Records from 2002 to 2025. Most recent: inspection, 1 May 2025.
Documentation record
Registered dimensions (L × B × D)70.0 ft × 28.0 ft × 10.0 ft
Registered tonnagegross 131 / net 105
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderRODRIGUEZ BOAT BUILDERS INC · CODEN, AL, UNITED STATES · built 1999
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portEVANSVILLE, IN
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 20 November 2025 · expires 30 November 2026
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it131 - Simplified, Gross Ton
105 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 32
1 May 2025
Administrative Inspection
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 8126660
23 January 2025
COI Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 8064529
2 May 2024
Administrative Inspection
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7905129
21 February 2023
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7639372
17 February 2022
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7398362
4 January 2022
TPO Audit
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7373778
15 April 2021
Damage Survey
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7175629
14 April 2021
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7175591
7 February 2021
Deficiency Check · Damage Survey
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7137407
31 October 2019
Deficiency Check
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6850518
29 October 2019
Initial Certification · Administrative Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6807740
29 October 2019
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6848994
15 August 2018
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6517631
6 December 2017
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6322924
19 August 2017
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6253772
19 May 2016
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 5899428
26 January 2015
Administration · Industry Initiated Exam · MTSA Verification
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 5059749
3 August 2013
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4677507
31 January 2013
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4527687
23 January 2013
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4521548
27 June 2012
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4375170
28 April 2011
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4002977
5 January 2010
Deficiency Check
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3659448
18 November 2009
MTSA Verification · Industry Initiated Exam
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3635913
1 November 2007
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3101480
1 April 2007
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 2902942
25 October 2005
MTSA Verification
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 2523094
24 May 2004
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 2076581
30 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1971797
25 April 2002
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1609242
8 April 2002
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1609204
25 January 2002
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1482659
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 April 2021
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Vessels starboard engine shutdown during operation. Repair/replace as needed to bring port engine back to full operational capabilities.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 15 May 2021
Resolved 21 April 2021
Resolution: Cleared by TPO
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 February 2021
Resolved
On 06 February 2021 at approx. 23:15 local time the crew of the ITV KELLE B was conducting checks prior to getting underway at Green River mile 42 when it was discovered that the starboard generator would not start. Vessel authorized to move deadship to EMS facility at Ohio River mile 786 to conduct repairs. Repairs and any temporary arrangements for a temporary generator shall be conducted to the satisfaction of the vessel's TPO and reported to Coast Guard Sector Ohio Valley before placing the vessel back into service.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 10 February 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 October 2019
Resolved
Each towing vessel must perform tests of Pressure Vessel relief valves IAW 46 CFR 143.245(b) Vessel Master was unable to provide documentation of testing relief valves.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 November 2019
Resolved 31 October 2019
Resolution: The owner's representative provided proof of relief valve testing dated 17FEB2017.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 October 2019
Resolved
Electrical components that pose an electrical hazard must be in an enclosure; Electrical Sub-Panel #2 is missing blank where breaker is missing.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 November 2019
Resolved 31 October 2019
Resolution: TPO provided objective evidence that the deficiency is cleared.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 October 2019
Resolved
All seals and gaskets must be properly maintained to prevent leaks of flammable liquid; STBD MDE Racor selector valve is dripping approx. 1 drop every 30 sec from the stem. STD Gen fuel supply piping has fuel leaching at hose to pipe coupling. Port MDE fuel return line on fwd upper portion of engine show signs of leaching.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 November 2019
Resolved 31 October 2019
Resolution: TPO provided objective evidence that the deficiency is cleared.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 29 October 2019
Resolved
At least two lifebuoys on a towing vessel greater than 26 feet must be fitted with a floating electric water light and attached by the lanyard with a corrosion-resistant clip to allow the water light to be quickly disconnected from the lifebuoy. The clip and line must have at least a breaking strength of 50 lbs.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 November 2019
Resolved 31 October 2019
Resolution: TPO's stance is the regulations do not prescribe the method of connecting the waterlight if the vessel has 2 or more liferings.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Other (ISM)
Issued 29 October 2019
Resolved
When conducting a survey of a towing vessel, the surveyor must determine that the item or system functions as designed, is free of defects or modifications that reduce its effectiveness, is suitable for the service intended, and functions safely in a manner consistent for vessel type, service and route. A visual examination and tests of the vessel and its equipment and systems in order to confirm that their condition is properly maintained and that proper quantities are onboard. Vessel’s last [name withheld] stated that vessel wasn’t equipped with Pressure Vessels > 5 Cubic Feet; MI noted that vessel was equipped w/ 2 Pressure Vessels > 5 Cubic Feet. Survey also indicated the presence of distress signals, but they were not onboard during inspection. Additionally, the checklist indicated the presence of ring life buoys and the waterlight arrangement was "not applicable". Corrective action plan needs to be created to address the discrepancy.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2019
Resolved 31 October 2019
Resolution: Objective evidence was provided that all deficiencies were cleared.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 29 October 2019
Resolved
A towing vessel must carry a combination of day and night visual distress signals; Vessel was not equipped with flares or stowage container required by 141.375(e). Vessel rep. placed the required flares and container onboard before inspection was complete.
Action required: 10 - Deficiency Rectified
Due 29 October 2019
Resolved 29 October 2019
Resolution: Visual distress signals were brought on board during the inspection.