MAURY USCG vessel records Sign in
← All vessels

LAURA GAIL

LAURA GAIL is a 1972 towing vessel. The Coast Guard has recorded 7 inspections since 2004, most recently in October 2013, along with 16 deficiencies — 1 with no resolution recorded — and 1 casualty investigation in 2006.

Records from 2004 to 2013. Most recent: inspection, 25 October 2013.

Built
1972
Last inspected
25 October 2013
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8991671 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDA3468
Flag
UNITED STATES
368068390
Maury page id
psix-18131

Inspections, by type

…with no type recorded5
…past their stated due date1
Years with a record 5 calendar years (2004–2013)
The 7 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 13 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it198 - Regulatory (Subpart C or D), Gross Ton
235 - Convention (Subpart B), Gross Ton
134 - Regulatory (Subpart C or D), Net Ton
70 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDK5797MMSI 368068390 · active · compulsorily equipped · granted 1 December 2018, expires 1 December 2028
WDA3468MMSI 366798810 · cancelled · voluntarily equipped · granted 26 January 2011, cancelled 13 November 2018
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 4

Inspection history · 7

25 October 2013 Type not recorded
No type recorded · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 4794129
23 February 2012 Administration
Administrative · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 4252073
2 December 2006 Type not recorded
No type recorded · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 2871279
22 September 2005 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2498839
2 December 2004 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2252659
30 November 2004 Uninspected Other
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2252998
28 November 2004 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2254136

Deficiency record · 16

Fire Fighting › Fire Hoses › Condition
Issued 22 April 2005 Resolved
Prior to issuance of UTV sticker for satisfactory voluntary exam, new 2 holed fire hoses with new 50 ft., lined commercial grade hoses with a minimum diameter of 1 1/2 inches. The compliance date coincides with the effective date of 46 CFR 27.301.
Action required: 705 - Other - as specified
Due 29 April 2005
Resolved 11 May 2005
Resolution: [name withheld] attended vessel and examined 4 new, 50 ft 1 1/2" lined, commercial fire hoses. All sat.
Construction/Loadline › Structures › Superstructure
Issued 30 November 2004 Resolved
Provide classification society (ABS) attestation of satisfactory completion of permanent repairs to fractured flange portion of stbd midships bulwarks. Until cleared, vessel may not operate outside the Boundary Line as defined in 46 CFR Part 7.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 December 2004
Resolved 22 April 2005
Resolution: Examined and found satisfactory repair.
Construction/Loadline › Hull › Stiffener
Issued 30 November 2004 Resolved
Provide classification society (ABS) attestation of satisfactory completion of permanent repairs to 4 buckled transon stiffeners in steering gear compartment. Until cleared, vessel may not operate outside of the Boundary Line as defined in 46 CFR Part 7.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 December 2004
Resolved 22 April 2005
Resolution: ABS Surveyor examined and found satisfactory repair
Construction/Loadline › Hull › Longitudinal Frame
Issued 30 November 2004 Resolved
Provide classification society (ABS) attestation of satisfactory completion of permanent repairs to buckled longitudinal centerline frame in steering gear compartment IWO rudder post. Until cleared, vessel may not operate outside the Boundary Line as defined in 46 CFR Part 7.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 December 2004
Resolved 22 April 2005
Resolution: ABS Surveyor examined and found satisfactory repair.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 30 November 2004 No resolution recorded
Prior to completion of next dry dock exam, provide class (ABS) attestation of satisfactory completion of permanent repairs to buckled portion of longitudinal bulkhead separating the steering compartment and port ballast tank IWO bilge/transom . Temporary repairs completed to the satisfaction of ABS Surveyor 22Apr2005.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 November 2005 — due date passed with no resolution recorded
Construction/Loadline › Structures › Air Pipe
Issued 30 November 2004 Resolved
Renew/repair missing and broken vent closure devices on gooseneck vents.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 December 2004
Resolved 22 April 2005
Resolution: Examined and found satisfactory.
Communications › Alarms/Indicators › Bilge Alarm
Issued 30 November 2004 Resolved
Prove proper operation of all installed bilge high water alarms and heat sensors
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 December 2004
Resolved 22 April 2005
Resolution: Cleared item due to not required. Owner intends on installing another type of bilge alarm at a future date.
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 30 November 2004 Resolved
Properly display name and hailing port on stern. These markings appear to be obscured by running rust.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 December 2004
Resolved 22 April 2005
Resolution: Examined satisfactory name/hailing port.
Construction/Loadline › Structures › Manhole
Issued 30 November 2004 Resolved
Provide classification society (ABS) attestation of satisfactory installation of replacement for missing dog on rope locker raised hatch. Until cleared, vessel may not operate outside the Boundary Line as defined in 46 CFR Part 7.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 December 2004
Resolved 22 April 2005
Resolution: Examined and found satisfactory replacement dog.
Engineering › Compressed Air System (control) › Valve
Issued 30 November 2004 Resolved
Install and make available for testing properly-sized safety relief valves on air receivers.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 December 2004
Resolved 22 April 2005
Resolution: Examined newly installed safety relief valves.
Documentation › Certificates/Documents › International Load Line Certificate
Issued 30 November 2004 Resolved
Provide evidence of satisfactory completion of annual ABS survey for continued validity of Load Line Certificate. Until cleared, vessel may not operate outside the Boundary Line as defined in 46 CFR Part 7.
Action required: 705 - Other - as specified
Due 30 December 2004
Resolved 22 April 2005
Resolution: ABS Surveyor endorsed Loasd Line certificate this date.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 30 November 2004 Resolved
Provide documentation of satisfactory completion of hydrostatic testing and annual maintenance for engine room fixed CO2 extinguishing system.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 December 2004
Resolved 6 January 2005
Resolution: Received satisfactory documentation of completion of required testing and maintenance.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 30 November 2004 Resolved
Provide documentation of satisfactory completion of hydrostatic testing and annual maintenance for engine room semi-portable CO2 extinguishing system and provide documentation of satisfactory annaul servicing for all other portable extinguishers on board.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 December 2004
Resolved 6 January 2005
Resolution: Received satisafctory documentation of completion of required testing and inspections.
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 30 November 2004 Resolved
Renew expired hydrostatic release unit for liferaft.
Action required: 17 - Rectify deficiencies prior to departure
Due 3 December 2004
Resolved 1 December 2004
Resolution: Renewed hydrostatic release unit on board.
Communications › Radio Communications › EPIRB
Issued 30 November 2004 Resolved
Renew expired hydrostatic release unit for EPIRB.
Action required: 17 - Rectify deficiencies prior to departure
Due 3 December 2004
Resolved 1 December 2004
Resolution: Renewed hydrostatic release unit on board.
Deck/Cargo › Towing › Towline
Issued 30 November 2004 Resolved
Renew parted 10" towing hawser.
Action required: 705 - Other - as specified
Due 30 December 2004
Resolved 6 January 2005
Resolution: Received fax copy of invoice for new hawser with documentation of breaking strength.

Casualty record · 1

2 December 2006Routine · role: Involved in a Marine Casualty · activity 2871279
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

SEGUIN (2006). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.