameter of at least 7.9 millimeters (5/16 inch); Have a breaking strength of at least 5 kilonewtons (1,124 pounds); and Be of a dark color if synthetic, or of a type certified to be resistant to deterioration from ultraviolet light. Two lifebuoys had deteriorated rescue lines. Replace rescue lines.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2025
Resolved 14 July 2025
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 3 July 2025 Resolved
Closure devices must be provided for deckhouse or hull penetrations, which open to the exterior of the vessel and which may allow water to enter the vessel. These devices must be suitable for the expected route. There are multiple window ports throughout vessel with cracked glass and missing dogg hardware for cover plates. Existing hardware is not operational or difficult to open/close/turn due to lack of maintenance. Restore dogged window port hole systems to proper material
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2025
Resolved 14 July 2025
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 10 July 2024 Resolved
Each towing vessel must be equipped with a means to detect smoke in the berthing spaces and lounges that alerts individuals in those spaces. Provide installation of a means to detect smoke in the berthing area.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 July 2024
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 10 July 2024 Resolved
Each pyrotechnic distress signal must be stowed in either: (1) A portable watertight container carried at the operating station. Portable watertight containers for pyrotechnic distress signals must be of a bright color and must be clearly marked in legible contrasting letters at least 12.7 millimeters high with "DISTRESS SIGNALS"; or (2) A pyrotechnic locker secured above the freeboard deck, away from heat, in the vicinity of the operating station.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 July 2024
05 - Radio Communications › N/A - No Subsystem › Distress messages: obligations and procedures
Issued 22 September 2023 Resolved
Missing e-broadcast placard.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 November 2023
Resolved 14 November 2023
Resolution: O/o provided proof of e-broadcast placard being posted
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 September 2023 Resolved
03 types of PFDs. No donning placards.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 November 2023
Resolved 14 November 2023
Resolution: O/o provided proof of donning placards being posted
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 22 September 2023 Resolved
Small quantities of oil and other flammable materials left in E/R following maintenance. Removed from vsl.
Action required: 10 - Deficiency Rectified
Due 14 November 2023
Resolved 22 September 2023
Resolution: Corrected on the spot
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 12 July 2022 Resolved
Each towing vessel must carry at least one (01) Type I lifejacket for each person onboard. 02 Type I lifejackets had been removed from the vessel and the total number did not match the required number listed on the vessel's COI. Rectify by July 22, 2022.
Action required: 705 - Other - as specified
Due 22 July 2022
Resolved 8 August 2022
Resolution: Reviewed evidence of def clearance.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 12 July 2022 Resolved
Each lifejacket must have a lifejacket light securely attached to the front shoulder area. 01 lifejacket light inoperable due to corroded battery. Rectify by July 22, 2022.
Action required: 705 - Other - as specified
Due 22 July 2022
Resolved 8 August 2022
Resolution: Reviewed proof of def clearance.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 July 2021 Resolved
Each life jacket must have a life jacket light securely attached to the front shoulder. Several of the PFD lights were nonfunctional. Ensure all PFD lights operational.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 September 2021
Resolution: Verified PFD lights operational.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 7 July 2021 Resolved
Each immersion suit must be marked in such a way to ID the person or vsl to which it belongs. Immersion suits were not marked. Provide means to ID vsl that immersion suits belong.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 August 2021
Resolution: Reviewed proof of name marked on immersion suits.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 7 July 2021 Resolved
Each immersion suit must be fitted with a life jacket light to the front shoulder. No lights were attached to immersion suits. Provide correct immersion suit attachments.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 August 2021
Resolution: Reviewed proof of lights attached to immersion suits.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 7 July 2021 Resolved
At least 01 ring lifebuoy must be fitted with a floating electric water light. RLB lights were non-functional. Make operational RLB lights.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 September 2021
Resolution: Verified RLB lights operational.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 July 2021 Resolved
Each towing vsl operating on the Great Lakes must have a means to take blood pressure readings and splint broken bones. Provide on-board equipment to provide care as required.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 August 2021
Resolution: Reviewed proof of blood pressure monitoring device and splint onboard.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 7 July 2021 Resolved
Illuminated magnetic compass must be readable from each op station. Light on compass was inoperable. Provide means to illuminate compass.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 September 2021
Resolution: Verified compass light operational.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 July 2021 Resolved
Electrical systems and equipment must minimize fire and shock hazards; electrical hazards must be in an enclosure. Temporary heating strips were plugged into open receptacles. Remove heating strips and provide means to protect from shock hazards.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 September 2021
Resolution: Verified removal of heating strips & extension cords.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 17 July 2020 Resolved
The condition of each towline must be monitored through records of initial min breaking strength and inspected IAW the manufacturer's recommendations. There are no records of maintenance or initial strength. 33 CFR 164.74
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 August 2020
Resolved 14 August 2020
Resolution: Records provided
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 17 July 2020 Resolved
Every towing vessel equipped with an inflatable survival craft must have approved placards or other posted instructions for launching and inflating inflatable survival craft. Posted placard was not for the LR onboard the vsl. 46 CFR 141.320
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 August 2020
Resolved 14 August 2020
Resolution: Proper placard posted
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 17 July 2020 Resolved
When the towing vessel is underway, the EPIRB must be stowed in its float-free bracket with the controls set for automatic activation and be mounted in a manner so that it will float free if the towing vessel sinks. The hydrostatic release is expired. 46 CFR 141.380(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 August 2020
Resolved 14 August 2020
Resolution: New Hydrostatic release
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 July 2020 Resolved
Each towing vessel must carry at least one appropriately-sized lifejacket for each person on board. Vsl has 05 PFDs onboard. Vsl max POB is 06. 46 CFR 141.340(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 August 2020
Resolved 14 August 2020
Resolution: New life jacket provided
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 July 2020 Resolved
Each lifejacket must be marked with the name of the vessel and have the following attachments and fittings: approved light and whistle. Not all PFDs were properly marked and/or did not have all the appropriate attachments. 46 CRR 141.340(f)/(g)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 August 2020
Resolved 14 August 2020
Resolution: New lights and whisile provided
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 17 July 2020 Resolved
Each towing vessel must carry at least one appropriate-size immersion suit for each person onboard. 05 immersion suits onboard. 06 max POB. 46 CFR 141.350
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 August 2020
Resolved 14 August 2020
Resolution: New immersion Provided
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 17 July 2020 Resolved
A fixed fire pump must be capable of being energized remotely from a safe place outside the engine room and at the pump. The remote start was not functioning. 46 CFR 142.325(a)(2)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 August 2020
Resolved 14 August 2020
Resolution: New portable self priming fire pump purchased and onboard vessel
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 17 July 2020 Resolved
The fire main must have a sufficient number of fire hydrants with attached hose to allow a stream of water to reach any part of the machinery space using a single length of fire hose. The fire hose attached to the hydrant had multiple holes. 46 CFR 142.325(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 August 2020
Resolved 14 August 2020
Resolution: New 1.5 fire hose and nozzle with portable fire pump
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 17 July 2020 Resolved
A fixed fire pump must be capable of delivering water at a pitot-tube pressure of at least 50 psi. No pressure gauge on fire pump; unable to verify psi. 46 CFR 142.325
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 August 2020
Resolved 14 August 2020
Resolution: Fire pump provided adequate pressure
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 17 July 2020 Resolved
Pressure vessels over 5 cubic feet in volume and over 15 pounds per square inch MAWP must be equipped with an indicating pressure gauge (in a readily visible location) and with one or more spring-loaded relief valves. 02 pressure vessels do not have relief valves. 46 CFR 143.300(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 August 2020
Resolved 14 August 2020
Resolution: New relief valves installed
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 17 July 2020 Resolved
Each towing vessel must be equipped with at least two portable, battery-powered lights. One must be located in the pilothouse and the other at the access to the engine room. No flashlights were in these locations. 46 CFR 143.410(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 August 2020
Resolved 14 August 2020
Resolution: New portable light provided
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 17 July 2020 Resolved
Each remote valve control for fuel shutoff must be marked in clearly legible letters, at least 25 millimeters (1 inch) high, indicating the purpose of the valve and the way to operate it. Mislabeled as "pull" instead of proper operating procedures. 46 CFR 143.260(e)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 August 2020
Resolved 14 August 2020
Resolution: Remote valves properly marked
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 17 July 2020 Resolved
A vessel of 20 m or more in length shall be provided with a bell in addition to a whistle. No bell onboard 33 CFR 83.33(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 August 2020
Resolved 14 August 2020
Resolution: Proper bell purchased
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 17 July 2020 Resolved
E/R alarms required at each operating station must provide notification when an emergency condition exists. The alarm panel was not functioning. 46 CFR 143.230
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 August 2020
Resolved 3 September 2020
Resolution: Old panel had to be replaced,New panel was installed.