Records from 1990 to 2026. Most recent: inspection, 8 June 2026.
Documentation record
Registered dimensions (L × B × D)80.4 ft × 24.0 ft × 11.3 ft
Registered tonnagegross 146 / net 99
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderNOLTY THERIOT, BUILDER · GOLDEN MEADOW · built 1961
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portHOLLAND, MI
Trade endorsementsCoastwise, unrestricted, Recreational, Registry
DocumentationValid · issued 16 May 2026 · expires 31 May 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it99 - Regulatory (Subpart C or D), Net Ton
146 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 31
8 June 2026
Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8390043
7 October 2025
Annual Inspection
Physical examination · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 8244716
23 August 2024
Bulk Liquid Transfer Monitor
Physical examination · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 7989251
17 July 2024
Deficiency Check · Annual Inspection
Physical examination · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 7960245
21 July 2023
Deficiency Check · Annual Inspection
Physical examination · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 7751636
30 June 2022
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 7491483
11 May 2021
COI Inspection · Initial Certification · Deficiency Check
Physical examination · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 7240172
20 May 2016
Industry Initiated Exam
Physical examination · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 5949345
4 December 2015
Type not recorded
No type recorded · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 5778354
27 March 2014
Type not recorded
No type recorded · Sector Field Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 4824291
31 May 2013
Type not recorded
No type recorded · Sector Field Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 4607041
19 November 2012
Type not recorded
No type recorded · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 4493062
3 July 2012
Deficiency Check
Physical examination · Sector Field Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 4383661
24 May 2012
Industry Initiated Exam
Physical examination · Sector Field Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 4320338
30 November 2011
Administration
Administrative · Sector Field Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 4274327
12 April 2010
Industry Initiated Exam · Deficiency Check
Physical examination · Sector Field Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 3714703
13 December 2006
Administrative Inspection
Administrative · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 2847763
31 May 2006
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2666284
27 September 2005
Deficiency Check
Physical examination · Marine Safety Detachment Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 2502380
23 August 2005
Uninspected Other
Physical examination · Marine Safety Detachment Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 2473044
2 February 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1999968
6 August 1999
Type not recorded
No type recorded · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 101301
9 July 1999
Type not recorded
No type recorded · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 16470
8 October 1997
Type not recorded
No type recorded · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 107293
8 October 1997
Deficiency Check
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1443922
17 July 1997
Type not recorded
No type recorded · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 654998
23 May 1997
Uninspected Towing Vessel
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1445236
22 May 1997
Type not recorded
No type recorded · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 154943
22 May 1997
Type not recorded
No type recorded · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 217884
12 September 1991
Type not recorded
No type recorded · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 654994
12 June 1990
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 448498
10 - Safety of Navigation › N/A - No Subsystem › Record of drills and steering gear tests
Issued 17 July 2024
Resolved
the TVR, official logbook, or in accordance with the TSMS applicable to the vessel. The record must include:(1) The date of the drill and instruction;(2) A description of the drill scenario and instruction topics;(3) The personnel involved. Crew stated they recently conducted all required drills. Provide evidence of logged drills.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 July 2024
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 17 July 2024
Resolved
The operator of each self-propelled vessel 12 meters or more in length shall carry, on board and maintain for ready reference, a copy of the Navigation Rules. Provide a copy of the required Navigation Rules.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 July 2024
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 21 July 2023
Resolved
All PFE must be inspected / serviced at least once every 12 months. Some PFE onboard were missed during annual servicing. Provide proof of inspection.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 July 2023
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 21 July 2023
Resolved
A 40 B:C PFE must be located near the storage cabinet of flammable / combustible products. The PFE was laying on top of the storage cabinet inside its bracket. Properly mount 40 B:C PFE near flammable / combustible storage cabinet.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 August 2023
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 21 July 2023
Resolved
Radio Log Books must keep required information and be readily available for 2 years. No current radio log book entries. Information was found in TVR; discussed with O/O and radio log book will be also be maintained as required by 47 CFR 80.409.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 21 July 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 July 2023
Resolved
Work vests must be stored separately in a location marked "WORK VESTS" so that they are not substituted for Type I PFDs. Work vests found in crew cabins with Type I PFDs. O/O moved to proper storage location.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 21 July 2023
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 12 July 2022
Resolved
Rails or equivalent protection must be installed near the periphery of all decks accessible to crew. Aft STBD ladder missing safety chain. Rectify by July 22, 2022.
Action required: 705 - Other - as specified
Due 22 July 2022
Resolved 29 July 2022
Resolution: Received proof of correction.
08 - Alarms › N/A - No Subsystem › Steering gear alarm
Issued 10 August 2021
Resolved
Machinery and electrical systems must be maintained to provide for safe operation of the towing vessel. The low hydraulic steering fluid level alarm was alerting for unknown reasons. Discover root cause of alert and ensure proper repair.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 September 2021
Resolution: Verified alarms operational.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 10 August 2021
Resolved
Machinery and electrical systems must be maintained to provide for safe operation of the towing vessel. The low lubricating oil pressure alarm for mde was alerting for unknown reasons. Discover root cause of alert and ensure proper repair.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 September 2021
Resolution: Verified alarms operational.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 23 August 2005
Resolved
No EAP information available on the vessel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 September 2005
Resolved 27 September 2005
Resolution: Provided proof of EAP documentation.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 23 August 2005
Resolved
Lifebuoy did not have name of vessel or retro-reflective tape on it.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 September 2005
Resolved 27 September 2005
Resolution: Provided life ring with vessel name and retro-reflective tape on it.
Lifesaving › Lifejacket/PFD (Type III) › Marking
Issued 23 August 2005
Resolved
PFD's are not labeled with vessel name.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 September 2005
Resolved 27 September 2005
Resolution: Provided PFD''s with vessel name on them.
Fire Fighting › Semiportable Chemical-Foam Fire Extinguishers › Condition
Issued 23 August 2005
Resolved
Semi portable fire extinguisher is not installed.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 September 2005
Resolved 27 September 2005
Resolution: Provided semi portable fire extinguishers for engine room.
Communications › Alarms/Indicators › General Alarm
Issued 23 August 2005
Resolved
demonstrate that general alarm works properly
Action required: 705 - Other - as specified
Due 23 September 2005
Resolved 27 September 2005
Resolution: Demonstrated General Alarm works.