MAURY USCG vessel records
← All vessels

ANGELIA B

Built
1981
Last inspected
28 October 2025
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 28 October 2025
…with no type recorded38
Operational controls None recorded without a removal date
Years with a record 24 calendar years (1992–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDI3699
193789
Flag
UNITED STATES
Maury page id
psix-193789

Documentation record

Registered dimensions (L × B × D)49.2 ft × 22.0 ft × 7.3 ft
Registered tonnagegross 80 / net 54
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMARINE BUILDERS INC · CLARKSVILLE, IN, UNITED STATES · built 1981
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portHENDERSON, KY
Endorsements, as the file codes themcw_un
DocumentationValid · issued 24 April 2026 · expires 31 May 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it54 - Regulatory (Subpart C or D), Net Ton
80 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 50 inspections, each with its date, unit and type; 33 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 10 other vessels inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 10

Inspection history · 50

28 October 2025 Deficiency Check · Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 8254441
2 October 2024 Deficiency Check · Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7990437
26 September 2023 Annual Inspection · Deficiency Check
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7790885
21 November 2022 Deficiency Check
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7597654
20 September 2022 Annual Inspection · Deficiency Check
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7536129
2 November 2021 Deficiency Check · Initial Certification · Administrative Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7335464
28 July 2021 Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 7270630
1 March 2021 Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7149788
7 April 2018 Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6387786
9 September 2017 Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6272569
20 July 2017 Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6215959
26 January 2017 Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6077660
3 June 2016 Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 5901383
26 April 2016 Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 5864811
2 March 2015 Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 5076876
14 January 2014 Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4782718
24 August 2011 Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4127410
11 February 2011 Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3947067
12 July 2010 Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3793318
10 November 2009 Administration · DAPI Audit · MTSA Verification · Industry Initiated Exam
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3632150
10 April 2009 Deficiency Check
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3449974
25 February 2009 Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3424529
1 November 2007 Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3101480
25 October 2005 MTSA Verification
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 2523114
24 May 2004 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 2076571
16 April 2004 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 2045397
30 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1971795
15 August 2002 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1902663
7 February 2002 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1487696
25 October 2000 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 183239
9 July 2000 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 50516
13 April 2000 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 104470
10 November 1999 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 12281
6 October 1999 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 119580
4 September 1998 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 97246
19 July 1998 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 39274
21 April 1998 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 136535
21 April 1998 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 142372
17 April 1998 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 134606
18 October 1995 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 26771
2 October 1995 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 119268
19 September 1995 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 104204
1 September 1995 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 100918
2 August 1995 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 131846
12 May 1995 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 89182
12 May 1995 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 221216
1 March 1995 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 187266
25 January 1995 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 223677
2 November 1994 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 168447
4 March 1992 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 132060

Deficiency record · 33

09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 October 2025 Resolved
Individual circuit breakers on switchboards and distribution panels must be labeled with a description of the loads they serve. Panel not completely labled.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 December 2025
Resolution: Panel has been completely labled.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 28 October 2025 Resolved
Each lifebuoy on a towing vessel must be approved under approval series 160.050 or 160.150. Grab lines around body of lifebuoy wear frayed and need to be replaced.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 December 2025
Resolution: Grab lines around body of lifebuoy has been replaced.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 28 October 2025 Resolved
Each towing vessel must be equipped with navigation lights in accordance with 33 CFR part 84 as appropriate to its area of operation. Uppermost nav light on mast not operable.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 December 2025
Resolution: Uppermost nav light on mast is operable.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 2 October 2024 Resolved
46 CFR 143.230 (c)(3) - The following systems must be equipped with gauges at the machinery location: Auxiliary generator engine lubricating oil pressure and auxiliary generator engine RPM. Gauage was missing.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 November 2024
Resolved 30 October 2024
Resolution: Replaced Gauage.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 26 September 2023 Resolved
Lifebuoy on port side pilothouse did not have vessel name on it.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 November 2023
Resolved 6 November 2023
Resolution: Vessels name is on lifebuoy
08 - Alarms › N/A - No Subsystem › Engineers' alarm
Issued 26 September 2023 Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention. Alarms must be visible and audible at each operating station.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 November 2023
Resolved 6 November 2023
Resolution: Alarms is visible and audible at each operating station.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 26 September 2023 Resolved
Each exhaust pipe from an internal combustion engine which is within reach of personnel must be insulated or otherwise guarded to prevent burns. The lagging on the port engine turbo has deteriorated and needs replaced.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 November 2023
Resolved 6 November 2023
Resolution: Lagging was replaced
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 26 September 2023 Resolved
Each vessel must be designed and constructed to minimize fire hazards insofar as reasonable and practicable. Found turbo on port engine to be leaking
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 November 2023
Resolved 6 November 2023
Resolution: turbo on port engine is no longer leaking
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 September 2023 Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Found melted wire in battery box in ER
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 November 2023
Resolved 6 November 2023
Resolution: wire in battery box in ER was replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 September 2022 Resolved
Maintenance records for readiness and testing of machinery alarms and pressure relief valves are missing. Owner must insure all applicable items listed in the 143.245(b) table are completed and logged. 46 cfr 143.245
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2022
Resolved 21 November 2022
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 20 September 2022 Resolved
Each towing vessel must be maintained and operated so as to minimize fire hazards and to ensure the following: Fuel containment full of debris. 46 cfr 142.220
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2022
Resolved 27 October 2022
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 September 2022 Resolved
Electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Forward port side engine room light cover loose. 46 cfr 143.205
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2022
Resolved 27 October 2022
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 September 2022 Resolved
46 cfr 143.205 - Electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Starboard electric winch box in lower port side engine room exposed cover.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2022
Resolved 27 October 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 20 September 2022 Resolved
46 cfr 143.205 - Electrical and machinery systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Volt and amp meter not functioning for generators
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2022
Resolved 27 October 2022
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 September 2022 Resolved
Potable water feed pump was in operable and open exposing potential live wires. Repair/replace pump.46CFR143.205
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2022
Resolved 27 October 2022
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 September 2022 Resolved
46 cfr 143.205 - Electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Broke electrical outlet midships port side engine room.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2022
Resolved 27 October 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 September 2022 Resolved
46 cfr 143.260 - The remote fuel shutoff must be operable from a safe place outside the space where the valve is installed. The Remote Fuel shutoff cable snapped while testing operation. Insure cable is protected from being severed by deck plates or any other objects.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 September 2022
Resolved 27 October 2022
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 September 2022 Resolved
46 cfr 143.205 - Electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Forward midships engine room battery charging cables need to be permanently installed
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2022
Resolved 27 October 2022
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 September 2022 Resolved
46 cfr 143.205 - Electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Positive post on above battery frayed wire.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2022
Resolved 27 October 2022
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 September 2022 Resolved
46 cfr 143.205 - Electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Stern deck light broken and exposed wires.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2022
Resolved 27 October 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 September 2022 Resolved
46 cfr 142.220 - Each towing vessel must be maintained and operated so as to minimize fire hazards and to ensure the following: (a) All bilges and void spaces are kept free from accumulation of combustible and flammable materials and liquids insofar as practicable. Collection well for shaft water needs cleaned out before operations.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 19 October 2022
Resolved 20 September 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 September 2022 Resolved
46 cfr 141.340 - Each lifejacket must be marked In block capital letters with the name of the vessel and must have the following attachments and fittings: 1) Each lifejacket must have a lifejacket light (2) Each lifejacket must have a whistle firmly secured by a cord to the lifejacket. 2 pfds found with no name, light or whistle.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2022
Resolved 27 October 2022
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 20 September 2022 Resolved
46 cfr 140.405(c) - The emergency duties and duty stations required by this section must be posted at each operating station and in a conspicuous location in a space commonly visited by crewmembers. Emergency duty station not posted in pilot house and galley
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2022
Resolved 27 October 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 September 2022 Resolved
46 cfr 141.360 - At least two lifebuoys on a towing vessel greater than 26 feet must be fitted with a floating electric water light approved under approval series 161.010 or 161.110. Starboard lifebuoy float light inoperable
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2022
Resolved 27 October 2022
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 2 November 2021 Resolved
Vessel operator does not have an FFC radio operator permit.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 January 2022
Resolved 5 January 2022
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 2 November 2021 Resolved
Fire Control panel has alarms that are being displayed identifying areas within the system that are giving false positive alarms. Even when the fire panel has been re-set
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 January 2022
Resolved 10 February 2022
Resolution: Fire control panel has been serviced and working as designed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 November 2021 Resolved
Electrical wires were exposed in the pilot house, needs to have a conver installed to protect from the elements.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 January 2022
Resolved 5 January 2022
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 2 November 2021 Resolved
Flammable Locker needs to have a portable fire extinguisher readily available.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 January 2022
Resolved 5 January 2022
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 2 November 2021 Resolved
Vessel was fitted with old remote fuel shut off lever on port and STBD main deck that is no longer needed or used. Remove old handle to the satisfaction of attending Marine Inspector.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 January 2022
Resolved 5 January 2022
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 2 November 2021 Resolved
Vessels stern port hand rail is missing about 10' on the rear of the engine room outboard bulkhead.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 January 2022
Resolved 10 February 2022
Resolution: Vessels stern port hand rail has been installed on the rear of the engine room outboard bulkhead.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 2 November 2021 Resolved
Machinery alarms were all summary alarms. Owner shall ensure that the master is able to identify each induvial alarm at either the operating station or in the engine room.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 January 2022
Resolved 5 January 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 2 November 2021 Resolved
Port Generators battery charger was not operating. Replace with approved marine style battery charger.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 January 2022
Resolved 10 February 2022
Resolution: Port Generators battery charger has been replace with approved marine style battery charger.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 28 July 2021 Resolved
All owners and operators of an existing towing vessel must have a valid COI prior to the specified phase-in period. This vessel is one of the associated fleet that has not obtained a valid COI. The vessel shall be made available for a Coast Guard COI inspection within 90 days. If an inspection is not completed prior to this date, the action for this deficiency shall be changed to a 60 (Rectify deficiencies prior to movement) and the vessel may no long be permitted to operate.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Due 26 October 2021
Resolved 7 December 2021
Resolution: Vessel passed ICOI Inspection.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.