Records from 1993 to 2025. Most recent: inspection, 22 October 2025.
Inspection history · 37
22 October 2025
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8257369
15 August 2025
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8212413
22 July 2025
Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 8191866
4 March 2025
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8088389
4 March 2025
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8091450
9 December 2024
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8045387
4 October 2023
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7803561
8 September 2022
COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7552420
6 July 2020
Initial Certification · MTSA Verification · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6998424
12 March 2019
Type not recorded
No type recorded · Station Freeport · USCG Heartland District (CGD-H) · Activity 6641468
31 May 2018
Industry Initiated Exam · MTSA Verification · Administration
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6429986
15 July 2015
Industry Initiated Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5185848
1 October 2012
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4454149
29 November 2011
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4200306
18 November 2010
Type not recorded
No type recorded · Suspension & Revocation National Center of Expertise · Activity 3894160
24 February 2010
Industry Initiated Exam · MTSA Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3715770
6 October 2009
Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3609949
31 August 2009
Administrative Inspection
Administrative · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3581749
27 August 2009
Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3578513
23 June 2009
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3513657
2 May 2009
Damage Survey
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3465835
2 May 2009
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3467951
10 February 2009
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 3415397
15 August 2007
Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3036442
17 November 2006
Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2823698
5 July 2006
MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2702748
6 June 2006
Damage Survey · Deficiency Check · Uninspected Other
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2672945
6 June 2006
Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2673869
14 March 2006
Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2602156
3 February 2006
Security Plan Amendment Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2578662
16 June 2005
Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 2448921
5 February 2005
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 2306532
30 January 2004
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2003936
22 October 2002
Annual Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1694685
2 October 2001
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1703
2 October 2001
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 213893
10 March 1993
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 77848
09 - Working and Living Conditions › 091 - Living Conditions › Water, pipes, tanks
Issued 22 October 2025
Resolved
When operating a vessel on a body of water where the discharge of treated or untreated sewage is prohibited by the Environmental Protection Agency under 40 CFR 140.3 or 140.4, the operator must secure each Type I or Type II device in a manner which prevents discharge of treated or untreated sewage. Hole found in MSD PVC Piping in front compartment of vessel.
33 CFR 159.7(A)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 October 2025
Resolution: Verified PVC Pipe was replaced. ALL SAT.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 22 October 2025
Resolved
Survival craft must be stowed in accordance with the requirements of § 199.130 of this chapter, as far as is practicable on existing towing vessels. Rigid Buoyant Apparatus platform cant secure RBA from slide around on the deck.
46 CFR 141.310
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 October 2025
Resolution: Verified Pegs installed to vessel to contain RBA from sliding. ALL SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 22 October 2025
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. MI observed fuel leak on emergency
shutoff.
46 CFR 143.205(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 October 2025
Resolution: Verified securing of fuel leak. ALL SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 22 October 2025
Resolved
All bilges and void spaces are kept free from accumulation of combustible and flammable materials and liquids insofar as practicable. MI observed accumulation
of fuel and oily water in bilge system.
46 CFR 142.220(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 October 2025
Resolution: Verified bilge system cleaned out. ALL SAT.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 22 October 2025
Resolved
Emergency lighting must be provided for all internal crew working and living areas. Emergency lighting sources must provide for sufficient illumination under emergency conditions to facilitate egress from each space. Engine space e-lighting didn't have sufficient enough illumination of light.
46 CFR 143.410(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 October 2025
Resolution: Verified sufficient illumination in engine space e-lighting. ALL SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 March 2025
Resolved
Propulsion machinery, including main engines, reduction gears, shafting, bearinqs, and electrlcal equipment and systems, must
(1) Be maintained to ensure proper operation.
Vesse1 had a loss of port engine. Vessel authorized
single voyage IAW their transit plan to FAS
Environmental dock for repairs. Vessel to remain at
location (FAS dock) and notify CG MSU Morqan City upon
completion of repairs for CG inspector verification and
successful tests of engine and propulsion.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 6 March 2025
Resolution: Port MDE replaced and tested sat.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 9 December 2024
Resolved
"A towing vessel must carry a combination of day and night visual distress signals indicated in Table 141.370 of § 141.370 for specified areas where the vessel operates."
Vessel did not have adequate visual distress signals to meet the 6 day and 6 night requirement for lakes, bays, and sounds route (>3nm from shore)
Action required: 10 - Deficiency Rectified
Resolved 9 December 2024
Resolution: Vessel ensured proper number of handheld red flares onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 9 December 2024
Resolved
"Each buoyant apparatus must have Type II retroreflective material meeting subpart 164.018 of this chapter on each side and end. The material must be in strips at least 50 mm (2 in.) wide extending from top to bottom over the side or end and continuing over the top and bottom surfaces of the apparatus."
Rigid buoyant apparatus did not have adequate retroreflective material.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 December 2024
Resolved 9 December 2024
Resolution: Added new SOLAS tape to buoyant apparatus
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 December 2024
Resolved
"Each lifebuoy on a towing vessel must be marked in block capital letters with the name of the vessel"
Vessel name stenciling had faded significantly.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 December 2024
Resolved 9 December 2024
09 - Working and Living Conditions › 091 - Living Conditions › Access/structure
Issued 9 December 2024
Resolved
A vessel must be operated in accordance with applicable
laws and regulations and in such a manner as to afford protection against hazards to life, property, and the
environment."
Insulation in crew accommodation space was falling out of the ceiling.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 December 2024
Resolved 9 December 2024
Resolution: Removed excess insulationin ceiling to prevent the tiling from continuing to fall out.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 9 December 2024
Resolved
"Emergency lighting must be provided for all internal crew working and living areas. Emergency lighting sources must provide for sufficient illumination under emergency conditions to facilitate egress from each space and must be either:(1) Automatic, battery-operated with a duration of no less than 2 hours; or(2) Non-electric, phosphorescent adhesive lighting strips that are installed along escape routes and sufficiently visible to enable egress with no power."
Vessel passageway near crew accommodations spaces found with inadequate egress lighting.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 December 2024
Resolved 9 December 2024
Resolution: Added 04 phosphorescent lighting strips to increase visibility for egress
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 9 December 2024
Resolved
"A towing vessel must carry adequate and up-to-date charts, maps, and nautical publications for the intended voyage, including:
(1) Charts, including electronic charts acceptable to the Coast Guard, of appropriate scale to make safe navigation possible."
Vessel was outfitted with recreational Rosepoint electronic charting software. Pilothouse did not have adequate space to navigation with paper charts in addition to the charts onboard not being of appropriate scale to use for navigation in AOR.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 December 2024
Resolution: Vessel company installed commercial Rosepoint electronic charting software. The system will operate on back-up power. Insufficient charts removed from inventory.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 4 October 2023
Resolved
For vessels other than those covered in paragraphs (b) and (c) of this section, the name of the vessel must be marked on some clearly visible exterior part of the port and starboard bow and the stern of the vessel. The hailing port of the vessel must be marked on some clearly visible exterior part of the stern of the vessel. The Vessel's new name and hailing port was missing from the stern of the vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 November 2023
Resolved 20 October 2023
Resolution: The Vessel's new name and hailing port mounted on the stern.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 4 October 2023
Resolved
Each lifejacket must be marked: (1) In block capital letters with the name of the vessel;
No block lettering on Lifejackets.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 October 2023
Resolved 20 October 2023
Resolution: New block lettering on Lifejackets.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 4 October 2023
Resolved
Each lifebuoy on a towing vessel must:Be marked in block capital letters with the name of the vessel;
No block lettering on the Lifebuoys.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 October 2023
Resolved 20 October 2023
Resolution: New block lettering on Lifebuoys.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 4 October 2023
Resolved
n existing vessel may be deemed by the OCMI, or TPO, to be in compliance with this subpart provided that either:
(b) The vessel has been both in satisfactory service insofar as structural adequacy is concerned and does not cause the structure of the vessel to be questioned by either the OCMI,
-Pin holes and wastage found on the outside of the port side bulkhead of the supper structure appx. 3-4 in off the main deck near the galley's weather tight door.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 November 2023
Resolved 20 October 2023
Resolution: Welded repair of Pin holes and wastage found on the outside of the port side bulkhead of the supper structure.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 4 October 2023
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Missing and damage guards on both generators.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 October 2023
Resolved 20 October 2023
Resolution: Replaced and installed new guards.
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 31 August 2009
Resolved
Damaged due colliding with Dredge pipe as it floated up from the dredge "White Rock".
Action required: 705 - Other - as specified
Resolved 24 February 2010
Resolution: since then vessel has had dry dock top repair damages.
Engineering › Diesel Engine (propulsion-electric) › Valve
Issued 6 June 2006
Resolved
Pressure valve failure caused an engine room fire.
Action required: 705 - Other - as specified
Due 20 June 2006
Resolved 7 June 2006
Resolution: Replaced valve on starboard reduction gear. Repairs are satisfactory. Vessel also replaced similar valve on the port reduction gear.
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 6 June 2006
Resolved
Lifejackets are missing lights.
Action required: 705 - Other - as specified
Due 20 June 2006
Resolved 7 June 2006
Resolution: Lifejackets have all been replaced. New water activated lights are attached. Instructed crew on how to conduct a self test of the light.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 6 June 2006
Resolved
Crew bunk does not have lifejackets.
Action required: 705 - Other - as specified
Due 20 June 2006
Resolved 20 June 2006
Resolution: New lifejackets were placed at every bunk, pilot house, galley, and laundry area, 9 in total.
Lifesaving › Visual Distress Signals (General) › Storage
Issued 6 June 2006
Resolved
Life ring light was mounted in a non-float free manner.
Action required: 705 - Other - as specified
Due 20 June 2006
Resolved 7 June 2006
Resolution: Life ring was remounted and now installed in a float free manner.