Inspection history · 41
12 April 2026
PSC B
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 8346400
19 August 2025
Deficiency Check · PSC B
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8207998
21 July 2025
MARPOL Annex I Examination · PSC B
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8186289
30 October 2024
PSC B
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8026859
28 October 2024
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8025958
28 August 2024
In-Service Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7990868
10 July 2024
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7955235
10 July 2024
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7955455
9 July 2024
PSC B
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7953679
28 June 2024
PSC A
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7938744
18 December 2023
Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7840093
15 December 2023
PSC A
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7836607
4 December 2023
Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7833358
27 November 2023
Appeal · ISM Exam · PSC B
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7828944
20 October 2023
PSC B · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7807320
12 October 2023
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7811778
10 October 2023
Deficiency Check · PSC B
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7802692
25 May 2023
Deficiency Check · PSC B
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7696108
9 April 2021
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7171766
18 March 2021
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7158699
11 January 2021
In-Service Inspection · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7125315
4 May 2020
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6948026
13 February 2020
PSC A
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6906375
13 February 2020
In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6908907
13 February 2020
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6914287
3 July 2019
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6734890
25 June 2019
ISPS II Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6716610
26 April 2019
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6665228
23 October 2018
Deficiency Check · Administrative Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6566381
18 October 2018
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6562275
19 April 2018
Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6394850
29 March 2018
Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6381035
19 March 2018
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6370061
13 December 2017
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6323777
11 October 2017
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6285832
18 March 2017
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6106974
5 September 2016
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 5989312
27 August 2016
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5984558
19 April 2016
Deficiency Check
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 5858268
18 April 2016
Administrative Inspection
Administrative · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 5856979
18 April 2016
Type not recorded
No type recorded · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 5857090
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company responsibility and authority
Issued 21 July 2025
Resolved
THE COMPANY AND THE SHIP SHALL COMPLY WITH THE REQUIREMENTS
OF THE INTERNATIONAL SAFETY MANAGEMENT CODE. THE COMPANY
SHOULD ESTABLISH PROCEDURES TO ENSURE THAT THE SHIP IS
MAINTAINED IN ACCORDANCE WITH THE PROVISIONS OF THE RELEVANT
RULES AND REGULATIONS ESTABLISHED BY THE COMPANY. THE
TECHNICAL AND/OR OPERATIONAL NATURE OF DEFICIENCES 02, 03, 04, 05, 06, AND 07 PROVIDE OBJECTIVE EVIDENCE OF A SERIOUS FAILURE, OR LACK OF EFFECTIVENESS, OF THE IMPLEMENTATION OF THE ISM CODE. AN EXTERNAL AUDIT REPORT SATISFACTORY TO THE OCMI MUST BE SUBMITTED PRIOR TO THE CLEARANCE OF THIS DEFICIENCY.
74SOLAS (2020) IV/3.1 ISM CODE 10.13 ABC
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 August 2025
Resolved 19 August 2025
Resolution: EXTERNAL AUDIT UNABLE TO BE COMPLETED PRIOR TO DEPARTURE. COTP CHANGED CODE 30ABC TO CODE 50ABC
External ISM audit completed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 21 July 2025
Resolved
EVERY TOTALLY ENCLOSED LIFEBOAT SHALL BE PROVIDED WITH A RIGID WATERTIGHT ENCLOSURE WHICH COMPLETELY ENCLOSES THE
LIFEBOAT. PSCO OBSERVED THE KNIFE EDGE OF THE STERN LIFEBOAT
HATCH HAD 02 NOTCHES CUT OUT THAT COMPROMISE THE LIFEBOATS
WATERTIGHT INTEGRITY.
SOLAS 1997 III/44.2 30ABC
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 23 July 2025
Resolution: RECEIVED REPORT THAT VESSEL HAD MADE TEMPORARY REPAIRS. INSPECTORS VISUALLY VERIFIED THAT REPAIRS WERE MADE. CLASS REPORT ATTESTED TO SATISFACTORY TEMP REPAIRS AND USED WATER HOSE TO VERIFY WATGERTIGHT INTEGRITY.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 21 July 2025
Resolved
WATERTIGHT TUNNELS SHALL BE OF THE SAME STRENGTH AS WATERTIGHT BULKHEADS AT THE CORRESPONDING LEVELS. THE MEANS
USED FOR MAKING THEM WATERTIGHT, AND THE ARRANGEMENTS ADOPTED FOR CLOSING OPENINGS IN THEM, SHALL BE TO THE SATISFACTION OF THE ADMINISTRATION. PSCO OBSERVED WATERTIGHT SLIDING DOOR BETWEEN THE ENGINE ROOM AND CARGO TUNNEL WITH GAPS LARGE ENOUGH FOR LIGHT TO BE SEEN THROUGH WHEN FULLY CLOSED.
SOLAS 2004 II-1/19.1 30ABC
GAPS LARGE ENOUGH FOR LIGHT TO BE SEEN THROUGH WHEN FULLY
CLOSED.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 23 July 2025
Resolution: RECEIVED REPORT THAT VESSEL HAD MADE TEMPORARY REPAIRS. INSPECTORS VISUALLY VERIFIED THAT REPAIRS WERE MADE. CLASS REPORT ATTESTED TO SATISFACTORY TEMP REPAIRS AND USED WATER HOSE TO VERIFY WATGERTIGHT INTEGRITY.
14 - Pollution Prevention › 141 - MARPOL Annex I › Retention of oil on board
Issued 21 July 2025
Resolved
THE OIL RESIDUES WHICH CANNOT BE DISCHARGED INTO THE SEA IN
COMPLIANCE WITH THE REGULATION SHALL BE RETAINED ON BOARD FOR
SUBSEQUENT DISCHARGE TO RECEPTION FACILITIES. ANY DISCHARGE
INTO THE SEA OF OIL OR OILY MIXTURES SHALL BE PROHIBITED EXCEPT WHEN THE OILY MIXTURE IS PROCESSED THROUGH AN OIL FILTERING EQUIPMENT MEETING THE REQUIREMENTS OF REGULATION 14.7 OF THIS ANNEX. PSCO OBSERVED SIGNIFICANT AMOUNT OF WATER IN THE CARGO TUNNEL MIXED WITH HYDRAULIC FLUID OIL AND COAL DUST RESIDUE CREATING AN OILY WATER MIX. WHEN [name withheld] HOW THE CARGO TUNNEL IS DE-WATERED, THE CREW EXPLAINED IT WAS COMPLETED BY PUMPING THE WATER MIX INTO TANK TST #7 PORT THEN DISCHARGED OVERBOARD ONCE OFFSHORE.
MARPOL I/15.3.2 & 15.9 30ABC
Condition: Placed in Improper Service
Action required: 30 - Ship detained
Resolved 23 July 2025
Resolution: RECEIVED PICTURES FROM VESSEL AND CLASS SURVEY STATING THAT THE CARGO TUNNEL WAS CLEAR OF WATER AND THAT THE TANKS HAD BEEN PUMPED OUT TO SHORE AND THE TANK IS OKAY. ALSO RECEIVED RECEIPT OF OFFLOAD OF 4,000 GALLONS OF OILY WATER TO SHORE.
09 - Working and Living Conditions › 091 - Living Conditions › Access/structure
Issued 21 July 2025
Resolved
THE PROVISION OF SAFE MEANS OF ACCESS TO AND THROUGHOUT THE
SHIP, AND THE SATISFACTORY PHYSICAL CONDITIONS OF LADDERS, DECKS, BULWARKS. FENCING, HANDRAILS. ETC. PSCO OBSERVED 07 STEPS THROUGHOUT THE CARGO TUNNEL THAT WERE DETERIORATED, RUSTED THROUGH, OR COMPLETED WASTED.
ILO 147 PREVENTION OF OCCUPATIONAL ACCIDENTS/STRUCTURAL FEATURES OF THE SHIP/PARAGRAPH 1 //and// PWSA 46 USC 70002 & 33 USC 1223(B) 17BC
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 July 2025
Resolution: RECEIVED CLASS REPORT STATING THAT WASTED/DETERIORATED STEPS THROUGHOUT THE CARGO TUNNEL HAVE BEEN REMOVED, TO BE PERMANANTLY REPLACED NO LATER THAN THE DUE DATE OF THE NEXT DRY-DOCKING SURVEY.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 21 July 2025
Resolved
THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO ENSURE THE SHIP IN ALL MEANS,"AND SHALL REMAIN FIT TO PROCEDE TO SEA WITHOUT DANGER TO SHIP OR PERSONS ONBOARD. PSCO
OBSERVED MULTIPLE HYDRAULIC PIPE CONNECTIONS, HOSES, AND FITTINGS LEAKING AND ACCUMULATIONS ON THE DECK THROUGHOUT THE CARGO TUNNEL
74 SOLAS (2020) I/11A 17BC
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 July 2025
Resolution: RECEIVED CLASS REPORT STATING THAT ALL HOSES OVERHAULED AND ANY OIL ACCUMULATION ON THE DECK THROUGHOUT THE CARGO TUNNEL HAS BEEN CLEANED.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 21 July 2025
Resolved
ALL ELECTRICAL APPARATUS SHALL BE SO CONSTRUCTED AND SO
INSTALLED AS NOT TO CAUSE INJURY WHEN HANDLED OR TOUCHED IN THE NORMAL MANNER. PSCO OBSERVED WATER INTRUSION FROM THE
JACKET WATER COOLING OF GENERATOR INGRESSING INTO AN
ELECTRICAL JUNCTION BOX.
SOLAS (2004) II-1/45.1.3 17BC
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 July 2025
Resolution: RECEIVED CLASS REPORT STATING THAT THE DAMAGED JACKET WATER COOLING INNER PIPE OF GENERATOR #4 HAS BEEN REPLACED WITH A NEW ONE AND FOUND IN GOOD WORKING CONDITION.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 21 July 2025
Resolved
“A’ CLASS DIVISIONS ARE THOSE DIVISIONS FORMED BY BULKHEADS AND DECKS WHICH COMPLY WITH...THE CAPABILITY OF PREVENTING THE PASSAGE OF SMOKE AND FLAME TO THE END OF THE ONE HOUR
STANDARD FIRE TEST. PSCO OBSERVED MULTIPLE DRILLED HOLES
THROUGH THE DOOR ELIMINATING THE INTEGRITY OF THE BOUNDARY.
SOLAS (1997) II-2/3.3 17BC
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 July 2025
Resolution: RECEIVED CLASS REPORT CLASS "A" FIRE DOOR FOR THE ENGINE CONTROL ROOM HAS BEEN TEMPORARILY REPAIRED, TO BE PERMANENTLY REPLACED BY THE DUE DATE OF NEXT DRY-DOCKING SURVEY.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 October 2024
Resolved
THE SAFETY OF PASSENGERS, CREW AND SHIP FROM ELECTRICAL HAZARDS WILL BE ENSURED. PSCO OBSERVED GROUND ON 220V DISTROBUTION PANEL IN THE ENGINE CONTROL ROOM.
74 SOLAS(04) II-1/40.1.3
10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 30 October 2024
Resolved 30 October 2024
Resolution: CREW WAS ABLE TO LOCATE AND FIX THE FAULT DUE TO AN EXTENSION CORD PLACED INTO IMPROPER SERVICE FOR A FAN IN THE STEERING GEAR ROOM.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 28 June 2024
Resolved
04114 - Emergency Systems - Started Automatically upon failure of the main source of electrical power supply, a second source independent means of starting the emergency generator is provided. PSCO observed batteries for emergency generator depleted and unable to start generator.
74 SOLAS (97). II-1, Reg: 43.3.1.2.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 28 June 2024
Resolved 29 June 2024
Resolution: Received Class report attesting to the replacement and successful operation of two new batteries to operate the EDG.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead strength
Issued 28 June 2024
Resolved
02129 - Structural Conditions - Each watertight subdivision bulkhead shall be constructed in such a manner that it shall be capable of supporting the pressure due to the maximum head of water. PSCO observed 7 bulkheads in Cargo Tunnel with wires running through tubes without packing to ensure watertight integrity.
74 SOLAS (97). II-1, Reg: 14.1.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 28 June 2024
Resolved 28 June 2024
Resolution: Vessel completed proper packing of all watertight bulkhead openings prior to [name withheld].
12 - Dangerous Goods › N/A - No Subsystem › Fire protection cargo deck area
Issued 28 June 2024
Resolved
12107 - Dangerous Goods - Where cables which are installed in hazardous areas introduce the risk of fire or explosion in the event of an electrical fault in such areas, special precautions against such risk shall be taken to the satisfaction of the administration. PSCO observed 7 light fixtures in the cargo tunnel with exposed wiring, insufficient packing glands, or open electrical boxes.
74 SOLAS (97). II-1, Reg: 45.5.4.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 28 June 2024
Resolved 28 June 2024
Resolution: Vessel completed correction of electrical components prior to [name withheld].
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 15 December 2023
Resolved
04110 - Abandon ship drills - Each abandon ship drill shall include reporting to stations and preparing for the duties described in the muster list. PSCO observed crew members report without billeted items and unfamiliar with muster list.
74 SOLAS 20 III/19.3.4.1. 17.c
Action required: 17 - Rectify deficiencies prior to departure
Due 15 December 2023
Resolved 15 December 2023
Resolution: PSCO required crew to undergo training regarding abandoned ship duties and responsibilities. After training, observed satisfactory abandoned ship drill by vessel's crew.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 15 December 2023
Resolved
11131 - On board training and instructions - The training manual shall contain instructions and information on the life saving appliances in the ship. PSCO observed Life Jacket and Ring Buoy lights of different manufacturer type without operating procedures in the ship's training manual. 74 SOLAS 20 III/35.3. 10.c
Action required: 10 - Deficiency Rectified
Due 15 December 2023
Resolved 15 December 2023
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boat inventory
Issued 15 December 2023
Resolved
11105 - Rescue boat inventory - All items of rescue boat equipment, with the exception of boat hooks, shall be secured within the rescue boat by lashings, storage in lockers or compartments. PSCO observed rescue boat not contain buoyant oars. LSA Code 5.1.2. 10.c
Action required: 10 - Deficiency Rectified
Due 15 December 2023
Resolved 15 December 2023
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 28 November 2023
Resolved
15109
The company should establish proceedures to ensure that the ship is maintained in accordance with the provisions of the relevant rules and regulations established by the company. The technical and/or operational nature of the deficiencies noted below provide objective evidence of a serious failure of the implementation of the ISM Code. An external audit report satisfactory to the OCMI must be submitted prior to clearance of this deficiency.
74SOLAS(20)IV/3.1
ISM Code 10.1
30ac
Action required: 30 - Ship detained
Due 28 November 2023
Resolved 30 November 2023
Resolution: Submitted satisfactory class report from LR attesting to SMS deficiencies and plan to rectify other communication and reporting issues.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 28 November 2023
Resolved
09233
In a ship in which fuel oil is used, the arrangement for the
storage, distribution and utilization of the oil shall ensure
the safety of the ship. PSCO observed an oil leak from a high—pressure fuel line and lube oil line, both attached to the main engine, at a rate of 2—3 drops a minute. These conditions allowed for the introduction of flammable oils into the engine room, creating a hazardous condition.
74SOLAS(97 cons) II-2/15.2
17ac
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 28 November 2023
Resolved 29 November 2023
Resolution: After completion of repair, there are no leakage from high pressure
fuel line and waste oil line.-NKK Class report.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 28 November 2023
Resolved
09233
Satisfactory means (in the form of guard rails...) shall be
provided for the protection of the crew in getting to and from the machinery space. A guard rail on the starboard side of the engine in the tween deck was missing, creating a hazard whereby personnel could fall 15 to 20 feet.
ICLL(66)REG 25(4)
17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 28 November 2023
Resolved 29 November 2023
Resolution: Crew members placed pipe by welding for rail in machinery space on tween deck and found out in good condition. - NKK Class report.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 28 November 2023
Resolved
02107
Following installation, the master, owner, operator, agent, or person in charge of the vessel subject to this subpart must properly maintain the BWMS in accordance with manufacturer specifications. There is a leak of approximately 6—10 gallons per day of treated ballast streaming in from a clean water ballast tank valve causing water to enter the engine room.
33CFR151.2025(a)(1)
17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 28 November 2023
Resolved 16 December 2023
Resolution: NKK Class report has extended the repairs to be conducted prior to 12/27/2023.
18DEC23: vessel submitted class report clearing def, additionally vessel was issued new full term Ballast certificate.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 27 November 2023
Resolved
07126
The condition of the ship and its equipment should be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to persons on board. Holding devices were found to be in place pressing down on the pressure valves for sight glasses on the lube oil tank and HFO settling tank. The use of these devices creates a risk for large amounts of oil to spill into engine room spaces and a potential hazard to the ship and its crew.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 28 November 2023
Resolved 29 November 2023
Resolution: Crew members removed holding devices on pressure valves to the sight glass on the Main Engine Low sulfur Cylinder oil tank as well as Main Engine Lub oil storage tank. -NKK Class report.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 20 October 2023
Resolved
15109-In meeting these requirements, the company should ensure that: inspections are held at appropriate intervals; appropriate corrective action is taken; and records of these activities are maintained. PSCO observed two crew cabins and several locations thought accommodation spaces with excessive and disorganized items stored preventing safe access to the space and showing that good house keeping practices are not being followed as required by the company. The remarks on the deck and accommodation inspections and the crew quarter inspections do not reflect the conditions of the vessel at the time of the exam. Additionally, the monthly deck maintenance inspections are not being conducted as required by company procedures and the remarks on the weekly inspections for the pilot ladders and embarkation ladder do not reflect the condition of the fwd embarkation ladder as stated in deficiency #3. Furthermore, The liferaft testing log form for the 2022 inspection is not properly filled out and the crew has not conducted the 2023 liferaft inspections. Due to the objective evidence in the above deficiency and as stated in deficiencies 2,3,4,5,6 and 7 the vessel is not in substantial compliance with the relevant conventions. The Captain of the Port questions the adequacy and overall implementation of the vessel's SMS under the ISM Code. An external audit conducted by Flag or RO is required to determine whether the ship is operating in accordance with the ISM Code. Provide a copy of the completed audit report to the Coast Guard prior to departure from port.
74SOLAS(20)IX/3.1
ISM Code 10.2
Action required: 30 - Ship detained
Due 20 October 2023
Resolved 23 October 2023
Resolution: Received ISM audit report from LR stating that 01 major non-conformity and 01 non-conformity were issued. The vessel was release from detention at 1450 (local).
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 20 October 2023
Resolved
07123-Fire fighting systems and appliances shall be kept in good working order and readily available for immediate use. PSCO observed that safety pins on all CO2 bottles were in place. Per manufacture instructions safety pins shall be removed.
74SOLAS(20) II-2/14.2.1.2
Action required: 60 - Rectify deficiencies prior to movement
Due 20 October 2023
Resolved 21 October 2023
Resolution: Recieved remote Class Survey report stating the CO2 safety pins on all CO2 bottles were removed per manufacturer instructions.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 20 October 2023
Resolved
11112-Before the ship leaves port and at all times during the voyage, all life saving appliances shall be in working order and ready for immediate use. PSCO observed forward embarkation ladder with seized shackles and wasted side ropes. Additionally,PSCO observed wasted retro tape on forward liferaft and damage to the outside shell. Furthermore, the crew was not able to provide documentation for the 2023 liferaft inspections.
74SOLAS(20) III/20.1
Action required: 17 - Rectify deficiencies prior to departure
Due 20 October 2023
Resolved 23 October 2023
Resolution: Received class (NKK) report stating that embarkation ladder, wasted shackles,FWD liferaft retro tape have been replaced and requisition for new liferafts has been noticed.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 20 October 2023
Resolved
07105- The fire resistance doors shall, as far as practicable be equivalent to that of the division in which they are fitted. PSCO observed the emergency escape door in lower deck of engine room, an A-60 boundary space, was warped and wasted to the point it did not properly close.
74SOLAS(20) II-2/47.1
Action required: 17 - Rectify deficiencies prior to departure
Due 20 October 2023
Resolved 23 October 2023
Resolution: Received class (NKK) report stating that fire door was repaired by ship staff.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 20 October 2023
Resolved
All access openings in bulkheads at ends of enclosed superstructures and hull be fitted with doors of steel or other equivalent material permanently and strongly attached to the bulkhead and framed, stiffened and fitted so that the whole structure is of equivalent strength to the unpierced bulkhead and weathertight when closed. PSCO Observed several weathertight doors on deck that were not able to be fully closed. Additionally missing doggs and excessive wastage and cracks were observed in coaming and bulkhead around door in "A-Frame SUL hydraulic room"
ICLL Reg 12.1
Action required: 17 - Rectify deficiencies prior to departure
Due 20 October 2023
Resolved 24 October 2023
Resolution: Received class (NKK) report stating that al WTD and cracks on coaming and bulkead around the doors have been repaired.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 20 October 2023
Resolved
09210-The condition of the ship and its equipment shall be maintained to ensure the ship in all means will remain fit to proceed to sea without danger to ship or person's on board. PSCO observed multiple hydraulic pipe connections, hoses and fittings leaking and accumulation on deck between the cargo holds frames and under hydraulic control stations. Additionally, excessive corrosion and cracks were found in port side cargo hold #1 hatch motor support bracket.
74SOLAS(20) I/11a
Action required: 17 - Rectify deficiencies prior to departure
Due 20 October 2023
Resolved 23 November 2023
Resolution: Hydraulic motor cargo hold No 1 port and 5 stbd overhauled and seals replaced.
Cargo hold #1 Forward and #7 aft – hydraulic cylinders overhauled with new seals.
Cargo hatch cover control stations for hatch cover #4 and #6 overhauled with new seals.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 20 October 2023
Resolved
14104-After any survey of the ship under paragraph 1 of this regulation has been completed, no changes shall be made in the structure, equipment, systems, fittings, arrangements or material covered by this survey, without the sanction of the administration, except the direct replacement of such equipment and fittings. PSCO Observed numerous modifications to the oily water separator, to include excess piping that is not reflected in the approved piping diagram for the OWS.
MARPOL Annex I/ Reg 6.4.2
Action required: 17 - Rectify deficiencies prior to departure
Due 20 October 2023
Resolved 23 November 2023
Resolution: NKK approved OWS drawing and replaced pipeline drawing
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 October 2023
Resolved
CGOO6 - Other (Safety in General) - Following installation the master, owner, operator, agent, or person in charge of the vessel subject to this subpart must properly maintain the BWMS in accordance with all manufactures specifications. PSCO observed BWMS inoperable with a leaking flange.
33CFR151.2025(a)(1)/15AC
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 20 October 2023
Resolution: BWMS leak was fixed and new BWM certificate was issued.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 10 October 2023
Resolved
03103 - Railing, gangway, walkway and means for safe passage - The condition of the ship and all equipment shall be maintained to ensure the ship in all means will remain fit to proceed to sea without danger to persons onboard. PSCO observed a broken railing on the self loader power pack system space ladder.
74SOLAS(2020)I/11A /15AC
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 20 October 2023
Resolution: New railing was installed.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 10 October 2023
Resolved
07101 - Fire prevention structural integrity - ...Stairways and lift trunks which penetrate more than a single deck shall be surrounded by at least "A-0" class divisions... PSCO observed unsealed cableway through a class boundary.
74SOLAS(2001)II/2/46.1/ 15AC
Condition: Improper Installation
Action required: 15 - Rectify deficiencies by next port
Resolved 20 October 2023
Resolution: Proper penetration of Class A boundary installed.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage of rescue boats
Issued 25 May 2023
Resolved
Launching arrangements shall comply with requirements of Reg 16. However, all rescue boats shall be capable of being launched where necessary utilizing painters, with the ship making headway at speeds up to 5 knots in calm waters. PSCO observed the rescue boats installed lifting hook was not in accordance with the ship's SOLAS Training Manual and was not a style that could be released on load.
74 SOLAS (2001) III/17.3
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Due 25 May 2023
Resolved 26 May 2023
Resolution: RECIEVED CLASS REPORT CLEARING DEF. SEE DOCS
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 25 May 2023
Resolved
Oil fuel pipes and their valves and fittings shall be of steel or other approved materials, except the restricted use of flexable pipes shall be permissable in positions where administration is satisfied they are necessary. PSCO observed multiple flexable hoses installed in the self loaded power pack hydraulic system. Some of the hoses were passing through watertight doors impeding the operation of the doors, additionally some of the hoses were damaged and actually leaking.
74SOLAS(2001) II-2/16.2.8
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 25 May 2023
Resolved 26 May 2023
Resolution: RECIEVED CLASS REPORT CLEARING DEF. SEE DOCS
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 25 May 2023
Resolved
The condition of the ship and its equipment shall be maintained to ensure the ship in all means will remain fit to proceed to sea without danger to ship or person's on board. PSCO observed multiple hydraulic pipe connections, hoses and fittings leaking and accumulations on deck between the cargo hold frames.
74 SOLAS (2020) I/11a
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 25 May 2023
Resolved 26 May 2023
Resolution: RECIEVED CLASS REPORT CLEARING DEF. SEE DOCS
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 25 May 2023
Resolved
The condition of the ship and its equipment shall be maintained to ensure the ship in all means will remain fit to proceed to sea without danger to persons on board. PSCO observed a broken railing on the self loader power pack system space ladder.
74 SOLAS (2020) I/11a
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 26 May 2023
Resolved 25 May 2023
Resolution: RECIEVED CLASS REPORT CLEARING DEF. SEE DOCS
02 - Structural Conditions › N/A - No Subsystem › Spaces in cargo areas
Issued 13 February 2020
Resolved
74 SOLAS 14 I/11(a): The condition of the ship and it's equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. A fire took place on the self-discharging conveyor belt inside the conveyor gallery. Vessel is to provide USCG class report to verify structural integrity of affected area.
Action required: 60 - Rectify deficiencies prior to movement
Due 13 February 2020
Resolved 14 February 2020
Resolution: Received class report attesting to structural integrity of vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 13 February 2020
Resolved
NOT LESS THAN ONE HALF OF THE TOTAL NUMBER OF LIFEBUOYS SHALL BE PROVIDED WITH LIFEBUOY SELF-IGNITING LIGHTS. PSCO OBSERVED 03 SELF-IGNITING LIGHTS TO BE INOPERABLE WHEN TESTED.
74 SOLAS (97) III/7.1.3
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 13 February 2020
Resolved 13 February 2020
Resolution: SELF-IGNITING LIGHTS WERE CHANGED ON SPOT. PSCO VERIFIED WORKING STATUS.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 18 October 2018
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO's observed multiple hydraulic leaks on service pipelines. RO to attest to condition of on deck hydraulic lines.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 23 October 2018
Resolution: Received NKK Class report attesting to repairs of hydraulic system. Report attached
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 18 October 2018
Resolved
Lifejackets shall be placed as to be readily accessible and their position shall be plainly indicated. PSCO's observed lifejackets blocked behind cabinets restricting accessibility and ability to be observed.
Action required: 10 - Deficiency Rectified
Resolved 18 October 2018
Resolution: PSC Officer observed cabinets removed, deficiency corrected on the spot.
Fire Fighting › Fixed Fire Detection System › Heat Detectors
Issued 19 March 2018
Resolved
0715: The function of detection system shall be periodically tested to satisfaction of admin by means of equipment producing hot air at the appropriate temp, or smoke or aerosol particles having appropriate range of density or particle size, or other phenomena assoc. w/ incipient fires to which decetor is designed to respond. Testing equip for heat sensors not onboard. 74SOLAS(97CONS)11-2/12.1.13 40(a)(c)
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 29 March 2018
Resolution: Received documenation of repair.
Deck/Cargo › Ballast › Piping
Issued 19 March 2018
Resolved
1499: The machinery, boilers, and other pressure vessels, associated piping systems, and fittings shall be of a design and construction adequate for service for which intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board. PSCE observed wooden plug in valve that is part of ballast system. 74SOLAS(04CONS)II-1/26.1. 50(a)(c).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 April 2018
Resolved 19 April 2018
Resolution: Received class report from NKK clearing deficiency. Valve was replaced- all sat.
Construction/Loadline › Hull › Bottom Plating
Issued 18 April 2016
Resolved
Whenever an accident occurs to a ship which affects the safety of the ship, the nominated surveyor or recognized organization responsible for issuing the relevant certificate shall cause investigations to determine whether a survey is recessary. As a result of vessel grounding provide class report attesting to the condition of the hull after survey. SOLAS '14 Ch. 1 Reg. 11(c)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 April 2016
Resolution: Received dive report from Marine [name withheld] stating they found a scratch 2-3' wide and 35' long on the edge of the starboard side tank #2. No dents were found and no visual damge found on the rest of the ship.